Just Published: Sensors & Actuators A: Physical

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Gradient heat flux sensors for high temperature environments

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 176
Andrey V. Mityakov, Sergey Z. Sapozhnikov, Vladimir Y. Mityakov, Andrei A. Snarskii, Maxim I. Zhenirovsky, Juha J. Pyrhönen
The paper studies gradient heat flux sensors (GHFS) based on artificial anisotropic thermoelements. Fundamentals, manufacturing technique and examples of applications in thermal measurement experiments are presented. Comparison of different types of sensors is provided.

Design and characterization of MEMS micromotor supported on low friction liquid bearing

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 177
Mei Lin Chan, Brian Yoxall, Hyunkyu Park, Zhaoyi Kang, Igor Izyumin, Jeffrey Chou, Mischa M. Megens, Ming C. Wu, Bernhard E. Boser, David A. Horsley
This paper examines the performance of rotating microdevices incorporating a liquid bearing to couple a rotating element to a fixed substrate. Liquid bearing technology promises to significantly improve the durability and lifetime of micromechanical motors. Here, the fluid is confined between the rotor and stator using surface patterning of a hydrophobic layer. Magnetic actuation of 10mm diameter silicon rotor is used to characterize the liquid bearing motor at rotation rates up to 1800rpm. Bearings with fluid thickness from 20 to 200μm are characterized. A minimum torque of 0.15μN-m is required to initiate rotation. At rotation rates above 720rpm, the rotor wobble is less than ±1mrad and the bearing exhibits viscous friction with a drag coefficient of 1.2×10−3 μN-m/rpm. The drag performance of the disk-type liquid bearing using H2O as the fluid is approximately 15 times lower than that demonstrated in a micro-ball bearing supported rotor.

An array of microliter-sized microbial fuel cells generating 100μW of power

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 177
Seokheun Choi, Junseok Chae
We report an array of three microliter-sized microbial fuel cells (MFCs) connected in series. The three MFCs were integrated into a sandwich of two glass slides, incorporating two chambers of 50μL volumetric capacity that were separated by a cation exchange membrane (CEM). Each anolyte/catholyte chamber was defined by 500-μm thick PTEE (polytetrafluoroethylene) gaskets. The MFCs contained a Geobacter-enriched mixed bacterial culture and ferricyanide, which were independently driven into anolyte/catholyte chambers, respectively. The MFC array produced 100μW total power (33μW/cm2 or 667μW/cm3) and 1.8V output voltage, which are approximately 10 times and 4.5 times higher, respectively, than the maximum values of previously reported microliter-sized MFCs.

Piezoresistive CMOS sensor for out-of-plane normal stress

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 176
Benjamin Lemke, Rajashree Baskaran, Oliver Paul
A piezoresistive sensor for measuring the temperature compensated sum (σ xx + σ yy )/2− βσ zz of the three mechanical normal stress components, where σ xx + σ yy , σ zz , and β denote the in-plane normal stress sum, the out-of-plane normal stress, and a numerical factor close to 1 is presented. The device is based on CMOS-compatible diffusions and exploits the piezoresistive effect acting on vertical current components. The sensor signal and resulting possibilities to extract mechanical stress components are analyzed. Experimental results illustrate the influence of design parameters and operating conditions on the sensor performance and are compared to a simple analytical sensor model. A second-order cross-sensitivity to in-plane shear stresses is discussed and determined experimentally. The temperature compensation is demonstrated by a force measurement with a deviation between the numerically expected and the experimentally extracted value smaller than 15% over the temperature range from 10°C to 60°C.

Design of patterned leaf spring for sensor-probe with stable reflectivity and high sensitivity

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 176
Yeon-Gwan Lee, Dae-Hyun Kim, Chun-Gon Kim
In sensors, integrated reflection mechanisms of the illuminating light to the reflection material on the proof mass require a strict single degree of motion because the accuracy almost entirely depends on the motion of the proof mass. Therefore, this paper describes the optimum design of a mass–spring structure that features high sensitivity and long linear elastic motion range of the leaf spring without rotation and lateral motion of the proof mass. Accordingly, finite element analyses were conducted to determine an optimal leaf spring pattern and to predict the probe performance. The optimum design of the leaf spring was determined by considering five criteria within the linear elastic region of the eight leaf spring models. Then, two types of leaf springs were manufactured, and the proposed mass–spring system integrated to the prototype was fabricated. The reliability of the FEA results and the performance of the fabricated mass–spring model were verified through the force–displacement curve test, the dynamic test, and the rotation test.

