World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Thursday, 6 June 2013

Drying of Oil, Fuel and Fat Samples

Genevac, world leaders in solvent removal technology, has over 20 year’s experience of supplying evaporators for removal of solvents from oil, fat and fuel samples.

Oils, fats and fuels are normally isolated from natural sources using extraction or separation techniques that present the final sample in a solution of organic solvent. Before analysis such samples must be dried or concentrated.

Whether extracting and recovering additives, evaluating lipid content of foods, characterising reclaimed cooking oils before reprocessing / conversion to biofuels, or investigating drillling test samples - oils, fuels and fats can often prove difficult to dry without using very high temperatures which may lead to loss of the more volatile fractions within the sample.

For many such applications, researchers have found that the Genevac EZ-2 and Rocket Evaporators have significantly enhanced recovery and results.  When working with larger solvent volumes, additional benefit is gained by way of productivity savings when using Genevac evaporators with SampleGenie technology which enables large volumes to be concentrated or dried directly into a small vial. 

Many oil and fat analyses require use of potentially explosive solvents, such as di-ethyl ether.  These can be safely evaporated in Genevac systems fitted with the Inert Gas Purge option, which removed all the air from the system before use, replacing it with inert gas and thereby preventing incident.

For further information including access to a series of technical papers describing Genevac evaporators being used for drying of oils, fats and fuels please visit http://www.genevac.com/en/Application.asp?S=10&V=1&Page=97 or contact the company on +44-1473-240000 / salesinfo@genevac.co.uk

Wednesday, 5 June 2013

Just Published: Journal of Chromatography B

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Selected papers from the latest issue:

Determination of deltonin in rat plasma by using HPLC–MS/MS and the application of this method in pharmacokinetic studies

05 June 2013, 09:36:17
Publication date: 15 July 2013
Source:Journal of Chromatography B, Volume 931
Author(s): Dan Du , Bo Gao , Guang Xin , Aimin Sun , Baozhan Huang , Rui Zhang , Zhihua Xing , Qianming Chen , Yang He , Wen Huang
Deltonin is a naturally occurring spirostanol glycoside from Dioscorea zingiberensis C.H. Wright, which is used in traditional Chinese medicine. It exerts strong cytotoxic effect on C26 cells, inhibits C26 derived-tumor growth, and prolongs the survival of tumor-bearing mice after its oral administration, indicating its potential for use as an anti-tumor drug. To investigate the pharmacokinetic profiles of deltonin, a rapid, sensitive, and simplified high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) assay was developed and validated for the determination of deltonin in rat plasma. After acetonitrile-mediated plasma protein precipitation, chromatographic separation of deltonin was achieved using a reversed phase Hypersil Gold column (150mm×2.1mm, 5μm), with gradient elution using 0.1% formic acid and acetonitrile. Thereafter, deltonin was quantified using MS/MS with electrospray ionization (ESI) in positive multiple reaction monitoring (MRM) mode. The flow rate of the mobile phase was 200μL/min, and the retention time was 9.03min for deltonin and 6.31min for the internal standard (IS: 20(S)-ginsenoside Rb1). The linear range of the calibration curve was 2–5000ng/mL (r 2 >0.99), and the limit of detection (LOD) was 0.46ng/mL. The intra- and inter-day accuracies ranged from −2.8% to 11.1% and precisions (RSD) were within 13.1%. Deltonin was found to be stable under short-term temperature conditions, post-preparative temperature conditions, and after 3 freeze–thaw cycles conditions. The validated method was successfully applied to a pharmacokinetic study in rats after oral administration of deltonin (50 and 100mg/kg). The pharmacokinetics is characterized by high apparent clearance (CL/F) and apparent volume of distribution (Vd/F).

Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography–tandem mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Chun-Ru Cheng , Min Yang , Shu-Hong Guan , Xiao-Hui Wu , Xiao-Yan Pang , Yang Wang , Yi Yang , Jie Ding , De-An Guo
The present study aims to investigate the pharmacokinetics of ganoderic acid D (GD), a representative active triterpenoid from Ganoderma lucidum. A sensitive and selective liquid chromatography–tandem mass spectrometry method was developed for the simultaneous determination of the concentrations of GD and its main metabolite (ganoderic acid B) in rat plasma. Following protein precipitation, the analytes were separated on a reversed-phase C18 column. Acetonitrile–water–acetic acid (40:60:0.01) was used at a flow-rate of 0.2ml/min. A triple quadrupole mass spectrometer equipped with an electrospray ionization source was used as the detector and was operated in the negative ion mode. Multiple reaction monitoring using the characteristic transitions was performed to quantify the analytes. The method had a lower limit of quantification of 8.19ng/ml for GD, and 8.59ng/ml for ganoderic acid B (GB). The calibration curves were demonstrated to be linear over the concentration range of 8.19–4096ng/ml and 8.59–2149ng/ml, respectively. Variations within- and between-batch were less than 6.4% and 4.6%, respectively. The extraction recovery rates ranged from 98.8 to 105.2% and 100.7 to 113.6%, respectively. The validated method was successfully applied to the quantification of GD and GB concentrations in rat plasma after oral administration (or intravenous administration) of GD preparations at a dose of 15mg/kg. The data showed that the absolute bioavailability increased from 22% to 70% after the GD suspension was changed to GD loaded solid lipid nanoparticles. In the meantime, the C max increased from 107.2 to 1555.6ng/ml; the t max changed from 2.0h to 0.3h. These results are very helpful in the further studies.

Quantitative analysis of autoinducing peptide I (AIP-I) from Staphylococcus aureus cultures using ultrahigh performance liquid chromatography–high resolving power mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Hiyas A. Junio , Daniel A. Todd , Keivan A. Ettefagh , Brandie M. Ehrmann , Jeffrey S. Kavanaugh , Alexander R. Horswill , Nadja B. Cech
Staphylococcus aureus infections acquired in hospitals now cause more deaths per annum in the US than does HIV/AIDS. Perhaps even more alarming is the rise in community associated methicillin-resistant S. aureus (CA-MRSA) infections, which have spread out of hospital settings and are infecting otherwise healthy individuals. The mechanism of enhanced pathogenesis in CA-MRSA remains unclear, but it has been postulated that high activity in the agr quorum-sensing system could be a contributing factor. The purpose of this study was to develop a quantitative method for analysis of autoinducing peptide I (AIP-I), the activating signal for the agr system in S. aureus. An effective method was developed using ultrahigh performance liquid chromatography (UHPLC) coupled to electrospray ionization mass spectrometry with an LTQ Orbitrap mass spectrometer. Relying on the exceptional resolving power and mass accuracy of this instrument configuration, it was possible to quantify AIP-I directly from the complex growth media of S. aureus cultures with a limit of detection (LOD) of 0.25μM and a linear dynamic range of 2.6 to 63μM. The method was then employed to monitor time-dependent production of AIP-I by S. aureus cultures, and it was observed that AIP-I production reached a maximum and leveled off after approximately 16h. Finally, it was determined that virulence of S. aureus was correlated with AIP-I production in some (but not all) strains analyzed.

Para-aminobenzamidine linked regenerated cellulose membranes for plasminogen activator purification: Effect of spacer arm length and ligand density

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Ezio Fasoli , Yiaslin Ruiz Reyes , Osiris Martinez Guzman , Alexandra Rosado , Vivian Rodriguez Cruz , Amaris Borges , Edmarie Martinez , Vibha Bansal
Despite membrane-based separations offering superior alternative to packed bed chromatographic processes, there has been a substantial lacuna in their actual application to separation processes. One of the major reasons behind this is the lack of availability of appropriately modified or end-group modifiable membranes. In this paper, an affinity membrane was developed using a commercially available serine protease inhibitor, para-aminobenzamidine (pABA). The membrane modification was optimized for protein binding capacity by varying: (i) the length of the spacer arm (SA; 5-atoms, 7-atoms, and 14-atoms) linking the ligand to membrane surface; (ii) the affinity ligand (pABA) density on membrane surface (5–25nmol/cm2). Resulting membranes were tested for their ability to bind plasminogen activators (PAs) from mono- and multi-component systems in batch mode. The membrane containing pABA linked through 7-atoms SA but similar ligand density as in the case of 5- or 14-atoms long SA was found to bind up to 1.6-times higher amounts of PA per nmoles of immobilized ligand from conditioned HeLa cell culture media. However, membranes with similar ligand densities but different lengths of SA, showed comparable binding capacities in mono-component system. In addition, the length of SA did not affect the selectivity of the ligand for PA. A clear inverse linear correlation was observed between ligand density and binding capacity until the point of PA binding optima was reached (11±1.0nmol/cm2) in mono- and multi-component systems for 7- as well as 14-atoms SA. Up to 200-fold purification was achieved in a single step separation of PA from HeLa conditioned media using these affinity membranes. The issues of ligand leaching and reuse of the membranes were also investigated. An extensive regeneration procedure allowed the preservation of approximately 95% of the PA binding capacity of the membranes even after five cycles of use.

