A new issue of the above journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
This blog has been set up for editors, reviewers, authors and readers of Elsevier's Analytical Chemistry Journals - all of which can be seen below. It will be updated from Monday to Friday with general news and announcements concerning the titles listed on this page. It should be noted that the views or claims made in the news items and feeds are not necessarily those of the Publisher.
Tuesday, 14 December 2010
Just Published: Journal of Analytical and Applied Pyrolysis
New Downflow Workstations
The New DWS range of Downflow Workstations from Air Science give the operator safety where routine work is being carried out.
These units operate at low noise levels and because they recirculate, they do not exhaust expensive conditioned and/or heated air into the atmosphere.
The DWS Workstations have been specifically designed to provide a small bench mounted unit with unrestricted access for those operations that are difficult to perform in a conventional fume hood.To provide protection, the downflow action takes the contaminated air away from the operator and an alarm will sound when the airflow falls to an unacceptable level.
The main filter can be chosen from 14 different types of carbon, which include specialty media for vapors of organics, solvents, acids, mercury and formaldehyde. HEPA filters for particulate filtration are also available to suit the application.
For additional information on Downflow Workstations, call, visit the website, or email Air Science.Air Science USAPO Box 62296
Fort Myers, Florida 33906 USA
Fort Myers, Florida 33906 USA
Toll Free: 800-306-0656
Phone: 239-489-0024
Fax: 800-306-0677
E-mail: info@airscience.comPhone: 239-489-0024
Fax: 800-306-0677
Web: http://www.airscience.com/
Monday, 13 December 2010
Efficient & Reliable Automated Filling of 2-Compartment Petri Dishes
Using a MEDIAJET vario Automatic Media Preparation System from INTEGRA - leading Danish healthcare provider - Herlev Hospital has drastically increased the efficiency and reliability of preparing its 2-compartment agar plates.
For many applications, the amount of required agar can be reduced by using two-compartment Petri dishes. However, pouring biplates by hand is time-consuming and inefficient. The MEDIAJET fitted with biplate filling option is proven to offer an efficient and reliable solution for preparing 2-compartment Petri dishes automatically.
Located in Herlev, close to Copenhagen - Herlev Hospital (www.herlevhospital.dk/) is engaged in providing a range of health care and hospital services to diverse patients. It is principally focused on providing emergency treatment services for acute diseases. The hospital caters to more than 700,000 people across the Ballerup, Gladsaxe, Herlev, Egedal, Lyngby, Rudersdal and capital region areas of Denmark.
Anette Banke, Senior Pharmaconomist at Herlev Hospital commented "We have had our MEDIAJET vario with biplate option up and running for two years filling over 70,000 biplates annually. We also use the MEDIAJET to fill standard 90mm Petri dishes. Our system is running from morning until evening almost every day. We have never experienced any problems with the MEDIAJET and it is by far the most reliable instrument we have ever had for Petri dish filling. You could almost say: it takes care of itself! This of course gives us the chance to fulfil other tasks in the laboratory while it's running increasing our laboratory productivity". We only have one wish: We would like to have an additional MEDIAJET system such that we can expand our service to supply other hospitals with top quality agar plates".
The MEDIAJET vario with biplate option offers the unique flexibility of high throughput filling of Petri dishes of various sizes, Petri dishes with 2 compartments and test tubes of various diameters and length.
Using a proven mechanical dish guidance system, monitored by a set of sensors throughout the filling process, the compact MEDIAJET vario provides truly reliable, walk-away operation. Operational downtime and media loss due to 'dish jams' resulting from variations in the diameter, shape and rim profile of the disposable plastic Petri dishes are completely eliminated.
For further information please contact INTEGRA Biosciences AG on telephone +41-81-286-9530 / email info@integra-biosciences.com. In the USA please contact Viaflo Corporation on telephone +1-603-578-5800 or by email loneil@viaflo.com.
