World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Wednesday, 28 November 2012

FOSS releases new version of Vision


FOSS NIRSystems, Inc. has introduced Vision 3.60. Vision is a software package specifically designed for use with the FOSS NIRSystems Near-Infrared (NIR) laboratory and process analyzers. Vision 3.60 replaces earlier versions of Vision and offers support for the latest NIR laboratory and process hardware.

The main new features in Vision 3.60:
  • Vision 3.60 is 64 bit compatible. Vision can now be installed and run on both 32 bit and 64 bit versions of Windows XP, Windows Vista, and Windows 7.
  • Vision 3.60 supports the NIRS DS2500 Analyzer

If you are a current user of the FOSS Vision software, please contact us for more information and/or a complete list of new features appearing in version 3.60.

The FOSS Vision software is 21 CFR Part 11 compliant and supports PAT through numerous process analysis options and process communication capabilities. The software has an extensive security system with multiple access levels, secure data archiving and report generation as well as database and spreadsheet compatibility. Vision comes with a user-friendly electronic manual with tutorials and data for self taught hands-on method development and software operation.

Monday, 26 November 2012

Just Published: Analytica Chimica Acta


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Sensitive electrochemical detection of hydroxyl radical with biobarcode amplification

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Liang Wu, Yan Yang, Hejing Zhang, Gangbing Zhu, Xiaohua Zhang, Jinhua Chen
By using biobarcode nanoparticles, we have successfully constructed a DNA-based biosensor for amplified electrochemical detection of hydroxyl radical (OH). Thiolated DNA1 (SH-DNA1) was firstly immobilized on the planar gold (Au) electrode. OH generated from Fenton reaction could induce serious oxidative damage of the DNA layer adsorbed on the electrode surface, which was monitored by an intercalating probe, methylene blue (MB). In order to enhance the sensitivity of the biosensor, DNA2-functionalized Au nanoparticles (DNA2-AuNPs) were used to amplify the response signal. The developed DNA-based biosensor could detect OH quantitatively with wide linear range up to 10mM and low detection limit of 3μM, and exhibited satisfactory selectivity. On the other hand, this electrochemical biosensor could have potential application in the evaluation of antioxidant capacity.

Graphical abstract

image

Graphical abstract Highlights

.
► A DNA-based biosensor for amplified electrochemical detection of OH was developed. ► The sensor shows good analytical performance for sensitive detection of OH. ► The biosensor has potential application in the evaluation of antioxidant capacity.

Facile synthesis of graphene hybrid tube-like structure for simultaneous detection of ascorbic acid, dopamine, uric acid and tryptophan

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Wen Zhang, Yaqin Chai, Ruo Yuan, Shihong Chen, Jing Han, Dehua Yuan
In the present work, a tube-like structure of graphene hybrid as modifier to fabricate electrode for simultaneous detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp) was reported. The hybrid was synthesized by a simple method based on graphene sheets (GS) and 3,4,9,10-perylenetetracarboxylic acid (PTCA) via π–π stacking interaction under ultrasonic condition. The combination of GS and PTCA could effectively improve the dispersion of GS, owing to PTCA with the carboxylic-functionalized interface. Comparing with pure GS or PTCA modified electrode, GS–PTCA displayed high catalytic activity and selectivity toward the oxidation of AA, DA, UA, and Trp. Moreover, cyclic voltammetry, different pulse voltammetry and scanning electron microscopy were employed to characterize the sensors. The experiment results showed that the linear response range for simultaneous detection of AA, DA, UA, and Trp were 20–420μM, 0.40–374μM, 4–544μM and 0.40–138μM, respectively, and the detection limits were 5.60μM, 0.13μM, 0.92μM and 0.06μM (S/N =3). Importantly, the proposed method offers promise for simple, rapid, selective and cost-effective analysis of small biomolecules.