Rapid multi-method for the determination of growth promoters in bovine milk by liquid chromatography–tandem mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): George Kaklamanos , Georgios Theodoridis
A rapid multi-method was developed for the determination of 21 growth promoters from different classes, including gestagens, corticosteroids, RALs, stilbenes, steroids in bovine milk by liquid chromatography–tandem mass spectrometry (LC–MS/MS). All compounds were eluted from the analytical column in less than 8.5min and were subsequently analyzed with atmospheric pressure chemical ionization (APCI) using both positive and negative mode. Sample preparation included extraction of the compounds with acetonitrile and purification with solid-phase extraction (SPE). The method was validated according to Commission Decision 2002/657/EC, at a validation level of 1ng/ml. The specificity, accuracy, precision, decision limit (CCα) and the detection capability (CCβ) were satisfactory evaluated. The recoveries ranged from 80.7% to 118.8% and reproducibility represented as coefficient of variance (CV) was from 1.8% to 13.0%. The CCα and CCβ values were in the ranges 0.06–0.10ng/ml and 0.11–0.17ng/ml, respectively. The developed method was applied in real samples proving its rapidness and sensitivity for the determination of the 21 growth promoters.

Detection and quantification of quinolone signalling molecule: A third quorum sensing molecule of Pseudomonas aeruginosa by high performance-thin layer chromatography

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Anju Bala , Ravi Kumar Gupta , Sanjay Chhibber , Kusum Harjai
Sophisticated network of quorum sensing involves the production of chemical signals which regulate the combined expression of virulence genes and biofilm formation in Pseudomonas aeruginosa. Two well-characterized acyl homoserine lactone based las and rhl systems together with alkyl quinolone based Pseudomonas quinolone signalling (PQS) are fundamental components of this network. Third signalling molecule, 2-heptyl-3-hydroxy-4-quinolone (PQS) is of paramount importance because of its interconnecting role in quorum sensing hierarchy in P. aeruginosa. Accurate detection of PQS molecule is very important to understand the involvement of this system in infection process of P. aeruginosa. In this study, high performance-thin layer chromatography (HP-TLC) method was developed for detection as well as quantification of PQS signal molecules in P. aeruginosa, which combines conventional method like TLC with sophisticated instrumentation. This method was validated using parameters like linearity, accuracy, precision, reproducibility and sensitivity. Intra- and inter-day accuracy and precision values were determined which were found to be within acceptable level and hence showed reproducibility. Measurement of PQS in the range of 0.01nmol indicated excellent sensitivity of this approach for quantifying PQS molecule. Automated sampling, rapid and simultaneous analysis of large number of samples and minimal errors make this method more suitable for analysis of PQS signalling molecules. Production of PQS was found to be strain dependent since variation in amount of PQS was observed among different P. aeruginosa isolates. Further, PQS production was also dependent on growth phase of P. aeruginosa with maximum production in late stationary phase.

An improved GC–MS method in determining glycerol in different types of biological samples

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Yixiao Shen , Zhimin Xu
Glycerol is an important compound participating in the lipid metabolism and energy conversion of body. Its level, especially in the blood circulation, has been considered as an index in assessing the triglycerides level, fat mobilization and potential risk of hyperlipidemia. In this gas chromatography mass spectrometry (GC–MS) method, 1,2,3-butanetriol was selected as an internal standard instead of isotope labeled glycerol. The internal standard and sample were derivatized by trimethylsilyl imidazole. The glycerol and internal standard derivatives in the sample were measured by a selected ion monitor mode of GC–MS. The sensitivity and repeatability of this method were examined by analyzing glycerol in eleven different types of biological tissue and fluid samples. The glycerol level in the measured mouse plasma sample was at 11.71±0.48μg/mL, while it was in a range of 0.15±0.01 (brain) to 0.39±0.02μg/mg (liver) in the tissue samples. It was 27.06±0.12 and 1.60±0.04μg/mL in the tested human blood and urine samples, respectively. Also, the glycerol recoveries of all samples were higher than 80% and over 90% for the fluid samples, especially. With the satisfactory repeatability and recovery and non-isotope internal standard, the GC–MS method could be a reliable technique in monitoring the glycerol status of biological samples regardless of whether they are from a study in which isotope labeled glycerol or other stable isotope materials were involved.

Determination of nitrite and nitrate in cerebrospinal fluid by microchip electrophoresis with microsolid phase extraction pre-treatment

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Peter Troška , Richard Chudoba , Ladislav Danč , Róbert Bodor , Michal Horčičiak , Eva Tesařová , Marián Masár
A new method for the determination of nitrite and nitrate, indicators of various neurological diseases (meningitis, multiple sclerosis, Parkinson's disease) in cerebrospinal fluid (CSF) on an electrophoresis chip was developed. An on-line combination of isotachophoresis (ITP) with capillary electrophoresis (CE) on a poly(methylmethacrylate) chip assembled with coupled separation channels (CC) and contact conductivity detectors was employed. ITP separations performed at low pH (3.6) in the first separation channel enabled a highly selective transfer of the analytes to the second CE stage working under micellar conditions implemented by zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)-propanesulfonate. The proposed method achieved low limits of detection varied from 0.2 to 0.4μgL−1 when the sample volume injected onto the chip (9.9μl) was almost the same as the volume of both separation channels. Preferable working conditions on the CC chip (suppressed hydrodynamic and electroosmotic flow) contributed for reproducible migration velocities (intra-day reproducibility up to 2.1% RSD) and determinations of trace concentrations of nitrite and nitrate (intra-day precision up to 3.0% RSD). Huge amount of chloride present in CSF (approx. 4.5gL−1) was removed from analyzed CSF samples by microsolid phase extraction performed on silver-form resin prior to the ITP-CE analysis. Developed method provided fast (approx. 20min total analysis time) and reliable determinations of trace nitrite and nitrate and could be fully integrated into the analysis of CSF samples.

On-line screening of matrix metalloproteinase inhibitors by capillary electrophoresis coupled to ESI mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Xu Wang , Zhiying Dou , Yaozuo Yuan , Shuli Man , Kris Wolfs , Erwin Adams , Ann Van Schepdael
Capillary electrophoresis (CE) with the use of mass spectrometry (MS) has been considered as a unique tool for microscale enzyme assay and inhibitor screening. In this study, matrix metalloproteinase-9 (MMP-9) was selected as target enzyme due to its important role in tumor invasion and metastasis. In order to define the optimal MS parameters, a two level half fraction factorial experimental design was performed. A background electrolyte consisting of 20mM ammonium acetate (pH 6.8) and a sheath liquid of water–methanol (50:50, v/v) containing 0.05% formic acid at a flow rate of 4μl/min were selected. This system was operated in the positive ion mode with a detection-limit of 10nM for the MMP reaction product and provided 60 folds enhancement of sensitivity by using selected reaction monitoring detection compared with MS full scan mode, which significantly increased the detectability of the system and therefore reduced the enzyme reaction time in both off-line and in-line mode. Both electrophoretically mediated microanalysis and pressure mediated microanalysis combined with MS detection were investigated for MMP inhibitor screening. Good repeatability (RSD of peak area and migration time were lower than 5.0%) and linearity (R 2 >0.996) were obtained for both in-capillary approaches. Several tetracycline antibiotics and natural products were selected to test the system. The results indicated an agreement on the ranking of inhibitory potency for both in-capillary approaches.

Semi-preparative isolation of dihydroresveratrol-3-O-β-d-glucuronide and four resveratrol conjugates from human urine after oral intake of a resveratrol-containing dietary supplement

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Yulia Radko , Kathrine B. Christensen , Lars P. Christensen
A method for semi-preparative isolation of major resveratrol metabolites from human urine after oral intake of a trans-resveratrol-containing dietary supplement was developed. Pretreatment of the urine (6L) by using solid-phase extraction gave a brown oily residue (9.3g), which was separated using a combination of normal phase column chromatography and reversed-phase flash column chromatography resulting in fractions containing 1.1g crude trans-resveratrol-3-O-sulfate (M1), 86mg of a crude mixture of trans-resveratrol-3,5-O-disulfate (M2) and trans-resveratrol-3,4′-O-disulfate (M3), and 568mg of a crude mixture of trans-resveratrol-3-O-β-d-glucuronide (M4) and dihydroresveratrol-3-O-β-d-glucuronide (M5). Purification of the crude metabolites was performed by semi-preparative reversed-phase HPLC using a gradient of aqueous ammonium acetate (2.5mmol/L, pH 6.7)/acetonitrile for purification of M1, M2 and M3 or trifluoroacetic acid in water (pH 2.5)/acetonitrile for purification of M4 and M5. From a part of the crude metabolites (50–75mg), 47mg M1 (purity 98.7%), 14mg M2 (purity 96.1%), 10mg M3 (purity 96.3%), 38mg M4 (purity 98.2%) and 18mg M5 (purity 97.8%) were obtained. The structures of all isolated resveratrol metabolites were elucidated by spectroscopic and spectrometric methods such as 1D and 2D NMR, UV, and LC–MS. This method represents a novel approach to obtain resveratrol metabolites being the first method describing the direct isolation of pure resveratrol metabolites from urine samples in quantities sufficient for full chemical characterization and testing in vitro and in preclinical trials. 

Extended Mass Spec Imaging Services Now Available

Protea Biosciences, a leading developer of innovative bioanalytical products and services, announced today the release of an extended mass spectrometry imaging (MSI) service offering from the Mass Spec Imaging Center (MSIC™). This new service portfolio offers advanced MSI services using Protea’s proprietary LAESI DP-1000 Direct Ionization System as well as MALDI (Matrix-Assisted Laser Desorption/Ionization) mass spectrometry for a wide variety of sample types and applications.
“This new portfolio of services offers researchers an opportunity to ‘detect’ where their molecules of interest reside in a biological matrix,” said Alessandro Baldi PhD, Protea’s Vice President and General Manager. “This spatial information offers critical insight for researchers working in the fields like metabolomics, biomarker discovery, drug discovery, and histopathology.”
To highlight this extended service portfolio, Protea announced a Spring Webinar Series, which discusses various applications and technologies for mass spectrometric imaging. These webinars cover topics ranging from biomarker discovery to drug distribution profiling and in vivo applications using the LAESI technology.
The MSIC also serves as a demonstration and training facility to help researchers learn more about mass spectrometry imaging using the tools and techniques developed at Protea.

For complete details on the Protea MSIC and the Spring Webinars, go to: https://proteabio.com/imaging

Entry Level Thermal Plate Sealer

The MicroSeal from Porvair Sciences is a manual microplate heat sealer designed to be compact, easy-to-use and offer great performance all with an affordable list price.

Of the various methods of sealing microplates, heating sealing has become the preferred option for many labs as it creates an air tight and chemically-resistant seal without the complications of adhesives being applied to a plate. Incorporating a unique ergonomic pull down mechanism makes single action heat sealing of a wide range of plates on the MicroSeal quick and simple.

Using a pre-set temperature of 170°C, ideal for most common sealing applications, and dual LED status display of power and heating, the MicroSeal is very safe and easy to use. A built-in thermostat prevents overheating of plates.

With its small footprint, ease of use and ability to handle a wide range of plates the MicroSeal is the obvious choice for laboratories looking for an affordable manual thermal plate sealer.

Porvair Sciences Ltd has specialised in the manufacture of microplates and microplate equipment since its formation in 1992. Via its global distributor network, Porvair Sciences serves Life Sciences, Biotechnology, R&D and Molecular Biology with microplate solutions for all applications, from sample preparation to high throughput screening.  Porvair Sciences is a subsidiary of Porvair plc, a world leader in microporous materials.

For further information on the MicroSeal please contact Porvair Sciences on telephone +44-1372-824290, email int.sales@porvair-sciences.com or visit the website at http://www.porvair-sciences.com/en/services-menu/equipment/microseal-manual-thermal-plate-sealer/

Monday, 3 June 2013

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Chromatography A

Selected papers from the latest issue:

Recent development and applications of dispersive liquid–liquid microextraction

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Hongyuan Yan , Hui Wang
Dispersive liquid–liquid microextraction (DLLME) is a modern sample pretreatment technique that is regarded as consilient with the current trends of modern analytical chemistry. DLLME is simple, inexpensive, environmentally friendly, and could offer high enrichment factors from a wide gap between acceptor and donor phases. As a consequence, DLLME has attracted considerable attention from researchers and, based on the numerous publications concerning DLLME, has been generally accepted in separation science since the technique's invention in 2006. However, several innate weaknesses of DLLME, which restrict the technique's use in certain fields, have led to various attempts or suggestions to improve this technique. The present review focuses on the recent advances made in DLLME; the selected papers that are discussed in this work represent modifications that fall into three main categories (exploration of new extraction solvents, disperser solvents and combination with other techniques). The recent applications of DLLME in environmental, food and biological samples are also summarised, covering almost all of the publications related to the technology from the beginning. In addition, the feasibility of future trends of DLLME is discussed.