Microfabrication of compliant all-polymer MEMS thermal actuators

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 177
Aaron P. Gerratt, Sarah Bergbreiter
This paper presents a fabrication process for compliant all-polymer MEMS actuators. This process allows high-aspect ratio conductive and non-conductive polymer features to be fabricated together in-plane. With this capability, robust all-polymer thermal actuators have demonstrated displacements as large at 100μm and forces as high as 55μN. The actuators are fabricated with elastomeric materials only, so they are very robust and can undergo large strains in both tension and bending and still operate once released.

Miniature conductive polymer actuators for high pressure generation in lab on chip systems

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 177
M. Hiraoka, P. Fiorini, J. O’Callaghan, I. Yamashita, C. Van Hoof, M. Op de Beeck
We developed a miniaturized ‘syringe type’ pump (8mm diameter, 1mm thickness) which generates a flow rate of 2μL/min at a pressure of 3MPa. It consists of a stack of several conductive polymer (CP) layers intercalated with electrolyte layers. The stack is housed in a polycarbonate case specially conceived for integration in a lab-on-chip device. The dependence of strain on applied bias is investigated and the optimum working condition is determined. The actuator operates at a bias lower than 2V. A maximum strain of 13% is measured in the single CP layer when it expands against atmospheric pressure; this strain is reduced by only a factor of 3 when pressure increases up to 15MPa. The power efficiency of the actuator is also measured; it is in the range 10−3–10−4 and increases when pressure increases. Using a stacked actuator, consisting of 8 single actuators stacked on top of each other, a maximum strain of 5% is measured against atmospheric pressure.

Dynamic wood slice recognition using image blur information

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 176
Chen Guang-Sheng, Zhao Peng
Image motion blur and defocus blur often occur when there is a relative motion between the imaging camera and the detected object. In this paper, we propose a robust wood slice recognition scheme using the low quality color wood slice images with the above-mentioned image blurs. First, a novel 2-D image measurement machine is devised, to obtain the object images sequentially by using a color camera. Second, the image-moment-based blur invariant features are calculated. Third, wood slice recognition is performed by using the computed Euclidean distance based on the moment invariants. We have experimentally proved that the effective use of image blur information improves the recognition accuracy of camera-captured wood slices. Moreover, the allowed maximum translation speed of the moving gallery is also discussed theoretically and experimentally. This scheme can identify the wood species by means of the slice recognition so as to judge the physical property and economic value of different wood species correctly.

Structural optimization of contact electrodes in microbial fuel cells for current density enhancements

12 March 2012, 09:24:04Go to full article
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 177
Shogo Inoue, Erika A. Parra, Adrienne Higa, Yingqi Jiang, Pengbo Wang, Cullen R. Buie, John D. Coates, Liwei Lin
More than 200% current density enhancement in miniaturized microbial fuel cells (MFCs) has been successfully demonstrated by optimizing the contact electrode structure using micro and nano features. Two fundamental issues are addressed in this work: (1) a methodology to enhance current/power density of MFCs by changing micro and nano structural configurations of contact electrodes and (2) a study on the effectiveness of charge transfer between living cells with organic nanowire-pili and micro/nano interfacial electrodes. This paper details the fabrication and characterization processes of miniaturized MFCs with experimental results, and discusses the prospective power density of MFCs using micro/nano processes. Moreover, a hypothesis for the direct electron transport mechanism from living cells to electrodes is experimentally corroborated. As such, this work represents a step toward higher energy conversion efficiency as well as practical applications of MFCs.

Yeast lytic enzyme mixture offers superior activity

AMSBIO is the global supplier of Zymolyase, a lytic enzyme mix for the digestion of yeast and fungal cell walls offering superior and broad based biological activity across many genera of fungi.

In
independent tests**, compared to Lyticase and Glusulase, Zymolyase generated yeast protoplasts more efficiently while not hindering regeneration into viable cells. Delivering higher activity compared to other lytic enzymes, Zymolyase offers greater performance at a lower cost for applications including protoplast / spheroplast preparation, yeast cell fusion, transformation of yeast cells and yeast genetics.

Zymolyase®, purified from culture fluid of Arthrobacter luteus, has strong lytic activity against living yeast cell walls to produce protoplast or spheroplast of various strains of yeast cells. The essential enzyme lytic activity of Zymolyase® is beta-1, 3-glucan laminaripentaohydrolase, which hydrolyzes glucose polymers linked by beta-1, 3-bonds and produces laminaripentaose. Zymolyase® is reported to be a complex enzyme including Zymolyase A, beta-1, 3-glucan laminaripentaohydrolase and Zymolyase B, alkaline protease, which may change the structure of the yeast cell wall to facilitate penetration of Zymolyase A.

AMSBIO offers two preparations of Zymolyase: Zymolyase-20T and -100T (lytic activity of 20,000 units / gram and 100,000 units / gram respectively) which are available from local inventory for fast delivery.

For further information please visit http://www.blogger.com/www.amsbio.com/zymolyase.aspx or contact AMSBIO on +44-1235-828200 / +1-949-768-8365 or email info@amsbio.com

Bruker’s Commitment to Chinese Market Shared with Chinese Media at recent CIFSQ Conference in Beijing

Bruker Chemical & Applied Markets division (CAM), US: During the recent China International Food Safety and Quality (CIFSQ) 2011 conference in Beijing, media were engaged in a briefing at the Bruker facilities. Bruker’s continued and rapid growth in China is reflected in the expansion programs for Beijing’s Application Laboratories and Customer Service Centers. Earlier in 2011 the Shanghai Application Laboratory facilities were formerly opened, with a 50% expansion program underway at the Beijing facility plus an additional service and sales office planned for Guangzhou.
“The upgraded facilities and investment opens additional services to the expanding Chinese customer base. With over $100 million in annual revenue, China is of strategic importance to Bruker”, explained Hank Wang, General Manager of Bruker China. “With industry-leading technical expertise, training and customer support now being available to the Chinese market we look forward to greater collaboration opportunities with our Chinese academic, government, clinical and industrial customers” added Wang.
Commenting on Bruker’s growth and investment in China, Rohan Thakur, General Manager of the Bruker CAM division commented on “the excellent collaboration between Bruker China and its customers in the food safety and environmental markets. Thakur added “we view the input from the Chinese market as being vital to our overall R&D efforts”.
Bruker’s CAM division were a sponsor at the CIFSQ event, where they shared their perspectives on food safety and quality assurance. Company experts also presented timely new data on pesticide residues in pumpkin extract and the application of this data in food safety analysis generated on the SCIONTM Gas Chromatography Mass Spectrometry Triple Quadrupole (GC-MS TQ) system. 
For more information on SCION SQ and SCION TQ systems, please visit: http://eu.vocuspr.com/Url.aspx?1151446x15718x976

Friday, 9 March 2012

Just Published: Spectrochimica Acta Part B: Atomic Spectroscopy

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Spectrochimica Acta Part B: Atomic Spectroscopy
http://rss.sciencedirect.com/publication/science/5287
Selected papers from the latest issue:

Metal Argide (MAr+) Ions are lost during ion extraction in laser ablation-inductively coupled plasma-mass spectrometry

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Travis M. Witte, R.S. Houk
The abundance of metal argide (MAr+) ions during laser ablation- inductively coupled plasma-mass spectrometry (LA-ICP-MS) is measured during ablation of pure samples of transition metals. As expected, the relative abundance of MAr+ ions to M+ ions for various elements increases as the dissociation energy (D0) of the ion increases. Gas kinetic temperatures (Tgas) are determined from the calculated MAr+/M+ ratios and are used to indicate the origins of MAr+ ions. The determined Tgas values are very high, 8000K to ≥20,000K, which indicate that MAr+ ions are much less abundant in the mass spectrum than expected based upon plasma conditions. Collision-induced dissociation (CID) during the ion extraction process is suggested to be responsible for removal of MAr+ ions. Factors responsible for these collisions are discussed.

A compact and low cost laser induced breakdown spectroscopic system: Application for simultaneous determination of chromium and nickel in steel using multivariate calibration

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Fabiano Barbieri Gonzaga, Celio Pasquini
This work describes a compact and low cost analyzer for laser induced breakdown spectroscopy (LIBS) based on a diode pumped passively Q-switched Nd:LSB microchip laser and a conventional Czerny-Turner spectrograph (spectral range from about 250 to 390nm) containing a non-intensified, non-gated and non-cooled 1024 pixel linear sensor array. The new LIBS instrument was applied for analyzing steel samples containing chromium and nickel in the concentration range from about 5 to 26% w/w (certified reference materials), integrating the emitted radiation for 40s under continuous application of laser pulses at 2kHz for each acquired spectrum (integration of about 80,000 plasmas). The emission data from about 356 to 362nm and 340 to 354nm were employed for the construction of two Partial Least Squares (PLS) calibration models for determination of chromium and nickel, respectively. The average relative errors of prediction of chromium and nickel concentrations were 3.7 and 6.7%, respectively, which are similar to or lower than those obtained using higher cost LIBS analyzers. The results have shown that multivariate calibration can help to overcome the decreasing instrumental performance associated with the low cost equipment.

Application of the wavelength dispersive X-ray fluorescence technique to determine soil fluorine with consideration of iron content in the matrix

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Jinsung An, Ki-Hyun Kim, Hye-On Yoon, Jungju Seo
The suitability of the wavelength dispersive X-ray fluorescence (WD-XRF) technique for the quantitative analysis of fluorine in soil was assessed in this study. Fluorine standards for WD-XRF calibration with soil matrices consisting of SiO2, Al2O3, Fe2O3, and CaO were prepared by varying the concentrations of CaF2 as a source of fluorine. Based on the standard calibration, the limits of detection and quantification were calculated as 812 and 2690mg-F/kg-solid (or 1.62 and 5.39mg-F in absolute mass term), respectively. In addition, the fluorine intensities of the standard samples with high iron content increased significantly compared to those with low iron content. Because of proximity between F-Kα line and Fe-Lα line, the higher iron content preferably helped increase background fluorine intensities. As a means to compensate for the iron interference effect in fluorine analysis, the correction factor (CF) (0.0045) was derived based on the slope ratios between the measured X-ray intensity at the Bragg angle of 43.174° and iron content in the standard sample. The soil fluorine concentration determined by WD-XRF after the CF adjustment exhibited a significantly high correlation with that of the classical alkali fusion-ISE analysis. These findings clearly demonstrated that the WD-XRF technique is reliable enough to allow an easy, precise, and rapid quantitative determination of fluorine in a solid sample (such as iron-bound soil) compared to conventional methods.

Origins of Polyatomic Ions in Laser Ablation - Inductively Coupled Plasma – Mass Spectrometry: An Examination of Metal Oxide Ions & Effects of Nitrogen and Helium in the Aerosol Gas Flow

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Travis M. Witte, R.S. Houk
Differences in the origins of polyatomic ions in wet plasma conditions, as exist in solution inductively coupled plasma-mass spectrometry (ICP-MS), versus dry plasma conditions, found in laser ablation (LA)-ICP-MS, are investigated. Silicate and metal samples are ablated and gas kinetic temperature (Tgas) is measured to establish the origins of metal oxide (MO+) ions. MO+ ion abundances observed from both the ablation of silicate samples and metallic samples are found to correspond to formation of the polyatomic ion in the ICP. The same strategy is applied to oxide ratios measured when additional gases (N2 and He) are introduced into the aerosol gas flow. N2 is found to decrease the MO+/M+ signal ratio by maximizing atomic sensitivity at lower total gas loads. The addition of He reduces polyatomic ions throughout the plasma. Use of both N2 and He produces the lowest MO+/M+ signal ratio and highest Tgas values at the position sampled in the ICP. By gaining a better understanding of the origin of polyatomic ions in LA-ICP-MS and their behavior in mixed gas plasmas, perhaps strategies can be developed to minimize polyatomic interferences in the mass spectrum.

Quantification of the fluorine containing drug 5-fluorouracil in cancer cells by GaF molecular absorption via high-resolution continuum source molecular absorption spectrometry

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Magnus Krüger, Mao-Dong Huang, Helmut Becker-Roß, Stefan Florek, Ingo Ott, Ronald Gust
The development of high-resolution continuum source molecular absorption spectrometry made the quantification of fluorine feasible by measuring the molecular absorption as gallium monofluoride (GaF). Using this new technique, we developed on the example of 5-fluorouracil (5-FU) a graphite furnace method to quantify fluorine in organic molecules. The effect of 5-FU on the generation of the diatomic GaF molecule was investigated. The experimental conditions such as gallium nitrate amount, temperature program, interfering anions (represented as corresponding acids) and calibration for the determination of 5-FU in standard solution and in cellular matrix samples were investigated and optimized. The sample matrix showed no effect on the sensitivity of GaF molecular absorption. A simple calibration curve using an inorganic sodium fluoride solution can conveniently be used for the calibration. The described method is sensitive and the achievable limit of detection is 0.23ng of 5-FU. In order to establish the concept of “fluorine as a probe in medicinal chemistry” an exemplary application was selected, in which the developed method was successfully demonstrated by performing cellular uptake studies of the 5-FU in human colon carcinoma cells.

Experimental characterization of the effect of skimmer cone design on shock formation and ion transmission efficiency in the vacuum interface of an inductively coupled plasma mass spectrometer

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Nicholas Taylor, Paul B. Farnsworth
Laser-induced fluorescence has been used to evaluate five commercially available skimmer cone designs from inductively coupled plasma mass spectrometers in terms of shock formation at the skimmer tip and transmission efficiency. Efficiency was measured as the ratio of analyte density downstream from the skimmer tip to analyte density upstream from the skimmer tip. The strongest shock was recorded for a skimmer with a cylindrical throat, and the weakest shock was produced by the skimmer with the largest diameter and a conical throat. Transmission efficiency increased with increasing orifice diameter. Coulombic effects, revealed in a comparison between the behaviors of neutral barium atoms and barium ions, were small. Transmission efficiencies recorded for calcium ions were lower than those recorded for barium ions by more than a factor of two.

Mechanisms of chemical generation of volatile hydrides for trace element determination (IUPAC Technical Report) [©2011 IUPAC]

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Alessandro D'Ulivo

A simplified calculation of power-broadened linewidths, with application to resonance ionization mass spectrometry

09 March 2012, 11:53:49Go to full article
Publication year: 2012
Source:Spectrochimica Acta Part B: Atomic Spectroscopy
Jonathan Levine
I present a simple derivation of the power-broadened linewidth of an optical transition in a two-level atom. The novelty of the approach lies in its flexibility, as the approach described here can be applied to any spectral lineshape, corresponding to either homogeneous or inhomogeneous broadening mechanisms. For a Lorentzian profile, I recover the same dependence of linewidth on laser power that one calculates from the optical Bloch equations. The present treatment makes explicit that power broadening arises because of the saturability of the atomic response to intense lasers, rather than to explicitly quantum mechanical aspects of the laser–atom interaction, all of which are ignored. I discuss the utility of power broadening in resonance ionization mass spectrometry, where it is an important means of mitigating unwanted instrumental isotope fractionation.

Diffusion Tubes for Trace Concentration Standards of Solids and Viscous Liquids

Diffusion Tubes have been used for many years as an inexpensive, do-it-yourself way to dynamically blend trace concentration gas mixtures for a large number of common solvents. Typical diffusion tubes have a glass reservoir attached to the end of a precision bore capillary tube.  Solvent liquid is injected into the reservoir through the capillary bore. Solvent emission is controlled by diffusive flow through the capillary and adjusted by choice of capillary bore, length and operating temperature.

KIN-TEK’s Trace Source™ Configurable Diffusion Tubes extend the range of compounds that can be used to include subliming solids and viscous liquids.  These tubes have a removable reservoir that allows filling with the capillary removed, so the component compound can be any consistency.  Additionally, a variety of pre-configured and tested capillaries can be interchangeably fitted to the reservoir adjust the range of concentrations obtainable.

Multiple tubes can be used simultaneously in the FlexStream™ Automated Gas Standards Generating System to create multi-component gas mixtures.

For more information, contact:   
KIN-TEK Laboratories, Inc.,  Phone:  (409) 938-3627
www.kin-tek.com        email:  sales@kin-tek.com

Fluidigm & AH diagnostics Sign Scandinavian Distribution Deal

Fluidigm Corporation has appointed AH diagnostics as its exclusive distributor in Scandinavia (Sweden, Norway, Finland, Denmark, Iceland), effective February 1, 2012. AH diagnostics will offer Fluidigm's complete portfolio of BioMark™ HD, EP1™, and Access Array™ Systems, the complete line up of Dynamic Array™, Digital Array™ and Access Array IFCs for real-time PCR, digital PCR, single-cell gene expression, sample preparation for next-generation sequencing, and SNP genotyping; plus Fluidigm's new DELTAgene™ and SNPtype™ assays.

AH diagnostics was established to supply products and services to life science and diagnostic companies in the pharmaceutical, biotech, hospital and academic research fields. The company has operations in Denmark, Sweden, Norway and Finland. AH diagnostics has built its reputation across Scandinavia as a distribution leader in the life science field, representing leading global manufacturers, such as Fluidigm, providing next-generation tools, technologies, training, applications support, instrument installation, validation, and maintenance support to life science researchers.

"Our goal is to be the supplier of choice for high quality and innovative products, equipment and related support services in Scandinavia within the biotechnology/life science area in selected segments," said Niels Rüdiger, Chief Executive Officer, AH diagnostics. "We are excited to add Fluidigm's innovative microfluidic products that provide unique solutions for many of the critical research challenges facing our scientists."

"Fluidigm is committed to continuing to bring the accuracy and efficiency benefits of integrated fluidic circuit technology to life science researchers in Scandinavia," said Dominique Remy-Renou, Vice President of European Commercial Operations,  Fluidigm Europe BV. "AH diagnostics has built a strong reputation across Scandinavia for addressing the needs of the life science research community. We look forward to helping them bring the tools needed to solve some of today's most complex genetic questions in biology all the way down to the single cell."

AH diagnostics celebrated its 25th anniversary in 2011. The company was established in 1986 in Denmark as a supplier of products and services to life science, diagnostics, pharmaceutical, biotech, hospital and academic researchers.  AH diagnostics has since expanded into the Nordic countries - AH diagnostics (Sweden) was founded the 1st March 1994, AH diagnostics (Norway) began trading on 1st December 1995 and AH diagnostics (Finland) began trading on 1st September 2004. Their head office is located in Aarhus, Denmark. In addition AH diagnostics has a sales office in Copenhagen. The sales and support teams in the four Nordic countries consist mainly of molecular biologists. For more information, please visit http://www.ahdiag.com/.

Fluidigm (NASDAQ: FLDM) develops, manufactures and markets microfluidic systems for growth markets in the life science and agricultural biotechnology, or Ag-Bio, industries. Fluidigm's proprietary microfluidic systems consist of instruments and consumables, including integrated fluidic circuits, or chips, and reagents. These systems are designed to significantly simplify experimental workflow, increase throughput and reduce costs, while providing the excellent data quality demanded by customers. Fluidigm actively markets three microfluidic systems including nine different commercial chips to leading pharmaceutical and biotechnology companies, academic institutions and Ag-Bio companies. For more information, please visit www.fluidigm.com
 

Thursday, 8 March 2012

Just Published: Chemometrics and Intelligent Laboratory Systems

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Chemometrics and Intelligent Laboratory Systems
http://rss.sciencedirect.com/publication/science/5232
Selected papers from the latest issue:

Identification of primary tumors of brain metastases by Raman Imaging and Support Vector Machines

