World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Wednesday, 23 October 2013

NEW Low Cost Mini Peristaltic Pump

AALBORG® Instruments is pleased to announce the introduction of the Model TPT low cost / low flow mini peristaltic pumps.
These New models feature Flow Rates from 1 ml/min up to 30 ml/min by selecting from a choice of 4 different RPM drives (8, 12, 17 or 25 RPM) and a choice of tubing sizes.
Direction of flow is reversible, clockwise or counterclockwise by use of the Control Switch (ON-OFF, CW-CCW Reversible settings).
The Motor is a continuous duty 24 VDC gear motor; brush style with internal permanent magnet. An optional Power Supply can be ordered separately providing 24 VDC, 1.08 Amp, 2.1mm, center positive DC jack.
An optional Counter indicates the number of revolutions; manual or remote “pre-set” feature.
Construction consists of a rigid metal housing, aluminum square tube and top and bottom plates. The Roller Head has 4 Rollers, glass-filled PTFE for trouble-free, quiet operation. The compact size provides a small 4" x 4" footprint.
Recommended tubing sizes include:1/32”ID X 1/32” wall; 1/16”IDX1/32”; 1/8”IDX1/32 which can be ordered in pre-cut lengths with appropriate connectors.
The TPT Pumps are ideal for many applications including pH control, fermentation equipment, nutrient dosing and environmental sampling functions.

Tuesday, 22 October 2013

Just Published: Microchemical Journal

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Selected papers from the latest issue:

Determination of reduced glutathione, cystein and total thiols in pine pollen powder by in situ derivatization

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Xiao-Yong Zhang , Yu-Lian Piao , Sheng-Yun Cui , Yong-Ill Lee
Glutathione (GSH), cystein (CySH) and total thiols in pine pollen powder were determined by spectrometric, fluorometric and high performance liquid chromatographic (HPLC) assays utilizing 5,5′-dithio-bis(2-nitrobenzoic acid) (DTNB, Ellman's reagent) and o-phthaldehyde (OPA) as derivatizing agents. The pollen samples were extracted with phosphate buffer solutions (PBS) containing excess derivatizing agents concomitant with ultrasonic cell rupture. In this way, thiol groups in the samples could be effectively blocked by in situ formation of relatively stable derivatizing products just after the pollen cell ruptured, thereby effectively preventing thiol groups from oxidation during sample preparation and making it possible to perform sensitive and accurate detections. Using a precolumn derivatization method, DTNB, GSH and CySH, as well as other thiol compounds can be determined or estimated by the HPLC method. Total thiols in the samples were determined by the spectrometric method using DTNB as the derivatizing agent. GSH was also selectively determined by the fluorometric method using OPA as the derivatizing agent. The detection results indicated that abundant thiol compounds, such as GSH, CySH and thiol protein, existed in pine pollen powder with measured amounts of 0.50–0.53μmol∙g−1 of GSH, 0.41μmol∙g−1 of CySH and 4.15μmol∙g−1 of total thiols.

Flow injection hydride generation for on-atomizer trapping: Highly sensitive determination of cadmium by tungsten coil atomic absorption spectrometry

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Piaopiao Chen , Yujia Deng , Kuncheng Guo , Xiaoming Jiang , Chengbin Zheng , Xiandeng Hou
Here we report the use of the tungsten-coil atomizer of a portable atomic absorption spectrometer as an on-atomizer trapping device and atomizer for the determination of trace cadmium, with flow injection hydride generation for production of volatile cadmium species from sample solutions. By mixing acidic analyte solution with tetrahydroborate solution, volatile cadmium species is produced and separated from the solution, and then transported and impacted onto the surface of the atomizer with a heating current set at 2.3A. Subsequent atomic absorption measurement was accomplished with in situ atomization at 8.5A. Compared to conventional direct injection, the sensitivity and the limit of detection were improved by 58- and 66-fold, respectively, based on 5.0mL sampling volume. In addition, use of flow injection significantly improved sample throughput. The proposed method was used for the analysis of several real water samples with good spiked recoveries.