Graphical abstract

image

Graphical abstract Highlights

A tube-like structure of graphene hybrid (GS–PTCA) was synthesized via π–π stacking interaction, and was used as modifier to fabricate electrode for simultaneous detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). SEM images of GS, PTCA and GS–PTCA were presented. Under the synergistic effects between GS and PTCA, the modified electrode displayed high catalytic activity and selectivity toward the oxidation of AA, DA, UA, and Trp.
► A simple strategy for simultaneous detection of AA, DA, UA and Trp has been constructed. ► The tube-like structure of graphene hybrid (GS–PTCA) was synthesized. ► The GS–PTCA provided a selective interface for discrimination of AA, DA, UA and Trp.

Facile synthesis of new nano sorbent for magnetic solid-phase extraction by self assembling of bis-(2,4,4-trimethyl pentyl)-dithiophosphinic acid on Fe3O4@Ag core@shell nanoparticles: Characterization and application

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Elham Tahmasebi, Yadollah Yamini
A novel sorbent for magnetic solid-phase extraction by self-assembling of organosulfur compound, (bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid), onto the silver-coated Fe3O4 nanoparticles was introduced. Due to the formation of covalent bond of SAg, the new coating on the silver surface was very stable and showed high thermal stability (up to 320°C). The size, morphology, composition, and properties of the prepared nanoparticles have also been characterized and determined using scanning electron microscopy (SEM), energy-dispersive X-ray analyzer (EDX), dynamic light scattering (DLS), Fourier transform-infrared (FT-IR) spectroscopy, and thermal gravimetric analysis (TGA). Extraction efficiency of the new sorbent was investigated by extraction of five polycyclic aromatic hydrocarbons (PAHs) as model compounds. The optimum extraction conditions for PAHs were obtained as of extraction time, 20min; 50mg sorbent from 100mL of the sample solution, and elution with 100μL of 1-propanol under fierce vortex for 2min. Under the optimal conditions, the calibration curves were obtained in the range of 0.05–100μgL−1 (R 2 >0.9980) and the LODs (S/N=3) were obtained in the range of 0.02–0.10μgL−1. Relative standard deviations (RSDs) for intra- and inter-day precision were 2.6–4.2% and 3.6–8.3%, respectively. In addition, feasibility of the method was demonstrated with extraction and determination of PAHs from some real samples containing tap water, hookah water as well as soil samples with relative recovery of 82.4–109.0% and RSDs of 3.5–11.6%.

Graphical abstract

image

Graphical abstract Highlights

Self assembling of bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid on Fe3O4@Ag core@shell nanoparticles and application of it for solid phase extraction of PAHs.
► A novel sorbent for magnetic solid-phase extraction of PAHs was introduced. ► Silver was coated on Fe3O4 nanoparticles (MNPs) by reduction of AgNO3 with NaBH4. ► Bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid self-assembled on silver coated MNPs. ► Size, morphology, composition and properties of the nanoparticles were characterized. ► Extraction efficiency of the sorbent was investigated by extraction of five PAHs.

A comprehensive procedure based on gas chromatography–isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Xavier de la Torre, Cristiana Colamonici, Davide Curcio, Francesco Molaioni, Francesco Botrè
The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC–IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3‰ 13C delta units and between assay precision below 0.6‰ 13C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

Graphical abstract

image

Graphical abstract Highlights

► Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. ► Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. ► Routine analysis of steroids by GC/C/IRMS in sports drug testing.

