World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Monday, 3 June 2013

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Chromatography A

Selected papers from the latest issue:

Recent development and applications of dispersive liquid–liquid microextraction

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Hongyuan Yan , Hui Wang
Dispersive liquid–liquid microextraction (DLLME) is a modern sample pretreatment technique that is regarded as consilient with the current trends of modern analytical chemistry. DLLME is simple, inexpensive, environmentally friendly, and could offer high enrichment factors from a wide gap between acceptor and donor phases. As a consequence, DLLME has attracted considerable attention from researchers and, based on the numerous publications concerning DLLME, has been generally accepted in separation science since the technique's invention in 2006. However, several innate weaknesses of DLLME, which restrict the technique's use in certain fields, have led to various attempts or suggestions to improve this technique. The present review focuses on the recent advances made in DLLME; the selected papers that are discussed in this work represent modifications that fall into three main categories (exploration of new extraction solvents, disperser solvents and combination with other techniques). The recent applications of DLLME in environmental, food and biological samples are also summarised, covering almost all of the publications related to the technology from the beginning. In addition, the feasibility of future trends of DLLME is discussed.

Development and comparison of two dispersive liquid–liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Shuhui Liu , Qilong Xie , Jie Chen , Janzhi Sun , Hui He , Xiaoke Zhang
In this study, two novel sample extraction methods for the analysis of bisphenol A (BPA) in edible oils were developed by using liquid–liquid extraction followed by a dispersive liquid–liquid microextraction (LLE-DLLME) and reversed-phase dispersive liquid–liquid microextraction (RP-DLLME). RP-DLLME showed a superior characteristic over LLE-DLLME and other previously reported procedures because of its easy operation, short extraction time, high sensitivity, low organic solvent consumption and waste generation. The optimized extraction conditions of RP-DLLME for 1.0g of edible oil diluted in 4mL of n-hexane were: extractant, 100μL 0.2M sodium hydroxide solution (80% methanol, v/v); extraction time, 1min; centrifugation, 3min. The determination of BPA was carried out by high performance liquid chromatography coupled with a DAD detector. The method offered excellent linearity over a range of 0.010–0.5μgg−1 with a correlation coefficient of r >0.997. Intra-day and inter-day repeatability values expressed as relative standard deviation were 1.9% and 5.9%, respectively. The quantitation limit and detection limit were 6.3 and 2.5ngg−1. The target analyte was detected in 5 out of 16 edible oil samples. The recovery rates in real samples ranged from 89.5 to 99.7%.

Development of a simultaneous multiple solid-phase microextraction-single shot-gas chromatography/mass spectrometry method and application to aroma profile analysis of commercial coffee

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Changgook Lee , Younghoon Lee , Jae-Gon Lee , Alan J. Buglass
A simultaneous multiple solid-phase microextraction-single shot-gas chromatography mass spectrometry (smSPME-ss-GC/MS) method has been developed for headspace analysis. Up to four fibers (50/30μm DVB/CAR/PDMS) were used simultaneously for the extraction of aroma components from the headspace of a single sample chamber in order to increase sensitivity of aroma extraction. To avoid peak broadening and to maximize resolution, a simple cryofocusing technique was adopted during sequential thermal desorption of multiple SPME fibers prior to a ‘single shot’ chromatographic run. The method was developed and validated on a model flavor mixture, containing 81 known pure components. With the conditions of 10min of incubation and 30min of extraction at 50°C, single, dual, triple and quadruple SPME extractions were compared. The increase in total peak area with increase in the number of fibers showed good linearity (R 2 =0.9917) and the mean precision was 12.0% (RSD) for the total peak sum, with quadruple simultaneous SPME extraction. Using a real sample such as commercial coffee granules, aroma profile analysis was conducted using single, dual, triple and quadruple SPME fibers. The increase in total peak intensity again showed good linearity with increase in the number of SPME fibers used (R 2 =0.9992) and the precision of quadruple SPME extraction was 9.9% (RSD) for the total peak sum.