For many applications, the amount of required agar can be reduced by using two-compartment Petri dishes. However, pouring biplates by hand is time-consuming and inefficient. The MEDIAJET fitted with biplate filling option is proven to offer an efficient and reliable solution for preparing 2-compartment Petri dishes automatically.
Located in Herlev, close to Copenhagen - Herlev Hospital (www.herlevhospital.dk/) is engaged in providing a range of health care and hospital services to diverse patients. It is principally focused on providing emergency treatment services for acute diseases. The hospital caters to more than 700,000 people across the Ballerup, Gladsaxe, Herlev, Egedal, Lyngby, Rudersdal and capital region areas of Denmark.
Anette Banke, Senior Pharmaconomist at Herlev Hospital commented "We have had our MEDIAJET vario with biplate option up and running for two years filling over 70,000 biplates annually. We also use the MEDIAJET to fill standard 90mm Petri dishes. Our system is running from morning until evening almost every day. We have never experienced any problems with the MEDIAJET and it is by far the most reliable instrument we have ever had for Petri dish filling. You could almost say: it takes care of itself! This of course gives us the chance to fulfil other tasks in the laboratory while it's running increasing our laboratory productivity". We only have one wish: We would like to have an additional MEDIAJET system such that we can expand our service to supply other hospitals with top quality agar plates".
The MEDIAJET vario with biplate option offers the unique flexibility of high throughput filling of Petri dishes of various sizes, Petri dishes with 2 compartments and test tubes of various diameters and length.
Using a proven mechanical dish guidance system, monitored by a set of sensors throughout the filling process, the compact MEDIAJET vario provides truly reliable, walk-away operation. Operational downtime and media loss due to 'dish jams' resulting from variations in the diameter, shape and rim profile of the disposable plastic Petri dishes are completely eliminated.
For further information please contact INTEGRA Biosciences AG on telephone +41-81-286-9530 / email info@integra-biosciences.com. In the USA please contact Viaflo Corporation on telephone +1-603-578-5800 or by email loneil@viaflo.com.
Friday, 10 December 2010
Natural Product Sample Preparation Web Page
Genevac has announced a new web page (www.genevac.com/naturalproducts) that brings together the latest technological innovations, applications advances and references for evaporation and sample concentration techniques relating to natural products research.
Genevac evaporator systems are also widely used by researchers seeking to extract functional molecules from natural sources. Typically investigations involve a primary solvent extraction of natural products that result in a large volume of crude extract. The crude extract is then often concentrated before being fractionated to isolate each component. The time consuming concentration task has been revolutionised by the unique large volume parallel processing capabilities of the ROCKET evaporator. The process of natural product fractionation typically produces many samples from a single extract. These samples need then to be evaporated before storage or analysis. Examples of high throughput evaporation and lyophilisation techniques using Genevac HT Series evaporators for this purpose are detailed.
Web links are provided to a bibliography of scientific publications in peer review journals that offer further insight into how modern evaporative sample preparation methods are enabling laboratories accelerate and improve the process of obtaining new compounds from a range of natural product sources.
Genevac, part of the SP Scientific group, was founded in 1990. Today the company employs around 85 people, with manufacturing, R&D and marketing headquartered in Ipswich, UK. Genevac today offers a comprehensive portfolio of evaporators to suit almost any solvent removal application, purchasing budget or productivity requirement.
Genevac evaporator systems are also widely used by researchers seeking to extract functional molecules from natural sources. Typically investigations involve a primary solvent extraction of natural products that result in a large volume of crude extract. The crude extract is then often concentrated before being fractionated to isolate each component. The time consuming concentration task has been revolutionised by the unique large volume parallel processing capabilities of the ROCKET evaporator. The process of natural product fractionation typically produces many samples from a single extract. These samples need then to be evaporated before storage or analysis. Examples of high throughput evaporation and lyophilisation techniques using Genevac HT Series evaporators for this purpose are detailed.