Emerging issues on degradation by-products deriving from personal care products and pharmaceuticals during disinfection processes of water used in swimming pools

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Paola Bottoni , Lucia Bonadonna , Mattea Chirico , Sergio Caroli , Gyula Záray
The use of disinfection substances in the sanitation and disinfection processes of artificial water used for sports amenities and swimming pools has recently raised some serious concerns. Recreational Water Illnesses (RWIs) can put at serious risk the health of bathers and swimmers due to adverse effects caused by the use of disinfection chemicals, such as chlorine, chloramine, ozone and UV radiation, as well as their by-products. Remarkable documented evidence is available on the impact of Disinfection By-Products (DBPs), such as chloroform and other trihalomethanes, haloacetic acids and chlorophenols, deriving from the oxidation of common organic pollutants dissolved in raw, drinking, waste and artificial waters. Appropriate countermeasures, aimed at avoiding bathers' exposures to these chemicals, have been developed and adopted in public and private structures, also through important scientific contributions and technical provisions issued by the WHO and some national health authorities. On the other hand, it has been demonstrated that high reactive disinfection agents may transform other undesirable chemicals released by bathers, namely pharmaceuticals, sunscreens and other Pharmaceuticals and Personal Care Products (PPCPs) into chlorinated and oxidized compounds and nitrosamine precursors. The first symptoms of potentially adverse health effects on human subjects of these largely unknown by-products should be adequately taken into consideration and investigated.

Single-step procedure for trace element determination in synovial fluid by dynamic reaction cell-inductively coupled plasma mass spectrometry

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Franco Moyano , Ernesto Verni , Héctor Tamashiro , Silvia Digenaro , Luis D. Martinez , Raúl A. Gil
A fast and single-step procedure for the dissolution of human synovial fluid in formic acid and further determination by dynamic reaction cell-inductively coupled plasma mass spectrometry (DRC-ICPMS) with a high-efficiency sample introduction system was developed. The samples were collected, treated and analyzed in the same screw-capped tubes. In order to overcome the effect of considerable carbon content, the sample introduction, nebulization and ICP operating conditions were carefully optimized. Furthermore, DRC technology with CH4 as reaction gas was used for the elimination of spectral interferences due to polyatomic ions. The effect of the sample matrix was evaluated and mitigated through comparison of direct calibration against aqueous standards, direct calibration in formic acid media and analyte addition calibration. The recommended procedure involved low dilution and low detection limits (from 0.003μgL−1 for U to 13.3μgL−1 for Ti) with adequate precision (from 0.6% for Co to 6.6% for Ti). The proposed method was successfully applied to determine 16 trace elements in concentrations from 0.03μgL−1 (Cd) to 88.2μgL−1 (Cu) in human synovial fluid samples.

Modeling of second-order spectrophotometric data generated by a pH-gradient flow injection technique for the determination of doxorubicin in human plasma

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Mirta R. Alcaráz , Agustina V. Schenone , María J. Culzoni , Héctor C. Goicoechea
In this paper, the development of a pH-gradient flow-injection method with diode-array spectrophotometric detection combined with extended multivariate curve resolution–alternating least-squares (MCR–ALS) to quantitate doxorubicin in the presence of rifampicin in plasma samples is presented. Quantitation of doxorubicin was based on acid–base and spectral differences between its species and those for the interference. Overlapped profiles among the analyte and the interference were mathematically solved by data modeling with the well-known extended MCR–ALS algorithm. The method, which involves a simple sample pretreatment consisting in the addition of trichloroacetic acid followed by centrifugation, was applied to resolve validation mixtures composed of human plasma spiked with doxorubicin. Acceptable analytical figures of merit were obtained, i.e. recoveries from 96 to 107%, coefficients of variation between 0.2% and 7.8%, and limits of detection and quantification of 0.77 and 2.32μgL−1, respectively.