Preparation of a polar monolithic coating for stir bar sorptive extraction of emerging contaminants from wastewaters

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Núria Gilart , P.A.G. Cormack , Rosa Maria Marcé , Francesc Borrull , Núria Fontanals
A new polar monolith based on poly(poly(ethylene glycol) methacrylate-co-pentaerythritol triacrylate) (poly(PEGMA-co-PETRA)) was first synthesised, after the optimisation of the polymerisation conditions, and applied as a coating for the stir bar sorptive extraction (SBSE) of a group of pharmaceuticals and personal care products (PPCPs) from environmental water samples. Several parameters affecting extraction and liquid desorption in SBSE were investigated to achieve the optimal sorption efficiencies for the studied analytes. Under the optimised experimental conditions, a rapid, simple and sensitive SBSE performance was provided by the in-house monolithic stir bar. Moreover, the in-house coating was able to extract and desorb most of the studied analytes more effectively and quickly, due to its polar behaviour and suitable mechanical and physical properties, in comparison with the recently commercialised polar stir bars (EG Silicone Twister® and Acrylate Twister®). The analytical methodology, including SBSE followed by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS), was validated and successfully applied for the determination of a group of PPCPs in wastewater samples.

Identification of metabolites of honokiol in rat urine using 13C stable isotope labeling and liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Juan Liu , Minghai Tang , Huijun Lai , Yinfeng Dong , Caifeng Xie , Haoyu Ye , Liang Ma , Neng Qiu , Yanfang Li , Lulu Cai , Lijuan Chen
A general approach based on stable isotope labeling and UPLC/Q-TOF-MS analysis of in vivo novel metabolites of honokiol has been developed in our study. In this method, urine samples were collected after intravenous administration of mixture of regular and [13C6]-labeled honokiol at 1:1 ratio to healthy rats. The metabolites could be easily recognized by the determination of a chromatographically co-eluted pair of isotopomers (MS doublet peaks) with similar peak intensities and mass difference corresponding to that between isotope-labeled and non-isotope-labeled honokiol. A total of 51 metabolites were detected, 37 of which were tentatively identified based on mass accuracy (<5ppm). Among them, 33 of honokiol metabolites were first reported with 5 metabolites belonging to phase I and other 32 metabolites belonging to phase II metabolites. Our results highlighted that the main phase I metabolic pathways of honokiol in rats were oxidation, and the phase II metabolic pathways were sulfation, glucuronidation, acetylation as well as amino acids conjugation. This was the first research focused on the biotransformation of honokiol in rats, and the identification of these metabolites might provide us essential information for further pharmacological and clinical studies of honokiol.

Multi-residue analytical method for the determination of endocrine disruptors and related compounds in river and waste water using dual column liquid chromatography switching system coupled to mass spectrometry

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Marina Gorga , Mira Petrovic , Damià Barceló
The present study describes a novel, fully automated method, based on column switching using EQuan™ columns for an integrated sample preconcentration and liquid chromatography coupled to tandem mass spectrometry (LC–LC–MS/MS). The method allows the unequivocal identification and quantification of the most relevant environmental endocrine disruptors compounds (EDCs) and compounds suspected to be EDCs, such as natural and synthetic estrogens and their conjugates, antimicrobials, parabens, bisphenol A, alkylphenolic compounds, benzotriazoles, and organophosphorus flame retardants, in surface river water and wastewater samples. Applying this technique, water samples were directly injected into the chromatographic system and the target compounds were concentrated into the loading column. Thereafter, the analytes were transferred into the analytical column for subsequent detection by MS–MS (QqQ). A comparative study employing three types of columns, with different chemical modifications, was performed in order to determine the optimal column that allowed maximum retention and subsequent elution of the analytes. Using this new optimized methodology a fast and easy online methodology for the analysis of EDCs in surface river water and wastewater with low limits of quantification (LOQ) was obtained. LOQs ranged from 0.008 to 1.54ng/L for surface river water and from 0.178/0.364 to 12.5/25.0ng/L (except for alkylphenol monoethoxylates) for effluent/influent waste water. Moreover, employing approximately 1h, a complete analysis was performed which was significant improvement in comparison to other methods reported previously. This method was used to track the presence and fate of target compounds in the Ebro River which is the most important river in Spain whose intensive agricultural and industrial activities concentrate mainly close to the main cities in the basin, deteriorating soil and water quality.

Study of the peak variance in isocratic and gradient liquid chromatography using the transport model

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Weiqiang Hao , Bin Di , Qiang Chen , Junde Wang , Yongbin Yang , Xiaoli Sun
The expressions accounting for the peak variance in isocratic and gradient liquid chromatography is derived from the transport model. In mathematical treatments, the dwelling time is taken into account, and the type of solvent strength, gradient profile and the variation of plate height (H) with mobile phase composition (φ) is not specified. By applying a coordinate transformation, the transport model is solved by using the Laplace transform approach. A plate height equation that is suited for both isocratic and gradient elution is obtained. Based on this equation, the plate height equations for any combination of stepwise and linear gradients are derived. These equations will be algebraic when the solvent strength is linear and the H–φ plot is parabolic. The plate height equations for single stepwise, single linear and the ladder-like gradients are also given.

Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Andrea Wagner , Brigitte Raue , Heinz-Jürgen Brauch , Eckhard Worch , Frank T. Lange
A new method for the determination of trace levels of adsorbable organic fluorine (AOF) in water is presented. Even if the individual contributing target compounds are widely unknown, this surrogate parameter is suited to identify typical organofluorine contaminations, such as with polyfluorinated chemicals (PFCs), and represents a lower boundary of the organofluorine concentration in water bodies. It consists of the adsorption of organofluorine chemicals on a commercially available synthetic polystyrene-divinylbenzene based activated carbon (AC) followed by analysis of the loaded AC by hydropyrolysis combustion ion chromatography (CIC). Inorganic fluorine is displaced by excess nitrate during the extraction step and by washing the loaded activated carbon with an acidic sodium nitrate solution. Due to its high purity the synthetic AC had a very low and reproducible fluorine blank (0.3μg/g) compared to natural ACs (up to approximately 9μg/g). Using this AC, fluoride and the internal standard phosphate could be detected free of chromatographic interferences. With a sample volume of 100mL and 2× 100mg of AC packed into two extraction columns combined in series, a limit of quantification (LOQ), derived according to the German standard method DIN 32645, of 0.3μg/L was achieved. The recoveries of six model PFCs were determined from tap water and a municipal wastewater treatment plant (WWTP) effluent. Except for the extremely polar perfluoroacetic acid (recovery of approximately 10%) the model substances showed fairly good (50% for perfluorobutanoic acid (PFBA)) to very good fluorine recoveries (100±20% for perfluorooctanoic acid (PFOA), perfluorobutanesulfonate (PFBS), 6:2 fluorotelomersulfonate (6:2 FTS)), both from tap water and wastewater matrix. This new analytical protocol was exemplarily applied to several surface water and groundwater samples. The obtained AOF values were compared to the fluorine content of 19 target PFCs analyzed by high performance liquid chromatography–electrospray tandem mass spectrometry (HPLC–(−)ESI-MS/MS). In groundwater contaminated by PFC-containing aqueous film-forming foams (AFFFs) up to 50% of the AOF could be attributed to PFC target chemicals, while in diffuse contaminated samples only <5% of the AOF could be identified by PFC analysis. 

Dual Channel Valveless Dispensing for Battery Manufacturing

The Fluid Metering PDS-100 Programmable Dispensing System is the solution for valveless electrolyte and slurry dispensing for battery manufacturing process applications requiring maintenance free, high precision fluid control.
The PDS-100 is designed for high accuracy, low volume dispensing of electrolytes, slurries, and metal forming lubricants used in the manufacture of AA, AAA, C, D, & Button Cell batteries. Internal pump components of the PDS-100 are made of chemically inert, sapphire-hard ceramics, making it ideal for dispensing corrosive KOH electrolytes, as well as viscous, abrasive slurries.
The PDS-100 design integrates FMI’s patented CeramPump® valveless piston pump technology with precision stepper motor control and integral electronics, all housed in a rugged space-saving enclosure suitable for countertop or wall mounting. Intuitive programming is menu-driven and accomplished using easy access front-panel membrane switches.
The dual channel configuration of the PDS-100 increases production output two fold at a fraction of the cost of two purchasing separate pumps. Furthermore, the dual channel version maintains full-featured independent pump control and footprint of the single channel version.
FMI’s patented CeramPump® valveless design accomplishes all fluid control functions with only one moving part, a single rotating and reciprocating piston made of chemically inert, sapphire-hard ceramics. Using dimensionally stable ceramic internal components while eliminating check valves, results in a dispensing system that will maintain 0.5 precision for millions of dispenses without recalibration.
The PDS-100 is available in single and duplex configurations to accommodate dispense and flow ranges from 2 microliters per dispense up to 1.5 liters per minute continuous pumping.
For over 50 years FMI pumps have been used for industrial automation, medical instrumentation, laboratory R&D, chemical process, pharmaceutical packaging, mining, alternative energy, water treatment, environmental monitoring, food processing and much more.

For additional information, Call toll free 1-800-223-3388 or 1-516-922-6050, FAX 1-516-624-8261, email: pumps@fmipump.com or visit our website at www.fmipump.com which now features “Live Help”, an online direct connection to FMI’s application experts.

Safe Storage of Noxious & Odorous Chemicals

The NEW Safestore™ Vented Chemical Storage Cabinets from Air Science are ideal for storage of noxious or odorous chemicals.
These cabinets minimize health and environmental risks in handling chemical vapors and residues, VOCs and general laboratory functions.
The Air Science Multiplex™ filtration system protects the safety of personnel during use, maintenance and decontamination.
Advanced carbon filtration technology offers a safe, high performance alternative to ducted cabinets for a broad range of applications.
Safestore cabinets isolate and trap biological and chemical vapors to prevent operator exposure, to prevent cross contamination, and to eliminate ecological impact through chemical or particulate release into the environment.
The Safestore cabinets are available in three capacities, 25 liters, 1,000 liters and 2,000 liters.
For additional information on Safestore Chemical Storage Cabinets, call, visit the website, or email Air Science USA.

Friday, 31 May 2013

Just Published: Journal of Analytical and Applied Pyrolysis

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Analytical and Applied Pyrolysis
http://rss.sciencedirect.com/publication/science/5247

Selected papers from the latest issue:

Aromatic Hydrocarbon Production by the Online Catalytic Cracking of Lignin Fast Pyrolysis Vapors using Mo2N/γ-Al2O3

30 May 2013, 16:58:57
Publication date: Available online 30 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Yan Zheng , Dengyu Chen , Xifeng Zhu
This study investigates the online catalytic cracking of lignin fast pyrolysis vapors using Mo2N/γ-Al2O3 prepared by nitriding an alumina-supported molybdenum oxide precursor with nitrogen hydrogen mixtures though temperature programming. The activity and selectivity of the catalyst toward aromatic hydrocarbons were determined in the pyrolysis-gas chromatography/mass spectrometry system. Results show that the catalyst has a significant function in the pyrolysis process. In the presence of the catalyst, the primary pyrolysis products from lignin are catalytically converted into aromatic products, benzene and toluene, as well as to an insignificant quantities of dimethylbenzene, ethylbenzene, trimethylbenzene, and naphthalene. The highest aromatic hydrocarbon yield of 17.5% is obtained using Mo2N/γ-Al2O3 (the catalyst-to-lignin weight ratio=4) at 700°C; by contrast, this yield is only 1.4% when no catalyst is used. Furthermore, the highest benzene yield of 70.1% is obtained using Mo2N/γ-Al2O3 (catalyst-to-lignin weight ratio=4) at 850°C. Under this condition, the monocyclic aromatic hydrocarbons together contribute >95% of the total aromatic hydrocarbon yield, whereas the selectivity toward naphthalene is only 2.2%.

PAHs emission from the pyrolysis of Western Chinese coal

30 May 2013, 16:58:57
Publication date: Available online 30 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Jie Dong , Zhu Cheng , Fan Li
Several organic and inorganic pollutants are released during coal utilization such as polycyclic aromatic hydrocarbons (PAHs). PAHs, due to their carcinogenic properties pose potential health hazards. The current work focus on the behaviour of the 16 PAHs during pyrolysis process, an important step of all coal thermal conversion including combustion, gasification, and carbonization. The experiments were performed using a CDS -5250 pyroprobe which could be heated fast. The pyroprobe was coupled with GC-MS (Thermo DSQII/FOCUS GC) and the pyrolysis products were analyzed in-situ. The emissions of the 16 USEPA priority-controlled polycyclic aromatic hydrocarbons from Western Chinese coal were measured under different pyrolysis conditions. The results showed that the emission concentrations of PAHs reach a maximum at a pyrolysis temperature of 800°C. Emission concentrations of PAHs decreased with increasing rates of pyrolysis heating. PAHs emmissions increased gradually with coal rank under the same pyrolysis conditions. A correlation between the yield of PAHs; coal rank and maceral was also demonstrated. Also in this study, the variety trend of the each specie of 16 PAHs with pyrolysis temperature were observed and the reasons were disccussed.

