World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Tuesday, 6 March 2012

Upgrade any Microscope with an LCD View Screen and Digital Camera

Carltex, Inc. of Nyack, NY has introduced a new line of Microscope LCD Digital Tablet/Cameras which are ideal for any microscope that is used in Education, Industry, Medical and R&D applications.
Available in 2.0 MP (BLC-200) and 5.0 MP (BLC-500) resolutions, these units combine the features of a tablet PC and a digital camera. Besides providing a real-time specimen visual display, they can also take specimen snapshots and videos, perform measurements and calibrations (BLC-500), and transfer information to a network and/or internet using the built-in Wi-Fi capability.
Images and data collected are viewed on a 7” (BLC-200) or 10" (BLC-500) high resolution LCD touch screen and can be stored on the built-in Hard Drive or uploaded to a network for further image analysis.
These tablet/cameras are easily connected to any trinocular microscope with a C-mount connector and other included adapters. The BLC-200 can even be connected to mono or binocular microscopes using the included eyepiece adapter.
For complete specification on this new line of HD LCD Digital Tablet/Cameras, go to http://www.carltex.com/BestScope.htm
Carltex Inc. is located in Nyack , N Y , USA with sales, service, and support facilities. Carltex supplies a wide variety of data acquisition, measurement & control products.
For additional information, please contact:
Carltex IncPO Box 770
Nyack, NY 10960 USA
Tel: 845-535-3406
Fax: 845-535-3407
Email: info@carltex.com
Visit our Website at http://www.carltex.com/

Monday, 5 March 2012

Just Published: Talanta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Talanta
Selected papers from the latest issue:

Multiresidue analysis of aromatic organochlorines in soil by gas chromatography-mass spectrometry and QuEChERS extraction based on water/dichloromethane partitioning. Comparison with Accelerated Solvent Extraction

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 3 March 2012
Florent Rouvière, Audrey Buleté, Cécile Cren-Olivé, Carine Arnaudguilhem
A novel multiresidue method was developed for the simultaneous analysis of 34 organochlorines, including chlorobenzenes, chlorophenols, chlorinated hydrocarbons and chlorinated olefins, in soil by GC-MS, using a QuEChERS-based extraction. The conventional QuEChERS method was optimised and, for the first time, the use of a non miscible-water solvent was required. The method was compared to ASE extraction, versatile technique widely used for the soils’ extraction and QuEChERS-based method was shown to be the most efficient in terms of recoveries, simplicity and rapidity. For ASE, recoveries between 42 and 85% were obtained for the majority of the compounds. However, due to the high pressure, all volatile compounds were lost. In opposite, QuEChERS extraction allowed detection and quantification of all the compounds with recoveries between 60 and 100%. Moreover, no additional clean up by dispersive SPE on PSA was necessary, which allowed reducing the cost of the analysis.Performance of the method was assessed. The method was linear over the range of concentration of 10-5000 μg Kg. Precision, expressed as intra-day precision and inter-day variation was verified at three concentrations. Limits of detection were from 2 to 50 μg Kgand limits of quantification from 7 to 170 μg Kgfor the majority of the compounds (chlorobenzenes and chlorinated hydrocarbons and olefins), except for chlorophenols. The method was further applied to different soils coming from a contaminated industrial site, where a new environmental remediation process, using phytoremediation, was tested. The results showed that the method could be applied to any kind of soils (mineral or organic) and was appropriate to very volatile compounds which were not available with conventional technique.

Highlights

► Optimisation of QuEChERS method for the analysis of organochlorines and phenols ► Compared to ASE, the developed QuEChERS method is rapid and easy to use ► Better recoveries with QuEChERS-based method than ASE ► Contrary to conventional methods, no water elimination. Then, no loss of volatiles ► QuEChERS-based method provides clean extracts with few matrix effects

Enhanced fluorescence sensing of melamine based on thioglycolic acid-capped CdS quantum dots

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Guang-Li Wang, Huan-Jun Jiao, Xiao-Ying Zhu, Yu-Ming Dong, Zai-Jun Li
A sensitive and simple method for the determination of melamine (MA) was developed based on the fluorescence enhancement effect of MA for thioglycolic acid-capped (TGA-capped) CdS quantum dots (QDs). Under optimum conditions, a good linear relationship was obtained from 2.0 × 10to 5.0 × 10 M. The detection limit was 1.0 × 10 M, which was much lower than the safety limit (2.5 ppm in USA and the UK; 1 ppm for infant formula in China). The solution pH, the adding sequence of the buffer solution and MA and surface modifiers of CdS QDs greatly influenced the enhancement extent of MA for CdS QDs. The fluorescence enhancement was attributed to the surface passivation of the surface states of QDs by amine group of MA. The method was applied to detect MA in raw milk with satisfactory results. The proposed method manifested several advantages such as high sensitivity, short analysis time, low cost and ease of operation.