Graphical abstract

image

Effects of UV-dechloramination of swimming pool water on the formation of disinfection by-products: A lab-scale study

22 October 2013, 09:28:10
Publication date: January 2014
Source:Microchemical Journal, Volume 112
Author(s): Nicolas Cimetiere , Joseph De Laat
UV dechloramination has become a very popular process for reducing the concentration of chloramines in public swimming pool water. As the effects of this process on the formation of disinfection by-products (DBPs) remain a controversial issue, a bench-scale study has been undertaken to examine the impact of UV dechloramination on the formation of various DBPs. Four pool water samples were exposed to UV radiation at 254nm in the presence of free chlorine ([Cl2]0 =3mgL−1) and then chlorinated in the dark for 24h ([Cl2]0 =3mgL−1). High UV doses (up to 47kJm−2) were used to simulate cumulative UV doses received by real pool waters. The data showed that UV irradiation led to a 90% photodecay of free chlorine for UV doses ranging from 13 to 20kJm−2, to the formation of chlorate ion (0.05–0.11mol of chlorate/mole of free chlorine decomposed) and to a significant increase in the chlorine demand of pool water during the post-chlorination step. UV exposure followed by post-chlorination did not significantly affect the formation of haloacetic acids, led to a small increase in the concentrations of adsorbable organic halogen (AOX) and of chloral hydrate and markedly increased the formation of trihalomethanes (chloroform, bromodichloromethane, chlorodibromomethane), dichloroacetonitrile, 1,1,1-trichloropropanone and chloropicrin. 

Highly Affordable Lab Safety Shield

Asynt's Lab Safety Shield has been designed to neatly fit around popular brands of  stirrer hotplate to provide protection for chemists from draughts, splashes, aerosols and spills.

Ideal for use where fumehood space is at a premium, the compact and highly affordable Asynt Lab Safety Shield provides additional protection to chemists undertaking applications such as heated parallel reactions in tubes.. The device also beneficially shields reactions from the cooling effect of fumehood ventilation, particularly important when consistent and reproducible heating to parallel experiments is required.

Manufactured from robust 5mm polycarbonate, the Lab Safety Shield is resistant to a wide range of laboratory solvents and is temperature-resistant to 170°C.

Designed with a small footprint (29.5 x 16 x 17cm) to minimise use of valuable fumehood space, the shield maintains access to hotplate controls and gives good all-round visibility of the reaction or process. Manufactured in the UK, this is the only compact safety shield available for under £100 which fits Asynt, IKA and Heidolph stirrer hotplates. For further information please contact Asynt on +44-1638-781709 or sales@asynt.com.

Monday, 21 October 2013

Just Published: Journal of Pharmaceutical and Biomedical Analysis

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Pharmaceutical and Biomedical Analysis
http://rss.sciencedirect.com/publication/science/5266

Selected papers from the latest issue:

Improving the efficiency of quantitative 1H NMR: An innovative external standard–internal reference approach

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): Yande Huang , Bao-Ning Su , Qingmei Ye , Venkatapuram A. Palaniswamy , Mark S. Bolgar , Thomas V. Raglione
The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained.

Graphical abstract

image

Combined HPLC-DAD–MS, HPLC–MSn and NMR spectroscopy for quality control of plant extracts: The case of a commercial blend sold as dietary supplement

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): A. Karioti , E. Giocaliere , C. Guccione , G. Pieraccini , E. Gallo , A. Vannacci , A.R. Bilia
The efficiency of 1D and 2D NMR spectroscopy along with HPLC-DAD–MS analyses in characterising the content of a dietary supplement is demonstrated. Experiments directly performed on a lyophilised sample of a commercial product gave details on the quality control of the product. The lack of the marker constituents of some of the declared plant species (Crataegus oxyacantha, Olea europea, Capsella bursa-pastoris and Fumaria officinalis) and the presence of banned adulterants, responsible for the strong antihypertensive effect of the supplement were established. The analyses proved the presence of indole alkaloids belonging to the group of Rauwolfia sp., such as ajmaline, reserpine and yohimbine. Quantitative HPLC analysis showed that the content of reserpine in the product was in the therapeutic range and therefore responsible for the collapses of the patients.

Graphical abstract

image

Determination of pKa values of a triptolide derivative and its impurities by pressure-assisted capillary electrophoresis

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): Jian-Ling Wang , Xue-Jiao Xu , Dong-Ying Chen
A pressure-assisted capillary zone electrophoresis method was developed to determine the pK a values of a triptolide derivative (LLDT-246) and its impurities. The method was performed in an uncoated fused-silica capillary under the electric voltage of 18kV and 50mbar of external pressure applied simultaneously. A series of running electrolyte buffers were used with pH ranging between 2.2 and 10.0 with the constant ionic strength of 0.05M. The values of pK a of LLDT-246 and two impurities were calculated based on the pH dependence of effective mobilities (μ eff). The pK a value of LLDT-246 was in good agreement with that of determined by potentiometric titration method.