Exposure to valproic acid and 5,7-dimethoxycoumarin induces pheomelanogenesis in the human melanoma G-361 cells, as demonstrated by Py-GC/MS/MS study

30 May 2013, 16:58:57
Publication date: Available online 27 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Ewa Chodurek , Anna Dzierżęga-Lęcznar , Slawomir Kurkiewicz , Krystyna Stępień
Melanogenesis is one of the main markers of the differentiation of normal and neoplastically transformed melanocytes. Valproic acid (VPA) and 5,7-dimethoxycoumarin (DMC), the potential anti-cancer drugs with differentiating activity, were reported to enhance melanin synthesis in melanoma cells. The aim of this study was to examine if the stimulation with VPA and DMC affects the structure of melanin synthesized by the human melanoma G-361 cell line. G-361 cells were cultured with VPA, DMC, and a mixture of the two agents for 7 days. Melanin isolated from the treated and untreated cells were pyrolysed, and the thermal degradation products were analyzed by gas chromatography/tandem mass spectrometry with a triple quadrupole instrument operating in a multiple reaction monitoring mode. After the stimulation with VPA and DMC, the sulfur containing pyrolytic markers of pheomelanin were detected among the thermal degradation products of the pigment isolated from the tumor cells. The levels of pheomelanin markers were the highest after the cell treatment with the combination of both agents. No sulfur compounds were present in the pyrolysate of melanin from the untreated control cells. We have concluded that VPA and DMC are able to induce pheomelanogenesis, and thus alter the structure of melanin produced in the human melanoma G-361 cells.

Molecular Characteristics of Vermicompost and Their Relationship to Preservation of Inoculated Nitrogen-Fixing Bacteria

30 May 2013, 16:58:57
Publication date: Available online 27 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Dariellys Martinez-Balmori , Fábio Lopes Olivares , Riccardo Spaccini , Kamilla Pereira Aguiar , Marcelo Francisco Araújo , Natália Oliveira Aguiar , Fernando Guridi , Luciano Pasqualoto Canellas
The chemical nature of organic matter during the process of vermicomposting of cattle manure and filter cake from a sugar factory was characterized by thermochemolysis. The pyrolysates were mainly constituted of lignin moieties from propanoic acid units and short-chain (<C20) fatty acids (as methyl esters); alkanes, alkenes, terpenes and steroids were minor compounds. Nitrogen containing compounds were noticeable in filter cake vermicompost (VC) as were carbohydrate moieties. Despite thermochemolysis had shown low sensitivity for carbohydrates, the presence of a number of carbohydrate derivatives was indicative of extensive biological transformation of organic matter during vermicomposting. A high content of long-chain alcohols was found only in filter cake VC. At the end of VC maturation, the content of hydrophobic compounds (lignins plus fatty acids) in filter cake residues was higher than in cattle manure. This mature VC exhibited the highest natural density of culturable diazotrophic bacteria compared to cattle manure VC (approximately 104 times cells g−1 VC), and when the diazotrophic bacterium Herbaspirillum seropedicae was introduced to both types of VC, the population numbers were higher in filter cake VC at 10 months of storage after inoculation. We found an apparent relationship between molecular characteristics of organic matter and the harboring or preservation of diazotrophic bacteria introduced to VC, which is a step toward understanding the relationship between the molecular characteristics of organic matter and the microbial activities.

Thermal stability characterization of n-alkanes from determination of produced aromatics

30 May 2013, 16:58:57
Publication date: Available online 24 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Xiaomei Qin , Hai Chi , Wenjun Fang , Yongsheng Guo , Li Xu
The thermal stability of n-nonane and n-undecane, as the model endothermic hydrocarbon fuels, was evaluated by determining the content change of produced aromatics during the thermal cracking process. The 1H nuclear magnetic resonance spectroscopy (1H NMR), along with the high-performance liquid chromatography (HPLC) and the gas chromatography/mass spectrometry (GC/MS) analyses, is mainly considered to follow the formation of aromatics in the liquid cracking residues of the n-alkanes. The results of the aromatic contents obtained from these three analytical methods show satisfactory agreements. The 1H NMR method also gives the olefin content and the branching index of the liquid residues. The changes of the aromatics, olefins and branching index against the temperature directly reflect the thermal stability of the n-alkanes. Based on the results from 1H NMR, HPLC and GC/MS, a scheme of the formation of aromatics from the thermal cracking of n-alkanes is discussed.

