World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Friday, 15 July 2011

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Papers selected frm the latest issue:

Planar solid phase extraction – a new clean-up concept in multi-residue analysis of pesticides by liquid chromatography–mass spectrometry

14 July 2011, 20:40:55Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 13 July 2011
Claudia, Oellig , Wolfgang, Schwack
Efficient clean-up is indispensable for preventing matrix effects in multi-residue analysis of pesticides in food by liquid and gas chromatography coupled to mass spectrometry. As a completely new approach, highly automated planar chromatographic tools were applied for powerful clean-up, called high-throughput planar solid phase extraction (HTpSPE). Thin-layer chromatography (TLC) was used to completely separate pesticides from matrix compounds and to focus them into a sharp zone, followed by extraction of the target zone by the TLC–MS interface. HTpSPE resulted in extracts nearly free of interference and free of matrix effects, as shown for seven chemically representative pesticides in four different...

Zwitterionic-type hydrophilic interaction nano-liquidchromatography of complex and high mannose glycans coupled with electrospray ionisationhigh resolution time of flight mass spectrometry

13 July 2011, 20:42:22Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 12 July 2011
Lea, Mauko , Matthias, Pelzing , Sebastiaan, Dolman , Anna, Nordborg , Nathan A., Lacher , ...
In this study we describe a new method for rapid and sensitive analysis of reduced high mannose and complex glycans using zwitterionic-type hydrophilic interaction nano-liquid chromatography (nanoZIC-HILIC, 75μm I.D. x 150mm) coupled with high resolution nanoelectrospray ionisation time of flight mass spectrometry (nano ESI-TOF-MS).The retention of neutral glycans increases with increasing molecular weight and is higher for high mannose glycans than for complex-type glycans. The selectivity of ZIC-HILIC for sialylatedglycans differs from that for the neutral glycans and is believed to involve electrostatic repulsion; therefore charged glycans are eluted earlier than neutral glycans with comparable molecular weight. Due to the...

Modelling of Elution-Extrusion Counter-current Chromatography using perfect replacement approach

13 July 2011, 20:42:22Go to full article
Publication year: 2011
Source: Journal of Chromatography A, In Press, Accepted Manuscript, Available online 12 July 2011
Artak E., Kostanyan
Basing on the perfect replacement approach the equilibrium cell model is developed to describe the separation process in elution-extrusion countercurrent chromatography (EECCC). As is known, EECCC consists of three steps: classical elution, sweeping elution, and extrusion. The perfect replacement approach means that during sweeping elution step, the mobile phase contained in the column moves and interacts with the “old” stationary phase in the same mode as during the classical elution step; the “new” and “old” stationary phases do not mix; and after the contacting with the mobile phase the concentration of solutes in the “old” stationary phase remains constant and...

Thursday, 14 July 2011

Just Published: Chemometrics and Intelligent Laboratory Systems

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
A paper from the latest issue:

Performance assessment of the anticipatory approach to optimal experimental design for model discrimination

13 July 2011, 21:32:59Go to full article
Publication year: 2011
Source: Chemometrics and Intelligent Laboratory Systems, In Press, Accepted Manuscript, Available online 12 July 2011
Brecht M.R., Donckels , Dirk J.W., De Pauw , Peter A., Vanrolleghem , Bernard, De Baets
The problem of model discrimination arises when several models are proposed to describe one and the same process, a situation encountered in many research fields. To identify the best model from the set of rival models, it may be necessary to collect new information about the process, and thus additional experiments have to be performed. Several approaches have been described in literature to design optimal discriminatory experiments. The anticipatory approach is one of them and is very appealing from a conceptual point of view because the expected information content of the newly designed experiment is considered, even before the experiment...

Video Demonstrates How Easy DLS Has Become

A new video from Avid Nano demonstrates how easy making precise DLS measurements has become using their W130i dynamic light scattering system with patent pending 5µl BladeCell™ disposable cuvettes.

Available to view at http://www.avidnano.com/media/media.htm the video demonstrates the simple 4 step protocol (Load...Measure...Recover...Dispose) that has made low volume batch DLS measurements faster, easier and more convenient than ever before.
 
Engineered to meet the demands of today's research laboratories, the Avid Nano W130i dynamic light scattering system delivers outstanding performance from only 5µl of sample in seconds. The W130i combines ultimate measurement performance with an economical benchtop footprint, rugged durability and supreme user convenience.
 
The patent-pending 5µl BladeCell™ cuvette combines the ultimate convenience of a disposable sample holder with the measurement quality of a quartz cuvette.  To fill 5µl of sample is simply pipetted against the walls of the BladeCell liquid trap where it is retained by surface tension.  The prepared cuvette is placed into the temperature controlled sample holder of the Avid Nano W130i, where it can be analysed by DLS in just seconds.  After analysis the sample is recovered by simply dipping a pipette tip into the liquid trap and removing the contents.  As a low cost cuvette the BladeCell may now be disposed of eliminating the cleaning steps required when using more costly quartz cuvettes.

Operating from its UK headquarters - Avid Nano is building a strong reputation for its technical expertise, applications support and delivering DLS systems that reliably deliver top quality results.  For further information on improving your DLS productivity and measurement quality please contact Avid Nano on +44-1494-614659 or email info@avidnano.com.

Wednesday, 13 July 2011

Automated Production of High Quality Blood Agar

INTEGRA has released a new application note that demonstrates how combining its MEDIAJET Petri dish filler with the DOSE IT peristaltic pump provides an optimised automated solution for the production of high quality blood agar.