Improved detection of variants in recombinant human interferon alpha-2a products by reverse-phase high-performance liquid chromatography on a core–shell stationary phase

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): Yonghong Li , Chunming Rao , Lei Tao , Junzhi Wang , Barry Lorbetskie , Michel Girard
The detection of variants is one of the important aspects in quality control of recombinant DNA drugs. In this study, a gradient reverse-phase high-performance liquid chromatography (RP-HPLC) method with fluorescence detection is described for the separation of interferon alpha-2a (rhIFN α-2a) from several product related variants. The methodology employed a core–shell C18 column with a linear gradient elution of 0.2% (v/v) trifluoroacetic acid (TFA)-acetonitrile (ACN) at 1.0mL/min, and the temperature of the column was maintained at 60°C. The method was validated in terms of linearity, sensitivity, intra- and inter-day variations. Compared to the European Pharmacopeia RP-HPLC method of rhIFN α-2a analysis, this new method can separate N-methionylated variant in both drug substance and finished product, and analyze the variants in untreated, oxidized sample and slightly degraded samples more efficiently. In conclusion the method has an improved capability to detect variants in rhIFN α-2a products.

Graphical abstract

image

A novel sample preparation and on-line HPLC–DAD–MS/MS–BCD analysis for rapid screening and characterization of specific enzyme inhibitors in herbal extracts: Case study of α-glucosidase

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): D.Q. Li , J. Zhao , J. Xie , S.P. Li
Drug discovery from complex mixture like Chinese herbs is a challenge and extensive false positives make the obtainment of specific bioactive compounds difficult. In the present study, a novel sample preparation method was proposed to rapidly reveal the specific bioactive compounds from complex mixtures using α-glucosidase as a case. Firstly, aqueous and methanol extracts of 500 traditional Chinese medicines were carried out with the aim of finding new sources of α-glucosidase inhibitors. As a result, the extracts of fruit of Terminalia chebula (FTC), flowers of Rosa rugosa (FRR) and Eugenia caryophyllata (FEC) as well as husk of Punica granatum (HPG) showed high inhibition on α-glucosidase. On-line liquid chromatography–diode array detection–tandem mass spectrometry and biochemical detection (HPLC–DAD–MS/MS–BCD) was performed to rapidly screen and characterize α-glucosidase inhibitors in these four extracts. After tentative identification, most of compounds with inhibitory activity in the investigated crude extracts were found to be tannins commonly recognized as non-specific enzyme inhibitors in vitro. Subsequently, the four extracts were treated with gelatin to improve specificity of the on-line system. Finally, two compounds with specific α-glucosidase inhibition were identified as corilagin and ellagic acid. The developed method could discover specific α-glucosidase inhibitors in complex mixtures such as plant extracts, which could also be used for discovery of specific inhibitors of other enzymes.

Graphical abstract

image

Screening for multiple weight loss and related drugs in dietary supplement materials by flow injection tandem mass spectrometry and their confirmation by liquid chromatography tandem mass spectrometry

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): Fenhong Song , Douglas Monroe , Aref El-Demerdash , Cynthia Palmer
A new method has been developed using flow injection tandem mass spectrometry to semi-quantitatively screen for weight loss drugs, including sibutramine, N-desmethylsibutramine, N-didesmethylsibutramine, and phenolphthalein in dietary supplements. Positive identification of these drugs in samples was further confirmed and quantified by liquid chromatography tandem mass spectrometry. The degradation products of sibutramine were observed and identified by LC–MS/MS which include N-desmethylsibutramine, N-didesmethylsibutramine, N-formyldesmethylsibutramine, and N-formyldidesmethylsibutramine.