Pyrolysis reactions of coniferyl alcohol as a model of the primary structure formed during lignin pyrolysis

30 May 2013, 16:58:57
Publication date: Available online 21 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Takeo Kotake , Haruo Kawamoto , Shiro Saka
It has been suggested that cinnamyl alcohol-type structures are formed during lignin primary pyrolysis using model dimers. In this article, the pyrolysis reactions of trans-coniferyl alcohol (CA) bearing a guaiacyl moiety were studied under N2 at temperatures in the range of 200–350°C, with particular emphasis on the evaporation/degradation processes. Some (less than 15%) of the CA evaporated without undergoing any degradation reactions, whereas large portions of the CA were converted to polymerization products together with monomers (up to ∼15% in total) with various side-chains. The cis-isomer of CA and 4-vinylguaiacol with a C2 side-chain were also identified. Methylation of the phenolic OH group of CA substantially reduced the formation of polymerization products, whereas the influence of the methylation on the side-chain-converted monomers was limited. Since the methylated CA was not effective for quinine methide formation, quinine methide and radical pathways were indicated as more important reaction mechanisms for the polymerization and side-chain-conversion processes, respectively. These results suggest that CA, if it was formed through pyrolytic cleavage of lignin β-ether linkages, tended to be degraded before it could be recovered through evaporation. Furthermore, the recovery of different monomers suggested the process was greatly dependent on the relative evaporation/degradation efficiencies.

Transformation of sulfur during pyrolysis of inertinite-rich coals and correlation with their characteristics

30 May 2013, 16:58:57
Publication date: Available online 21 May 2013
Source:Journal of Analytical and Applied Pyrolysis
Author(s): Meijun Wang , Yongfeng Hu , Jiancheng Wang , Liping Chang , Hui Wang
Sulfur transformation of inertinite-rich coals, which were sampled from three Western China coal mines, Xinjiang Hami (HM), Ningxia Lingwu (LW) and Shendong (SD), during pyrolysis is studied through measuring the release of H2S and COS gases by gas chromatography with flame photometric detector and through analyzing the sulfur forms in raw coals and chars from pyrolysis by X-ray absorption spectroscopy (XAS). It is revealed that the transformation of sulfur during coal pyrolysis is closely linked with coal properties, such as the vitrinite/inertinite ratio, alkaline mineral contents (especially calcium compounds) and H/C atomic ratio for three inertinite-rich coals. Comparisons are performed with a coal sample taken from Pingsuo (PS) coal mine located in North China, of which the properties are significantly different. The maximal release temperature of sulfur-containing gases for the pyrolysis of inertinite-rich coal is higher than that of the PS coal. The release of the S-containing gases in inertinite-rich coals has a maximal temperature interval around 600°C and this is associated with the conversions of inorganic sulfur species, such as pyrite transforming to FeS observed by the XAS in chars of these coals. During the process of pyrolysis, the organic sulfur compounds in inertinite-rich coal can be oxidized to form sulfoxide-like species due to the decomposition of oxygen-containing function groups in the coal matrix, but the active sulfur in PS coal can react with fresh char to form relatively stable thiophene structures. The formation of COS during the pyrolysis of inertinite-rich coals is mainly due to secondary reactions between H2S with CO and/or CO2. 

High Resolution NMR Analytical Services

Warwick Analytical Service (WAS) has produced an analytical service note that demonstrates the Nuclear Magnetic Resonance (NMR) specroscopic data the company is able to routinely achieve. 

Drawing upon expertise in the pharmaceutical, biotech, chemical, petrochemical and environmental markets - Warwick Analytical Service is able to offer NMR as an analytical service for structural elucidation of chemical structure, deformulation of products, quantification of mixture components, kinetic and temperature studies of reaction mixtures and calculation of impurity levels.  In addition – WAS is able to routinely offer NMR characterisation of polymers to elucidate structure, co-monomer ratios, end groups and average molecular weight.

With access to two modern high-resolution NMR instruments, offering analysis of nuclei including 1H, 13C, 19F and 31P, Warwick Analytical Service is able to offer the NMR solution you need whether it is to be applied to liquids, solids, gels or suspensions at µg – mg levels.

Warwick Analytical Service is a company dedicated to providing analytical excellence at a realistic cost. Through experienced staff, the latest analytical instrumentation and working closely with clients - WAS has established a strong reputation for informed personal service and delivering top quality data on time. 