Web links are provided to a bibliography of scientific publications in peer review journals that offer further insight into how modern evaporative sample preparation methods are enabling laboratories accelerate and improve the process of obtaining new compounds from a range of natural product sources.
Genevac, part of the SP Scientific group, was founded in 1990. Today the company employs around 85 people, with manufacturing, R&D and marketing headquartered in Ipswich, UK. Genevac today offers a comprehensive portfolio of evaporators to suit almost any solvent removal application, purchasing budget or productivity requirement.
Thursday, 9 December 2010
Automated Sample Preparation of Peptides Designated for MALDI
A new application note from Agilent Automation Solutions describes a protocol for automated sample preparation and MALDI spotting developed with the protein analytics group of Dr. Lottspeich at the Max Planck Institute of Biochemistry in Martinsried, Germany.
The new protocol automates the sample preparation steps (cleansing and desalting) of peptides designated for mass spectrometry and the subsequent spotting onto a MALDI target plate using the Agilent Bravo Automated Liquid Handling Platform and C18 filled VeloTips from Glygen.
In order to get high quality peptide mass fingerprints in MALDI mass spectrometry, peptides must be concentrated and cleansed from impurities of previous steps. In particular, salts and buffer components originating from the protein digests should be removed. There are several manual cleansing tools available. All are based on various chromatography media and require multiple aspiration/dispensing or mixing steps. While manual sample handling remains a tedious procedure and extremely difficult to standardize, automation of the routine has never been truly feasible on any automation platform due to several technical limitations.
In the application note the authors compare automated sample preparation for MALDI-MS analysis on the Agilent Bravo Automated Liquid Handling Platform with a traditional manual cleansing process using Millipore ZipTips. A protocol for the binding, washing, elution, and direct spotting onto MALDI targets was created using Agilent VWorks Automation Control software is described which can be adapted to various MALDI target plates, labware, and pipetting tasks. Results show that peptide mass fingerprints produced by the automatic workflow performed equally well or better than the manual process regarding signal intensity and protein sequence coverage. As an additional benefit, the whole process is carried out in a reproducible and timesaving manner. The outcome of the experimentation shows that the automatic workup results in a better sequence coverage and Mascot score than both the tested manual workups.
The authors conclude that the Bravo Automated Liquid Handling Platform has been proven to be an effective tool for fully automated sample preparation with C18 VeloTips and subsequent MALDI target spotting processes.
For a copy of the application note please visit http://www.chem.agilent.com/Library/applications/5990-6241en_lo%20CMS.pdf or contact your local Agilent Automation sales office.
The new protocol automates the sample preparation steps (cleansing and desalting) of peptides designated for mass spectrometry and the subsequent spotting onto a MALDI target plate using the Agilent Bravo Automated Liquid Handling Platform and C18 filled VeloTips from Glygen.
In order to get high quality peptide mass fingerprints in MALDI mass spectrometry, peptides must be concentrated and cleansed from impurities of previous steps. In particular, salts and buffer components originating from the protein digests should be removed. There are several manual cleansing tools available. All are based on various chromatography media and require multiple aspiration/dispensing or mixing steps. While manual sample handling remains a tedious procedure and extremely difficult to standardize, automation of the routine has never been truly feasible on any automation platform due to several technical limitations.
In the application note the authors compare automated sample preparation for MALDI-MS analysis on the Agilent Bravo Automated Liquid Handling Platform with a traditional manual cleansing process using Millipore ZipTips. A protocol for the binding, washing, elution, and direct spotting onto MALDI targets was created using Agilent VWorks Automation Control software is described which can be adapted to various MALDI target plates, labware, and pipetting tasks. Results show that peptide mass fingerprints produced by the automatic workflow performed equally well or better than the manual process regarding signal intensity and protein sequence coverage. As an additional benefit, the whole process is carried out in a reproducible and timesaving manner. The outcome of the experimentation shows that the automatic workup results in a better sequence coverage and Mascot score than both the tested manual workups.
