World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Wednesday, 23 May 2012

Successful Oxford Instruments Seminar in Shanghai attracts industry and academia


The recent Nanoscale Plasma Processing Seminar organised by Oxford Instruments in Shanghai attracted over 70 attendees from both academia and production, from China and Taiwan. The company organises these events worldwide several times per year, and has previously co-hosted with prestigious organisations such as the IOS-CAS in Beijing, LBNL, Caltech and Cornell in the USA, Universities of Southampton and Glasgow in the UK, and TU/e in the Netherlands. As a leader in systems and processes for plasma etch and deposition, the company was honoured that so many invited guest speakers participated, all specialists in their field from China, Taiwan and Europe. Process and Applications experts from Oxford Instruments Plasma Technology gave a number of talks on the company’s technologies and process solutions. 

These events held by Oxford Instruments aim to encourage interest in developments within industrial and research communities using Plasma and Ion Beam Etch and Deposition process techniques. They are an ideal means for participants to learn more about latest techniques and findings in an informal atmosphere where participation and interaction are encouraged. Talks included Atomic Layer Deposition (ALD), Photovoltaics (PV), Deep Silicon Etch and Ion Beam technologies during the full one day programme. Guest speakers included: Prof Erwin Kessels, University of Eindhoven (TU/e), Netherlands; Chu Ann-Kuo, Professor of Department of Photonics, National Sun Yat-sen University, Taiwan; Dr. Zhenghua YE, SITP (Shanghai Institute of Technology Physics); Dr. Juncong SHE, Sun Yat-Sen University, China; and Jerry Wang, Manager of Microsystems Technology Center, ITRI, Taiwan.

Mark Vosloo, Sales, CS and Marketing Director, Oxford Instruments comments, “We were pleased to have attracted such a large and high calibre audience to this Seminar in Shanghai, and are extremely honoured that so many distinguished guest speakers gave their time to speak about their work in Plasma Processing. Our Seminars offer a fantastic opportunity for the wider Plasma Processing community to meet andshare their experiences, and to learn more from leading international experts in their field.”

More Seminars are planned worldwide for 2012.

Tuesday, 22 May 2012

Just Published: Chemometrics and Intelligent Laboratory Systems


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Chemometrics and Intelligent Laboratory Systems
http://rss.sciencedirect.com/publication/science/5232
Selected papers from the latest issue:

Achieving bilinearity in non-bilinear augmented first order kinetic data applying calibration transfer

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Maryam Khoshkam, Frans van den Berg, Mohsen Kompany-Zareh
In this paper a calibration transfer method is used to achieve bilinearity for augmented first order kinetic data. First, the proposed method is investigated using simulated data and next the concept is applied to experimental data. The experimental data consists of spectroscopic monitoring of the first order degradation reaction of carbaryl. This component is used for control of pests in fruits, vegetables, forages, cotton and other crops. It is highly toxic and likely human carcinogen, and is lethal to many non-target beneficial insects. The kinetic experiment is performed at different pH-values and emission wavelengths using an excitation wavelength equal to 275nm. Rate constants of different data matrices at different pH values were calculated based on a hard modeling method. Analysis of simulated and experimental data shows that if there is a deviation from bilinearity, applying the model based methods to augmented datasets leads to inaccurate results. The application of a calibration transfer method as an additional step in the hard modeling procedure improves the results, and accurate estimation of reaction rate constants are obtained. The proposed method was compared to Local Spectra Mode of Analysis (LSMA) which was proposed by Puxty et al. A comparison of the results shows that the proposed method is more efficient than LSMA and leads to less uncertainty in estimated rate constants and less percent error in the relative residuals.

Highlights

► Calibration transfer method is used to achieve bilinearity in augmented first order kinetic data for first time. ► The data were analyzed based on hard modelling methods. ► calibration transfer was used as an extra step inside the procedure. ► It is shown that using calibration transfer in hard modelling methods improve the results. ► A general and simple method is proposed for correction of non-bilinearity in full rank systems.

Again about partial least squares and feature selection

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Piotr Zerzucha, Beata Walczak
Permutation (randomization) tests are often used to establish significance of experimental features in the classification or regression PLS models. Standard approach assumes that permutations are performed for the data objects, so the data correlation structure is preserved. In our study, this approach was compared with the UVE-PLS method and its modification, RUVE-PLS. Results of the intensive simulation study give evidence that permutation of objects is not a proper approach in the case of the PLS models and it should be replaced by permutation performed for individual features, and then the performance of all the compared methods is very similar. Performance of UVE-PLS is never worse than performance of R-PLS and it allows fast computations of the statistics of interest (stability of regression coefficients of the PLS model).

Highlights

► New method for feature selection. ► RUVE-PLS preserves distribution of the experimental variables. ► RUVE-PLS preserves correlation structure of the experimental variables. ► UVE-PLS and its modification, RUVE-PLS, perform equally well.

Assessment of the chemical composition of waters associated with oil production using PARAFAC

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Fabiana Alves de Lima Ribeiro, Francisca Ferreira do Rosário, Maria Carmen Moreira Bezerra, André Luis Mathias Bastos, Vera Lúcia Alves de Melo, Ronei Jesus Poppi
In this work, Parallel Factor Analysis (PARAFAC) was used to assess the composition of produced water in 8 oil wells, using their levels of salinity, calcium, magnesium, strontium, barium and sulphate (mg/L), collected during the years 2004 and 2005. This method allowed the identification of tracers for seawater and formation water, as well as identification of standards related to seasonality. The method indicates that the variables salinity, calcium and strontium are associated with formation water, while magnesium and sulphate are associated with water injection. These variables may be used as tracers to distinguish seawater, used as injection water, and formation water, and can be very useful to evaluate the produced water composition. Seasonality aspects are associated with the variation in the levels of sulphate and magnesium, which tend to increase over time while the levels of barium usually decrease. Chemical patterns related to the original reservoirs of each oil well, called A, B and C, also were observed. Samples collected in reservoir B presented the lowest salinity, calcium, strontium and barium levels and the highest magnesium and sulphate levels, while samples from reservoir A showed intermediate levels for the same variables. Reservoir C samples presented the highest values for salinity, calcium, strontium and barium, and the lowest levels of sulphate.

Highlights

► Petroleum exploitation study. ► Assessment of the chemical patterns in produced water from oil wells. ► Parallel Factor Analysis (PARAFAC). ► Patterns recognition related to original reservoir and seasonality.

Classifying cultivars of rice (Oryza sativa L.) based on corrected canopy reflectance spectra data using the orthogonal projections to latent structures (O-PLS) method

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Wen-Shin Lin, Chwen-Ming Yang, Bo-Jein Kuo
To improve the accuracy in discriminating plant species or genotypes in the field with canopy spectral data, a number of statistical methods incorporating measurement techniques have been developed. This study analyzed canopy reflectance spectra collected at the booting stage by using partial least square regression in combination with discriminant analysis (PLS-DA) to establish a classification model for the discrimination of three mega rice cultivars. To improve the model's capability to interpret and sharpen the separation between cultivars, PLS-DA was combined with orthogonal projection to the latent structure (O-PLS) to derive the OPLS-DA models by removing noise and the Y-orthogonal variation. The ground-based high-resolution reflectance spectra (330–1030nm) were acquired from paddy field experiments during the growing periods, and were recalculated at intervals of 10nm. With the PLS-DA approach, the total accuracy for discriminating three cultivars in the calibration datasets was 90% and was above 80% for individual cultivars. In the validation datasets, a similar capability for cultivar discrimination was obtained for both pooled and individual cultivars. However, the Y-orthogonal variation might be embedded within the PLS-DA model. Using the OPLS-DA approach, the large variation within rice cultivars (the intra variation) was effectively removed to improve the performance of both group separation and model establishment. The overall accuracy reached 100% in the calibration datasets and had superior discrimination than the PLS-DA model in the validation datasets. Therefore, the OPLS-DA method is recommended for establishing a classification model for the cultivar discrimination of rice in the vegetative phase using remotely sensed canopy reflectance spectra.

Highlights

► Classifying rice cultivars based on corrected canopy reflectance spectra data. ► Using PLS to construct a classification model (PLS-DA) for discriminant analysis. ► PLS-DA combined with OPLS (OPLS-DA) to remove the intra variation. ► The OPLS-DA models could improve group separation and model establishment.

Combining bootstrap and uninformative variable elimination: Chemometric identification of metabonomic biomarkers by nonparametric analysis of discriminant partial least squares

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Xiao-Ming Sun, Xiao-Ping Yu, Yun Liu, Lu Xu, Duo-Long Di
Interpretation and mining of complex metabonomic data depend heavily on proper use of chemometric methods. Due to the “small n” paradigm and the absence of sufficient information concerning distribution of data, the classical parametric methods based on known theoretical distributions are sometimes unsuitable or unreliable to treat such data. Therefore, nonparametric methods requiring no or very limited assumptions provide useful alternative tools in many practical applications. In this paper, a new discriminant partial least squares combined with bootstrap and uninformative variable elimination (DPLS–BS–UVE) method is proposed for biomarker discovery in metabonomics. The method was tested on two real chromatographic data sets containing plasma metabolic profilings for S180 and H22 tumor-bearing mice. A robust version of c j was used as the cutoff criterion. The results of biomarker discovery were compared with those obtained using variable importance in the projection (VIP) as well as BS. It is demonstrated that similar results are obtained using the three methods and DPLS–BS–UVE could provide easy interpretation of raw data. When the resampling unit increases to 500, the results were not significantly affected. In conclusion, DPLS–BS–UVE is a reliable alternative method for biomarker discovery, especially when the sample size is small.

Highlights

► DPLS-BS-UVE method was firstly used for biomarker discovery in metabonomics. ► The method is especially effective for the small dataset. ► The results were not significantly affected when the BS unit increases to 500.

A new dissimilarity method integrating multidimensional mutual information and independent component analysis for non-Gaussian dynamic process monitoring

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 115
Mudassir M. Rashid, Jie Yu
Traditional multivariate statistical processes monitoring (MSPM) techniques like principal component analysis (PCA) and partial least squares (PLS) are not well-suited in monitoring non-Gaussian processes because the derivation of T 2 and SPE indices requires the approximate multivariate Gaussian distribution of the process data. In this paper, a novel pattern analysis driven dissimilarity approach is developed by integrating multidimensional mutual information (MMI) with independent component analysis (ICA) in order to quantitatively evaluate the statistical dependency between the independent component subspaces of the normal benchmark and monitored data sets. The new MMI based ICA dissimilarity index is derived from the higher-order statistics so that the non-Gaussian process features can be extracted efficiently. Moreover, the moving-window strategy is used to deal with process dynamics. The multidimensional mutual information based ICA dissimilarity method is applied to the Tennessee Eastman Chemical process. The process monitoring results of the proposed method are demonstrated to be superior to those of the regular PCA, PCA dissimilarity, regular ICA and angle based ICA dissimilarity approaches.

Highlights

► A new dissimilarity method is developed for process monitoring. ► Integrating multidimensional mutual information with independent component analysis. ► Higher-order statistics to handle process non-Gaussianity. ► Better fault detection performance than ICA and angle based dissimilarity methods.

An Iterative Hyperspectral Image Segmentation Method Using a Cross Analysis of Spectral and Spatial Information

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems
N. Gorretta, G. Rabatel, C. Fiorio, C. Lelong, J.M. Roger
The combined use of available spectral and spatial information for object detection, which has been promoted by the advent of high spatial resolution hyperspectral imaging devices, now seems essential for many application domains (characterization of urban areas, agriculture, etc.). The proposed approach called "butterfly" is focusing on this issue and realizes a spectral-spatial cooperation scheme to split images into spectrally homogeneous adjoining regions (segmentation). The main idea of the method is to extract spatial and spectral features simultaneously. For achieving this goal, it establishes some correspondences between the spatial and the spectral concepts, in order to run alternately in the two spaces. Thus, the notion of partition specific to the spatial space is associated with the notion of classes in the spectral space. In parallel, the concept of latent variable own to the spectral space is associated with the notion of image plans in the spatial space. The proposed scheme is therefore to update the features specific to each space (i.e. partition, classes, latent variables and plans) by the knowledge of the features in the complementary space and this recursively. An implementation of this generic scheme using a split and merge strategy is given. Experimental results are presented for a synthetic image and two real hyperspectral images with two different spatial resolution. Results on the set of real images are also compared to those obtained with conventional approaches.

