AirClean Systems AC600 Series chemical workstations

AirClean Systems AC600 Series chemical workstations offer flexibility and mobility for today’s ever changing laboratory environment.

The AC600 Series of ductless chemical workstations are designed to provide a low cost solution for protection of the operator and environment from toxic vapors, gases, fumes and particulate when performing low-volume applications with known chemicals. While smaller and more mobile than a traditional or ductless fume hood, AC600 Series chemical workstations include the same advanced safety features and technology as their larger brethren – gas phase bonded carbon filtration, real-time gas detection and constant airflow control and monitoring.

AirClean® Systems ductless fume hoods and chemical workstations utilize gas phase bonded carbon filtration, providing higher capacity and eliminating filter ‘dusting’ caused by traditional granular carbon filters. In addition to standard formulations, multi-layered and chemically-impregnated filters are available to increase load capacity. AC600 Series workstations can even be configured with multiple carbon and HEPA filters.

The AirSafe™ automatic safety controller, a standard feature on all AC600 Series workstations, displays, monitors and maintains proper airflow to ensure fumes and vapors do not enter the operator’s breathing zone. Regardless of sash position, the microprocessor-based controller will automatically raise or lower the blower speed to maintain the user-set face velocity. In addition to monitoring and controlling airflow, AirSafe monitors gas phase filtration, providing both audible and visible alarms once saturation reaches the alarm set-point.

AC600 Series workstations can be placed virtually anywhere within the laboratory with the only installation requirement being access to a standard power outlet. Each workstation is available with an optional sturdy cart, allowing flexibility and mobility within the laboratory. AC600 Series workstations are self contained, fully assembled, factory tested and certified before shipment.

Typical applications include general chemistry involving small volumes of common chemicals, tissue staining, gluing operations, cleaning and polishing of parts, sample preparation, soldering applications and a variety of other common laboratory manipulations and formulations

AirClean Systems AC600 Series ductless chemical workstations are proudly manufactured in Raleigh, NC USA.

For more information on AirClean Systems’ ductless chemical workstations or fume hoods, visit our website at http://www.aircleansystems.com/ or contact our Technical Sales Department at 919-255-3220 or 800-849-0472.

Monday, 27 February 2012

Just Published: Analytica Chimica Acta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Nonenzymatic glucose sensor based on CuO microfibers composed of CuO nanoparticles

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 25 February 2012
Fei Cao, Jian Gong
Fluorine tin oxide (FTO) electrode modified by copper oxide microfibers (CuO-MFs) composed of numerous interconnected CuO nanoparticles (CuO-NPs) for nonenzymatic glucose sensor was prepared by electrospinning precursor containing high percentage content of copper nitrate with subsequent calcination. The results of scanning electron microscope (SEM) showed the size of CuO particles composing CuO-MFs depended on the percentage content of copper nitrate in precursor solution. With increasing the percentage content of copper nitrate, the interconnected CuO-NPs would gradually replace the large-size CuO particles to accumulate the CuO-MFs, which have the potential to provide larger surface area and more reaction sites for electrocatalytic activity toward glucose. As a glucose sensor, the CuO-MFs modified FTO electrode prepared by 40 wt.% of copper nitrate exhibited a high sensitivity of 2321 μA mM cmwith a low detection limit of 2.2 nM (signal/noise ratio (S/N) = 3). Additionally, the application of the CuO-MFs modified FTO electrode as a glucose sensor for biological samples was demonstrated with satisfactory results.

Highlight

► Electrospinning CuO microfibers onto electrodes as glucose sensors were studied. ► The CuO microfibers were composed of CuO particles. ► Size of CuO particles relies on percentage content of copper nitrate in precursor. ► Performance of the sensor depends on size of CuO particles.

Electrochemical sensor for naphthols based on gold nanoparticles/hollow nitrogen-doped carbon microsphere hybrids functionalized with SH-β-cyclodextrin

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 25 February 2012
Gangbing Zhu, Pengbo Gai, Yan Yang, Xiaohua Zhang, Jinhua Chen
Due to awfully harmful to the environment and human health, the qualitative and quantitative determinations of naphthols [1-naphthol (1-NAP) and 2-naphthol (2-NAP)] are of great significance and receive great attention. In this paper, gold nanoparticles (Au NPs)/hollow nitrogen-doped carbon microspheres (HNCMS) hybrids (Au NPs/HNCMS) were prepared and functionalized with thiolated-β-cyclodextrin (HS-β-CD) for the first time, and then applied successfully in sensitive and simultaneous electrochemical detection of naphthols. The results show that the oxidation peak currents of naphthols obtained on the HS-β-CD/AuNPs/HNCMS modified glassy carbon (GC) electrode are much higher than that on the AuNPs/HNCMS/GC, HNCMS/GC and bare GC electrodes. Additionally, compared with other electrochemical sensors developed previously, the proposed electrode results in improved detection limits of about four times for 1-NAP (1.0 nM) and two orders of magnitude for 2-NAP (1.2 nM). The linear response ranges of 1-NAP and 2-NAP are both 2–150 nM.

Highlights

► HS-β-CD/Au NPs/hollow nitrogen-doped carbon microspheres hybrids were synthesized. ► A new electrochemical sensor for naphthols was developed based on the prepared hybrids. ► The sensor shows good analytical performance for simultaneous detection of naphthols.

Glucose Biosensor Based on Three Dimensional Ordered Macroporous Self-doped Polyaniline/Prussian Blue Bicomponent Film

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 24 February 2012
Xiaojun Chen, Zixuan Chen, Rong Tian, Wei Yan, Cheng Yao
In this paper, a three dimensional ordered macroporous self-doped polyaniline/Prussian blue (3DOM SPAN/PB) bicomponent film was fabricated via the inverted crystal template technique using step-by-step electrodeposition. In this bicomponent film, PB not only acted as a redox mediator, but also presented increased stability in neutral or weak alkaline solution by the protection of SPAN layer on the top. A novel glucose biosensor was fabricated based on the large active surface area and excellent conductivity possessed by the 3DOM SPAN/PB film. The applying experimental conditions of the glucose biosensor have been optimized. Under the optimal conditions, the biosensor showed a wide linear range over three orders of magnitude in glucose concentrations (from 2 to 1600 μM) and a low detection limit of 0.4 μM. Moreover, the biosensor exhibited short response time, high selectivity and excellent operation stability, which can be applied to detect the blood sugar in real samples without any pretreatment.

Highlights

► A 3D ordered macroporous self-doped polyaniline/Prussian blue film was prepared. ► In the film, PB revealed good stability in neutral and weak alkalescent solution. ► A novel glucose biosensor was fabricated based on the 3DOM bicomponet film. ► The biosensor showed a linear range of 2-1600 μM and a detection limit of 0.4 μM. ► The biosensor can detect the blood sugar in real samples without any pretreatment.

Detection of influenza A virus based on fluorescence resonance energy transfer from quantum dots to carbon nanotubes

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 24 February 2012
Junping Tian, Huimin Zhao, Meng Liu, Yaqiong Chen, Xie Quan
In this paper, a simple and sensitive approach for H5N1 DNA detection was described based on the fluorescence resonance energy transfer (FRET) from quantum dots (QDs) to carbon nanotubes (CNTs) in a QDs-ssDNA/oxCNTs system, in which the QDs (CdTe) modified with ssDNA were used as donors. In the initial stage, with the strong interaction between ssDNA and oxCNTs, QDs fluorescence was effectively quenched. Upon the recognition of the target, the effective competitive bindings of it to QDs-ssDNA occurred, which decreased the interactions between the QDs-ssDNA and oxCNTs, leading to the recovery of the QDs fluorescence. The recovered fluorescence of QDs was linearly proportional to the concentration of the target in the range of 0.01-20 μM with a detection limit of 9.39 nM. Moreover, even a single-base mismatched target with the same concentration of target DNA can only recover a limited low fluorescence of QDs, illustrating the good anti-interference performance of this QDs-ssDNA/oxCNTs system. This FRET platform in the QDs-ssDNA/oxCNTs system was facilitated to the simple, sensitive and quantitative detection of virus nucleic acids and could have a wide range of applications in molecular diagnosis.