25 February 2012, 22:07:23Go to full article
Publication year: 2012
Source: Chemometrics and Intelligent Laboratory Systems, Available online 24 February 2012
Norbert Bergner, Thomas Bocklitz, Bernd F.M. Romeike, Rupert Reichart, Rolf Kalff, ...
Vibrational spectroscopic imaging techniques are new tools for visualizing chemical components in tissue without staining. The spectroscopic signature can be used as a molecular fingerprint of pathological tissues. Fourier transform infrared imaging which is more common than Raman imaging so far has already been applied to identify the primary tumor of brain metastases. The current study introduces a two level discrimination model for Raman microspectroscopic images to distinguish normal brain, necrosis and tumor tissue, and subsequently to determine the primary tumor. 22 specimens of normal brain tissue and brain metastasis of bladder carcinoma, lung carcinoma, mamma carcinoma, colon carcinoma prostate carcinoma and renal cell carcinoma were snap frozen, and thin tissue sections were prepared. Raman microscopic images were collected with 785 nm laser excitation at 10 μm step size. Cluster analysis, vertex component analysis and principal component analysis were applied for data preprocessing. Then, data of 17 specimens were used to train the discrimination model based on support vector machines with radial basis functions kernel. The training data were discriminated with accuracy better than 99%. Finally, the discrimination model correctly predicted independent specimens. The results were superior to discrimination by partial least squares discriminant analysis and support vector machines with linear basis function kernel that were applied for comparison.

Kernelk-nearest neighbor algorithm as a flexible SAR modeling tool

25 February 2012, 22:07:23Go to full article
Publication year: 2012
Source: Chemometrics and Intelligent Laboratory Systems, Available online 24 February 2012
Dong-Sheng Cao, Jian-Hua Huang, Jun Yan, Liang-Xiao Zhang, Qian-Nan Hu, ...
A kernel version ofk-nearest neighbor algorithm (k-NN) has been developed to model the complex relationship between molecular descriptors and bioactivities of compounds. Kernelk-NN is to perform the originalk-NN algorithm by mapping the training samples in the input space into a high-dimensional feature space. It can be easily constructed by calculating the distance between samples in the feature space, directly deriving from the simple calculation of the kernel used. The developed kernelk-NN is very flexible to deal with complex nonlinear relationship, more importantly; it can also conveniently cope with some non-vectorial data only by the definition of different kernels. The results obtained from several real SAR datasets indicated that the performance of kernelk-NN is comparable to support vector machine methods. It can be regarded as an alternative modeling technique for several chemical problems including the study of structure-activity relationship (SAR). The source codes implementing kernelk-NN in R language are freely available athttp://code.google.com/p/kernelmethods/.

Highlights

► A kernel version of k-NN has been developed. ► The performance of kernel k-NN is competitive to one by SVM. ► Kernel k-NN can cope with non-vectorial data such as string data etc. ► Weighted kernel k-NN was developed to allow the construction of ROC.

Extracting homologous series from mass spectrometry data by projection on predefined vectors

25 February 2012, 22:07:23Go to full article
Publication year: 2012
Source: Chemometrics and Intelligent Laboratory Systems, Available online 23 February 2012
Johan E. Carlson, James R. Gasson, Tanja Barth, Ingvar Eide
Multivariate statistical methods, such as Principal Component Analysis (PCA), have been used extensively over the past decades as tools for extracting significant information from complex data sets. As such they are very powerful and in combination with an understanding of underlying chemical principles, they have enabled researchers to develop useful models. A drawback with the methods is that they do not have the ability to incorporate any physical / chemical model of the system being studied during the statistical analysis. In this paper we present a method that can be used as a complement to traditional chemometric tools in finding patterns in mass spectrometry data. The method uses a pre-defined set of equally spaced sequences that are assumed to be present in the data. Allowing for some uncertainty in the peak locations due to the uncertainties for the measurement instrumentation, the measured spectra are then projected onto this set. It is shown that the resulting scores can be used to identify homologous series in measured mass spectra that differ significantly between different measured samples. As opposed to PCA, the loading vectors, in this case the pre-defined homologous series, are readily interpretable.

Highlights

► A new model-based decomposition of mass spectrometry data into homologous series. ► The method provides fingerprinting and clustering performance similar to that of PCA. ► Underlying loading vectors are immediately interpretable in terms of underlying chemical compounds. ► An application example on a set of bio-oils is provided to demonstrate the principle.