For further information please visit www.warwickanalytical.co.uk/nmr.htm or contact Warwick Analytical Service on tel. +44 (0)2476 323 223 or email info@warwickanalytical.co.uk

Oxford Instruments announces ‘Nanoscale Plasma Processing Seminars’ in Beijing and Taiwan

Continuing on from the success of their previous program of Chinese Seminars which have attracted  over 200 participants, Oxford Instruments, leaders in the manufacture of plasma etch and deposition systems, will be holding two additional one day Seminars in Asia focussing on Nanoscale Plasma Processing. These events  are being held on the 14th May (Beijing, China) and 16th May (ITRI, Hsinchu, Taiwan), and will feature talks by a number of invited guest speakers, specialists from China, Taiwan and Europe, in addition to Process and Applications experts from Oxford Instruments Plasma Technology.
These academic and industrial experts will discuss topics including Atomic Layer Deposition (ALD), Photovoltaics (PV), Deep Silicon Etch, Power Devices, HBLED and Ion Beam technologies during the full one day programme.

Prof. Yang Fuhua, Institute of Semiconductors, CAS, Beijing is very pleased to be involved with the Beijing seminar, “We hosted a similar event with Oxford Instruments two years ago and it was a great success with attendance of over 100 people. The content was excellent with very informative talks from a diverse range of speakers. The events are a great means of finding out about new techniques in an informal setting, with plenty of time to speak to the experts!”

Jeffrey Seah, Asia Business Manager for Oxford Instruments Plasma Technology, who will open the Seminar comments: “We are anticipating a large audience at these Seminars in China and Taiwan, and are extremely honoured that so many distinguished speakers have accepted our invitation to speak about their work in Plasma Processing. Our Seminars are a great opportunity for the Plasma Processing community to come together, to share their experiences, and to learn more from leading international experts in their field.”

Based on the success of their previous Seminars in Beijing and Shanghai, Oxford Instruments anticipates a very high level of interest from both academic and production participants, attracted by such an interesting programme and prestigious speakers.


The event is free to attend, but booking is essential via process.news@oxinst.com,   lingling.wang@oxinst.com (Beijing seminar) or Maggie.tsai@oxinst.com (ITRI, Taiwan seminar)

Thursday, 30 May 2013

Just Published: Chemometrics and Intelligent Laboratory Systems

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Chemometrics and Intelligent Laboratory Systems
http://rss.sciencedirect.com/publication/science/5232

One-class partial least squares (OCPLS) classifier

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Lu Xu , Si-Min Yan , Chen-Bo Cai , Xiao-Ping Yu
One-class partial least squares (OCPLS) classifier is investigated as a tool for multivariate statistical quality control (MSQC). According to the OCPLS score distance (SD) and absolute centered residual (ACR) of predicted response, an object can be classified into one of the four groups: regular points (with a small SD and a small ACR), class outliers (with a small SD and a large ACR), good leverage points (with a large SD and a small ACR) and bad leverage points (with a large SD and a large ACR). The correlation between OCPLS distance measures and some existing methods, including D-statistic, Q-statistic and correlation coefficient (Pearson's r), is briefly discussed. OCPLS is applied to non-targeted detection of adulterations in whole milk powder using near-infrared (NIR) spectroscopy. The results demonstrate OCPLS can provide an effective tool for MSQC by including both SD and ACR of predicted response.

Quantitative Raman spectrometry: The accurate determination of analytes in solution phase of turbid media

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Jing Yang , Zeng-Ping Chen , Juan Zhang , Jing-Wen Jin , Yao Chen
The presence of scatterers in turbid media could severely distort the Raman measurements and thereby prevent accurate determination of analytes in turbid media. To address this issue, in this contribution, an advanced model, multiplicative effects model (MEM), has been derived to explicitly model the effects of scatterers on Raman measurements. Preliminary experimental results for a proof of concept system with varying turbidity levels demonstrated that MEM could effectively account for the detrimental multiplicative effects of scatterers and ultimately achieved accurate quantitative analysis of analyte of interest in turbid media with a relative prediction error of about 4.3%. The enhanced levels of accuracy obtained with MEM open up an avenue for prospective prediction studies in turbid media such as biological tissues by Raman spectrometry.

Model NOx emissions by least squares support vector machine with tuning based on ameliorated teaching–learning-based optimization

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Guoqiang Li , Peifeng Niu , Weiping Zhang , Yongchao Liu
The teaching–learning-based optimization (TLBO) is a new efficient optimization algorithm. To improve the solution quality and to quicken the convergence speed and running time of TLBO, this paper proposes an ameliorated TLBO called A-TLBO and test it by classical numerical function optimizations. Compared with other several optimization methods, A-TLBO shows better search performance. In addition, the A-TLBO is adopted to adjust the hyper-parameters of least squares support vector machine (LS-SVM) in order to build NOx emissions model of a 330MW coal-fired boiler and obtain a well-generalized model. Experimental results show that the tuned LS-SVM model by A-TLBO has well regression precision and generalization ability.