Graphical abstract

image

Phase quantification of antihypertensive drugs – Chlorthalidone, Hydrochlorothiazide, Losartan and combinations, Losartan/Chlorthalidone and Losartan/Hydrochlorothiazide – by the Rietveld method

21 October 2013, 01:15:21
Publication date: 25 January 2014
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 88
Author(s): Weberton Reis do Carmo , Fabio Furlan Ferreira , Renata Diniz
The identification and quantification of crystalline phases of antihypertensive drugs – Losartan potassium (LOS-K), Hydrochlorothiazide (HCTZ) and Chlorthalidone (CTD) were carried out by means of X-ray powder diffraction data and the Rietveld method. Quantitative phase analyses of Losartan potassium/Chlorthalidone (LOS-K/CTD) and Losartan potassium/Hydrochlorothiazide (LOS-K/HCTZ) combinations were also evaluated. The results indicated that for diuretics (HCTZ and CTD) only one crystalline phase was found in samples, and for LOS-K the crystal structure showed similarity between the Bragg peaks to the phase described as monoclinic and space group P21/c. After one year storage, the orthorhombic one was also observed in this sample.

Graphical abstract

image

Leading integrated laser company Nanoplus orders Oxford Instruments systems for laser bar facet coating and compound semiconductor etching

Oxford Instruments Plasma Technology (OIPT), one of the world’s key manufacturers of plasma etch and deposition systems, has just received an order from Nanoplus in Germany for an ion beam deposition and a plasma etch system for use on novel types of semiconductor laser production. Nanoplus produces semiconductor lasers over several wavelength ranges (some exclusively) for many different customers with a wide range of applications. The Ionfab300 Plus ion beam deposition is a multi-batch cassette loading tool allowing many devices to be produced for several applications and various customers in one load. The Ionfab300 Plus will be used for laser bar facet coating with anti-reflective and high-reflection multilayers, and the PlasmaPro System100 RIE system will be used for GaAs and InP compound etching.
 Dr David Pearson, OIPT’s Senior Ion Beam Technologist, comments, “Our Ionfab optical coating tools are becoming the tools of choice for many types of precision optical coatings worldwide, in particular in laser applications.”
 “Nanoplus is an internationally leading supplier of single mode DFB lasers for sensing, metrology, spectroscopy and telecom applications. We even have one of our sensors on NASA’s Mars Curiosity Rover.’, commented Prof. Dr. Alfred Forchel, founder of Nanoplus, ‘We chose Oxford Instruments systems for their versatility, superior process capabilities and excellent customer support.”
Frazer Anderson, Business Group Director at Oxford Instruments said, “Our tools offer the ideal platform for production as well as research & development in many new application areas, and Laser Bar facet coating is just one of these.  Our excellent process applications team and global service support ensure that our customers are supported in every respect and can count on their Oxford Instruments systems for maximum uptime and reliability.”

Friday, 18 October 2013

Just Published: Journal of Chromatography B

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Androgen glucuronides analysis by liquid chromatography tandem-mass spectrometry: Could it raise new perspectives in the diagnostic field of hormone-dependent malignancies?

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Eleni Kalogera , Constantinos Pistos , Xeni Provatopoulou , Sotirios Athanaselis , Chara Spiliopoulou , Antonia Gounaris
Breast and prostate constitute organs of intense steroidogenic activity. Clinical and epidemiologic data provide strong evidence on the influence of androgens and estrogens on the risk of typical hormone-dependent malignancies, like breast and prostate cancer. Recent studies have focused on the role of androgen metabolites in regulating androgen concentrations in hormone-sensitive tissues. Steroid glucuronidation has been suggested to have a prominent role in controlling the levels and the biological activity of unconjugated androgens. It is well-established that serum levels of androgen glucuronides reflect androgen metabolism in androgen-sensitive tissues. Quantitative analysis of androgen metabolites in blood specimens is the only minimally invasive approach permitting an accurate estimate of the total pool of androgens. During the past years, androgen glucuronides analysis most often involved radioimmunoassays (RIA) or direct immunoassays, both methods bearing serious limitations. However, recent impressive technical advances in mass spectrometry, and particularly in high performance liquid chromatography coupled with mass spectrometry (LC–MS/MS), have overcome these drawbacks enabling the simultaneous, quantitative analysis of multiple steroids even at low concentrations. Blood androgen profiling by LC–MS/MS, a robust and reliable technique of high selectivity, sensitivity, specificity, precision and accuracy emerges as a promising new approach in the study of human pathology. The present review offers a contemporary insight in androgen glucuronides profiling through the application of LC–MS/MS, highlighting new perspectives in the study of steroids and their implication in hormone-dependent malignancies.