RF-pulsed glow discharge time-of-flight mass spectrometry for glass analysis: Investigation of the ion source design

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Marcos Bouza, Beatriz Fernández, Cristina González-Gago, Nerea Bordel, Rosario Pereiro, Alfredo Sanz-Medel
Radiofrequency (RF) millisecond pulsed glow discharge (PGD) coupled to time-of-flight mass spectrometry (TOFMS) was investigated for direct elemental analysis of glass samples. Aiming at achieving highest elemental sensitivity, appropriate discrimination from polyatomics, and good crater shapes on glasses, a new Grimm-type GD chamber (termed from now “UNIOVI GD”, designed and constructed in our laboratory) was coupled to TOFMS, and the results compared with those obtained with the former GD design (here denominated as “GD.1”) of the initial RF-PGD-TOFMS prototype. The critical differences distinguishing the two GDs under scrutiny are the GD chamber thickness (15.5mm for the GD.1 and 7mm for the UNIOVI GD) and the “flow tube” which is inserted in the GD.1 and inexistent in UNIOVI GD. A pulse period of 4ms and a duty cycle of 50% were selected for the PGD studies. In order to characterizing the UNIOVI GD, the effect of RF-PGD experimental conditions (pressure and power) on signal shapes along the pulse was first investigated. Then, the analytical performance achieved was compared with results obtained using the GD.1 chamber. Results show that the UNIOVI GD source induced less thermal stress on the glass specimens. Consequently higher GD power can be applied to the UNIOVI GD (up to at least 130W), as compared to the GD.1 (maximum of 60W), without glass sample breakdown. Also, better crater shapes on samples were obtained using the UNIOVI GD. Moreover, the detection limits attained with the UNIOVI GD (in the range of μgg−1) were in most cases about one order of magnitude better for the analytes investigated (B, Na, Al, Si, Mn, Ni, Co, Cu, Zn, As, Sr, Ag, In, Sn, Sb, Ba, Pb and Bi), than those observed using the GD.1.

Graphical abstract

image

Graphical abstract Highlights

► A new GD chamber coupled to TOFMS was investigated for direct glass analysis. ► The effect of GD experimental conditions on signal shapes was investigated. ► The proposed GD induced less thermal stress on samples than previous GD designs. ► Better detection limits were found compared to those obtained with previous GDs.

Development of a liquid–chromatography tandem mass spectrometry and ultra-high-performance liquid chromatography high-resolution mass spectrometry method for the quantitative determination of zearalenone and its major metabolites in chicken and pig plasma

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
S. De Baere, A. Osselaere, M. Devreese, L. Vanhaecke, P. De Backer, S. Croubels
A sensitive and specific method for the quantitative determination of zearalenone (ZEN) and its major metabolites (α-zearalenol (α-ZEL), β-zearalenol (β-ZEL), α-zearalanol (α-ZAL), β-zearalanol (β-ZAL) and zearalanone (ZAN)) in animal plasma using liquid chromatography combined with heated electrospray ionization (h-ESI) tandem mass spectrometry (LC–MS/MS) and high-resolution Orbitrap® mass spectrometry ((U)HPLC–HR–MS) is presented. The sample preparation was straightforward, and consisted of a deproteinization step using acetonitrile. Chromatography was performed on a Hypersil Gold column (50mm×2.1mm i.d., dp: 1.9μm, run-time: 10min) using 0.01% acetic acid in water (A) and acetonitrile (B) as mobile phases. Both mass spectrometers were operated in the negative h-ESI mode. The method was in-house validated for all analytes: matrix-matched calibration graphs were prepared and good linearity (r ≥0.99) was achieved over the concentration range tested (0.2–200ngmL−1). Limits of quantification (LOQ) in plasma were between 0.2 and 5ngmL−1 for all compounds. Limits of detection in plasma ranged from 0.004 to 0.070ngmL−1. The results for the within-day and between-day precision, expressed as relative standard deviation (RSD), fell within the maximal RSD values (within-day precision: RSDmax =2(1–0.5logConc) x 2/3; between-day precision: RSDmax =2(1–0.5logConc)). The accuracy fell within −50% to +20% (concentrations <1ngmL−1), −30% to +10% (concentrations between 1 and 10ngmL−1) or −20% to +10% (concentrations >10ngmL−1) of the theoretical concentration. The method has been successfully used for the quantitative determination of ZEN in plasma samples from broiler chickens and pigs. α-ZEL and β-ZEL were the only metabolites that could be detected, but the concentrations were around the LOQ levels. The intact ZEN-glucuronide conjugate could be detected using the (U)HPLC–HR–MS instrument. A good correlation (r 2 =0.9979) was observed between the results for ZEN obtained with the LC–MS/MS and (U)HPLC–HR–MS instruments. The results prove the usefulness of the developed method for application in the field of toxicokinetic analysis and for exposure assessment of mycotoxins.

