World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Tuesday, 28 June 2011

Just Published: Analytica Chimica Acta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Microextraction by packed syringe (MEPS): A tutorial

23 June 2011, 21:41:42Go to full article
Publication year: 2011
Source: Analytica Chimica Acta, In Press, Accepted Manuscript, Available online 23 June 2011
Mohamed, Abdel-Rehim
This tutorial provides an overview on a new technique for sample preparation, microextraction by packed syringe (MEPS). Not only the automation process by MEPS is the advantage but also the much smaller volumes of the samples, solvents and dead volumes in the system. Other significant advantages such as the speed and the simplicity of the sample preparation process are provided.In this tutorial the main concepts of MEPS will be elucidated. Different practical aspects in MEPS are addressed. The factors affecting MEPS performance will be discussed. The application of MEPS in clinical and pre-clinical studies for quantification of drugs and metabolites...

Review ofAnalytical Methods for the Quantification of Iodine in Complex Matrices

23 June 2011, 21:41:42Go to full article
Publication year: 2011
Source: Analytica Chimica Acta, In Press, Accepted Manuscript, Available online 23 June 2011
C. Phillip, Shelor , Purnendu K., Dasgupta
Iodine is an essential element of human nutrition. Nearly a third of the global population has insufficient iodine intake and is at risk of developing Iodine Deficiency Disorders. Most countries have iodine supplementation and monitoring programs. Urinary iodide(UI)is the biomarker used for epidemiological studies; only a few methods are currently used routinely for analysis. These methods either require expensive instrumentation with qualified personnel(Inductively coupled plasma-Mass Spectrometry, Instrumental Nuclear Activation Analysis) or oxidative sample digestion to remove potential interferences priorto analysis by a kinetic colorimetric method originally introducedby Sandell and Kolthoff ∼75 years ago. The Sandell-Kolthoff (S-K) method is based on...

A novel silver-coated solid-phase microextraction metal fiber based on electroless plating technique

23 June 2011, 21:41:42Go to full article
Publication year: 2011
Source: Analytica Chimica Acta, In Press, Accepted Manuscript, Available online 23 June 2011
Juanjuan, Feng , Min, Sun , Jubai, Li , Xia, Liu , Shengxiang, Jiang
A novel silver-coated solid-phase microextraction fiber was prepared based on electroless plating technique. Good extraction performance of the fiber for model compounds including phthalate esters (dibutyl phthalate, dioctyl phthalate, dicyclohexyl phthalate and diallyl phthalate) and polycyclic aromatic hydrocarbons (naphthalene, fluorene, phenanthrene, fluoranthene) in aqueous solution was obtained. Under the optimized conditions (extraction temperature, extraction time, ionic strength and desorption temperature), the proposed SPME-GC method showed wide linear ranges with correlation coefficients (R2) ranging from 0.9745 to 0.9984. The limits of detection were at the range of 0.02 to 0.1μgL−1. Single fiber repeatability and fiber-to-fiber reproducibility as well as stability to...

Just Published: Sensors & Actuators A: Physical

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

A Wind-Flutter Energy Converter for Powering Wireless Sensors

25 June 2011, 20:34:09Go to full article
Publication year: 2011
Source: Sensors and Actuators A: Physical, In Press, Accepted Manuscript, Available online 25 June 2011
Fei, Fei , John D., Mai , Wen Jung, Li
This paper describes a low-speed wind energy harvesting system that transfers aerodynamically-induced flutter energy into electrical energy. A random airflow generates mechanical vibrations due to the fluid-structure interaction between a flexible belt and the airflow. An electromagnetic resonator with copper coils and a permanent magnet is designed to efficiently harvest electrical energy from the induced mechanical vibrations. Different groups of springs are compared at various wind conditions to maximize the power output. Typically ∼7 mW of electrical energy can be obtained at ∼3m/s wind speed with a 1 meter long belt. A power conditioning circuit with a charge pump and...

Bonding of carbon nanotubes onto microelectrodes by localized induction heating

25 June 2011, 20:34:09Go to full article
Publication year: 2011
Source: Sensors and Actuators A: Physical, In Press, Accepted Manuscript, Available online 25 June 2011
Mingxiang, Chen , Xiaohui, Song , Qiang, Lv , Zhiyin, Gan , Sheng, Liu
Bonding of carbon nanotubes (CNTs) onto metallic electrodes is achieved by localized induction heating. The contact bonding is formed by inductive heating the electrodes with radio frequency magnetic field. The contact resistance can be reduced by approximate 90% and the reduction is irreversible. It is demonstrated that the induction heating will selectively occurs on the structures with high electronic conductivity and relative permeability, which can be utilized to realize large scale non-contact localized heating. In addition, the atomistic study indicates that the surface charges induced by induction eddy current can improve the wetting properties between the metal atoms and CNT...