Development and comparison of two dispersive liquid–liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Shuhui Liu , Qilong Xie , Jie Chen , Janzhi Sun , Hui He , Xiaoke Zhang
In this study, two novel sample extraction methods for the analysis of bisphenol A (BPA) in edible oils were developed by using liquid–liquid extraction followed by a dispersive liquid–liquid microextraction (LLE-DLLME) and reversed-phase dispersive liquid–liquid microextraction (RP-DLLME). RP-DLLME showed a superior characteristic over LLE-DLLME and other previously reported procedures because of its easy operation, short extraction time, high sensitivity, low organic solvent consumption and waste generation. The optimized extraction conditions of RP-DLLME for 1.0g of edible oil diluted in 4mL of n-hexane were: extractant, 100μL 0.2M sodium hydroxide solution (80% methanol, v/v); extraction time, 1min; centrifugation, 3min. The determination of BPA was carried out by high performance liquid chromatography coupled with a DAD detector. The method offered excellent linearity over a range of 0.010–0.5μgg−1 with a correlation coefficient of r >0.997. Intra-day and inter-day repeatability values expressed as relative standard deviation were 1.9% and 5.9%, respectively. The quantitation limit and detection limit were 6.3 and 2.5ngg−1. The target analyte was detected in 5 out of 16 edible oil samples. The recovery rates in real samples ranged from 89.5 to 99.7%.

Development of a simultaneous multiple solid-phase microextraction-single shot-gas chromatography/mass spectrometry method and application to aroma profile analysis of commercial coffee

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Changgook Lee , Younghoon Lee , Jae-Gon Lee , Alan J. Buglass
A simultaneous multiple solid-phase microextraction-single shot-gas chromatography mass spectrometry (smSPME-ss-GC/MS) method has been developed for headspace analysis. Up to four fibers (50/30μm DVB/CAR/PDMS) were used simultaneously for the extraction of aroma components from the headspace of a single sample chamber in order to increase sensitivity of aroma extraction. To avoid peak broadening and to maximize resolution, a simple cryofocusing technique was adopted during sequential thermal desorption of multiple SPME fibers prior to a ‘single shot’ chromatographic run. The method was developed and validated on a model flavor mixture, containing 81 known pure components. With the conditions of 10min of incubation and 30min of extraction at 50°C, single, dual, triple and quadruple SPME extractions were compared. The increase in total peak area with increase in the number of fibers showed good linearity (R 2 =0.9917) and the mean precision was 12.0% (RSD) for the total peak sum, with quadruple simultaneous SPME extraction. Using a real sample such as commercial coffee granules, aroma profile analysis was conducted using single, dual, triple and quadruple SPME fibers. The increase in total peak intensity again showed good linearity with increase in the number of SPME fibers used (R 2 =0.9992) and the precision of quadruple SPME extraction was 9.9% (RSD) for the total peak sum.

Preparation of a polar monolithic coating for stir bar sorptive extraction of emerging contaminants from wastewaters

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Núria Gilart , P.A.G. Cormack , Rosa Maria Marcé , Francesc Borrull , Núria Fontanals
A new polar monolith based on poly(poly(ethylene glycol) methacrylate-co-pentaerythritol triacrylate) (poly(PEGMA-co-PETRA)) was first synthesised, after the optimisation of the polymerisation conditions, and applied as a coating for the stir bar sorptive extraction (SBSE) of a group of pharmaceuticals and personal care products (PPCPs) from environmental water samples. Several parameters affecting extraction and liquid desorption in SBSE were investigated to achieve the optimal sorption efficiencies for the studied analytes. Under the optimised experimental conditions, a rapid, simple and sensitive SBSE performance was provided by the in-house monolithic stir bar. Moreover, the in-house coating was able to extract and desorb most of the studied analytes more effectively and quickly, due to its polar behaviour and suitable mechanical and physical properties, in comparison with the recently commercialised polar stir bars (EG Silicone Twister® and Acrylate Twister®). The analytical methodology, including SBSE followed by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS), was validated and successfully applied for the determination of a group of PPCPs in wastewater samples.