Rough set based wavelength selection in near-infrared spectral analysis

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Ying Dong , Bingren Xiang , Ying Geng , Wenbo Yuan
Rough set based procedure was proposed as a new methodology to select component-specific wavelengths for near-infrared (NIR) spectral analysis. Information gain (IG) was employed to regulate the size of the discernibility matrix and decrease the memory requirements of rough set based reduction. This procedure involved submitting the resulting subsets of wavelengths to the analytical models in question. The utility of this method was illustrated by an analysis of classification models for phenylalanine (Phe) in plasma. The wavelength selection algorithm was compared with correlation based feature selection (CRFS) method and consistency based feature selection (CSFS) approach. Model fit was assessed using 10-fold cross-validation (10-fold CV) and leave-one out (LOO) approach. The predictability of the model was evaluated by an external prediction set. Furthermore, another two NIR data sets, obtained from the published literatures, were used to develop the quantitative models and validate the rough set based wavelength selection method. This study demonstrates conclusively that reducts of rough set could preserve the spectra–structure relationship and provide reliable model variables for NIR analysis. The results also indicate that rough set algorithm may hold promise for application as an additional feasible technique to NIR band assignment. As a fast, simple and noninvasive measurement, it is hopeful to find a clinical use in the diagnosis of unusual Phe elevation with further research.

A chemometric approach to prediction of transmembrane pressure in membrane bioreactors

30 May 2013, 09:25:2
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Hiromasa Kaneko , Kimito Funatsu
Membrane bioreactors (MBRs) have been widely used to purify wastewater for reuse. However, MBRs are subject to fouling, which is the phenomenon whereby foulants absorb or deposit on the membrane. To enable chemical cleaning to be performed at an appropriate time, membrane fouling must to be predicted in the long term. There has been research on correlations among fouling phenomena, water quality variables, and operating conditions. Therefore, in this paper, we aimed to construct a chemometric or statistical model between the increase in the transmembrane pressure (TMP) and MBR parameters such as water quality variables and operating conditions and use this model to predict TMP. We analyzed three data sets measured in real industrial MBR plants and then confirmed that the constructed model could predict TMP over time with high accuracy. By applying the proposed method to process control, MBR plants will be operated effectively and stably.

A SEVA soft sensor method based on self-calibration model and uncertainty description algorithm

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Liu Yiqi , Huang Daoping , Li Zhifu
Soft sensors are widely used to estimate process variables that are difficult to measure online. However, due to poor quality of input data and deterioration of prediction model as time passes, soft sensors make poor performance. We have been constructing a principal component analysis (PCA) model before performing a prediction. Furthermore, the just-in-time (JIT) learning model has been improved and served as prediction model for self validating (SEVA) soft sensors. The proposed soft sensor not only carries out internal quality assessment but also generates multiple types of output data, including the prediction values (PV), input sensor status (ISS), validated measurement (VM), output sensor status (OSS) and the uncertainty values (UV) which represent the credibility of soft sensors' output. The effectiveness of the proposed SEVA soft sensors is demonstrated through a case study of a wastewater treatment process.

A toolbox to explore NMR metabolomic data sets using the R environment

30 May 2013, 09:25:22
Publication date: 15 July 2013
Source:Chemometrics and Intelligent Laboratory Systems, Volume 126
Author(s): Stéphane Balayssac , Sébastien Déjean , Julie Lalande , Véronique Gilard , Myriam Malet-Martino
We describe herein the implementation of graphical and statistical tools developed in the R free software environment to explore metabolomic data sets. This toolbox, available upon request from the authors for the latest releases, includes univariate, bivariate and multivariate existing approaches accompanied with various graphical displays and interactive facilities. Concretely, very basic knowledge in R is required: from Excel data files as input to graphical and numerical outputs the user is led through a set of questions he only has to answer. We illustrate the potential of the toolbox on a data set coming from a 1H NMR metabolomic study of cerebellums from a murine model of Alzheimer's disease. We show the complementarity of various graphical techniques in order to provide information easier to interpret. In particular, a simple correlation study can be highly meaningful, and competitive with a more sophisticated multivariate analysis, when using ad hoc graphical representations depending on the level of interest: global, multiple or single metabolite focus.