Out-of-Box Solution for Managing Lab Information

Micronic has announced a new version 4.6 of its popular Track-IT™ information management system.  Track-IT is a unique out-of-the-box LIMS/LIS solution made for scientists enabling you to reorganize and track your tubes and samples in just minutes.

Fully compatible with most commercial barcode readers, scanners and Tubesorter systems - Track-IT allows you to catalogue and organise samples quickly and efficiently. The central information database produced by Track-IT is customisable to match the workflow of your laboratory, as well as to match the unique aspects of different sample types. Track-IT has been designed to empower laboratory scientists to simply manage sample data and information and make it available to other colleagues in their organisation.

Built around independent modules that can interact with each other, Track-IT 4.6 will manage a wide variety of day-to-day useful lab information. The main concept behind Track-IT is that each scientist in the lab can manage quickly data and information and make it available to the rest of the lab community. Due to Intranet support, data can be accessed from any connected computer in the lab, which accelerates information retrieval. Consequently laboratory staff spends less time on recurrent and time-consuming operations and dedicate more precious time to research activity.

Track-IT allows you to simply import data from existing files into a common presentation, undertake cross database searches, quickly retrieve information and produce reports.  Compliant with CFR 21 Part 11 protocols, Track-IT offers full sample audit traceability.  Combining reliability, efficiency and ease of use with affordability a single Track-IT licence covers all users within an organisation.

To access an online demonstration of Track IT or sign up to a free 30-day trial please visit http://www.micronic.com/products/74/sample-management-database or contact Micronic Europe BV now on +31-320-277070 / sales@micronic.com.

Microplate Sealing Reference Guide

Available from Agilent Automation Solutions - the 'Reference guide to optimal microplate sealing' was written for laboratories looking to optimise microplate sealing processes to safeguard the integrity of their samples. Achieving an optimal microplate seal depends on many factors including microplate design, construction material, batch-to-batch plate production consistency, microplate features, sealing parameters and the type of seal used.

The informative 16-page guide includes a microplate sealing tips section, information on how to optimise sealing parameters when thermal sealing, a comprehensive FAQ section and an electronic PDF form designed to facilitate the capture of key information helpful when requesting technical/applications support.

The free-of-charge reference guide will be of interest to both those currently sealing microplates or those thinking about investing in a microplate sealing instrument.

A copy of `Reference guide for optimal thermal microplate sealing' is available by contacting your local Agilent sales office or downloading the document from http://www.chem.agilent.com/Library/datasheets/Public/5990-3483EN_LO.pdf.

Monday, 27 June 2011

Just Published: Sensors & Actuators B: Chemical

Selected papers from the latest issue:

Metal (Pd, Pt)-Decorated Carbon Nanotubes for CO and NO Sensing

25 June 2011, 23:06:52Go to full article
Publication year: 2011
Source: Sensors and Actuators B: Chemical, In Press, Accepted Manuscript, Available online 25 June 2011
Kunjie, Li , Wenchuan, Wang , Dapeng, Cao
Using the first-principles calculations, we investigated adsorption of CO and NO gas molecules on the Pd- and Pt-decorated single-walled carbon nanotube (SWNT). The metal-decorated SWNTs exhibit strong affinity toward the gas molecules. Our results reveal that the CO and NO gas molecules can be chemisorbed on the Pd or Pt atom, accompanying with the large binding energy and significant charge transfer. Adsorption of these gases would affect the electronic conductance of the materials, which can serve as a signal of gas sensor. In particular, adsorption of NO generates the magnetic properties to the metal-decorated SWNT, which can also serve as...

Highly sensitive label-free immunosensor for ochratoxin A based on functionalized magnetic nanoparticles and EIS/SPR detection

25 June 2011, 23:06:52Go to full article
Publication year: 2011
Source: Sensors and Actuators B: Chemical, In Press, Accepted Manuscript, Available online 25 June 2011
Lucian-Gabriel, Zamfir , Irina, Geana , Sondes, Bourigua , Lucian, Rotariu , Camelia, Bala , ...
A label-free immunosensor for the detection of ochratoxin A (OTA) based on use of magnetic nanoparticles (MNPs) was developed. A gold electrode was modified using bovine serum albumin conjugate with a glutaraldehyde-thiolamine linker, creating a layer that prevents non-specific binding of OTA on gold. The OTA antibodies were attached to MNPs using the carbodiimide chemistry and afterwards were immobilized on the modified gold electrode using a strong magnetic field. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and surface plasmon resonance (SPR) were used to characterize each step in immunosensor development. The impedance variation due to the specific antibody-OTA interaction was...