Identification of metabolites of honokiol in rat urine using 13C stable isotope labeling and liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Juan Liu , Minghai Tang , Huijun Lai , Yinfeng Dong , Caifeng Xie , Haoyu Ye , Liang Ma , Neng Qiu , Yanfang Li , Lulu Cai , Lijuan Chen
A general approach based on stable isotope labeling and UPLC/Q-TOF-MS analysis of in vivo novel metabolites of honokiol has been developed in our study. In this method, urine samples were collected after intravenous administration of mixture of regular and [13C6]-labeled honokiol at 1:1 ratio to healthy rats. The metabolites could be easily recognized by the determination of a chromatographically co-eluted pair of isotopomers (MS doublet peaks) with similar peak intensities and mass difference corresponding to that between isotope-labeled and non-isotope-labeled honokiol. A total of 51 metabolites were detected, 37 of which were tentatively identified based on mass accuracy (<5ppm). Among them, 33 of honokiol metabolites were first reported with 5 metabolites belonging to phase I and other 32 metabolites belonging to phase II metabolites. Our results highlighted that the main phase I metabolic pathways of honokiol in rats were oxidation, and the phase II metabolic pathways were sulfation, glucuronidation, acetylation as well as amino acids conjugation. This was the first research focused on the biotransformation of honokiol in rats, and the identification of these metabolites might provide us essential information for further pharmacological and clinical studies of honokiol.

Multi-residue analytical method for the determination of endocrine disruptors and related compounds in river and waste water using dual column liquid chromatography switching system coupled to mass spectrometry

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Marina Gorga , Mira Petrovic , Damià Barceló
The present study describes a novel, fully automated method, based on column switching using EQuan™ columns for an integrated sample preconcentration and liquid chromatography coupled to tandem mass spectrometry (LC–LC–MS/MS). The method allows the unequivocal identification and quantification of the most relevant environmental endocrine disruptors compounds (EDCs) and compounds suspected to be EDCs, such as natural and synthetic estrogens and their conjugates, antimicrobials, parabens, bisphenol A, alkylphenolic compounds, benzotriazoles, and organophosphorus flame retardants, in surface river water and wastewater samples. Applying this technique, water samples were directly injected into the chromatographic system and the target compounds were concentrated into the loading column. Thereafter, the analytes were transferred into the analytical column for subsequent detection by MS–MS (QqQ). A comparative study employing three types of columns, with different chemical modifications, was performed in order to determine the optimal column that allowed maximum retention and subsequent elution of the analytes. Using this new optimized methodology a fast and easy online methodology for the analysis of EDCs in surface river water and wastewater with low limits of quantification (LOQ) was obtained. LOQs ranged from 0.008 to 1.54ng/L for surface river water and from 0.178/0.364 to 12.5/25.0ng/L (except for alkylphenol monoethoxylates) for effluent/influent waste water. Moreover, employing approximately 1h, a complete analysis was performed which was significant improvement in comparison to other methods reported previously. This method was used to track the presence and fate of target compounds in the Ebro River which is the most important river in Spain whose intensive agricultural and industrial activities concentrate mainly close to the main cities in the basin, deteriorating soil and water quality.

Study of the peak variance in isocratic and gradient liquid chromatography using the transport model

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Weiqiang Hao , Bin Di , Qiang Chen , Junde Wang , Yongbin Yang , Xiaoli Sun
The expressions accounting for the peak variance in isocratic and gradient liquid chromatography is derived from the transport model. In mathematical treatments, the dwelling time is taken into account, and the type of solvent strength, gradient profile and the variation of plate height (H) with mobile phase composition (φ) is not specified. By applying a coordinate transformation, the transport model is solved by using the Laplace transform approach. A plate height equation that is suited for both isocratic and gradient elution is obtained. Based on this equation, the plate height equations for any combination of stepwise and linear gradients are derived. These equations will be algebraic when the solvent strength is linear and the H–φ plot is parabolic. The plate height equations for single stepwise, single linear and the ladder-like gradients are also given.

Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography

03 June 2013, 08:31:53
Publication date: 21 June 2013
Source:Journal of Chromatography A, Volume 1295
Author(s): Andrea Wagner , Brigitte Raue , Heinz-Jürgen Brauch , Eckhard Worch , Frank T. Lange
A new method for the determination of trace levels of adsorbable organic fluorine (AOF) in water is presented. Even if the individual contributing target compounds are widely unknown, this surrogate parameter is suited to identify typical organofluorine contaminations, such as with polyfluorinated chemicals (PFCs), and represents a lower boundary of the organofluorine concentration in water bodies. It consists of the adsorption of organofluorine chemicals on a commercially available synthetic polystyrene-divinylbenzene based activated carbon (AC) followed by analysis of the loaded AC by hydropyrolysis combustion ion chromatography (CIC). Inorganic fluorine is displaced by excess nitrate during the extraction step and by washing the loaded activated carbon with an acidic sodium nitrate solution. Due to its high purity the synthetic AC had a very low and reproducible fluorine blank (0.3μg/g) compared to natural ACs (up to approximately 9μg/g). Using this AC, fluoride and the internal standard phosphate could be detected free of chromatographic interferences. With a sample volume of 100mL and 2× 100mg of AC packed into two extraction columns combined in series, a limit of quantification (LOQ), derived according to the German standard method DIN 32645, of 0.3μg/L was achieved. The recoveries of six model PFCs were determined from tap water and a municipal wastewater treatment plant (WWTP) effluent. Except for the extremely polar perfluoroacetic acid (recovery of approximately 10%) the model substances showed fairly good (50% for perfluorobutanoic acid (PFBA)) to very good fluorine recoveries (100±20% for perfluorooctanoic acid (PFOA), perfluorobutanesulfonate (PFBS), 6:2 fluorotelomersulfonate (6:2 FTS)), both from tap water and wastewater matrix. This new analytical protocol was exemplarily applied to several surface water and groundwater samples. The obtained AOF values were compared to the fluorine content of 19 target PFCs analyzed by high performance liquid chromatography–electrospray tandem mass spectrometry (HPLC–(−)ESI-MS/MS). In groundwater contaminated by PFC-containing aqueous film-forming foams (AFFFs) up to 50% of the AOF could be attributed to PFC target chemicals, while in diffuse contaminated samples only <5% of the AOF could be identified by PFC analysis. 

Dual Channel Valveless Dispensing for Battery Manufacturing

The Fluid Metering PDS-100 Programmable Dispensing System is the solution for valveless electrolyte and slurry dispensing for battery manufacturing process applications requiring maintenance free, high precision fluid control.
The PDS-100 is designed for high accuracy, low volume dispensing of electrolytes, slurries, and metal forming lubricants used in the manufacture of AA, AAA, C, D, & Button Cell batteries. Internal pump components of the PDS-100 are made of chemically inert, sapphire-hard ceramics, making it ideal for dispensing corrosive KOH electrolytes, as well as viscous, abrasive slurries.
The PDS-100 design integrates FMI’s patented CeramPump® valveless piston pump technology with precision stepper motor control and integral electronics, all housed in a rugged space-saving enclosure suitable for countertop or wall mounting. Intuitive programming is menu-driven and accomplished using easy access front-panel membrane switches.
The dual channel configuration of the PDS-100 increases production output two fold at a fraction of the cost of two purchasing separate pumps. Furthermore, the dual channel version maintains full-featured independent pump control and footprint of the single channel version.
FMI’s patented CeramPump® valveless design accomplishes all fluid control functions with only one moving part, a single rotating and reciprocating piston made of chemically inert, sapphire-hard ceramics. Using dimensionally stable ceramic internal components while eliminating check valves, results in a dispensing system that will maintain 0.5 precision for millions of dispenses without recalibration.
The PDS-100 is available in single and duplex configurations to accommodate dispense and flow ranges from 2 microliters per dispense up to 1.5 liters per minute continuous pumping.
For over 50 years FMI pumps have been used for industrial automation, medical instrumentation, laboratory R&D, chemical process, pharmaceutical packaging, mining, alternative energy, water treatment, environmental monitoring, food processing and much more.

For additional information, Call toll free 1-800-223-3388 or 1-516-922-6050, FAX 1-516-624-8261, email: pumps@fmipump.com or visit our website at www.fmipump.com which now features “Live Help”, an online direct connection to FMI’s application experts.

Safe Storage of Noxious & Odorous Chemicals

The NEW Safestore™ Vented Chemical Storage Cabinets from Air Science are ideal for storage of noxious or odorous chemicals.
These cabinets minimize health and environmental risks in handling chemical vapors and residues, VOCs and general laboratory functions.
The Air Science Multiplex™ filtration system protects the safety of personnel during use, maintenance and decontamination.
Advanced carbon filtration technology offers a safe, high performance alternative to ducted cabinets for a broad range of applications.
Safestore cabinets isolate and trap biological and chemical vapors to prevent operator exposure, to prevent cross contamination, and to eliminate ecological impact through chemical or particulate release into the environment.
The Safestore cabinets are available in three capacities, 25 liters, 1,000 liters and 2,000 liters.
For additional information on Safestore Chemical Storage Cabinets, call, visit the website, or email Air Science USA.