Linking GC-MS and PTR-TOF-MS fingerprints of food samples

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems
Luca Cappellin, Eugenio Aprea, Pablo Granitto, Ron Wehrens, Christos Soukoulis, Roberto Viola, Tilmann D. Märk, Flavia Gasperi, Franco Biasioli
Recently the first applications in food science and technology of the newly available volatile organic compounds (VOCs) detection technique proton transfer reaction - mass spectrometry, coupled with a time of flight mass analyzer (PTR-TOF-MS), have been published. In comparison with standard techniques such as GC-MS, PTR-TOF-MS has the remarkable advantage of being extremely fast but has the drawback that compound identification is more challenging and often not possible without further information. In order to better exploit and understand the analytical information entangled in the PTR-TOF-MS fingerprint and to link it with GC/SPME-MS analyses we employed two multivariate calibration methods, PLS and the more recent LASSO. We show that, while in some cases it is sufficient to consider a single PTR-TOF-MS peak in order to predict the intensity of a GC/SPME-MS peak, in general a multivariate approach is needed. We compare the performances of PLS and LASSO in terms of prediction capabilities and interpretability of the model coefficients and conclude that LASSO is more suitable for this problem. As case study, we compared GC and PTR-MS data for different matrices, namely olive oil and grana cheese.

Highlights

► Two different non-invasive headspace techniques are compared: GC-MS and PTR-ToF-MS. ► Two different food matrices (olive oil and grana cheese) are analyzed. ► LASSO and PLS have been used to compare GC-MS and PTR-ToF-MS fingerprints. ► LASSO and PLS have similar performances but LASSO results are more interpretable. ► It is possible to set reliable prediction models for many compounds.

Comments on Multiple Self Organising Maps (mSOMs) for simultaneous classification and prediction: Illustrated by spoilage in apples using volatile organic profiles by S.F. Sim and V. Sági-Kiss

22 May 2012, 16:05:15
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems
Richard G. Brereton, Virág Sági-Kiss
This paper comments on the article “Multiple Self Organising Maps (mSOMs) for simultaneous classification and prediction: Illustrated by spoilage in apples using volatile organic profiles by S.F. Sim and V. Sági-Kiss, Chemometrics and Intelligent Laboratory Systems 57–64 (2011)”. It describes the origin of most of the methods and software, from the Bristol group, which is unattributed in the original paper. The article comments about conventions for citing software, and authorship of articles, and puts the work into context.

Highlights

► Software developed in Bristol for SOMs is described ► Comments about collaborative authorship of papers and the changing conventions and orientation of chemometrics are discussed. ► Work on supervised SOMs is put into perspective.

New Supercritical Fluid Extractor for the Processing of Natural Products


Supercritical Fluid Technologies (SFT) is pleased to introduce a new pilot scale supercritical extractor for the processing of natural products. The SFT-NPX-10 is designed to simplify the extraction of a wide variety of natural products, and to facilitate the transition from laboratory scale equipment to production processing systems.

The SFT-NPX-10 is designed to perform supercritical fluid extractions in either single or dual 10 Liter sample vessels with single or dual separators, resulting in maximum efficiency. A Coriolis mass flow meter guarantees precise mass flow measurement. A pneumatic CO2 pump with an integral waterless pre-chiller (patent pending) is used to maximize pumping efficiency. Upgrade to an RIO programmable automation controller for automated regulation for pressure, temperature and process cycles.

Using supercritical CO2 to perform extractions on botanicals, herbs, spices and other natural product materials has significant benefits over the use of traditional liquid solvents. While the supercritical fluid possesses many of the same characteristics of a liquid solvent, it adds the benefits of high diffusivity and pressure tunable solvency power. Additionally, no residual solvents are in either the extract or remaining biomass. There is no need to perform a distillation step since, upon dropping pressure, the CO2 becomes a gas. The extracted material is pure and in its natural state. The CO2 may be safely vented or optionally recycled for even greater efficiency. Since the solvency power of the fluid is pressure dependent, it is possible to “fractionate” to obtain multiple compositions from a single raw material. This makes practical some separations that are difficult or impossible to do with traditional liquid solvent and distillation processing.

For more information, please call us at 302-738-3420 or visit us on-line at www.supercriticalfluids.com.

Saturday, 19 May 2012

Just Published: Journal of Chromatography B


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Application of nanoLC–MS/MS to the shotgun proteomic analysis of the nematocyst proteins from jellyfish Stomolophus meleagris

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B
Rongfeng Li, Huahua Yu, Ronge Xing, Song Liu, Yukun Qing, Kecheng Li, Bing Li, Xiangtao Meng, Jinhui Cui, Pengcheng Li
The nematocyst proteins of jellyfish Stomolophus meleagris, a complicated mixture, contain many important bioactive molecules. In present study, to gain comprehensive insight into the protein component and search some novel bioactive molecules in the nematocyst proteins, shotgun proteomic analysis of the nematocyst proteins was carried out by nano liquid chromatography tandem mass spectrometry (nanoLC–MS/MS) for the first time. Digested peptides of the nematocyst proteins were analyzed by nanoLC–MS/MS and all MS/MS spectrums were then automatically searched by the SEQUEST program. A total of 181 proteins had been identified, with the molecular weight ranging from 5268.06 to 843487.57 and the pI from 4.49 to 11.39. Bioinformatic analysis was also applied to better understand the identified proteins. In the Gene Ontology (GO) annotation, all the identified proteins were classified into 13, 9 and 7 groups according to biological process, cellular component and molecular function, respectively. Pathways analysis of the identified proteins was conducted with 33 corresponding pathways found. On the basis of pathways analysis, we also constructed the gene network to analyze the relationship of those genes each other, which contained enzyme-enzyme relation, protein-protein interaction and gene expression interaction.

Highlights

► We analyzed the nematocyst proteins of jellyfish Stomolophus meleagris by using the nanoLC–MS/MS with the shotgun proteomic method. ► A total of 181 proteins had been identified with the molecular weight ranging from 5268.06 to 843487.57 and the pI from 4.49 to 11.39. ► The identified nematocyst proteins were analyzed by bioinformatic method including gene ontology (GO) annotation, pathways and gene network analysis.

Simultaneous quantification of metronidazole, tinidazole, ornidazole and morinidazole in human saliva

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B
Yongqing Wang, Peipei Zhang, Ningling Jiang, Xiaojian Gong, Ling Meng, Dewang Wang, Ning Ou, Haibo Zhang
The aim of this study was to develop a rapid and sensitive method for the simultaneous quantification of metronidazole (MEZ), tinidazole (TNZ), ornidazole (ONZ) and morinidazole (MNZ) in human saliva. A reversed-phase high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection at 318nm was carried out on a C18 column, using a mixture of potassium dihydrogen phosphate buffer, acetonitrile, and methanol (55:15:30, v/v/v) as a mobile phase with a flow rate of 1.0ml/min. The saliva samples (100μl) were firstly deproteinized by precipitation with methanol (400μl), after which they were centrifuged and the supernatants were directly injected into the HPLC system. This method produced linear responses in the concentration ranges of 25.2–5040.0, 23.9–4790.0, 25.4–5080.0, 25.0–5000.0ng/ml with detection limits of 6.0, 17.6, 10.0 and 11.3ng/ml for MEZ, TNZ, ONZ and MNZ (S/N =3), respectively. The methods were validated in terms of intra- and inter-batch precision (within 7.3% and 9.1%, respectively), accuracy, linearity, recovery and stability. The study proved that HPLC is both sensitive and selective for the simultaneous quantification of MEZ, TNZ, ONZ and MNZ in human saliva using a single mobile phase.

Highlights

► Simultaneous quantification of metronidazole, tinidazole, ornidazole and morinidazole. ► Ornidazole and Morinidazole (500mg) reach more than 4100ng/ml after i.v. infusion. ► The method is simple, sensitive and specific, with a short analysis time (6min). ► It was used to find out who had taken other 5-nitroimidazole derivatives before trial.

Development and validation of a hydrophilic interaction liquid chromatography–tandem mass spectrometry method for the quantification of lipid-related extracellular metabolites in Saccharomyces cerevisiae

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
Tao Sun, Stephanie J. Wetzel, Mitchell E. Johnson, Beth A. Surlow, Jana Patton-Vogt
A highly sensitive hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC–MS/MS) method was developed and validated for the quantification of glycerophosphoinositol (GroPIns), glycerophosphocholine (GroPCho), glycerol 3-phosphate (GroP), inositol, and choline in the extracellular medium of Saccharomyces cerevisiae. The media samples were pretreated with a single two-phase liquid extraction. Chromatographic separation was achieved on a Waters Xbridge HILIC (150mm×4.6mm, 5μm) column under isocratic conditions using a mobile phase composed of acetonitrile/water, 70:30 (v/v) with 10mM ammonium acetate (pH adjusted to 4.5) at a flow-rate of 0.5mL/min. Using a triple quadrupole tandem mass spectrometer, samples were detected in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curves were linear (r 2 ≥0.995) over the range of 0.5–150nM, with the lower limit of quantitation validated at 0.5nM for all analytes. The intra- and inter-day precision (calculated by coefficient of variation, CV%) ranged from 1.24 to 5.88% and 2.46 to 9.77%, respectively, and intra- and inter-day accuracy (calculated by relative error, RE%) was between −8.42 to 8.22% and −9.35 to 6.62%, respectively, at all quality control levels. The extracellular metabolites were stable throughout various storage stability studies. The fully validated method was successfully applied to determine the extracellular levels of phospholipid-related metabolites in S. cerevisiae.

Highlights

► A new analytical method to determine extracellular levels of lipid-related metabolites. ► Five metabolites are separated in 20min with lower limit of quantification at 0.5nM. ► The developed method is successfully applied to monitor the extracellular levels of metabolites in S. cerevisiae.

Validation of a liquid chromatography/tandem mass spectrometry method for the simultaneous quantification of Sotrastaurin and its metabolite N-desmethyl-sotrastaurin in human blood

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
Annamaria Jakab, Serge Winter, Bertrand Guy, Marc Raccuglia, Frank Picard, John M. Kovarik, Jayraj Chudasama, Swati Guttikar, Puran Singhal, Olivier Kretz
A liquid chromatography/tandem mass spectrometry (HPLC–MS/MS) method was validated for the quantification of Sotrastaurin (AEB071) and N-desmethyl-sotrastaurin in human blood. The validation of the analytical procedure was performed according to the latest Food and Drug Administration (FDA) “Guidance for Industry, Bioanalytical Method Validation”. Chromatographic separation was performed using an RP C18 (50mm×4.6mm, 5μm) column at 40±3.0°C with a mobile phase consisted of 2mM ammonium acetate in water (pH 4.5):methanol:acetonitrile (25:15:60, v/v) of a flow rate of 1mL/min followed by quantification with tandem mass spectrometer, operated in electrospray ionization (ESI) positive ion mode and applying multiple reaction monitoring (MRM). The validated method described in this paper presents high absolute recovery, with a sensitivity of 3.00ng/mL as lower limit of quantitation using a sample volume of 300μL, low inter-run bias and variability (for Sotrastaurin, −4.4 to 0.4% and 1.8 to 2.5% and for N-desmethyl-sotrastaurin, ranged from 1.6 to 2.3% and 2.7 to 3.9%, respectively) with a short runtime of 3.5min. The method was validated using K3EDTA as specific anticoagulant and cross-validated using Li-Heparin and Na-Heparin. The method was specific for Sotrastaurin and N-desmethyl-sotrastaurin within the given criteria of acceptance (apparent peak area for Sotrastaurin and N-desmethyl-sotrastaurin in zero samples ≤20% of mean peak area at LLOQ) in human blood. The method was fully validated for the quantitative determination of Sotrastaurin and its metabolite N-desmethyl-sotrastaurin in human blood between the range of 3.00ng/mL and 1200ng/mL.

Highlights

► Sotrastaurin, an investigational drug for organ transplantation, autoimmune disorders. ► A method to estimate the drug and its active metabolite in human blood is developed. ► This original method employs LC–MS/MS and was validated. ► The limit of quantification was between 3ng/mL and 1200ng/mL. ► The acceptance criteria (FDA) for method validation were met.

LC–ESI–MS method for the monitoring of Abl 1 tyrosine kinase

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
Hui Chen, Erwin Adams, Ann Van Schepdael
A liquid chromatography–electrospray ionization–mass spectrometric (LC–ESI–MS) method was developed and validated to study Abl 1 tyrosine kinase. An online desalting system was adopted, and a transformation of the ratio of product to substrate instead of a deuterated internal standard was introduced to calculate the concentration of product. In this study, the substrate used was Abltide (KKGEAIYAAPFA-NH2). The detection was performed by selected ion monitoring (SIM) mode via positive ESI interface. Chromatographic separation was achieved on a C18 column using an isocratic mobile phase system. The limit of quantification (LOQ) was 10nM for the product and 25nM for the substrate. The simple ratios of product to substrate maintained a linear relationship (R 2 =0.9997) over the ratio of 0–50% product. Intra- and inter-day precision was less than 10% and accuracy was from −1.6 to +5.3%. The validated method was applied to the Abl 1 kinase kinetic study and the K m and V max constants obtained for Abltide were 34.78μM and 5.563μmol/mg/min and for adenosine triphosphate (ATP) were 43.61μM and 5.906μmol/mg/min. The enzymatic reaction of Abl 1 tyrosine kinase belongs to ternary-complex mechanism.

Highlights

► The kinetic constants of Abl 1 are successfully studied. ► With online desalting system, Tris–HCl buffer is used to conduct enzyme reaction. ► Enzyme reaction of Abl 1 tyrosine kinase belongs to ternary-complex mechanism.

LC–MS/MS method for the quantitation of metabolites of eight commonly-used synthetic cannabinoids in human urine – An Australian perspective

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
Andrew D. de Jager, Janet V. Warner, Michael Henman, Wendy Ferguson, Ashley Hall
An LC–MS/MS method for the quantitation of urinary metabolites of eight JWH-type synthetic cannabinoids (SCs) has been developed and validated. Urine samples are subjected to deconjugation using β-glucuronidase, followed by a solvent extraction procedure. Compounds are separated on a reverse-phase HPLC column within a 14min cycle. Low assay limits are required in order to demonstrate prior exposure to SCs. Matrix effects were studied and proved to be significant for selected analytes, and were challenging to circumvent as isotope-labeled internal standards are not available. An elimination profile from a naïve user following a single smoke of “Kronic” was constructed, showing urinary excretion over 2–3 days with peak concentrations of different metabolites 3–16.5h after smoking. This method has been developed to process several hundred samples within a high-throughput drugs of abuse laboratory, with growing evidence that the use of synthetic cannabinoid blends is common within the Australian workforce.

Highlights

► Good sensitivity, enabling tracking of urinary metabolites for several weeks. ► Herbal blend analysis showed suppliers tailoring composition, as in Europe. ► Application of method to urine samples showed appropriate biomarkers were selected. ► Several hundred samples processed, with positive rate as expected. ► Samples from single individual produced informative time-course profile.

Determination of imidacloprid in rice by molecularly imprinted-matrix solid-phase dispersion with liquid chromatography tandem mass spectrometry

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
Ligang Chen, Bin Li
A new method based on matrix solid-phase dispersion (MSPD) coupled with liquid chromatography tandem mass spectrometry has been developed for the determination of imidacloprid in rice. The molecularly imprinted polymers were synthesized and applied as the dispersant of MSPD for selective extraction of imidacloprid from rice, while interferences originated from sample matrices were eliminated simultaneously. The satisfactory recovery of imidacloprid was obtained by the optimized extraction conditions: 1:2 as the ratio of sample to MIPs; 8min as the dispersion time; 20% aqueous methanol as washing solvent and methanol as elution solvent. Under the optimal conditions, the linearity of imidacloprid in rice sample was achieved in the range of 10–1000ng/g, and limit of detection was 2.4ng/g. The relative standard deviations of intra- and inter-day tests ranging from 4.5% to 5.9% and from 4.8% to 7.1% are obtained, respectively. The proposed method was applied to the determination of imidacloprid in eight rice samples with recoveries in the range of 83.8–92.5%.

Highlights

► MIP-MSPD–LC–MS/MS method was developed. ► The method was used for determination of imidacloprid in rice. ► The recoveries of imidacloprid in rice samples from 83.8% to 92.5% were obtained. ► The proposed method was proved to be sensitive and rapid.

On-fiber furan formation from volatile precursors: A critical example of artefact formation during Solid-Phase Microextraction

19 May 2012, 15:20:35
Publication year: 2012
Source:Journal of Chromatography B, Volume 897
An Adams, Fien Van Lancker, Bruno De Meulenaer, Agnieszka Owczarek-Fendor, Norbert De Kimpe
For the analysis of furan, a possible carcinogen formed during thermal treatment of food, Solid-Phase Microextraction (SPME) is a preferred and validated sampling method. However, when volatile furan precursors are adsorbed on the carboxen/PDMS fiber, additional amounts of furan can be formed on the fiber during thermal desorption, as shown here for 2-butenal and furfural. No significant increase in furan amounts was found upon heating the furan precursor 2-butenal, indicating that the furan amounts formed during precursor heating experiments are negligible as compared to the additional amounts of furan formed during fiber desorption. This artefactual furan formation increased with increasing desorption time, but especially with increasing desorption temperature. Although this effect was most pronounced on the Carboxen/PDMS SPME-fiber, it was also noted on two other SPME-fibers tested (PDMS and DVB/Carboxen/PDMS). The general impact on furan data from food and model systems in literature will depend on the amounts of volatile precursors present, but will probably remain limited. However, considering the importance of this worldwide food contaminant, special care has to be taken during SPME-analysis of furan. Especially when performing precursor studies, static headspace sampling should preferably be applied for furan analysis.

Highlights

► Considerable amounts of furan can be formed on the SPME fiber during thermal desorption of volatile furan precursors. ► The artefactual furan formation increased with increasing desorption time, but especially with increasing desorption temperature. ► The artefactual formation of furan may influence a high amount of literature data and current investigations.

INTEGRA PIPETBOY Brand Celebrates 30th Anniversary


Specialists in laboratory liquid handling tools - INTEGRA has announced a special 3-year warranty to celebrate 30 years of its PIPETBOY serological pipette controller brand.

During the last 30 years, millions of scientists around the world have benefited from the comfortable, safe and effortless way that PIPETBOY pipette controllers have enabled them to reproducibly pipette liquids from 0.1 to 100 ml.

PIPETBOY combines all essential features for productive work: precision, speed, comfort and reliability. The tried and trusted smart valve design and speed regulation on PIPETBOY pipette controllers enable accurate control of dosing from drop-by-drop to fast pipetting using just finger pressure on trigger controls.  Available in a large choice of colours, PIPETBOY pipette controllers offer a simple way of minimising the risk of cross-contamination and enabling individual scientists to personalise their lab equipment thereby avoiding mix-up's.

PIPETBOY pipette controllers are today for used for a vast array of applications including liquid transfer in life sciences labs, fast pipetting for cell culture, gravity dispensing as well as precision dosing using all serological, glass or plastic pipettes in biology, pharmaceutical or microbiology labs.

To learn more about the latest generation of PIPETBOY pipette controllers, all offered with an extended 3-year warranty, and the limited Anniversary Edition of PIPETBOY, please visit www.pipetboy.info or contact INTEGRA on +41-81-286-9540 / info@integra-biosciences.com. 

Tuesday, 15 May 2012

Just Published: Analytica Chimica Acta


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Using a photochemical method and chitosan to prepare surface-enhanced Raman scattering–active silver nanoparticles

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Kuang-Hsuan Yang, Chia-Ming Chang
In this paper, we report a new strategy for the preparation of surface-enhanced Raman scattering (SERS)-active silver nanoparticles (Ag NPs), using a photochemical method and the presence of chitosan (Ch). First, Ag substrates were subjected to electrochemical oxidation/reduction cycles (ORCs) in deoxygenated aqueous solutions containing 0.1M HNO3 and 1gL−1 Ch (pH 6.9, adjusted by adding 1M NaOH), resulting in Ag+–Ch complexes. These substrates were then irradiated with UV light at various wavelengths to yield the SERS-active Ag NPs. A stronger SERS effect was observed on the SERS-active Ag NPs prepared by using UV irradiation at 310nm. The pH of the solution and the presence of Ch during the preparation process both affected the resulting SERS activities.

Graphical Abstract

image

Graphical abstract Highlights

SEM images of Ag NPs obtained after reducing Ag+-containing complexes in solutions of 0.1M HNO3 containing 1gL−1 Ch (pH 6.9, adjusted with 1M NaOH) under irradiation with UV light of wavelength of 310nm for 30min. ► Prepare SERS-active Ag nanoparticles by using green process with aid of chitosan. ► The Ag-containing complex was irradiated with UV light to yield SERS activity. ► pH of the solution and the presence of Ch both affect the resulting SERS activities.

Determination of inorganic phosphate by electroanalytical methods: A review

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Sheela Berchmans, Touma B. Issa, Pritam Singh
Determination of inorganic phosphate is of very high importance in environmental and health care applications. Hence knowledge of suitable analytical techniques available for phosphate sensing for different applications becomes essential. Electrochemical methods for determining inorganic phosphate have several advantages over other common techniques, including detection selectivity, stability and relative environmental insensitivity of electroactive labels. The different electrochemical sensing strategies adopted for the determination of phosphate using selective ionophores are discussed in this review. The various sensing strategies are classified based on the electrochemical detection techniques used viz., potentiometry, voltammetry, amperometry, unconventional electrochemical methods etc., The enzymatic sensing of phosphate coupled with electrochemical detection is also included. Various electroanalytical methods available in the literature are assessed for their merits in terms of selectivity, simplicity, miniaturisation, adaptability and suitability for field measurements.

Graphical Abstract

image

Graphical abstract Highlights

► Advantages of electrochemical sensing of phosphate. ► Classification of electrochemical methods of sensing. ► Ionophores for potentiometric sensing of phosphate. ► Supramolecular based sensing of phosphate: voltammetry and amperometry. ► Unconventional and indirect methods of sensing phosphate.

Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
M.I. Kaniu, K.H. Angeyo, A.K. Mwala, M.J. Mangala
Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace ‘bioavailable’ macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using 109Cd isotope source EDXRF spectrometer for 200s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R 2 >0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98μgg−1 for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors’ knowledge, this is the first time that an XRF method has demonstrated utility in trace analysis of macronutrients in soil or related matrices.

Graphical Abstract

image

Graphical abstract Highlights

► Chemometrics-assisted EDXRFS spectroscopy realizes direct, rapid and accurate analysis of trace bioavailable macronutrients in soils. ► The method is minimally invasive, involves little sample preparation, short analysis times and is relatively insensitive to matrix effects. ► This opens up the ability to rapidly characterize large number of samples/matrices with this method.

Mesoporous TiO2 aerogel for selective enrichment of phosphopeptides in rat liver mitochondria

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Liyuan Zhang, Zhen Liang, Kaiguang Yang, Simin Xia, Qi Wu, Lihua Zhang, Yukui Zhang
The enrichment of low abundance phosphopeptides before MS analysis is a critical step for in-depth phosphoproteome research. In this study, mesoporous titanium dioxide (TiO2) aerogel was prepared by precipitation and supercritical drying. The specific surface area up to 490.7m2 g−1 is achieved by TiO2 aerogel, much higher than those obtained by commercial TiO2 nanoparticles and by the latest reported mesoporous TiO2 spheres. Due to the large specific surface area and the mesoporous structure of the aerogel, the binding capacity for phosphopeptides is six times higher than that of conventional TiO2 microparticles (173 vs 28μmolg−1). Because of the good compatibility of enrichment procedure with MALDI-TOF-MS and the large binding capacity of TiO2 aerogel, a detection limit as low as 30amol for analyzing phosphopeptides in β-casein digest was achieved. TiO2 aerogel was further applied to enrich phosphopeptides from rat liver mitochondria, and 266 unique phosphopeptides with 340 phosphorylation sites, corresponding to 216 phosphoprotein groups, were identified by triplicate nanoRPLC-ESI-MS/MS runs, with false-positive rate less than 1% at the peptide level. These results demonstrate that TiO2 aerogel is a kind of promising material for sample pretreatment in the large-scale phosphoproteome study.

Graphical Abstract

image

Graphical abstract Highlights

► The specific surface area of TiO2 aerogel is 10 times larger than TiO2 nanoparticle. ► The limit of detection for phosphopeptides was down to 30amol by TiO2 aerogel. ► The loading capacity for phosphopeptides was 6-fold larger than TiO2 microparticle.

Selective trace analysis of chloroacetamide herbicides in food samples using dummy molecularly imprinted solid phase extraction based on chemometrics and quantum chemistry

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Lei Zhang, Fang Han, Yanyun Hu, Ping Zheng, Xuan Sheng, Hao Sun, Wei Song, Yaning Lv
A methodology based on chemometrics and quantum chemistry was proposed to design and synthesize dummy molecularly imprinted polymers (DMIPs) capable of extracting chloroacetamide herbicides from food samples. Molecular modeling approach in conjunction with clustering analysis was used to predict the most suitable dummy template. Metolachlor deschloro was selected as the template to synthesize DMIPs, which were used as the solid phase extraction (SPE) materials. The selective adsorption of DMIPs was evaluated by high performance liquid chromatography (HPLC). The retention property of six chloroacetamide herbicides on DMIPs was also predicted using clustering analysis. The optimum loading, washing and eluting conditions for dummy molecularly imprinted solid phase extraction (DMISPE) were established to obtain high selectivity and sensitivity. Water, dichloromethane and methanol were chosen as loading, washing and elution solvent, respectively. Under optimized DMISPE conditions, recoveries of analytes were in the range of 83.4–106.7% with satisfactory precision (RSD% lower than 13%). Compared with other commercial SPE columns, DMISPE exhibited selective binding properties for chloroacetamide herbicides and the matrix effect was significantly decreased.

Graphical Abstract

image

Graphical abstract Highlights

► Hyperchem was used to simulate chloroacetamide herbicides and their metabolites. ► Clustering analysis was conducted to analyze the structural data. ► Metolachlor deschloro was selected as the dummy template to synthesize DMIPs. ► The elution order of herbicides on DMIPs was predicted using clustering analysis. ► Compared with other SPE columns, the matrix effect was decreased using DMISPE.

Measurement of laser activated electron tunneling from semiconductor zinc oxide to adsorbed organic molecules by a matrix assisted laser desorption ionization mass spectrometer

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Hongying Zhong, Jieying Fu, Xiaoli Wang, Shi Zheng
Measurement of light induced heterogeneous electron transfer is important for understanding of fundamental processes involved in chemistry, physics and biology, which is still challenging by current techniques. Laser activated electron tunneling (LAET) from semiconductor metal oxides was observed and characterized by a MALDI (matrix assisted laser desorption ionization) mass spectrometer in this work. Nanoparticles of ZnO were placed on a MALDI sample plate. Free fatty acids and derivatives were used as models of organic compounds and directly deposited on the surface of ZnO nanoparticles. Irradiation of UV laser (λ =355nm) with energy more than the band gap of ZnO produces ions that can be detected in negative mode. When TiO2 nanoparticles with similar band gap but much lower electron mobility were used, these ions were not observed unless the voltage on the sample plate was increased. The experimental results indicate that laser induced electron tunneling is dependent on the electron mobility and the strength of the electric field. Capture of low energy electrons by charge-deficient atoms of adsorbed organic molecules causes unpaired electron-directed cleavages of chemical bonds in a nonergodic pathway. In positive detection mode, electron tunneling cannot be observed due to the reverse moving direction of electrons. It should be able to expect that laser desorption ionization mass spectrometry is a new technique capable of probing the dynamics of electron tunneling. LAET offers advantages as a new ionization dissociation method for mass spectrometry.

Graphical Abstract

image

Graphical abstract Highlights

► Irradiation of photons with energies more than the band gap generates electron–hole pairs. ► Electron tunneling probability is dependent on the electron mobility. ► Tunneling electrons are captured by charge deficient atoms. ► Unpaired electrons induce cleavages of chemical bonds.

Small molecule analysis using laser desorption/ionization mass spectrometry on nano-coated silicon with self-assembled monolayers

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Ömür Çelikbıçak, Gökhan Demirel, Erhan Pişkin, Bekir Salih
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is an emerging technique for the determination of the molecular weight of biomolecules and their non-covalent complexes without fragmentation. One problem with this technique is the use of excess amounts of matrices, which may produce intense fragment ions and/or clusters at low mass ranges between 1 and 800Da. These fragments lead to interference, especially concerning the signals of small target molecules. Here, a simple, reusable, and quite inexpensive approach was demonstrated to improve the effectiveness of laser desorption/ionization mass spectrometry (LDI-MS) analysis, especially for small molecules, without using matrix molecules. In this study, substrates with controllable morphologies and thicknesses were developed based on the self-assembly of silane molecules on silicon surfaces using N-(3-trimethoxysilylpropyl)diethylenetriamine (TPDA) and octadecyltrichlorosilane (OTS) molecules. Prepared substrates with nano-overlayers were successfully used in the analysis of different types of small target molecules, namely acrivastine, l-histidine, l-valine, l-phenylalanine, l-arginine, l-methionine and angiotensin I. Our substrates exhibited clear peaks almost without fragmentation for all target molecules, suggesting that these surfaces provide a number of important advantages for LDI-MS analysis, such as ease of preparation, costs, reusability, robustness, easy handling and preventing fragmentation.

Graphical Abstract

image

Graphical abstract Highlights

► A new substrate using controllable nano-structured silicon surfaces based on the self-assembly of silane molecules (OTS and TPDA) was proposed. ► A matrix-free approach for use in laser desorption/ionization mass spectrometry (LDI-MS) for the analysis of small target molecules was demonstrated. ► The modified surfaces with nano-overlayers should be seriously considered to improve LDI-MS analysis. ► The detection of small molecules by eliminating the need for matrix provides a number of important advantages.

Dual lifetime referenced fluorometry for the determination of doxorubicin in urine

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Fernando Martínez Ferreras, Otto S. Wolfbeis, Hans H. Gorris
Dual lifetime referencing (DLR) is introduced as a rapid and self-referenced method for measuring the concentration of a fluorescent analyte in solution. The fluorescent cancer chemotherapeutic doxorubicin was chosen as a medically relevant analyte and blended with a reference dye (Ru(dpp)3) that displays overlapping excitation and emission spectra. The relative contributions of the short-lived (nanoseconds) fluorescent analyte and the long-lived (microseconds) reference dye define the observed lifetime. Measuring this lifetime by both frequency-domain DLR and time-domain DLR yields similar analytical ranges and limits of detection (0.4μM). To assess the matrix effect of medical samples, the standard addition method was employed to both modes of DLR. Urine was spiked with doxorubicin and recovery rates of ≥97% were obtained.

Graphical Abstract

image

Graphical abstract Highlights

► Self-referenced determination of fluorescent analytes in solution by dual lifetime referencing. ► Comparison of frequency-domain DLR and time-domain DLR. ► DLR has a detection limit of 400nM doxorubicin.

Sequence-specific detection of nucleic acids utilizing isothermal enrichment of G-quadruplex DNAzymes

15 May 2012, 17:58:58
Publication year: 2012
Source:Analytica Chimica Acta, Volume 729
Hao-Jie Xiao, Ho Chol Hak, De-Ming Kong, Han-Xi Shen
G-quadruplex DNAzymes are peroxidase-like complexes formed by nucleic acid G-quadruplexes and hemin. Various chemical sensors and biosensors have been developed, based on such DNAzymes. Here we report a novel, specific nucleic acid detection method utilizing the isothermal amplification strategy of G-quadruplex DNAzymes. In this method, an unlabeled oligonucleotide probe was used. The probing sequence of the oligonucleotide was in the form of a stem-loop structure. A G-rich sequence, containing three GGG repeats, was linked to the 5′-end of the stem-loop structure. In the presence of target, the probing sequence hybridized to the target, and a G n (n ≥2) repeat was extended from its 3′-end. This G n repeat, together with the three GGG repeats at the 5′-end, folded into a G-quadruplex, and displayed enhanced peroxidase acitivity upon hemin binding. Utilizing the dynamic binding interaction between the probe and its target, the enrichment of G-quadruplex DNAzymes was achieved. Using this method, simple, rapid and cost-effective nucleic acid detection could be achieved. This method displayed high target-length tolerance and good detection specificity; one-base mismatch could be judged easily, even by visual inspection. This method may be used as an auxiliary tool for amplified detection of specific DNA targets in some situations, in which isothermal detection is desirable.

Graphical Abstract

image

Graphical abstract Highlights

A novel, specific nucleic acid detection method was reported based on an isothermal amplification strategy of G-quadruplex DNAzymes. Using this method, simple, rapid and cost-effective nucleic acid detection could be achieved. This method displayed high target length tolerance and good detection specificity, one-base mismatch could be easily judged, even by visually. This method may be used as an auxiliary tool for amplified detection of specific DNA targets in some situations, in which isothermal detection is desirable. ► A novel, specific nucleic acid detection method was designed. ► This method utilized a target-mediated isothermal amplification of G-quadruplex DNAzymes. ► This method provides a new way for single-nucleotide polymorphism detection. ► This nucleic acid detection method displayed high target length tolerance. ► This method needs no labeled oligonucleotides, and only simple colorimetric detection was required.

Peripheral Blood Mononuclear Cells for Biomarker Research


AMSBIO has introduced the ImmunoPure™ range of peripheral blood mononuclear cells (PBMCs) supplied in proprietary reagents that ensure high survival and recovery rates.

ImmunoPure™ PBMCs are a variety of immune cells derived from the peripheral blood of normal healthy human adult donors collected at IRB-approved blood banks.  Seven types are currently available and consist of a variety of immune cells derived from the peripheral blood of normal adults, thereby qualifying them for a diverse number of cell-based experiments. The lymphocyte and monocyte fractions are isolated from whole blood using apheresis, a technology in which the blood of a donor is passed through an apparatus that separates out these fractions, and returns the remainder to the donor's circulation. After depletion of granulocytes, and red blood cell these PBMCs are immediately cryopreserved using proprietary reagents to ensure high cell viability. All cell batches of ImmunoPure™ PBMCs are rigorously tested to be free from infectious agents and analysed for cell viability, cell purity, cell count, and CD markers.

ImmunoPure™ PBMCs the latest addition to a comprehensive collection of primary cells supplied by AMSBIO that represent a diverse and heterogeneous population of donors.  As well as a variety of normal human primary cells offered with optimized media, AMSBIO offer viable primary tumour cells from a huge number of cancer types.

For further information on ImmunoPure™ peripheral blood mononuclear cells (PBMCs) please visit
www.amsbio.com/ImmunoPure.aspx?dm_i=SGX,R4NC,49PFY8,26WN6,1 or contact AMSBIO on +44-1235-828200 or email info@amsbio.com.