Highlights

► A highly sensitive “turn-on” sensor for melamine (MA) ► MA induced obvious fluorescence enhancement in acidic solutions ► Amine group of MA could passivate the surface effect ► The surface modifiers of CdS influenced the enhancement extent ► MA improved the sensitivity for copper (II) ion detection

A Pt layer/Pt disk electrode configuration to evaluate respiration and alkaline phosphatase activities of mouse embryoid bodies

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Raquel Obregon, Yoshiko Horiguchi, Toshiharu Arai, Shihomi Abe, Yuanshu Zhou, ...
A Pt layer/Pt disk electrode configuration was used as a scanning electrochemical microscopy (SECM) probe. The glass seal part of the insulator was covered with a Pt layer to form an exposed pseudo reference electrode. In a HEPES-based medium at pH 7.5, the half-wave potential (E1/2) for [Fe(CN)6]oxidation and O2reduction measured versus the internal Pt pseudo reference was shifted by about–0.2 V, compared with the E1/2measured versus the external Ag/AgCl reference electrode. The shape and the current of the cyclic voltammograms (CVs) did not change notably over time, indicating that the Pt layer is sufficiently stable to be used as an integrated pseudo reference for voltammetric measurements. To demonstrate the suitability for SECM applications, the Pt/Pt probe configuration was used for measuring the oxygen consumption and the alkaline phosphatase (ALP) activity of a single mouse embryoid body (mEB). Ten individual mEB samples were characterized to monitor the oxygen concentration profile. Oxygen reduction currents were monitored at–0.7 V versus the Pt pseudo reference and compared with those monitored at–0.5 V versus Ag/AgCl. The respiration rate of mEBs becomes greater with increasing cultivation dates. We have plotted the oxygen consumption rate (F(O2)) of each mEB sample, measured versus the Pt layer and versus Ag/AgCl. The linearity of the plot was excellent (coefficient of determination R = 0.90). The slope of the least squares method was 1. In a 1.0 mMp-aminophenylphospate (PAPP) HEPES buffer (pH 9.5) solution, APL activity of mEBs can be characterized, to monitor thep-aminophenol (PAP) oxidation current. ALP catalyzes the hydrolysis of PAPP to PAP. The E1/2for PAP oxidation measured versus the Pt layer was not shifted, compared with the E1/2versus Ag/AgCl. The mEB samples were characterized to monitor the PAP concentration profile. PAP oxidation currents were monitored at +0.3 V versus the Pt layer and compared with those monitored at +0.3 V versus Ag/AgCl. We have plotted the PAP production rate (F(PAP)) of each mEB sample, measured versus the Pt layer and versus Ag/AgCl. In this case, the linearity of the plot became slightly scattered, but it was found to be possible to evaluate ALP activities of mEB samples utilizing the Pt/Pt probe configuration. This type of probe is very useful because it is not necessary to insert a reference electrode into the measuring solution to obtain an electrical connection, and thus electrochemical measurement in a small volume becomes much easier.

Graphical abstract


image

Highlights

► An integrated probe was fabricated, with working/pseudo reference electrode ► We measured oxygen consumption and alkaline phosphatase activity of a single muse embryoid bodiy ► The consumption pattern observed agreed well with the conventional SECM method

Polymer modified glassy carbon electrode for the electrochemical determination of caffeine in coffee

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Meareg Amare, Shimelis Admassie
4-amino-3-hydroxynaphthalene sulfonic acid (AHNSA) was electropolymerized on a glassy carbon electrode. The deposited film showed electrocatalytic activity towards the oxidation of caffeine. The polymer-modified electrode showed high sensitivity, selectivity and stability in the determination of caffeine in coffee. The peak current increased linearly with the concentration of caffeine in the range of 6 × 10–4 × 10 mol L, with a detection limit of 1.37 × 10 mol L(LoD = 3δ/slope). Analysis of caffeine in coffee was affected neither by sample matrices nor by structurally similar compounds. Recoveries ranging between 93.75 ± 2.32 and 100.75 ± 3.32 were achieved from coffee extracts indicating the applicability of the developed method for real sample analyses.

Determination of mercury in fish otoliths by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS)

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Erdal Kenduzler, Mehmet Ates, Zikri Arslan, Melanie McHenry, Paul B. Tchounwou
A method based on cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS) has been developed for determination of inorganic mercury, Hg(II), and total mercury in fish otoliths. Sodium borohydride (NaBH4) was used as the only reducing agent and its concentration was optimized across an acidity gradient to selectively reduce Hg(II) without affecting methylmercury, CH3Hg(I). Inorganic Hg was quantitatively reduced to elemental mercury (Hg) with 1 × 10% (m/v) NaBH4. CH3Hg(I) required a minimum of 0.5% (m/v) NaBH4for complete reduction. Increasing the HCl concentration of solution to 5% (v/v) improved the selectivity toward Hg(II) as it decreased the signals from CH3Hg(I) to baseline levels. Potassium ferricyanide solution was the most effective in eliminating the memory effects of Hg compared with a number of chelating and oxidizing agents, including EDTA, gold chloride, thiourea, cerium ammonium nitrate and 2-mercaptoethylamine chloride. The relative standard deviation (RSD) was less than 5% for 1.0 μg LHg(II) solution. The detection limits were 4.2 and 6.4 ng L(ppt) for Hg(II) and total Hg, respectively. Sample dissolution conditions and recoveries were examined with ultra-pure CaCO3(99.99%) spiked with Hg(II) and CH3HgCl. Methylmercury was stable when dissolution was performed with up to 20% (v/v) HCl at 100 °C. Recoveries from spiked solutions were higher than 95% for both Hg(II) and CH3Hg(I). The method was applied to the determination of Hg(II) and total Hg concentrations in the otoliths of red emperor (CRM 22) and Pacific halibut. Total Hg concentration in the otoliths was 0.038 ± 0.004 μg gfor the red emperor and 0.021 ± 0.003 μg gfor the Pacific halibut. Inorganic Hg accounted for about 25% of total Hg indicating that Hg in the otoliths was predominantly organic mercury (e.g., methylmercury). However, as opposed to the bioaccumulation in tissues, methylmercury levels in otoliths was very low suggesting a different route of uptake, most likely through the deposition of methylmercury available in the water.

Highlights

► Mercury in fish otoliths is determined by cold vapor generation ICP-MS. ► Inorganic and methylmercury are determined selectively using NaBH4as only reductant. ► Potassium ferricyanide ensures effective cleaning of residual Hg from sampling system. ► Mercury in fish otoliths is mostly organic mercury. ► Mercury concentrations in fish otoliths show variations with geochemistry of habitats.

Gold-Silver- Nanoclusters Having CHOLİC ACİD Imprinted Nanoshell

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Aytaç Gültekin, Arzu Ersöz, Adil Denizli, Rıdvan Say
Molecular imprinted polymers (MIPs) as a recognition element for sensors are increasingly of interest and MIP-nanoparticles have started to appear in the literature. In this study, we have proposed a novel thiol ligand-capping method with polymerizable methacryloylamido-cysteine (MAC) attached to gold-silver-nanoclusters reminiscent of a self-assembled monolayer and have reconstructed surface shell by synthetic host polymers based on molecular imprinting method for cholic acid recognition. In this method, methacryloylamidohistidine-Pt(II) [MAH-Pt(II)] has used as a new metal-chelating monomer via metal coordination-chelation interactions and cholic acid. Nanoshell sensors with templates give a cavity that is selective for cholic acid. The cholic acid can simultaneously chelate to Pt(II) metal ion and fit into the shape-selective cavity. Thus, the interaction between Pt(II) ion and free coordination spheres has an effect on the binding ability of the gold-silver-nanoclusters nanosensor. The binding affinity of the cholic acid imprinted nanoparticles have investigated by using the Langmuir and Scatchard methods and determined affinity constant (Kaffinity) has found to be 2.73 × 10 mol Land 2.13 × 10 mol L, respectively. At the last step of this procedure, cholic acid level in blood serum and urine which belong to a healthy people were determined by the prepared gold-silver- nanoclusters.

Highlights

► Molecular imprinting is a technology to create recognition sites in a macromolecular matrix ► MIPs are easy to prepare, stable, inexpensive and capable of molecular recognition ► A nanocluster is an amorphous/semicrystalline nanostructure ► We have combined nanoscale materials with MIP.

Improving methodological aspects of the analysis of five regulated haloacetic acids in water samples by solid-phase extraction, ion-pair liquid chromatography and electrospray tandem mass spectrometry

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
M.C. Prieto-Blanco, M.F. Alpendurada, P. López-Mahía, S. Muniategui-Lorenzo, D. Prada-Rodríguez, ...
Haloacetic acids (HAAs) are organic pollutants originated from the drinking water disinfection process, which ought to be controlled and minimized. In this work a method for monitoring haloacetic acids (HAAs) in water samples is proposed, which can be used in quality control laboratories using the techniques most frequently available. Among its main advantages we may highlight its automated character, including minimal steps of sample preparation, and above all, its improved selectivity and sensitivity in the analysis of real samples. Five haloacetic acids (HAA5) were analysed using solid-phase extraction (SPE) combined with ion-pair liquid chromatography and tandem mass spectrometry. For the optimization of the chromatographic separation, two amines (triethylamine, TEA and dibutylamine, DBA) as ion pair reagents were compared, and a better selectivity and sensitivity was obtained using DBA, especially for monohaloacetic acids. SPE conditions were optimized using different polymeric adsorbents.The electrospray source parameters were studied for maximum precursor ion accumulation, while the collision cell energy of the triple quadrupole mass spectrometer was adjusted for optimum fragmentation. Precursor ions detected were deprotonated, dimeric and decarboxylated ions. The major product ions formed were: ionized halogen atom (chloride and bromide) and decarboxylated ions. After enrichment of the HAAs in Lichrolut EN adsorbent, the limits of detection obtained by LC-MS/MS analysis (between 0.04 and 0.3 ng mL) were comparable to those obtained by GC-MS after derivatization. Linearity with good correlation coefficients was obtained over two orders of magnitude irrespective of the compound. Adequate recoveries were achieved (60%-102%), and the repeatability and intermediate precision were in the range of 2.4-6.6% and 3.8-14.8%, respectively. In order to demonstrate the usefulness of the method for routine HAAs monitoring, different types of water samples were analysed. In swimming pool water samples the ∑HAAs were determined between 76-154 ng mL.

Highlights

► Superior selectivity in HAA determination using ion-pair liquid chromatography ► Improved sensitivity in HAAs analysis using tandem mass spectrometry ► Enhanced extraction efficiency using Lichrolut polymeric solid-phase adsorbent and elution with ion-pair reagent ► Preliminary results of HAAs in drinking water and particularly swimming pool water

Highly Sensitive Assay for Screening of Tankyrase 1

The Tankyrase 1 Activity Assay from AMSBIO are highly sensitive screening kits for the identification of Tankyrase 1 inhibitors in an in vitro system.  These new kits are the latest addition to the comprehensive range of high performance PARP assay kits, enzymes & antibodies available from AMSBIO to assist scientists with their DNA damage research.

Tankyrase 1, also known as PARP5, is a telomere associated poly (ADPribose) polymerase that is recruited to telomeres via its interaction with TRF1 and plays a role in the maintenance of telomere length, sister telomere association, and mitotic spindle organization. Tankyrase 1 has also been shown to destabilize axin, thereby activating Wnt signaling and driving tumor cell proliferation. Given these known activities, Tankyrase 1 has become a prominent cancer drug target.

Available in a choice of two easy-to-use, non-radioactive formats - AMSBIO Tankyrase 1 Activity Assay kits offer sensitivity down to 0.1 mUnits of Tankyrase 1 as well as the convenience and productivity benefits of operating in a 96-well microplate format.

AMSBIO's Tankyrase 1 Colorimetric Activity Assay is ideal for the screening of Tankyrase 1 inhibitors and determining IC50 values. The Tankyrase 1 Colorimetric Activity Assay is an ELISA which semi-quantitatively detects poly (ADP-ribose) (PAR) deposited onto immobilized histone proteins in a 96-well format. An anti-PAR monoclonal antibody, goat anti-mouse IgG-HRP conjugate, and HRP substrate are used to generate a colorimetric signal. Thus, the conversion of blue substrate correlates with Tankyrase 1 activity.

The Tankyrase 1 Chemiluminescent Activity Assay from AMSBIO comes as a highly sensitive chemiluminescent screening kit for the identification of Tankyrase 1 inhibitors in an in vitro system. AMSBIO's Tankyrase 1 Chemiluminescent Activity Assay is ideal for the screening of Tankyrase 1 inhibitors and determining IC50 values. The Tankyrase1 Chemiluminescent Activity Assay is an ELISA which semi-quantitatively detects poly (ADP-ribose) (PAR) deposited onto immobilized histone proteins in a 96-well format. An anti-PAR monoclonal antibody, goat anti-mouse IgG-HRP conjugate, and HRP substrate are used to generate a chemiluminescent signal.  Thus, light output correlates with Tankyrase 1 activity.

A data sheet describing the new Tankyrase Activity Assay kits may be downloaded from
www.amsbio.com/datasheets/4700-096-K.pdf (for Colorimetric Assay) and www.amsbio.com/datasheets/4701-096-K.pdf (for Chemiluminescent Assay). Alternatively for further information please contact AMSBIO on +44-1235-828200 / +1-949-768-8365 or email info@amsbio.com

High Throughput Petri Dish Filling

Media preparation labs can now benefit from the introduction by INTEGRA of a new Turbo mode option which significantly accelerates the filling rates of its MEDIAJET Automated Petri Dish Filling System and results in time-savings of more than 40%. With this option, the MEDIAJET sets new filling rate standards for high throughput Petri dish filling.

Enabling labs to fill up to 1100 Petri dishes / hour or deep dishes with high volumes of media (up to 60ml / dish) the MEDIAJET Turbo mode enhances both productivity and operational flexibility.  Existing MEDIAJET users can also benefit from this new feature simply by updating to firmware version (V02.10) and purchasing the Turbo mode kit.

The excellent reliability and true automation provided by the MEDIAJET Automated Petri Dish Filling System significantly reduces operational downtime and labour costs associated with traditional dish filling systems.  A unique media spread function provides the most efficient use of media through ensuring homogeneous distribution and an even surface.  Careful regulation of the media level in each Petri dish provides up to 30% savings on media use compared to some traditional systems.

To learn more about the MEDIAJET Turbo mode option please visit
www.integra-biosciences.com/mail/2011_12_05_Launch_MJ_Turbo-mode/MEDIAJET_Turbo_mode.WMV or contact INTEGRA on +41-81-286-9530 / info@integra-biosciences.com (Europe / Asia Pacific) or +1-603-578-5800 / contact@viaflo.com (North / South America).

Friday, 2 March 2012

Just Published:Spectrochimica Acta Part B: Atomic Spectroscopy

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Spectrochimica Acta Part B: Atomic Spectroscopy
http://rss.sciencedirect.com/publication/science/5287
Selected papers from the latest issue:

Origins of Polyatomic Ions in Laser Ablation - Inductively Coupled Plasma – Mass Spectrometry: An Examination of Metal Oxide Ions & Effects of Nitrogen and Helium in the Aerosol Gas Flow

25 February 2012, 21:53:31
Publication year: 2012
Source: Spectrochimica Acta Part B: Atomic Spectroscopy, Available online 25 February 2012
Travis M. Witte, R.S. Houk
Differences in the origins of polyatomic ions in wet plasma conditions, as exist in solution inductively coupled plasma-mass spectrometry (ICP-MS), versus dry plasma conditions, found in laser ablation (LA)-ICP-MS, are investigated. Silicate and metal samples are ablated and gas kinetic temperature (Tgas) is measured to establish the origins of metal oxide (MO) ions. MOion abundances observed from both the ablation of silicate samples and metallic samples are found to correspond to formation of the polyatomic ion in the ICP. The same strategy is applied to oxide ratios measured when additional gases (N2and He) are introduced into the aerosol gas flow. N2is found to decrease the MO/Msignal ratio by maximizing atomic sensitivity at lower total gas loads. The addition of He reduces polyatomic ions throughout the plasma. Use of both N2and He produces the lowest MO/Msignal ratio and highest Tgasvalues at the position sampled in the ICP. By gaining a better understanding of the origin of polyatomic ions in LA-ICP-MS and their behavior in mixed gas plasmas, perhaps strategies can be developed to minimize polyatomic interferences in the mass spectrum.

Highlights

► MOions are the most abundant polyatomic ions from the sample in LA-ICP-MS. ► The MO/Msignal ratios correspond to a Tgasvalue of ~ 5500 K. ► This Tgasvalue indicates these MOions are not formed during ion extraction. ► N2and/or He in the aerosol gas reduces the abundance of MOions during LA.

Quantification of the fluorine containing drug 5-fluorouracil in cancer cells by GaF molecular absorption via high-resolution continuum source molecular absorption spectrometry

25 February 2012, 21:53:31
Publication year: 2012
Source: Spectrochimica Acta Part B: Atomic Spectroscopy, Available online 24 February 2012
Magnus Krüger, Mao-Dong Huang, Helmut Becker-Roß, Stefan Florek, Ingo Ott, ...
The development of high-resolution continuum source molecular absorption spectrometry made the quantification of fluorine feasible by measuring the molecular absorption as gallium monofluoride (GaF). Using this new technique, we developed on the example of 5-fluorouracil (5-FU) a graphite furnace method to quantify fluorine in organic molecules. The effect of 5-FU on the generation of the diatomic GaF molecule was investigated. The experimental conditions such as gallium nitrate amount, temperature program, interfering anions (represented as corresponding acids) and calibration for the determination of 5-FU in standard solution and in cellular matrix samples were investigated and optimized. The sample matrix showed no effect on the sensitivity of GaF molecular absorption. A simple calibration curve using an inorganic sodium fluoride solution can conveniently be used for the calibration. The described method is sensitive and the achievable limit of detection is 0.23 ng of 5-FU. In order to establish the concept of “fluorine as a probe in medicinal chemistry” an exemplary application was selected, in which the developed method was successfully demonstrated by performing cellular uptake studies of the 5-FU in human colon carcinoma cells.

Highlights

► Development of HR-CS MAS for quantification of fluorine bound to organic molecules ► Measuring as molecular absorption of gallium monofluoride ► Quantification of organic-bound fluorine in biological material ► The concept of “fluorine as a probe in medicinal chemistry” could be established

New Listeria Monoclonal Antibodies

Listeriosis is a serious infection caused by the bacterium Listeria monocytogenes.
This infection is contracted by eating contaminated food. The infection can lead to miscarriage, stillbirth and meningitis. An outbreak in 2011 involving contaminated cantaloupes lead to 30 deaths.

ViroStat has recently released a new set of monoclonal antibodies to Listeria. Several of these are specific to the p60 protein that is secreted by the organism during growth in culture or in contaminated food.
Thus these antibodies offer potential tools for the rapid detection of this food pathogen.

To download the data sheet for these NEW Antibodies and to obtain pricing, go to the ViroStat website at www.virostat-inc.com or call 207-856-6620
ViroStat, Inc. is a primary manufacturer of infectious disease antigens and antibodies, supplying researchers and manufacturers since 1985. Specialties include high affinity antibodies to Flu A, Flu B, RSV & Strep A for use in rapid lateral flow devices as well as antibodies to food-borne pathogens and toxins. Also, many specificities to HCV, HBV, CMV & EBV for use in anti-viral HTS assays
ViroStat, Inc.
PO Box 8522
Portland, ME 04104 USA
Phone: 207-856-6620
Fax: 207-856-6864
E-mail: info@virostat-inc.com
Web: www.virostat-inc.com

Thursday, 1 March 2012

Just Published: Talanta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Talanta
Selected papers from the latest issue:

Determination of quinolones of veterinary use in bee products by ultra-high performance liquid chromatography–tandem mass spectrometry using a QuEChERS extraction procedure

29 February 2012, 00:44:26Go to full article
Publication year: 2012
Source: Talanta, Available online 28 February 2012
Manuel Lombardo-Agüí, Ana M. García-Campaña, Laura Gámiz-Gracia, Carmen Cruces-Blanco
A reliable and rapid Ultra High Performance Liquid Chromatography tandem Mass Spectrometry (UHPLC-MS/MS) method has been developed for the determination of the eight quinolones of veterinary use regulated by European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, flumequine and oxolinic acid). Chromatographic conditions were optimised in order to increase sample throughput and sensitivity. The antibiotics were detected by electrospray ionization in positive ion mode with multiple reaction monitoring (MRM) and MS/MS conditions were optimized in order to increase selectivity, selecting the corresponding product ions for quantification and identification. The separation was achieved in 3 min, using a Zorbax Eclipse Plus C18 column (50 × 2.1 mm, 1.8 μm), with a mobile phase of 0.02% aqueous formic acid solution and acetonitrile. A dispersive solid phase extraction methodology, often referred to as the “QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) method, was optimized for extraction of the quinolones from honey and also it was evaluated for other bee products such as royal jelly and propolis. The method was validated for each matrix in terms of linearity, trueness, precision, limits of detection (LODs) and quantification (LOQ). LODs ranged between 0.2 and 4.1 μg kgwith precision lower than 12% and satisfactory recoveries in most cases. The method was also applied for studying the occurrence of these antibiotics in several market samples.

Highlights

► Eight quinolones in bee products by UHPLC-MS/MS analysis ► Development of QuEChERS as cheap and efficient method for extraction and clean up ► Validation of the method in three different products (honey, royal jelly and propolis) ► LODs between 0.2 and 4.1 μg kgwith precision lower than 12%•Developed method applied to different types of bee product samples

Potentiometric Determination of Tolterodine in Batch and Flow Injection Analysis

29 February 2012, 00:44:26Go to full article
Publication year: 2012
Source: Talanta, Available online 28 February 2012
Marwa M. Sakr, Rasha M. El Nashar
Two new ion-selective electrodes of the plastic membrane type for the determination of Tolterodine (Tol) were prepared. These electrodes depend on the incorporation of the ion- exchangers of the above mentioned drug with phosphotungestic acid (PTA) or Silicotungestic acid (STA) in a PVC matrix. A comparative study is made between the performance characteristics of electrodes containing ion-exchanger in batch and FIA conditions.The usable concentration range of the electrodes was found to be (1.0 × 10–1.0 × 10and 5.0 × 10–1.0 × 10 M) in batch and FIA conditions, respectively. The electrodes have nearly the same usable concentration, pH range and exhibited high selectivity towards Tol in the presence of many inorganic cations and can be used in biological fluids such as urine and plasma. The dissolution profile of the investigated drug as well as its assay in pure and pharmaceutical preparations was performed, and the results were relatively accurate and precise as indicated by the recovery values and coefficients of variation.

Highlights

► Tolterodine chemical sensor is characterized in batch and FIA conditions. ► LOD was 20.5 μg and 25.7 μg and LOQ of 32.5 μg for Tol-PTA and Tol-STA electrodes. ► The electrodes were used for the assay of dosage forms and biological samples. ► The electrodes were applied for dissolution profile of Detrusitolcapsules.

A dual-electrode flow sensor fabricated using track-etched microporous membranes

29 February 2012, 00:44:26Go to full article
Publication year: 2012
Source: Talanta, Available online 27 February 2012
Hitoshi Mizuguchi, Kanako Shibuya, Azumi Fuse, Tomoko Hamada, Masamitsu Iiyama, ...
A new dual-electrode flow sensor has been fabricated by piling the microporous membrane electrodes which have 7–10 μm thickness. The electrode was prepared by sputtering of platinum onto both sides of the membrane filter which contain a smooth flat surface as well as cylindrical pores with uniform diameters. The electrolysis is performed when the sample solution flows through the membrane electrode, and a generated analyte on the first working electrode is instantaneously transported to the surface of second working electrode which is located at the downstream of the first one. In this case, the sample solution surely flows through the pores of the membrane filters. As the result, highly efficient electrolysis was achieved at each electrode, and the collection efficiency values as high as 100% were obtained in the wide range of flow rate. Good responses to the injections of sample solutions were also confirmed in the FIA system.

Highlights

► The microporous membrane electrode was prepared by sputtering of platinum onto the track-etched membrane filter. ► A new dual-electrode flow sensor has been fabricated by piling these electrodes. ► The electrolysis is performed when the sample solution flows through the membrane electrode. ► In this case, the sample solution surely flows through the pores of the membrane filters. ► Because of the highly efficient electrolysis at each electrode, collection efficiency values as high as 100% were obtained.