Highlights

► The quantum dots-ssDNA probe was designed for the determination of virus DNA; ► The fluorescence of quantum dots was effectively quenched by carbon nanotubes; ► The addition of target H5N1 DNA restored the quenched fluorescence of quantum dots; ► The proposed method exhibited high sensitivity and good selectivity for H5N1 DNA.

A colorimetric and Surface-enhanced Raman scattering dual-signal sensor for Hgbased on Bismuthiol II-capped gold nanoparticles

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 24 February 2012
Junling Duan, Min Yang, Yongchao Lai, Jingpeng Yuan, Jinhua Zhan
The addition of Bismuthiol II to the gold nanoparticles (AuNPs) solution led to the aggregation of AuNPs with a color change from red to blue. As a result, hot spots were formed and strong surface-enhanced Raman scattering (SERS) signal of Bismuthiol II was observed. However,the Bismuthiol II-induced aggregation of AuNPs could be reversed by Hgin the system, accompanied by a remarkable color change from blue to red. As evidenced by UV-vis and SERS spectroscopy, the variation in absorption band and SERS intensity was strongly dependent on the concentration of Hg, suggesting a colorimetric and SERS dual-signal sensor for Hg. The sensor had a high sensitivity, low detection limits of 2 nM and 30 nM could be achieved by UV-vis spectroscopy and by SERS spectroscopy, respectively. Other environmentally relevant metal ions did not interfere with the detection of Hg. The method was successfully applied to detect Hgin water samples. It was simple, rapid and cost-effective without any modifying or labeling procedure.

Highlights

► A dual-signal sensor for Hgwas developed by mixing Bismuthiol II and AuNPs. ► Colorimetric sensing was achieved based on the Hg-inhibited aggregation of AuNPs. ► Hot spots were formed with the aggregation of AuNPs, allowing SERS detection. ► The method showed high sensitivity and selectivity.

Electrochemical detection of a powerful estrogenic endocrine disruptor: ethinylestradiol in water samples through bioseparation procedure

25 February 2012, 22:52:23Go to full article
Publication year: 2012
Source: Analytica Chimica Acta, Available online 24 February 2012
Noelia A. Martínez, Sirley V. Pereira, Franco A. Bertolino, Rudolf J. Schneider, Germán A. Messina, ...
The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV).This method can be used to determine EE2 in the range of 0.035–70 ng Lwith a detection limit (LOD) of 0.01 ng Land R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels.

Highlights

► We developed an electrochemical method for the determination of ethinylestradiol in water samples. ► Modified magnetic particles were employed for the bioseparation and preconcentration procedures. ► The use of magnetic particles offers high selectivity due to antigen-antibody binding specificity. ► The detection was carried out by using a glassy carbon electrode modified with carbon nanotubes.

NEW CO2 Data Logger with Temperature & Humidity!

The NEW "CO2 Recorder TR-76Ui" from TandD Corp. is a three-channel data logger designed to simultaneously measure and record CO2 concentration, temperature and humidity.
Making atmospheric pressure settings for the measurement location ensures more stable and accurate CO2 measurements.
The unit has a CO2 range up to 5,000 ppm and a capacity to store up to 8,000 data sets.
The supplied software enables the user to download data recorded by TR-76Ui to a PC via USB connection, whereby data from all three channels can be simultaneously viewed in graph or table form.
By using a handheld Data Collector TR-57DCi (sold separately) with graphical display, it is possible to collect recorded data from the TR-76Ui via infrared communication and immediately check the collected data on the spot.
For monitoring in locations where electrical outlets are not available, this unit can also measure and record when operating under battery power. The product is an all-in-one package that includes the data logger unit, sensors, USB cable, batteries and software.
For additional information on this NEW unit contact:
TandD CorporationPO Box 321
Saratoga Springs, NY 12866 USA
Phone: 518-669-9227
E-mail: inquiries@tandd.com
Web: http://www.tandd.com/


Friday, 24 February 2012

Just Published: Sensors & Actuators A: Physical

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Numerical study of a ferrule-top cantilever optical fiber sensor for wind-tunnel applications and comparison with experimental results

22 February 2012, 21:56:07
Publication year: 2012
Source: Sensors and Actuators A: Physical, Available online 22 February 2012
A. Cipullo, G. Gruca, K. Heeck, F. De Filippis, D. Iannuzzi, ...
We present a numerical analysis of an air flow velocity sensor based on a fiber-optic ferrule-top cantilever. The device forms a low-finesse Fabry-Perot interferometer, with one of the two reflecting surfaces constituted by a cantilever beam. Under the effect of the flow pressure, the cantilever bends producing a change in the cavity length of the Fabry-Perot and therefore a modification of its optical response. The numerical analysis, performed by use of finite-element method (FEM), is then compared with a set of experimental results obtained in a small wind-tunnel.

Silicon linkage with novel compliant mechanism for piezoelectric actuation of an intraocular implant

22 February 2012, 21:56:07
Publication year: 2012
Source: Sensors and Actuators A: Physical, Available online 22 February 2012
Th. Martin, U. Gengenbach, H. Guth, P. Ruther, O. Paul, ...
An implantable mechatronic microsystem is a new approach to restore the accommodation ability of the human eye. For change of refractive power a lens shift is performed by an actuator. This paper reports on the first actuator solution for such an implant. It is based on a piezoelectric bender the displacement of which has to be amplified on a very limited design space to sufficiently drive the optics of an Artificial Accommodation System. This challenge is solved by a novel compliant mechanism in single-crystal silicon that additionally ensures a linear displacement of the lens required for optical imaging quality. The design is free of any surface-friction to achieve high durability. Finite element analysis is conducted to calculate and optimize the performance of three linkage design variants. They were fabricated on a scale of 1.5:1 using deep reactive ion etching. Measurements were carried out to characterize the geometry, elastic behavior, and kinematic performance of the linkage samples. The results are in very good agreement with the calculations and indicate sufficient amplification of the piezoelectric bender's displacement by the linkage to generate the required lens shift.

Ku-band bandpass filters using novel micromachined substrate integrated waveguide structure with embedded silicon vias in benzocyclobutene dielectrics

22 February 2012, 21:56:07
Publication year: 2012
Source: Sensors and Actuators A: Physical, Available online 21 February 2012
Ik-Jae Hyeon, Woo-Young Park, Sungjoon Lim, Chang-Wook Baek
In this paper, Ku-band bandpass filters (BPFs) based on a novel micromachined substrate integrated waveguide (SIW) platform with square complementary split-ring resonators (CSRRs) have been demonstrated. The proposed SIW platform adopts embedded metal-coated silicon vias in benzocyclobutene (BCB) dielectric substrate filled into a silicon trench. Unlike conventional SIW BPFs using classical microwave substrates, the proposed BPFs can be integrated with silicon-based circuits or RF MEMS devices since the fabrication process is fully compatible with the silicon process while providing low-loss properties of the waveguide. Three types of BPFs using CPW and microstrip feeding configurations have been designed and fabricated. The microstrip-fed BPF using the same CSRRs shows an improved insertion loss of 1.39 dB at 13.8 GHz with reduced device size compared to the CPW-fed BPF which has an insertion loss of 2.27 dB at 14.1 GHz. The microstrip-fed BPF with different CSRR configurations designed to improve shape factor shows an attenuation factor of 124 dB/GHz, with an insertion loss of 2.3 dB at 21.2 GHz.

Effects of wire properties on the field-tunable behaviour of continuous-microwire composites

22 February 2012, 21:56:07
Publication year: 2012
Source: Sensors and Actuators A: Physical, Available online 21 February 2012
F.X. Qin, H.X. Peng, M.H. Phan, L.V. Panina, M. Ipatov, ...
The microwire composites consisting of continuous Co-rich amorphous glass-coated ferromagnetic microwires embedded in a E-glass prepreg matrix were fabricated, and the influences of wire periodicity (b), composition and radius on the field-tunable properties have been systematically investigated in a broad microwave frequency range of 0.9–18 GHz. It has been found that the field tunability, effective operational frequency and field of the composites are strongly dependent on these factors. With decreasingbfrom 15 to 7 mm, the field tunability of effective permittivity (nɛ) increases from 0.77% to 16% m/A by more than 20 times. The detected cups and resonances of the transmission and reflection spectra are identified. Their changes with wire periodicity have been shown to be due to a combination of the dielectric and magnetic response arising from the interactions between microwave and microwires and microwires by themselves. The best possible field tunability occurs below the plasma frequency. The effective magnetic field for realisation of the field-tunable properties has been found to be about 500 A/m, which is associated with the anisotropy field. In addition, field tunability is found to be positively correlated with the magnetic softness and GMI properties of the wire fillers, which are determined by the wire composition and geometry. These findings are of practical importance in developing multifunctional microwire composites for a broad range of engineering applications, such as structural health monitoring, NDT and microwave tunable devices.

Highlights

► Exhaustive presentation and analyses of the influences of wire periodicity (b), composition and radius on the field-tunable properties ► Plasma frequency, field tunability and effective operation frequency range can be modulated via fine-tuning the local properties and arrangements of wires ► Detailed and comprehensive comparison is performed for feature differences in all electromagnetic spectra due to the variation of the wire parameters.


Porvair Sciences Announces 2012 Microplate Catalogue

Many scientists around the world have come to rely upon the Porvair Sciences Catalogue as a primary source of information that enables them to choose the optimum microplate or tissue culture consumable for their application.

The new 2012 edition brings together information on Porvair Sciences comprehensive microplate and microplate instruments product range, together with a recently introduced range of high quality epigenetics and tissue culture plastics. Reflecting Porvair's continuing commitment to continuous technological innovation, the 2012 catalogue introduces a suite of exciting new products.

Featured for the first time are Porvair's new manual Pin Tools - disposable replicators for 96 and 384 well plate replication. We've expanded our range of colour-coded sealing film and introduced a next generation Miniseal II semi-automatic microplate sealer.

But perhaps the most exciting innovation for 2012 is the launch of Ultravap RC - Porvair's all new robot-compatible nitrogen blown down station. For many years, Porvair Sciences has led the field in nitrogen blow down evaporation. This new version of Porvair's most popular concentrator makes it even easier to integrate an automatic dry down step into your automated liquid handling protocol.

Add to this an expanded range of SPE plates, more protein removal options and a competitively priced range of high quality tissue culture products and you will see that the 2012 catalogue remains an indispensable reference guide to any laboratory using, or interested in using, microplates.

Established in 1992, Porvair Sciences Ltd. has developed internationally recognised expertise in microplate technology and manufacturing serving applications in Drug Discovery, Combinatorial Chemistry, Solid Phase Extraction, Protein Purification, High Throughput Screening, Environmental Analysis, Proteomics and Genomics.   Porvair Sciences Ltd. is a wholly owned subsidiary of Porvair plc.

For a copy of the 2012 catalogue please visit www.porvair-sciences.com or contact Porvair Sciences Ltd. on +44-1372-824290 / int.sales@porvair-sciences.com  


Cryogenic Storage Rack for High Volume Samples

Durably constructed the thick-walled Arctic Rack-24 from Micronic is a new rack and cover enabling high integrity sample storage at ultra low (cryogenic) temperatures over extended periods of time.

The Arctic Rack-24 is purpose designed to accommodate twenty four high volume (6.00ml or 7.50ml) Micronic storage tubes in an automation-friendly SBS** footprint. A special cover enables the Arctic Rack-24 to be securely locked ensuring high sample security during transport or storage.

The Arctic Rack-24 may be autoclaved several times providing considerable cost savings over consumable sample storage products. Absolute traceability and reproducibility on the Arctic Rack-24 are ensured through alphanumeric visual location aids and laser engraved barcodes on 2 sides of the rack plus rack foot mounting points. The open bottom design of the Arctic Rack-24 facilitates quick defrosting of samples. To conserve valuable storage space within freezers or when transporting the Arctic Rack-24 with covers are stackable. Opening is achieved by simply moving the locker at each end of the cover downwards then squeezing upwards.

All Micronic racks and tubes are manufactured under US Federal Standard 209E Class 7 clean room conditions. Dedicated to the design and production of innovative sample storage tubes, accessories and instruments over the last 25 years, Micronic is uniquely able to offer labs the expert advice to help them safeguard one of their most valuable assets - their samples.

For further information about high volume sample storage tubes and racks please contact Micronic Europe BV now on telephone +31-320-277070 or email sales@micronic.com.

Thursday, 23 February 2012

Just Published: Journal of Chromatography A



A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Packed Column Supercritical Fluid Chromatography (pcSFC) of Hydrophilic Analytes via Water-Rich Modifiers

22 February 2012, 21:55:48Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 22 February 2012
Larry T. Taylor
The use of additives to dramatically extend the range of solute polarity amenable to CO2based supercritical fluid chromatography (pcSFC) was predicted over twenty years ago. At that time additives were predicted to have multiple functions such as enhancement of mobile phase solvating power, ion suppression, and ion pairing. The adsorption of mobile phase components on the stationary phase causing a modification of its surface was predicted, but the implications for separations were not defined. Reports published in the late 1980‘s showed that while water could not function as a primary modifier due to it poor solubility in carbon dioxide, its use as an additive was more promising. The past decade has seen very little published work concerning water and pcSFC. Now reports are beginning to appear that demonstrate enhanced selectivity with water, and application of the technology to polypeptide salts, drug molecules, and nucleobases. This review attempts to bridge the past with the present. As evidenced by the studies described in this review, water may offer much potential as an additive in that it could (a) enhance the solvating power of the mobile phase, (b) introduce HILIC-like analyte partitioning, (c) simplify preparative purifications, and (d) offer a more mass spectrometrically compatible interface.

Highlights

► Water as a neutral additive has been shown to enhance pcSFC selectivity. ► Water enhances solvation of polar analytes and the stationary phase. ► After 20 years, water is finding new applications in pcSFC.

Determination of Tropane Alkaloids Atropine and Scopolamine by Liquid Chromatography-Mass Spectrometry in Plant Organs of Datura Species

22 February 2012, 21:55:48Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 22 February 2012
Silvia Jakabová, Lajos Vincze, Ágnes Farkas, Ferenc Kilár, Borbála Boros, ...
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in theDaturagenus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a potential risk of toxicity for humans and animals. Therefore, a reliable method for the determination of tropane alkaloid content is of high importance.The present work aimed at the elaboration of a rapid method for determination of the most abundantDaturaalkaloids by LC-MS technique using a new generation of core-shell particle packed column. Tropane alkaloid content was investigated in various plant organs of fourDaturataxa (D. innoxia, D. metel, D. stramonium, andD. stramoniumvar.tatula), grown under the same conditions, in two developmental stages.We have developed a rapid LC-MS method for the quantitative determination of atropine and scopolamine, which was successfully applied to quantify the alkaloids in different plant organs (leaves, flowers, stems, seeds) of thorn apples after a simple sample preparation step. Elaboration and validation of the method and analysis of plant extracts were done by UFLC-MS technique, employing an Ascentis Express C18 column. Detection was done in positive ionization mode (ESI + ) and the method suitability was evaluated by several validation characteristics. Quantitation limits are 333 and 167 pg mLfor scopolamine and atropine, respectively, and the method shows very good repeatability.The analysis ofDaturaextracts revealed significant differences depending on the species, the organ and the sampling period. Atropine was found to be dominant over scopolamine in three out of the four taxa investigated.D. innoxiashowed the highest concentrations of scopolamine in all organs examined, whereasD. metelaccumulated the lowest scopolamine levels. Hyoscyamine, measured as atropine, was the highest inD. stramoniumvar.tatula, and the lowest inD. innoxia. Samples collected in summer had higher scopolamine levels than autumn samples, concerning both stems and leaves.

Highlights

► We have developed a rapid LC-MS method for the quantitative determination of atropine and scopolamine. ► The method was successfully applied to quantify the alkaloids in different plant organs (leaves, flowers, stems, seeds) of thorn apples after a simple sample preparation step. ► Lower limits of quantitation are 333 and 167 pg mL-1 for scopolamine and atropine, respectively, and the method shows very good repeatability. ► The analysis ofDaturaextracts revealed significant differences depending on the species, the organ and the sampling period.