The authors conclude that the Bravo Automated Liquid Handling Platform has been proven to be an effective tool for fully automated sample preparation with C18 VeloTips and subsequent MALDI target spotting processes.
For a copy of the application note please visit http://www.chem.agilent.com/Library/applications/5990-6241en_lo%20CMS.pdf or contact your local Agilent Automation sales office.
Wednesday, 8 December 2010
Rapid Analysis of Polycyclic Aromatic Hydrocarbons (PAH)
A rapid gradient HPLC method for simultaneous determination of 16 PAH according to US EPA 610 method is presented. A baseline resolution for all 16 target analytes in less than 2.50 minutes could be achieved by using a KNAUER BlueOrchid PAH 50 x 2 mm column...
Highly Flexible Device for Presenting and Storing SBS-format Labware
The Agilent Labware MiniHub from Agilent Automation Solutions is a rotating random-access device for presenting and storing SBS-format labware in laboratory automation systems.
An efficient modular unit, the Labware MiniHub features user-configurable shelf spacing that easily accommodates a mix of microplates, tube racks, deep-well microplates, and pipette tip boxes while maintaining a compact footprint. The Agilent Labware MiniHub is designed with your applications in mind. Small but flexible, and safer than other alternatives, the Labware MiniHub solves all your room-temperature storage needs.
A novel concept in labware storage, stackable spacers in the Agilent Labware MiniHub allow the height between shelves to be adjustable, thus permitting different labware types in the same carousel and easily creating multiple locations for storage of any given labware. Unique shelf design permits both portrait and landscape access for most robots. In addition, the size of cutouts in the shelves fits popular filter plates, preventing contamination issues.
The Labware MiniHub uses the same direct-drive technology as employed by the Agilent Direct Drive Robot (DDR) thereby delivering top reliability with the highest levels of safety. With infinite bi-directional rotation, the Labware MiniHub never needs to unwind and always takes the shortest route to its target position. With a brushless motor and the bearing as the only moving parts, the mechanical design is simple, efficient and maintenance-free, thus ensuring high levels of dependability and a reduced cost of ownership. Positional accuracy is guaranteed by combining a high resolution optical encoder with the stepper motor.
For a technical datasheet describing the Agilent Labware MiniHub please visit http://www.chem.agilent.com/Library/datasheets/Public/5990-6670en_lo%20CMS.pdf or contact your local Agilent Automation sales office.
An efficient modular unit, the Labware MiniHub features user-configurable shelf spacing that easily accommodates a mix of microplates, tube racks, deep-well microplates, and pipette tip boxes while maintaining a compact footprint. The Agilent Labware MiniHub is designed with your applications in mind. Small but flexible, and safer than other alternatives, the Labware MiniHub solves all your room-temperature storage needs.
A novel concept in labware storage, stackable spacers in the Agilent Labware MiniHub allow the height between shelves to be adjustable, thus permitting different labware types in the same carousel and easily creating multiple locations for storage of any given labware. Unique shelf design permits both portrait and landscape access for most robots. In addition, the size of cutouts in the shelves fits popular filter plates, preventing contamination issues.
The Labware MiniHub uses the same direct-drive technology as employed by the Agilent Direct Drive Robot (DDR) thereby delivering top reliability with the highest levels of safety. With infinite bi-directional rotation, the Labware MiniHub never needs to unwind and always takes the shortest route to its target position. With a brushless motor and the bearing as the only moving parts, the mechanical design is simple, efficient and maintenance-free, thus ensuring high levels of dependability and a reduced cost of ownership. Positional accuracy is guaranteed by combining a high resolution optical encoder with the stepper motor.
For a technical datasheet describing the Agilent Labware MiniHub please visit http://www.chem.agilent.com/Library/datasheets/Public/5990-6670en_lo%20CMS.pdf or contact your local Agilent Automation sales office.
Subscribe to: