This blog has been set up for editors, reviewers, authors and readers of Elsevier's Analytical Chemistry Journals - all of which can be seen below. It will be updated from Monday to Friday with general news and announcements concerning the titles listed on this page. It should be noted that the views or claims made in the news items and feeds are not necessarily those of the Publisher.
Available from Uniqsis Ltd. the FlowSyn Polar Bear™ is a state-of-the-art
chiller unit which, in combination with FlowSyn Continuous Flow Reactor, allows
you to perform and control reactions down to -88°C.
The FlowSyn Polar Bear™ provides faster and more efficient cooling than
conventional chiller units and is ideal for pre-cooling reagents and
controlling temperature in highly exothermic reactions. The system is
compatible with the FlowSyn range of reactor modules and is designed to prevent
ice formation so that you can clearly observe reactions as they occur.
Traditionally equipment for cooling flow chemistry reactions below -70°C has
been cumbersome and inconvenient, involving pressurised gas cylinders and/or
heat exchangers. With its fully integrated plug-and-play design, the Polar
Bear™ is both easy to install and simple to operate, as well as providing
superb cooling performance. The Polar Bear™ uses advanced cooling technology
without the need for solid CO2, solvents or heat transfer fluids to deliver
rapid cooling down to -88°C at the simple touch of a button.
The Polar Bear™ module is
compatible with all Uniqsis coil reactors and mixer blocks and works in
combination with and can be controlled by any FlowSyn flow reactor system. For
highly exothermic reactions the Polar Bear Plus module is additionally compatible with Uniqsis’ proprietary mixer /
reactor chip technology.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
In this study, an efficient strategy based on bioassay-guided
fractionation, high-performance liquid chromatography/electrospray ionization
quadrupole time-of-flight mass spectrometry (HPLC-ESI-Q/TOF-MS) and high-speed
counter-current chromatography (HSCCC) was established to screen and purify
bioactive compounds from Chinese herbal medicines (CHMs). This screening system
was efficient and successfully applied to reveal anti-prostate cancer candidates
from Puerariae thomsonii Flos. As a result, an active fraction with strong in
vitro anti-prostate cancer activity was obtained, and the main compounds in the
fraction were purified by HSCCC, giving 82mg of tectoridin, 36mg of
tectorigenin-7-O-[β-d-xylopyranosyl-(1→6)-β-d-glucopyranoside and 64mg of
tectorigenin. Among them, tectorigenin, possessing the highest anti-prostate
cancer activity with IC50 value of 0.08μM, has priority to be lead compound. The
results of this work demonstrated that the developed method was efficient and
could be employed for the rapid screening, identification and purification of
active components from CHMs.
Graphical abstract
Highlights
► An efficient strategy
based on bioassay-guided fractionation, HPLC-ESI-Q/TOF-MS and HSCCC was
established to screen and purify bioactive compounds from CHMs. ► The screening
system succeeded in discovering anti-prostate cancer candidates from Puerariae
thomsonii Flos. ► Tectoridin,
tectorigenin-7-O-[β-d-xylopyranosyl-(1→6)-β-d-glucopyranoside and tectorigenin
were prepared from Puerariae thomsonii Flos by HSCCC for the first time. ►
Tectorigenin possessed potent inhibition effect on growth of RM-1 prostate
cancer cells with IC50 value of 0.08μM.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
Dimethyl sulfate (DMS) is frequently used in pharmaceutical
manufacturing processes as an alkylating agent. Trace levels of DMS in drug
substances should be carefully monitored since the compound can become an
impurity which is genotoxic in nature. Derivatization of DMS with dibenzazepine
leads to formation of the N-methyl derivative, which can be retained on a
reversed phase column and subsequently separated from other potential
impurities. Such derivatization occurs relatively slowly. However, it can be
substantially speed up if ionic liquids are used as reaction media. In this
paper we report the use of 1-butyl-1-methylpyrrolidinium
bis(trifluoromethylsulfonyl)imide (IL1) and 1-butyl-4-methylpyridinium
tetrafluoroborate (IL2) as reaction media for the derivatization of DMS with
dibenzazepine. It was determined that the stoichiometry between the substrate
and DMS may be 1:1 or 2:1, in relation with the nature of the reaction media. An
(+)ESI-MS/MS approach was used for quantitation of the derivatized product.
Alternatively, DMS derivatization may be carried out with pyridine in
acetonitrile (ACN). The N-methylpyridinium derivative was separated by
hydrophilic interaction liquid chromatography (HILIC) and detected through
(+)ESI-MS (in the SIM mode). In both cases, a limit of quantitation (LOQ) of
0.05μg/ml DMS was achievable, with a linearity range up to 10μg/ml. Both
analytical alternatives were applied to assay DMS in 4-(2-methoxyethyl)phenol,
which is used as a starting material in the synthesis of metoprolol.
Graphical abstract
Highlights
► LC/MS–MS analysis at
sub-ppm level of dimethyl sulfate in starting materials for APIs is proposed. ►
Derivatization of DMS with dibenzazepine or pyridine was achieved. ►
Derivatization kinetics was studied in acetonitrile and ionic liquids
(pseudo-first-order). ► Derivatization with dibenzazepine in ionic liquids is
much faster than in acetonitrile. ► RPLC (for N-methyl-dibenzazepine) and HILIC
(for N-methyl-pyridine) separation modes were used.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
This paper presents the development of a new method for the simple and
reliable quantification of the free drug amount in liposomal preparations of
prednisolone phosphate (PP). In this method the free drug is distinguished from
the encapsulated drug by means of hydrolysis of the free PP into prednisolone
(P) by alkaline phosphatase (AP). During method development reaction progress
curves were recorded to determine the required AP concentration and the
corresponding incubation time to achieve hydrolysis of all free PP. Reaction
progress curves also showed that small changes in the amount of weighted AP and
the incubation periods used do not cause a change in outcome. Further, several
organic solvents were tested as precipitation solvent and the use of
tetrahydrofuran (THF) yielded clean chromatograms, rapid AP deactivation and
complete liposome rupture avoiding under- and overestimations of the
encapsulated and free drug concentrations. Method accuracy was evaluated during
a cross-validation involving dialysis. Intra- and interday precision were
evaluated by determining the standard deviation (SD) and relative standard
deviation (RSD) after applying the new method on one day (n =4) and on different
days (n =3). The accuracy of the developed method is comparable to the accuracy
determined by dialysis, while clearly the method using AP is more precise. In
conclusion, comprehensive method development yielded an accurate and precise
method, which can replace traditional methods like dialysis and solid phase
extraction (SPE). With little effort the method can be upgraded and become part
of the liposome certification prior to human use. The overall principle behind
the method offers possibilities for many drug carrier systems.
Highlights
► A method for the quantification of the free drug
amount in liposomal preparations of prednisolone phosphate was developed. ► The
free drug is distinguished from the encapsulated drug by means of enzymatic
hydrolysis. ► In this way difficulties accompanying traditional separation
techniques were circumvented. ► Thismethod is reliable, accessible,
inexpensive,fast and suitable for small sample volumes and a large number of
samples. ► The principle behind this method offers also possibilities for the
free drug determination of many drug carrier systems.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
Nine polysaccharide-based chiral stationary phases (CSPs) were used to
define a separation strategy that combines normal-phase (NP), reversed-phase
(RP) and polar organic solvent chromatography (POSC) modes. After limiting
ourselves to two CSPs per mode, in total, five CSPs, Chiralpak AD (NP),
Chiralcel OD (RP and POSC), Lux Cellulose-1 (NP), Lux Cellulose-2 (POSC) and Lux
Cellulose-3 (RP), showed the broadest enantioselectivity and most
complementarity. Six sequences of the three modes were considered to decide
which sequence is the most successful for screening a set of 56 pharmaceutical
compounds. Starting the strategy with the NP mode, followed by RP and finally
POSC was found preferable from both the number of cumulative separations and of
baseline separations. Two approaches were considered for strategy fine tuning
using an additional set of eight racemic mixtures. In both approaches, seven of
the eight compounds were baseline resolved, on one of the examined columns at
either screening or optimization conditions of a mode. One approach was finally
preferred because of its lower workload.
Highlights
► 56 compounds and nine CSPs were used to update
strategies in three common HPLC modes. ► An HPLC chiral method development
strategy that combines NPLC, RPLC and POSC modes was defined. ► Success rate:
all compounds were separated with the updated strategy in less experiments. ►
The updated strategy was fine tuned.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
A microflow chemiluminescence (CL) sensor for determination of dibutyl
phthalate (DBP) based on magnetic molecularly imprinted polymer (MMIP) as
recognition element was fabricated. Briefly, a hydrophilic molecularly imprinted
polymer layer was produced at the surface of Fe3O4@SiO2 magnetic nanoparticles
(MNPs) via combination of molecular imprinting and reversible stimuli responsive
hydrogel. In this protocol, the initial step involved co-precipitation of
Fe2+ and Fe3+ in an ammonia solution. Silica was then
coated on the Fe3O4 nanoparticles using a sol–gel method to obtain silica shell
magnetic nanoparticles. The MMIP was synthesized using methacrylic acid (MAA) as
functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker
and 2, 2-azobisisobutyronitrile (AIBN) as initiator in chloroform. Then the
synthesized MMIP and magnetic non-molecular imprinted polymers (MNIP) were
employed as recognition by packing into lab-made straight shape tubes, connected
in CL analyzer for establishing the novel sensor with a single channel syringe
pump. And a mixer for hydrolyzing of DBP was followed. Based on this experiment
principle, DBP was determined indirectly. And the MMIP showed satisfactory
recognition capacity to DBP, resulting to the wide linear range of
3.84×10−8 to 2.08×10−5 M and the low detection limit of
2.09×10−9 M (3σ) for DBP. The relative standard deviation (RSD) for
DBP (3.20×10−6 M) was 1.40% (n =11). Besides improving sensitivity
and selectivity, the sensor was reusable. The proposed DBP–MMIP–CL sensor has
been successfully applied to determine DBP in drink samples.
Graphical abstract
Highlights
► Fe3O4@SiO2 was used as
support for easier to control. ► Microscale Syringe Pump was used for saving
reagent. ► A mixer for hydrolyzing was used for
chemiluminescence.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
In this work, a dispersive liquid–liquid microextraction (DLLME)
procedure combined with ultra-high performance liquid chromatography with
diode-array detection was developed to determine 25 antibiotics in mineral and
run-off waters. Optimum DLLME conditions (5mL of water at pH=7.6, 20% (w/v)
NaCl, 685μL of CHCl3 as extractant solvent, and 1250μL of ACN as disperser
solvent) allowed the repeatable, accurate and selective determination of 11
sulfonamides (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole,
sulfadimidin, sulfamethoxypyridazine, sulfadoxine, sulfamethoxazole,
sulfisoxazole, sulfadimethoxine and sulfaquinoxaline) and 14 quinolones
(pipemidic acid, marbofloxacin, fleroxacin, levofloxacin, pefloxacin,
ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin,
difloxacin, moxifloxacin, oxolinic acid and flumequine). The method was
validated by means of the obtention of calibration curves of the whole method as
well as a recovery study at two levels of concentration. The LODs of the method
were in the range 0.35–10.5μg/L with recoveries between 78% and 117%.
Graphical abstract
Highlights
► A DLLME–UHPLC-DAD
method was developed to determine antibiotics in water. ► A total of 25
compounds (11 sulfonamides and 14 quinolones) was analyzed. ► Relative
recoveries values of the method were between 74% and 117%. ► The procedure is
simple, fast and reliable to determine the selected antibiotics.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
Oral squamous cell carcinoma (OSCC) is an aggressive cancer and its
occurrence is closely related to betel nut chewing in Taiwan. However, there are
few prognostic and diagnostic biomarkers for this disease especially for its
association with betel nut chewing. Recent progresses in quantitative proteomics
have offered opportunities to discover plasma proteins as biomarkers for
tracking the progression and for understanding the molecular mechanisms of OSCC.
In present study, plasma samples from OSCC patients with at least 5-year history
of betel nut chewing and healthy donors were analyzed by fluorescence
2D-DIGE-based proteomic analysis. Totally, 38 proteins have been firmly
identified representing 13 unique gene products. These proteins mainly function
in inflammatory responses (such as fibrinogen gamma chain) and transport
(Apolipoprotein A–I). Additionally, the current quantitative proteomic approach
has identified numerous OSCC biomarkers including fibrinogen (alpha/beta/gamma)
chain, haptoglobin, leucine-rich alpha-2-glycoprotein and ribosomal protein S6
kinase alpha-3 (RSK2) which have not been reported and may be associated with
the progression and development of the disease. In summary, this study reports a
comprehensive patient-based proteomic approach for the identification of
potential plasma biomarkers in OSCC. The potential of utilizing these markers
for screening and treating OSCC warrants further investigations.
Graphical abstract
Highlights
► Oral squamous cell
carcinoma (OSCC) is an aggressive cancer closely related to betel nut chewing. ►
Quantitative proteomics have offered opportunities to discover plasma OSCC
protein biomarkers. ► This study identified numerous unreported OSCC markers
such as RSK2. ► The utilization of these markers for screening and treating OSCC
warrants further investigations.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
Psoralea corylifolia L. (Fabaceae) is a traditional Chinese medicine
with many beneficial effects in medical therapies. Bakuchiol was the main active
ingredient of Psoralea corylifolia L. In this study, a novel method of
pre-column derivatization with dansyl chloride followed by analysis of ultra
high-performance liquid chromatographic–tandem mass spectrometry (UHPLC–MS/MS)
was established and validated for quantification of bakuchiol in rat plasma. The
linearity of this approach was confirmed to be within the concentration range of
0.5–1000ng/mL and the lower limit of quantification was at 0.5ng/mL. The total
analysis time was 1.5min for each pretreated sample. Also, the precision,
accuracy, stability, recovery and matrix effect of this method were proved to
meet the requirements for bioanalysis. The intravenous and oral pharmacokinetic
profiles of bakuchiol were obtained by utilizing this approach. The oral
bioavailability of bakuchiol in rats (3.2%) was identified.
Graphical abstract
Highlights
A novel method of pre-column derivatization with
dansyl chloride followed by analysis of ultra high-performance liquid
chromatographic–tandem mass spectrometry (UHPLC–MS/MS) was established and
validated for quantification of bakuchiol in rat plasma. The intravenous and
oral pharmacokinetic profiles of bakuchiol were obtained by utilizing the
established method. ► An UHPLC–MS/MS method with
pre-column derivatization was built for bakuchiol. ► The method demonstrated
high sensitivity, wide linear range and short runtime. ► The method was used to
explore the pharmacokinetic profile of bakuchiol in rats. ► The oral
bioavailability of bakuchiol (3.2%) was reported for the first
time.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
Over the last two decades, a growing number of scientific evidences
highlighted the potential therapeutic value of several structures of
aminoglycoside antibiotics (including gentamicin and G418) for the treatment of
various genetic diseases caused by nonsense mutations. These findings resulted
in a fast evolvement of synthetic derivatives of aminoglycosides which were
shown to be more target specific and less toxic than the clinically used
antibiotics. The emerging progress in drug design and development has
necessitated the urge to develop a fast, easy and accurate procedure for the
determination of these potential therapeutic agents in various biologically
derived matrices. Here we describe the preparation of a generic polyclonal
antibody that was used for the development of homologous and heterologous
immunoassays for the detection of a wide range of natural and synthetic
aminoglycoside derivatives, highlighted today as potential therapeutic agents
for the treatment of various genetic diseases. A common two-ring scaffold, NB82,
present in the majority of compounds exhibiting potent biological activity, was
used as a generic immunization hapten for the immunization of two rabbits. By
using a series of chemical steps, NB82 was selectively conjugated via the N-1
position through glutaric acid linker to a carrier protein. Sensitivity (I 50)
values for the recognition of three representative compounds NB82, NB84 and
NB124 were determined to be 10±3ngmL−1, 0.5±0.04μgmL−1 and
1±0.12μgmL−1, respectively. Limits of detection were determined to be
1±0.3ngmL−1 for NB82, 20±7ngmL−1 for NB84 and
15±8ngmL−1 for NB124. The developed assays were further exploited for
the in vivo monitoring of the therapeutic compounds in mice serum. Serum
experimentations exhibited similar detection limits as observed for the PBS
calibration experiments, demonstrating no interference with assays sensitivity,
with rather high recovery ratios ranging from 92 to 107% in whole blood samples.
Graphical abstract
Highlights
► A broad-specific ELISA
for the detection of aminoglycosides with 6′-OH was developed. ► These 6′-OH
aminoglycosides are best candidates for the treatment of genetic diseases. ► A
two-ring scaffold was selectively conjugated to a carrier protein at N-1
position. ► A generic antibody allowed highly sensitive monitoring of
therapeutic agents in vivo. ► The assay will aid in further development of
therapeutic compounds in clinic.
5 March 2013 Publication year:
2013 Source:Journal of Pharmaceutical and Biomedical Analysis, Volume
75
The metabolites and pharmacokinetics of ganoderic acid C2 (GAC2), a
bioactive triterpenoid in Ganoderma lucidum in rat plasma were investigated by
high-performance liquid chromatography coupled with electrospray ionization
tandem mass spectrometry (HPLC–ESI-MS/MS). Totally, ten minor phase I
metabolites of GAC2 were characterized after oral administration of GAC2, on the
basis of their mass fragmentation pathways or direct comparison with authentic
compounds by high-performance liquid chromatography coupled with diode array
detection and electrospray ion trap tandem mass spectrometry
(HPLC–DAD–ESI-MS n ), and liquid chromatography coupled with
electrospray ionization hybrid ion trap and time-of-flight mass spectrometry
(LC–ESI-IT-TOF/MS) methods. Moreover, a rapid and specific method for
quantification of GAC2 in rat plasma after oral administration was developed by
using a liquid–liquid extraction procedure and HPLC–ESI-MS/MS analysis. It is
the first time to report the metabolites and pharmacokinetics of GAC2.
Graphical abstract
Highlights
Proposed metabolic pathways of ganoderic acid C2
(M0) in rats. ► Ten minor phase I metabolites were
characterized. ► A rapid quantification method was developed by LC–MS/MS. ► The
metabolites and pharmacokinetic of GAC2 were reported firstly.
Offering
24 high volume (3.1ml) wells in an industry standard 96-well plate footprint,
the Krystal 24 from Porvair Science provides a large surface area
per well, enabling unmatched cell growth.
Constructed in ultra-pure grade polystyrene, Porvair Krystal 24 microplates are
tissue culture treated to ensure optimal cell growth and attachment. The
special design of Krystal 24 plates makes them ideal for cell culture, cloning,
viral titration, and cell fusion. Precisely manufactured to ANSI / SLAS
microplate dimensions* the affordable tissue culture treated Krystal 24
microplate is fully compatible with all commercially available plate readers,
robotic sample processors and automated liquid handling systems.
The Krystal 24 plate edges and lids are designed to reduce evaporation, and the
raised well rims reduce the risk of cross contamination. Porvair Krystal 24
lids are shaped to facilitate stacking. Krystal 24 plates and lids may be
supplied sterile or non-sterile.
The unique Krystal 24 design also provides the convenience of direct measurements
on bottom reading spectrophotometers and inverted microscopes. For sensitive
fluorescence measurements the black Krystal 24 plate provides the all-absorbing
background needed to minimise background interference. The opaque white
Krystal 24 plate maximises reflectivity enabling even weakly emitting
luminescence assays to be routinely undertaken.
For further information about the Krystal 24 microplate range please contact
Porvair Sciences Ltd. on +44-1372-824290 or email int.sales@porvair-sciences.com.
The Model OFCU-1 from Exeter Analytical provides a highly safe tool for
preparing samples for elemental analysis of Halogens, Phosphorus and Sulfur
using the Oxygen Flask Combustion procedure.
The oxygen flask combustion procedure is provided as the preparatory step in
the determination of bromine, chlorine, fluorine, iodine, phosphorus and sulfur
in some Pharmacopeial articles. Combustion of the material under test (usually
organic) yields water-soluble inorganic products, which may be analysed for
specific elements as directed in the individual Pharmacopeia monograph or
general chapter. The oxygen flask combustion procedure using the attractively
priced OFCU-1 is capable of being used for repeatable determination of
elemental composition from percentage levels to parts per million.
The durably constructed Oxygen Flask Combustion Unit (OFCU-1) copes easily with
a wide range of sample types and is very simple to set up, use and maintain.
Built with operator safety in mind, the OFCU-1 remotely ignites samples inside
a safety interlocked chamber using focused infrared heat from two
tungsten-halogen lamps. Integral pressure vents ensure safe release of excess
reaction pressure. A thick black acrylic observation window is provided on the
OFCU-1 to allow users to visually check ignition has taken place.
As a company dedicated to elemental microanalysis, Exeter Analytical’s nearly
30 years of involvement with instruments, consumables and supplies has allowed
them to better understand the whole problem facing micro analysts. As a
consequence whether you are a regular or an occasional purchaser - experienced
and knowledgeable staff are always available to provide free informed advice.
Available online 10 December
2012 Publication year: 2012 Source:TrAC Trends in Analytical
Chemistry
This review extensively covers information on chemiluminescence
(CL)-reaction systems, which generate reactive oxygen species (ROSs) [e.g.,
superoxide radicals, singlet oxygen, hydroxyl radicals and peroxynitrite] from
the decomposition of hydrogen peroxide and their analytical applications. We
discuss the advantages and the limitations of applying CL methods to routine
analysis.
Highlights
► Chemiluminescent reaction systems generate
reactive oxygen species (ROSs). ► Reactive oxygen species (ROSs) can detection
of various analytes. ► Analyte structure is related to chemiluminescence
intensity. ► Chemiluminescence methods have high sensitivity and a wide linear
range. ► Chemiluminescence methods may be more sensitive and more
selective.
Available online 7 December
2012 Publication year: 2012 Source:TrAC Trends in Analytical
Chemistry
Microorganism contamination is a permanent concern in a wide
range of fields, including the water-treatment, food and pharmaceutical
industries, in which fast detection is critical to prevent microbial outbreaks.
In water monitoring, current procedures for water-quality analysis are based on
periodic sampling and detection by culture methods, which are slow, requiring
24–48 h for completion, so that, when first results reach the decision-takers
and trigger an alarm, significant time has already passed and the population may
have been exposed to a health hazard There is a need for rapid, reliable
detection of contaminants in a broad spectrum of water-management situations.
For real-time detection, on-line monitoring seems to be the ideal approach, but
the need to adjust the available techniques to autonomous operation and the
optimization of response time are substantial challenges. This review presents
the findings of an identification study about the state-of-the-art of
technologies and commercial devices for on-line biomonitoring of water quality,
specifically for the detection of fecal contamination. We also include studies
dealing with verification or use of these devices.
Highlights
► Real-time detection of pathogens versus grab
sampling plus laboratory analysis. ► Techniques for microbial detection
identified and assessed for on-line potential. ► Market review of instruments
for monitoring of fecal contamination of waters. ► Instruments were applied to
water analysis and their performance reported.
Available online 7 December
2012 Publication year: 2012 Source:TrAC Trends in Analytical
Chemistry
Recent years have seen an upsurge of interest in developing a
low-cost, easy-to-operate, reliable preconcentration technique for precise
determination of ultra-trace concentrations of metal ions in aqueous matrices.
Dispersive liquid-liquid microextraction (DLLME) is a novel sample-preparation
technique offering high enrichment factors from low volumes of water samples. We
compare DLLME, cloud-point extraction and other microextraction techniques. We
also highlight the current best practices for analysis and chemical speciation
of metal ions in highly salted media. We strongly recommend the stripping
voltammetric technique at modified electrodes coupled to DLLME and other
microextraction techniques to develop low-cost, precise methods for ultra-trace
concentrations of metal ions in biological and environmental samples.
Highlights
► Dispersive liquid-liquid microextraction (DLLME)
applied, even in high salt liquids. ► Comparison of applications of
sample-extraction techniques. ► Limitations of dispersive liquid-liquid
microextraction (DLLME) coupled for analysis. ► Outlook for future applications
of dispersive liquid-liquid microextraction (DLLME).
Available online 4 December
2012 Publication year: 2012 Source:TrAC Trends in Analytical
Chemistry
The increasing use of metallic nanoparticles (MNPs) in a wide
variety of applications has led to an urgent need to evaluate the impact of
these new materials on human health and the environment. To date, the potential
toxicity of MNPs and their interaction mechanisms with cells and living
organisms have not been fully addressed. In this article, we discuss the
different bioanalytical strategies that have been used for this purpose. We
consider different methods aiming to evaluate cellular uptake and localization
in cells and tissues, and in-vitro methods for the study of the toxicity induced
by MNPs, considering different toxicity markers and high-throughput approaches
for the identification of specific targets involved in the cell-MNP interaction.