(S)-1-(4-Dimethylaminophenylcarbonyl)-3-aminopyrrolidine: A derivatization reagent for enantiomeric separation and sensitive detection of chiral carboxylic acids by LC/ESI-MS/MS

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Shoujiro Ogawa , Hiroaki Tadokoro , Maho Sato , Takehisa Hanawa , Tatsuya Higashi
A novel derivatization reagent, (S)-1-(4-dimethylaminophenylcarbonyl)-3-aminopyrrolidine (1-DAPAP), was developed for increasing the detection sensitivity and enantiomeric separation of chiral carboxylic acids by liquid chromatography/electrospray ionization–tandem mass spectrometry (LC/ESI-MS/MS). 1-DAPAP reacted with carboxylic acids at room temperature within 5min in the presence of 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride. The epimerization (racemization) during the derivatization reaction was negligible. The resulting derivatives were highly responsive during the ESI-MS operating in the positive-ion mode and gave a characteristic product ion during the MS/MS, which enabled the sensitive detection using selected reaction monitoring; the detection responses of the 1-DAPAP-derivatives were increased by 10–1100-fold over the intact carboxylic acids and the limits of detection ranged from 0.97 and 5.2fmol on the column. The 1-DAPAP-derivatization was also effective for the enantiomeric separation of chiral carboxylic acids; the resolution values were 1.2–4.3 for the evaluated carboxylic acids. The derivatization procedure was successfully applied to biological sample analyses; the derivatization followed by LC/ESI-MS/MS enabled the separation and detection of trace amounts of ibuprofen and naproxen in human saliva with a simple pretreatment and small sample volume.

Determination of stilbenes and resorcylic acid lactones in bovine, porcine and poultry muscle tissue by liquid chromatography–negative ion electrospray mass spectrometry and QuEChERS for sample preparation

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Barbara Wozniak , Iwona Matraszek Zuchowska , Jan Zmudzki
Liquid chromatography tandem mass spectrometry method was developed and validated to confirm of resorcylic acid lactones: zeranol, taleranol, zearalanone, zearalenone, α and β-zearalenol and stilbenes in muscle tissue. The compounds were analyzed by LC–MS/MS QTrap 5500 apparatus in negative ionization mode. Chromatographic separation on Poroshell 120-EC C18 (150mm×2.1mm, 2.7μm) column was achieved at 45°C using isocratic elution of mobile phase – methanol/water (65:35, v/v). For the treatment of tissue samples prior to analysis, QuEChERS method was applied based on the extraction of analytes from muscle samples with ethyl acetate, separation of the aqueous and organic phases with application of magnesium sulphate and sodium acetate, the purification of the extract obtained by dispersive SPE with the use of sorbent C18, PSA and magnesium sulphate. The method was validated in accordance with the Commission Decision 2002/657/EC. Good recoveries were obtained (from 83% to 115%) as well as acceptable within-lab reproducibility (<22%). The values of the decision limit CCα and the detection capability CCβ for individual compounds are found to be below the recommended concentration set at 1μgkg−1 and not exceed 0.23μgkg−1 and 0.39μgkg−1, respectively. The elaborated method meets the criteria for confirmatory methods and is used in the official control of hormones.