Graphical abstract

image

Graphical abstract Highlights

► Qualitative+quantitative analyses of zearalenone with LC–MS/MS and (U)HPLC–HR–MS. ► Development of a generic, rapid and cheap sample preparation procedure. ► Chromatograhy: baseline separation of metabolites with same precursor ion, run-time: 10min. ► Method validation: linearity, accuracy, precision, LOQ, LOD, specificity, recovery and matrix effects. ► Investigation of toxicokinetics of zearalenone in chickens.

Aromatic amines from polyurethane adhesives in food packaging: The challenge of identification and pattern recognition using Quadrupole-Time of Flight-Mass SpectrometryE

26 November 2012, 14:26:08
Publication year: 2012
Source:Analytica Chimica Acta, Volume 756
Davinson Pezo, Mauro Fedeli, Osvaldo Bosetti, Cristina Nerín
Toxic primary aromatic amines (PAAs) are reaction products from residual isocyanates in polyurethane adhesives. The maximum migration level of the total sum of PAAs is 10ngg−1 of food. This paper reports on a method for quantification of 18 PAAs by UHPLC–MS/MS that was optimised and applied to a series of industrial laminates prepared from polyurethane adhesives. Non-intentionally added substances (NIAS), impurities and other migrants were identified by Q-TOF/MSE. A comparison of the quantitative values obtained by the colorimetric method using NEDA and by UHPLC–MS/MS confirmed that the first method can overestimate the quantification of PAAs. This could be attributed to the impurities and other NIAS present in the plastic laminate. Values of R 2 in the analytical characteristics of UHPLC–MS/MS were obtained, the best value being 0.9964 and the most unfavourable 0.7626. The detection limit (LOD) and the quantification limit (LOQ) were 2pgg−1 and 7pgg−1, respectively. The stability of the PAAs over time in the acidic simulant in contact with the plastic laminate is also reported.

Graphical abstract

image

Graphical abstract Highlights

► 18 primary aromatic amines from adhesives in multilayer plastics are analysed by UPLC–LC–TQ. ► Non intentionally added substances are identified in the multilayer materials by UPLC–Q-TOF–MS. ► Quantitative values of PAAs are compared to those obtained by colorimetric method using NEDA. ► Overestimation of NEDA procedure is demonstrated. ► Pattern recognition of the impurities and NIAS from adhesives in the multilayers are achieved.

Bruker Make Available CD and Datafiles for GC-MS EPA Methods


Bruker CAM have released a new GC-MS Environmental Manual Methods available as a complimentary CD and datafile download via their website. The manual illustrates how the Bruker SCION™ SQ is ideal for EPA methods and the link to the methodology enables a quick download of the datafiles directly to your SCION SQ, to enable immediate running of EPA methods.
 
The Environmental Protection Agency (EPA) and other government bodies are developing evermore stringent screening policies to monitor the level and effects of pesticides and other contaminants in the environment. In line with this, the need for fast and robust quantitative analysis of thousands of samples in complex matrices is growing. Bruker’s GC-MS Environmental Manual Methods and CD advises on how best to use the SCION SQ to optimize performance, while fully complying with the required EPA methods. The methods covered in the manual are EPA Method 524.3 ‘Measurement of purgeable organic compounds in water by capillary column gas chromatography-mass spectrometry’, EPA Method 525.2 ‘Determination of organic compounds in drinking water by liquid-solid extraction and capillary column gas chromatography-mass spectrometry’, and EPA Method 8270D – ‘ Semi volatile organic compounds by gas chromatography-mass spectrometry’. Bruker have structured the manual around each method, making it easy to identify the section you need. Each method discusses scope and application, method summary, equipment parameters, reagents and standards, instrument set-up, expected analytical results, and trouble shooting.