We also discuss special strategies related to the use of animal models to assess
in-vivo toxicity of MNPs.
Highlights
► A review on the different methods for evaluating
the toxicity of MNPs is presented. ► Methods. ► for cellular uptake and
localization are discussed. ► In-vitro cytotoxicity assays for assessing the
toxicity of MNPs are described. ► Characteristics of the in-vivo models used for
toxicity assays are reviewed.
Available online 3 December
2012 Publication year: 2012 Source:TrAC Trends in Analytical
Chemistry
The first worldwide interlaboratory study on persistent organic
pollutants (POPs) under the Stockholm Convention was organized in the
Asian/Pacific, South American and African regions during 2009–11. A relatively
large number of laboratories reported data for the PCDD/PCDF and dioxin-like
PCBs, especially in the Asian region. Within the Asian region, several
participants used high-resolution GC/high-resolution MS systems optimized for
dioxin analysis. High-resolution capacity is limited for the Latin America and
African regions, although recently several new laboratories for dioxins have
started in the Latin American region.
Highlights
► The first assessment of the quality of dioxin
analysis in developing countries. ► A critical evaluation of the statistical
methods used to validate QA/QC data. ► A comparison of the analytical variation
with the international literature. ► The first assessment of regional quality in
both developed and developing regions.
December 2012 Publication year:
2012 Source:TrAC Trends in Analytical Chemistry, Volume 41
The
generation of calibrated vapor samples of explosives compounds remains a
challenge due to the low vapor pressures of explosives, adsorption of explosives
on container and tubing walls, and the requirement to manage (typically)
multiple temperature zones as the vapor is generated, diluted, and delivered.
Methods that have been described to generate vapors can be classified as
continuous or pulsed-flow vapor generators. Vapor sources for continuous-flow
generators are typically explosives compounds supported on a solid support, or
compounds contained in a permeation or diffusion device. Sources are held at
elevated isothermal temperatures. Similar sources can be used for pulsed vapor
generators; however, pulsed systems may also use injection of solutions onto
heated surfaces with generation of both solvent and explosives vapors, transient
peaks from a gas chromatograph, or vapors generated by programmed thermal
desorption. This article reviews vapor-generator approaches with emphasis on the
method of generating the vapors and on practical aspects of vapor dilution and
handling. In addition, a gas chromatograph system with two ovens that is
configurable with up to four heating ropes is proposed, and could serve as a
single integrated platform for explosives-vapor generation and device testing.
We also discuss issues related to standards, calibration, and safety.
Highlights
► Methods to generate vapors of explosives compounds
are reviewed. ► Generators deliver either a known concentration or a known mass
of vapor. ► Vapor generators are classified as either continuous or pulsed flow.
► Issues of standards, calibration and safety are also
discussed.
December 2012 Publication year:
2012 Source:TrAC Trends in Analytical Chemistry, Volume
41
Supported ionic-liquid phases (SILPs), which favorably combine the
properties of ionic liquids (ILs) with the advantages of solid supports, were
presented in 2009 as an alternative material for solid-phase extraction (SPE).
Since then, the number of SILPs used as SPE materials has increased and the
results are promising. This report covers various aspects of SILPs:
the procedure for their preparation, which clearly depends on
the support (based on silica or polymer) where the ILs are immobilized;
their interaction mechanisms, which are strongly linked to
the SPE protocol and the target analytes; and, their fields
of application with a number of selected examples. This is the first review that
exclusively describes all SILPs that have been developed to date as sorbents in
SPE.
Highlights
► Review of supported ionic-liquid phase (SILPs)
used in solid-phase extraction (SPE). ► We review the different preparation
approaches to support ionic liquids. ► We discuss the interaction mechanisms
aroused on supported ionic-liquid phase (SILPs). ► Applications of supported
ionic-liquid phase (SILPs) in solid-phase extraction (SPE).
December 2012 Publication year:
2012 Source:TrAC Trends in Analytical Chemistry, Volume
41
Functional foods (FFs) are food products to be consumed as part of a
balanced diet. They provide physiological benefits or reduce the risk of chronic
disease beyond basic nutritional functions. Functional foods containing
probiotics and/or prebiotics have gained much interest in recent years due to
their health-promoting capacity. The main objective of this review is to discuss
the analytical strategies that have been used to validate FFs associated with
dairy products containing probiotics and/or prebiotics. In these products, the
biochemical events, carried out by enzymes of different sources (milk, bacteria,
rennet) leading to the transformation of milk to diverse products (e.g., yoghurt
and cheese), are glycolysis, proteolysis and lipolysis. We present the
analytical methodologies used to study the microbial probiotic flora and to
evaluate the biochemical transformations, the associated functionality in terms
of intestinal microbiome and the safety of such FFs. We address the analytical
figures of merit. We cover the advantages and the disadvantages of such
analytical methodologies and comment on future applications and potential
research interest within this field.
Highlights
► Functional dairy foods (FDFs) play important roles
in promoting health and well-being. ► Monitoring bacteria and biochemical events
in functional dairy foods (FDFs). ► Molecular and non-molecular methods are
complementary in microbiota characterization. ► Advanced biochemical analyses
have enabled probing for bioactive compounds. ► Omics technologies assess impact
of functional dairy foods (FDFs) on gut microbiome.
December 2012 Publication year:
2012 Source:TrAC Trends in Analytical Chemistry, Volume
41
Nucleic-acid aptamers are promising affinity ligands in affinity
chromatography. The relatively small size of aptamers and their ease of chemical
conjugation to chromatographic supports make high-density aptamer columns useful
for affinity separation. Other key features of aptamers pertinent to their
applications in affinity chromatography include their good stability, high
purity, and desirable binding properties. This article describes the current
status of aptamer affinity chromatography (AAC) in separation, extraction,
purification and detection of targets of interest, ranging from small molecules
to proteins and cells. Further development and applications of AAC can benefit
from the recent advances in aptamer-selection techniques, chromatographic
stationary-phase supports, nanomaterials and microfluidic manipulations.
Highlights
► Nucleic-acid aptamers are promising ligands in
affinity chromatography. ► We describe the current status and applications of
aptamer affinity chromatography. ► We cover separation, extraction,
purification, and detection of targets of interest. ► Advances contributing to
aptamer affinity chromatography include aptamer selection, stationary-phase
supports, and nanomaterials.
JM Science’s AQUACOUNTER®
Volumetric Karl Fischer Titrator (AQV-300) is reliable, easy-to-use and has
state-of-the-art performance features which allows measure of moisture content
from low to high concentrations quickly
and accurately. Measurements are simple and routine with unsurpassed precision.
Calculation functions include – concentration, factor standardization,
statistics, and recalculation.
The AQV-300 has six built-in calculation modes to
accommodate solid, liquid and gas samples.
Four files with preset conditions can be stored in memory and allows
instant recall of data for up to 20 samples. This unit comes with a small
footprint with integrated magnetic stirrer. A newly designed buret tip ensures
precise titration. Two RS-232C ports are convenient for balance and computer
interfaces for GLP and ISO documentation. It is CE
approved.
Comes
with DVD training movie, plasticized Quick-Start guide for use in the lab,
paper and pdf manual. Also included, complete accessories, download software
for transferring results to a laptop or PC, and RS-232 cable. Choice of thermal
printer or impact printer is available. Competitive pricing makes this the
perfect unit for budget conscience laboratories.
The Genevac Flip-Flop system is an innovative tool designed to facilitate post
ASE® concentration and preparation of samples. Samples are collected in the
special Flip-Flop tube, the funnel and vial are fitted, the tube flipped over
and second cap removed.
Your ASE sample can now be concentrated directly into a GC autosampler vial
using a Genevac ROCKET Evaporator. The Genevac ROCKET Evaporator enables rapid
concentration or evaporation of up to 18 Dionex ASE® vials simultaneously.
Using this simple procedure eliminates manual transfer steps and helps automate
the ASE® sample concentration / preparation process resulting in improved
laboratory workflow, increased reproducibility of results and enhanced sample
recovery.
Genevac, part of the SP Scientific group, was founded in 1990. Today the
company employs around 85 people, with manufacturing, R&D and marketing
headquartered in Ipswich, UK. Genevac today offers a comprehensive portfolio of
evaporators to suit almost any solvent removal application, purchasing budget
or productivity requirement.