Development of a high performance liquid chromatography method for quantification of isomers β-caryophyllene and α-humulene in copaiba oleoresin using the Box-Behnken design

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Vinícius Raphael de Almeida Borges , Ana Ferreira Ribeiro , Carina de Souza Anselmo , Lúcio Mendes Cabral , Valéria Pereira de Sousa
The sesquiterpene isomers, β-Cariofileno (CAR) and α-Humuleno (HUM) are the primary constituents of the copaiba oleoresin species. These natural products are primarily used by the Amazonian population and marketed as phytotherapies and cosmetics. The aim of this study was to develop and validate a method that simultaneously assays the isomers present in copaiba oleoresins by high performance liquid chromatography using the Box-Behnken design. After preliminary studies, the reverse phase chromatographic system was selected using a cyano column and a mobile phase consisting of acetonitrile and phosphate buffer. The Box-Behnken design was applied at three levels and with four independent variables: flow rate (X 1), gradient slope time (X 2), proportion of organic compounds at the end of the gradient (X 3) and at the beginning of the gradient (X 4). Also, the responses of the dependent variables: CAR retention time (Y 1) and the resolution between the CAR and HUM peaks (Y 2) was assessed. The mathematical model obtained from the regression results was satisfactory (R 2 >0.98, n =27) and showed a quadratic relationship where the effects of interactions between the variables, was observed by response surface graphs. The simultaneous optimization method was used to establish the best compromise of the resolution between the CAR and HUM isomers while adjusting the retention time of CAR. This method was successfully optimized by BBD obtaining chromatographic peaks with good symmetry, resolution and separation efficiency. The validation of the developed method confirmed its specificity, precision, accuracy and linearity in the range of 5.0–11.0 and 0.4–1.0μg/mL for CAR and HUM, respectively, and is considered suitable for routine applications which assure quality control.

Liquid chromatography–mass spectrometric determination of rufinamide in low volume plasma samples

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Zsolt Gáll , Szende Vancea , Maria T. Dogaru , Tibor Szilágyi
Quantification of rufinamide in plasma was achieved using a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method. The chromatographic separation was achieved on a reversed phase column (Zorbax SB-C18 100mm×3mm, 3.5μm) under isocratic conditions. The mobile phase consisted of a mixture of water containing 0.1% formic acid and methanol (50:50, v/v). The mass spectrometric detection of the analyte was in multiple reaction monitoring mode (MRM) using an electrospray positive ionization (ESI positive). The monitored ions were 127 m/z derived from 239 m/z rufinamide and 108 m/z derived from 251 m/z the internal standard (lacosamide). Protein precipitation with methanol was applied for sample preparation using only 50μl aliquots. The concentration range was 40–2000ng/ml for rufinamide in plasma. The limit of detection was 1.25ng/ml and the lower limit of quantification was established at 5ng/ml rufinamide concentration. Selectivity and matrix effect was verified using individual human, rat and rabbit plasma samples. Short-term, post-preparative and freeze–thaw stability was also investigated. The proposed method provides accuracy, precision and high-throughput (short runtime 4.5min) for quantitative determination of rufinamide in plasma. This is the first reported liquid chromatography–tandem mass spectrometric (LC–MS/MS) method for analysis of rufinamide from low volume plasma samples. The LC–MS/MS method was validated according to the current official guidelines and can be applied to accurately measure rufinamide level of large number of plasma samples from clinical studies or therapeutic drug monitoring.

Stereoselective analysis of nebivolol isomers in human plasma by high-performance liquid chromatography–tandem mass spectrometry: Application in pharmacokinetics

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Daniel Valente Neves , Carolina Pinto Vieira , Eduardo Barbosa Coelho , Maria Paula Marques , Vera Lucia Lanchote
Nebivolol is available for clinical use as a racemic mixture. Isomer d-nebivolol (SRRR) is a β1 adrenergic receptor blocker and its antipode, l-nebivolol (RSSS) is responsible for endothelium-dependent NO liberation. This report describes the development and validation of a method of analysis of nebivolol isomers in human plasma by high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). Nebivolol isomers were extracted from 2mL aliquots of plasma spiked with tramadol as internal standard, alkalinized and added of sodium chloride and diisopropyl ether:dichloromethane (70:30, v/v). Nebivolol isomers were resolved on a Chirobiotic® V column using methanol:acetic acid:diethylamine (100:0.15:0.05, v/v/v) as mobile phase. Protonated ion and respective ion product were monitored in transitions 406>151 for nebivolol and 264>58 for internal standard tramadol. There was no racemization of nebivolol isomers during the procedures of sample preparation and chromatographic analysis and matrix effect was absent. Analysis of nebivolol isomers showed linearity for plasma concentrations of 25–2500pg/mL of each isomer. The quantification limit was 25pg of each isomer/mL of plasma. Variation coefficients and inaccuracy calculated in precision and accuracy determinations were lower than 15%. Nebivolol was stable in human plasma after three successive cycles of freezing and thawing, during 4h at room temperature and after processing during 12h in the auto sampler at 5°C showing deviation values lower than 15%. The method was applied in a study of the kinetic disposition of nebivolol in plasma samples collected until 48h after administration of an oral single dose of 10mg of racemic nebivolol hydrochloride to a patient with systemic arterial hypertension. The clinical study demonstrated that the nebivolol pharmacokinetics is stereoselective. Isomer l-nebivolol showed higher AUC0–∞ (9.4ng/h/mL vs. 4.7ng/h/mL) and smaller apparent clearance (Cl/f) (531.8L/h vs. 1304.4L/h) when compared to antipode d-nebivolol.