Determination of triazine herbicides in cereals using dynamic microwave-assisted extraction with solidification of floating organic drop followed by high-performance liquid chromatography

22 February 2012, 21:55:48Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 21 February 2012
Hui Wang, Guijie Li, Yiqun Zhang, Haiyan Chen, Qi Zhao, ...
A simple and cost-effective method of dynamic microwave-assisted extraction (DMAE) combined with solidification of floating organic drop (SFO) was developed for determining the five triazine herbicides in cereals. The approach combines the advantages of DMAE and SFO technique, and up to 15 samples can be treated simultaneously in 16 min. Firstly, triazine herbicides were extracted with 1 mL of methanol containing 90 μL of 1-dodecanol and following with 10 mL of water under the action of microwave energy. After that, 1.5 g sodium chloride was added into the obtained extract, and the mixture was centrifuged and cooled. The 1-dodecanol drop which contained the target analytes was solidified and transferred for analysis by HPLC-UV. Limits of detection of the five triazines obtained were in the range of 1.1-1.5 ng g. Relative standard deviations of intra- and inter-day tests ranging from 5% to 7% were obtained. The method was successfully applied to the analysis of ten cereals and the recoveries of the triazines for the spiked samples were in the range of 80-102%. The proposed method is an alternative approach to the analysis of triazine herbicides in complex solid samples, being more rapid and simpler compared with the traditional extraction method.

Highlights

► Cereal samples were extracted by dynamic microwave-assisted extraction technology. ► Triazine herbicides in the extract were enriched by 90 μL of 1–dodecanol. ► Extraction and enrichment were completed in a single step. ► The solidified 1–dodecanol contained triazines was analyzed by HPLC–UV. ► Up to 15 samples can be treated simultaneously in 16 min.

Liquid chromatography-flame ionisation detection using a nebuliser/spray chamber interface. Part 2. Comparison of functional group responses

22 February 2012, 21:55:48Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 21 February 2012
Erepamowei Young, Roger M. Smith, Barry L. Sharp, Joanne R. Bone
The application of a LC-nebuliser/spray chamber interface-flame ionization detection has been demonstrated for the superheated water liquid chromatography of a wide range of aliphatic and aromatic analytes. The linearity and sensitivity of the response of volatile and involatile analytes have been compared. The response of the detector towards different analytes is similar to that in GC-FID and for volatile analytes was comparable to UV detection. However, the responses from involatile analytes, such as amino-acids and carbohydrates, was poor and often lower than for a refractive index detector.

Highlights

► A LC-nebuliser/spray chamber interface-flame ionization detection for superheated water liquid chromatography ► responds to a wide range of aliphatic and aromatic analytes ► linearity and sensitivity of the response of volatile and involatile analytes compared ► response of detector compared to GC-FID ► compared to UV and RI detectors

Erratum to “Processing nanoparticles with A4F-SAXS for toxicological studies: Iron oxide in cell-based assays” [J. Chromatogr. A 1218 (2011) 4160–4166]

22 February 2012, 21:55:48Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 21 February 2012
Patrick Knappe, Linda Boehmert, Ralf Bienert, Silvana Kamutzki, Birgit Niemann, ...

Predictions of comprehensive two-dimensional gas chromatography separations from isothermal data

20 February 2012, 22:49:46Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 18 February 2012
Shukui Zhu, Sheng He, David R. Worton, Allen H. Goldstein
Two-dimensional retention times and peak widths in temperature programmed comprehensive two-dimensional gas chromatography were predicted using a theoretical model developed from experimental data obtained under isothermal conditions. A Matlab program was written to calculate the following parameters: dead time (tM), elution temperature (Te), retention time (tR), hold-up width (wM) and peak width (wR). The two-dimensional retention times of a sample mixture that contained n-alkanes and polyaromatic hydrocarbons (PAHs) were predicted and were observed to be in excellent agreement with experimentally determined values. The relative deviation between the model and the experimental data was less than 2 and 7% for the primary and secondary retention times, respectively. The relative deviation of peak width was less than 7 and 10% in the primary and secondary dimensions, respectively. The advantage of this model was its simplicity, informed entirely from experimental data, with no reliance on theoretical parameters. This prediction model would be useful for optimizing GC × GC separation conditions and for confirming compound identifications of components that are chromatographically resolved but that have nearly identical mass spectra.