The quality of blood agar plates is of prime importance for the reliable determination of haemolysis type - a common technique in medical diagnostics to classify Gram positive cocci. High quality agar plates have a typical light red colour - a characteristic feature of intact erythrocytes. Agar plates with lysed red blood cells appear brown coloured, a feature that complicates the reading of haemolysis pattern. To avoid spontaneous lysis of erythrocytes, it is important to keep the temperature of the agar as low as possible. In addition to minimise cell lysis, the time the blood remains in the hot agar has to be as short as possible. Meeting these requirements is a challenge for most laboratories.

The new application note describes an automated protocol that minimizes the time that the blood is exposed to hot agar medium and thus efficiently reduces thermally induced lysis of erythrocytes. By preparing the blood agar using an INTEGRA MEDIACLAVE media preparator, the dispensing temperature can be set and maintained at low temperature. Furthermore by combining the MEDIAJET Petri Dish filler together with a DOSE-IT peristaltic pump and a special tubing set for blood agar the experimenters were able to add blood to the agar immediately before pouring the plate thereby reducing blood cell lysis significantly.

For a copy of this application note visit http://www.blogger.com/www.integra-biosciences.com/pdf/liquid_handling/Blood_agar_preparation_V00.pdf or contact INTEGRA on +41-81-286-9530 / info@integra-biosciences.com (Europe / Asia Pacific) or +1-603-578-5800 / contact@viaflo.com (North / South America).

Just Published: Spectrochimica Acta Part B: Atomic Spectroscopy

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers  from the latest issue:

European Symposium on Atomic Spectrometry (ESAS 2010), Wrocław, Poland 5–8 September 2010☆

09 July 2011, 21:23:09Go to full article
Publication year: 2011
Source: Spectrochimica Acta Part B: Atomic Spectroscopy, In Press, Accepted Manuscript, Available online 8 July 2011
Ewa, Bulska

Characterization of Argon metastable species as function of time, space, and current of a pulsed DC Glow Discharge

06 July 2011, 21:32:18Go to full article
Publication year: 2011
Source: Spectrochimica Acta Part B: Atomic Spectroscopy, In Press, Accepted Manuscript, Available online 6 July 2011
G., Lotito , T., Nelis , Ph., Guillot , D., Günther
Optical measurements performed through an iCCD camera equipped with an optical bandpass filter have been carried out on a pulsed DC Glow Discharge (GD) in order to study the spatial, temporal, and current dependency of the 1s5 (3P2) Ar metastable (Ar*) species. For the spatial and temporal study the pressure was held constant at 1hPa. The combination of the iCCD camera with the bandpass filter has allowed to acquire time-resolved images of the Ar* in a spatial region between the cathode and the anode. Those measurements have been performed through optical emission and absorption spectroscopy and have shown that the...

Tuesday, 12 July 2011

Automated Production of High Quality Blood Agar

INTEGRA has released a new application note that demonstrates how combining its MEDIAJET Petri dish filler with the DOSE IT peristaltic pump provides an optimised automated solution for the production of high quality blood agar.

The quality of blood agar plates is of prime importance for the reliable determination of haemolysis type - a common technique in medical diagnostics to classify Gram positive cocci. High quality agar plates have a typical light red colour - a characteristic feature of intact erythrocytes. Agar plates with lysed red blood cells appear brown coloured, a feature that complicates the reading of haemolysis pattern. To avoid spontaneous lysis of erythrocytes, it is important to keep the temperature of the agar as low as possible. In addition to minimise cell lysis, the time the blood remains in the hot agar has to be as short as possible. Meeting these requirements is a challenge for most laboratories.
 
The new application note describes an automated protocol that minimizes the time that the blood is exposed to hot agar medium and thus efficiently reduces thermally induced lysis of erythrocytes.  By preparing the blood agar using an INTEGRA MEDIACLAVE media preparator, the dispensing temperature can be set and maintained at low temperature.  Furthermore by combining the MEDIAJET Petri Dish filler together with a DOSE-IT peristaltic pump and a special tubing set for blood agar the experimenters were able to add blood to the agar immediately before pouring the plate thereby reducing blood cell lysis significantly. 

For a copy of this application note visit www.integra-biosciences.com/pdf/liquid_handling/Blood_agar_preparation_V00.doc or contact INTEGRA on +41-81-286-9530 / info@integra-biosciences.com  (Europe / Asia Pacific) or +1-603-578-5800 / contact@viaflo.com (North / South America).

Lyophilization Cycle Development & Optimization

SP Scientific has announced, in response to widespread enthusiastic participant response to its previous hands-on laboratory training courses in freeze drying techniques, new dates for a Fall 2011 programme.

Running from October 11-13th 2011 the 'Lyophilisation Cycle Development & Optimization: A Laboratory Based Approach'  training course will focus on following the freeze drying process from formulation and thermal analysis to cycle development, optimization, packaging and troubleshooting.  Organised and run by a panel of internationally acknowledged experts in association with SP Scientific, the hands-on training course will enable attendees to optimize their learning experience by using real applications in a controlled setting.

Cindy Reiter - Director of Marketing at SP Scientific commented "As you can see from testimonials on our website - participants on previous courses have responded enthusiastically to the in-depth nature of the seminars and how they are presented in an understandable way and brought to life with hands-on laboratory sessions". 

Past participant feedback and the program for the Fall 2011 hands-on training courses is available by visiting  www.spscientific.com/LabTraining or by contacting SP Scientific on +1-845-255-5000 x2445 / cindy.reiter@spscientific.com.