MCM-41 solid phase membrane tip extraction combined with liquid chromatography for the determination of non-steroidal anti-inflammatory drugs in human urine

18 October 2013, 10:35:40
Publication date: 1 December 2013
Source:Journal of Chromatography B, Volume 940
Author(s): Sazlinda Kamaruzaman , Mohd Marsin Sanagi , Salasiah Endud , Wan Aini Wan Ibrahim , Noorfatimah Yahaya
Mesoporous silica material, MCM-41, was utilized for the first time as an adsorbent in solid phase membrane tip extraction (SPMTE) of non-steroidal anti-inflammatory drugs (NSAIDs) in urine prior to high performance liquid chromatography-ultraviolet (HPLC-UV) analysis. The prepared MCM-41 material was enclosed in a polypropylene membrane tip and used as an adsorbent in SPMTE. Four NSAIDs namely ketoprofen, diclofenac, mefenamic acid and naproxen were selected as model analytes. Several important parameters, such as conditioning solvent, sample pH, salting-out effect, sample volume, extraction time, desorption solvent and desorption time were optimized. Under the optimum extraction conditions, the MCM-41-SPMTE method showed good linearity in the range of 0.01–10μg/mL with excellent correlation coefficients (r =0.9977–0.9995), acceptable RSDs (0.4–9.4%, n =3), good limits of detection (5.7–10.6μg/L) and relative recoveries (81.4–108.1%). The developed method showed a good tolerance to biological sample matrices. 

Energy Efficient Freeze Drying Enhances Pharmaceutical Production

SP Scientific has produced a new technical brief that summarises the energy saving features available on its Hull range of production freeze drying systems.

Out of the many steps required to produce pharmaceuticals products, freeze drying is perhaps the most energy intensive of the various production processes.  Most of the energy consumed by a freeze dryer goes into the refrigeration system which must initially freeze the product and heat transfer shelves, and then condense water vapour that sublimates and desorbs out of the product during primary and secondary drying respectively.

For the last 20 years - Hull production freeze dryers have been at the forefront of pioneering ever more efficient use of the energy required to drive the lyophilisation process. This new technical brief details these energy saving technical innovations and explains how they translate into energy / cost savings in pharmaceutical production. 

Smart Cool® 4.0 technology utilizes the inherent flexibility of electronic expansion valves to capture greater compressor capacity under heavy loads (such as fast cooling of product) while at the same time allowing precise shelf control within +/- 1°C.  The result is that a typical Hull freeze dryer can meet or exceed the performance of other production freeze dryers using fewer and/or smaller compressors, especially when combined with MultiFlex® refrigeration.

Employing highly efficient heat transfer fluid cooled condensers - SP Scientific's proprietary MultiFlex refrigeration design enables Hull freeze dryers to meet process needs with fewer and/or smaller compressors, which results not only in significant energy savings, but overall reduced operational costs due to decreased maintenance requirements. 

In addition the document describes and explains the benefits of Screw Compressor technology, Variable Frequency Drives, Water Cooled Heat Exchangers and high efficiency liquid Nitrogen refrigeration systems.

To download a copy of this new technical brief please visit www.spscientific.com or for further information on energy efficient production scale freeze drying please contact SP Scientific’s Charles D. Dern, P.E. on +1-845-255-5000  or Chuck.Dern@SPScientific.com.