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Direct Aqueous Determination of Glyphosate and Related Compounds by Liquid Chromatography/Tandem Mass Spectrometry using Reversed-Phase and Weak Anion-Exchange Mixed-mode Column

26 June 2011, 20:29:50Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 26 June 2011
Chunyan, Hao , David, Morse , Franca, Morra , Xiaoming, Zhao , Paul, Yang , ...
Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS-MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12minutes with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in...

Analysis of primary aromatic amines in the mainstream waterpipe smoke using liquid chromatography—electrospray ionization tandem mass spectrometry

26 June 2011, 20:29:50Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 26 June 2011
Jens, Schubert , Oliver, Kappenstein , Andreas, Luch , Thomas G., Schulz
In recent years waterpipe smoking has spread worldwide and emerged as global health issue. Yet only little is known on the composition of waterpipe smoke. Here, we present a study on the identification and quantification of primary aromatic amines (PAAs) in this complex environmental matrix. Smoking of the waterpipe was conducted with a smoking machine and particulate matter was collected on glass fiber pads. We developed a fast, simple and specific liquid chromatography—electrospray ionization tandem mass spectrometry (LC-MS/MS) approach to simultaneously detect 31 different PAAs in this matrix. The detection limits comprised a range of 0.45ng to 4.50ng per smoking...

Selective extraction of alkaloids in human urine by on-line single drop microextraction coupled with sweeping micellar electrokinetic chromatography

26 June 2011, 20:29:50Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 26 June 2011
Wenhua, Gao , Gaopan, Chen , Yaowen, Chen , Nana, Li , Tufeng, Chen , ...
A novel method of on-line single drop microextraction (SDME) coupled with sweeping micellar electrokinetic chromatography (MEKC) for the selective extraction and dual preconcentration of alkaloids was developed. In this technique, analytes of three alkaloids were firstly extracted from 4.0mL basic aqueous sample solution (donor phase, 500mM NaOH) into a layer of n-octanol at temperature 30 ∘C with the stirring rate of 1150rpm, then back-extracted into the acidified aqueous acceptor (acceptor phase, 50mM H3PO4) suspended at the tip of a capillary at 650rpm. After then, the aqueous acceptor was introduced into capillary by hydrodynamic injection with a height difference of 15cm...

Acrylate ester-based monolithic columns for capillary electrochromatography separation of triacylglycerols in vegetable oils

26 June 2011, 20:29:50Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 26 June 2011
M.J., Lerma-García , M., Vergara-Barberán , J.M., Herrero-Martínez , E.F., Simó-Alfonso
A simple and reliable method for the evaluation of triacylglycerols (TAGs) in vegetable oils by capillary electrochromatography (CEC) with UV-Vis detection, using octadecyl acrylate (ODA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained at the following ratios: 40:60% (wt/wt) monomers/porogens, 60:40% (wt/wt) ODA/1,3-butanediol diacrylate and 23:77% (wt/wt) 1,4-butanediol/1-propanol (14 wt% 1,4-butanediol in the polymerization mixture). A satisfactory resolution between TAGs was achieved in less than 12min with a 65:35 (v/v) acetonitrile/2-propanol mixture containing 5mM ammonium acetate. The method was applied...

Reproducible and Quantifiable Directed In Vivo Angiogenesis Assessment Assays

AMSBIO has announced a new range of Directed in vivo Angiogenesis Assay (DIVAA™) kits that address the short-comings of the traditional plug assay by controlling the site for angiogenesis, increasing reproducibility, conserving test compounds, and supplying more statistical data for quantitative analysis. This range of kits is designed to test for activation, inhibition and tube formation.

The Directed In Vivo Angiogenesis Assay (DIVAA™) is the first in vivo system for the study of angiogenesis that provides quantitative and reproducible results. The DIVAA kits provide implant grade silicone cylinders closed at one end, called angioreactors. The angioreactors are filled with 20 microlitres of AMSBIO's Basement Membrane Extract (BME) premixed with or without angiogenesis modulating factors. These angioreactors are then implanted subcutaneously in the dorsal flanks of nude mice. With the onset of angiogenesis, cellular vascularization proceeds to invade the angioreactor, and as early as nine days post-implantation, there are enough cells to determine an effective dose response to angiogenic modulating factors. The sleek design of the patented angioreactor optimizes sensitivity and allows for up to four units per mouse, giving a more controlled experiment and decreasing the number of mice required for a study.

Tumour cells can be implanted into the angioreactor, to study their angiogenic effects in an in vivo system. AMSBIO's DIVAA Kit is provided with FITC-Lectin for fluorescent quantitative analysis. Optional protocols are available for analysis with Calcein-AM and Dextran-FITC.

For further information please visit www.amsbio.com/in-vivo-Angiogenesis-Assay-kits-DIVAA.aspx or contact AMSBIO on +44-1235-828200 / +1-949-768-8365 or email info@amsbio.com