A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
This blog has been set up for editors, reviewers, authors and readers of Elsevier's Analytical Chemistry Journals - all of which can be seen below. It will be updated from Monday to Friday with general news and announcements concerning the titles listed on this page. It should be noted that the views or claims made in the news items and feeds are not necessarily those of the Publisher.
Thursday, 7 April 2011
Just Published: Biosensors & Bioelectronics
Wednesday, 6 April 2011
Just Published: Sensors & Actuators A: Physical
A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
SFT Introduces an Improved Supercritical Fluid Extractor
Supercritical Fluid Technologies (SFT) introduces a new bench top supercritical fluid extractor (SFE), the model SFT-110XW. This latest addition to the SFE product line builds upon the strengths of its popular predecessors, the SFT-100 and SFT-100XW. The completely redesigned restrictor valve with integrated micrometer allows for very precise flow control, which is essential for demanding applications. A completely removable oven lid and large side panel allow the user easy access to the high pressure vessel(s). An indicator light on the SFT-10 pump module alerts the user to proper operation of the Peltier pre-cooler, ensuring CO2 is maintained in the liquid state. A robust outlet from the restrictor ensures that users will not accidently damage the outlet tube when inserting it into the collection container. Extraction vessels up to 500 ml, single or dual configurations, afford maximum versatility.
Supercritical fluid extraction has become a popular alternative to traditional extraction methods that use organic solvents. Fast, efficient extraction of a variety of materials may be achieved using supercritical carbon dioxide. The SFT-110XW SFE is well suited for both research and process development applications. Precise control of temperature, pressure, and flow rate is essential for successful, reproducible extractions. The use of dual sapphire syringe pump technology, integrated pre-heaters, and precise flow control provides the precision required to achieve these goals. Process parameters developed in the laboratory are the key to the successful scale-up to pilot or production scale equipment.
For more information, please call us at 302-738-3420 or visit us on-line at www.supercriticalfluids.com.
Tuesday, 5 April 2011
Just Published: Journal of Pharmaceutical and Biomedical Analysis
A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
New Research Tools Catalog for Stem Cell Prep & Harvesting
Harvard Apparatus has a complete selection of products to assist you when you need to collect and harvest stem cells:
- Identification Products: Tattoo, Clips, RFID, Hair Removal Products
- Surgical Equipment: Operating Tables & Lights, Magnifiers
- Surgical Instruments: Tools, Needles, Sutures, Catheters, Sterilization Equipment
- Life Support: Ventilation Equipment, Anesthesia Systems, Recovery Chambers
- Vital Signs Monitoring: Capnography, Homeothermic Blankets, Pulse Oximeters, Blood Pressure, EKG
- Infusion Products: Drug Infusion, Nutrient Delivery, Stem Cell Injection
- 3D Bioreactors for Tissue Engineering and Whole Organ Regeneration.
This new catalog also has products for:
- CULTURING & GROWTH - 2D & 3D Bioreactors, Pumps, Organ & Tissue Perfusion and Imaging Chambers
- PHYSIOLOGICAL ASSESMENT & CONDITION MONITORING – Biopotentials, Capnography & Oxymetry, Blood Pressure & Flow, Data Acquisition & Analysis
Monday, 4 April 2011
Just Published: Analytica Chimica Acta
A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
http://rss.sciencedirect.com/publication/science/5216
http://rss.sciencedirect.com/publication/science/5216
New Hydrocarbon Trap Reduces Hydrocarbon to Trace Levels
JM Science announces their new Systech Hydrocarbon Trap for reducing hydrocarbon to trace levels for mass spectroscopy applications.
LC/MS (MS) or TOF/MS instrumentation has become extremely sensitive with increased resolution and processing speed. Thus it is imperative to remove background hydrocarbons for these very low trace determinations <15ppb. The hydrocarbon-trapping device is based on activated carbon and with minimum pressure loss. The new sensitivity significantly improves signal-to-noise and is ideal for all MS applications. This accessory is designed to be connected between a nitrogen gas generator and the LC/MS (MS) to TOF/MS. A choice of 20 liters/min and 40 liters/min flow rates can accommodate high gas flow rates. The 1/4 inch and 6mm fittings are included for use with most MS systems. The Hydrocarbon Trap offers 300 psi pressure limit (2.07MPa) and 572°F (100°C) temperature limit.
Subscribe to:
Posts (Atom)