World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Thursday, 24 February 2011

Just Published: Analytica Chimica Acta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Online Resource for Food & Beverage Sample Preparation

Genevac has announced a new web page (www.genevac.com/food) that brings together the latest technological innovations, applications advances and references for evaporation and sample concentration techniques relating to food and beverage analysis.

Quality and safety testing of food and beverages is an area of growing importance, be that for exporters, importers or government bodies, accurate analytical results are critical.  In common with many other applications, careful sample preparation is critical, especially when the analyte of interest is volatile.
Genevac evaporator systems find application in a wide array of food and beverage applications from testing constituents of beverages and gluten levels in Whisky, to pesticide analysis of fruit and vegetables as well as determining vitamin levels in cereals.

In nutritional studies, the HCl resistant version of the EZ-2 Evaporator has established itself as a system of choice for protein analysis.  Protein digests often require digestion with 6N HCl which is highly corrosive to traditional evaporation systems, however HCl resistant Genevac systems are designed to withstand daily use of concentrated HCl.

Web links are provided to a bibliography of scientific publications in peer review journals that offer further insight into how modern evaporative sample preparation methods are enabling laboratories accelerate and improve the process of obtaining new compounds from a range of natural product sources.

Genevac, part of the SP Scientific group, was founded in 1990.  Today the company employs around 85 people, with manufacturing, R&D and marketing headquartered in Ipswich, UK. Genevac today offers a comprehensive portfolio of evaporators to suit almost any solvent removal application, purchasing budget or productivity requirement.

For further information please contact Genevac on +44-1473-240000 / +1-845-255-5000 or email salesinfo@genevac.co.uk.

Wednesday, 23 February 2011

HPLC 2011 Dalian Symposium

The HPLC 2011 Dalian Symposium will be held at the Dalian World Expo Center in China from Oct. 8 to 11, 2011. 18th NSEC is almost overlapped with HPLC2011 Dalian. Two conferences will be held in the same building-- the Dalian World Expo Center. You are kindly requested to visit the web site of the symposium http://www.hplc2011.dicp.ac.cn/ where you are able to read relevant information about the meeting all the time. The deadlines for abstract submission are,
31 May 2011
abstract deadline for oral presentations
30 June 2011
abstract deadline for poster presentations
We strongly encourage you to submit abstracts for oral or poster presentation at your earliest convenient time. For more details, please take a look at the call for papers at: http://www.hplc2011.dicp.ac.cn/Abstract_submission.html

The online registration system will be open in March 2011. Then you can also visit the website http://www.hplc2011.dicp.ac.cn/registration.html to complete the online registration. The deadline for early registration is August 15, 2011.

Companies and organizations intending to support the HPLC 2011 Dalian Symposium or to participate in the exhibition are encouraged to download the sponsoring and exhibition form at: http://www.hplc2011.dicp.ac.cn/files/Call%20for%20exhibition%20and%20sponsorship.pdf

If you have any questions, please contact us at hplc_dalian@dicp.ac.cn.
Thank you for your attention, and looking forward to welcoming you personally in Dalian, China in Oct., 2011.

The Organizing and Scientific Committee HPLC 2011 Dalian

(Chairman:
Prof. Yukui Zhang, Prof.Peter Schoenmakers
Co-Chairman:
Prof. Guowang Xu, Prof. Koji Otsuka)

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

KF Coulometric Titrator for Trace Water in Battery Materials

JM Science announces their new AQUACOUNTER® Karl Fischer Coulometric Titrator (AQ-2200S). This new high-end titrator with its excellent capability and upgraded performance is ideal for the trace level water content determination in lithium-ion battery materials with high accuracy using coulometric Karl Fischer titration. Lithium-ion batteries are one of the most popular for portable electronics due to their good energy-to-weight ratios, no memory effect and a slow loss of charge when not in use. Elevated levels of water content in three primary functional components (anode, cathode, electrolyte) may cause degradation in capacity and may reduce the overall lifetime of batteries.

It will be of interest for users who: 1) have many kinds of samples to be analyzed; 2) exchange KF reagents frequently or after each measurement; 3) are eco-minded and budget-conscious.

This titrator allows two titration stations to run parallel with various coulometric/volumetric combinations. With both a volumetric and coulometric channel, one can measure moisture over the entire range from 1 ppm to 100% or double your sample throughput with 2 identical KF stations. The new design is economical and ecological because it reduces the use of expensive KF reagents. Three types of electrolytic cells are available including small volume, standard, and one-room cell. There is an ultra-trace moisture measurement mode equipped in this titrator with an accuracy of ≤10µgH20.   The new cell design allows for easy assembly and maintenance. The new 7.5-inch color touch screen is easy to read and operate. It has enhanced memory capacity and user may store results on a USB memory stick. The stored data can be read out on the color display. Result data with curves may be viewed on a PC internet browsing program with optional software. This titrator comes equipped with a built-in thermal printer with easy paper loading and high resolution printouts. It can be used with peripherals of previous versions.

For more information contact us at 1-800-495-1678 or visit us at http://www.jmscience.com/

Tuesday, 22 February 2011

Just Published: Biosensors & Bioelectronics

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Safe Elemental Analysis Using Schöniger Flask Method

The Oxygen Flask Combustion Unit from Exeter Analytical Inc. provides a highly safe tool for preparing samples for elemental analysis of Halogens, Sulfur, Phosphorus and a number of metals using the Schöniger flask method.
 
The Schöniger flask method is a well proven technique for combusting samples prior to elemental analysis by ion chromatography or titration.  The Schöniger flask method using the attractively priced OFCU-1 is capable of being used for repeatable determination of elemental composition from percentage levels to parts per million.



The durably constructed Oxygen Flask Combustion Unit (OFCU-1) copes easily with a wide range of sample types and is very simple to set up, use and maintain.  Built with operator safety in mind, the OFCU-1 remotely ignites samples inside a safety interlocked chamber using focused infrared heat from two tungsten-halogen lamps. Integral pressure vents ensure safe release of excess reaction pressure.  A thick black acrylic observation window is provided on the OFCU-1 to allow users to visually check ignition has taken place.

As a company dedicated to elemental microanalysis, Exeter Analytical's nearly 30 years of involvement with instruments, consumables and supplies has allowed them to better understand the whole problem facing microanalysts.  As a consequence whether you are a regular or an occasional purchaser - experienced and knowledgeable staff are always available to provide free informed advice.

For further information on the OFCU-1 contact Exeter Analytical on +1-978-251-1411 (+44-2476-323223 in Europe) or email sales@eai1.com.