With a lens-free ion path, active focussing q0 and extended dynamic range detector, Bruker’s SCION SQ is fast becoming the instrument of choice for environmental analytics, as it sets new industry standards for gas chromatography single quadrupole mass detection. Employing innovative new design features, like the axial flow source which ensures greater inertness and increased robustness, 90o curved qo to eliminate neutral noise, and fast scanning quadrupole (14,000 amu/sec) for fast SIM/Scan acquisition the SCION SQ is the perfect choice for the environmental laboratory. An upper mass limit of m/z1200 makes the SCION SQ is capable of handling almost any GC application, hence its suitability for EPA methods outlined on the CD. Designed to be user-friendly and requiring only simple maintenance, the SCION SQ is the first choice for any GC-MS application.

The SCION SQ method and data files for EPA Method 524.3, 525.2 and 8270D can be found in PDF format at www.scionhasarrived.com or on request as a CD.

Tuesday, 20 November 2012

Just Published: Talanta


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Talanta
Selected papers from the latest issue:

Selective determination of gold(III) ion using CuO microsheets as a solid phase adsorbent prior to ICP-OES measurements

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Mohammed M. Rahman, Sher Bahadar Khan, Hadi M. Marwani, Abdullah M. Asiri, Khalid A. Alamry, Abdulrahman O. Al-Youbi
We have prepared calcined CuO microsheets (MSs) by a wet-chemical process using reducing agents in alkaline medium and characterized by UV/vis., Fourier transform infrared (FT-IR) spectroscopy, powder X-ray diffraction (XRD), and field-emission scanning electron microscopy (FESEM) etc. The detailed structural, compositional, and optical characterizations of the MSs were evaluated by XRD pattern, FT-IR, X-ray photoelectron spectroscopy (XPS), and UV-vis spectroscopy, respectively which confirmed that the obtained MSs are well-crystalline CuO and possessed good optical properties. The CuO MSs morphology was investigated by FESEM, which confirmed that the calcined nanomaterials were sheet-shaped and growth in large-quantity. Here, the efficiency of the CuO MS was applied for a selective adsorption of gold(III) ion prior to its detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The selectivity of CuO MSs towards various metal ions, including Au(III), Cd(II), Co(II), Cr(III), Fe(III), Pd(II), and Zn(II) was analyzed. Based on the adsorption isotherm study, it was confirmed that the selectivity of MSs phase was the most towards Au(III) ion. The static adsorption capacity for Au(III) was calculated to be 57.0mgg−1. From Langmuir adsorption isotherm, it was confirm that the adsorption process was mainly monolayer-adsorption onto a surface containing a finite number of adsorption sites.

Highlights

► Selective detection of Gold(III) Ion based on un-doped CuO Microsheets. ► CuO Microsheets used as a Selective Solid Phase Adsorbent. ► The static adsorption capacity for Au(III) was calculated to be 57.0mgg−1. ► Adsorption process was mainly monolayer based onto a surface containing a finite number of adsorption sites

Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Dazhong Shen, Yaolong Li, Zhenli Zhang, Ping Zhang, Qi Kang
The impedance of a capacitively coupled contactless conductivity detector (C4D) in capillary electrophoresis (CE) was measured by an impedance analysis method. The influence of solution conductivity and capillary dimension on impedance parameters was investigated. Under the experimental conditions used, 86–99.9% of the total impedance of a C4D is composed by its imaginary part from the capillary wall capacitor. With increasing inner diameter of capillary and solution conductivity in detection zone, the wall capacitance increases, which results in the increase in the response signal of C4D. But the wall capacitance is only 0.5–12% of the predicted value according to a cylinder capacitor model. As the change in solution resistance is detected in a resonant C4D (RC4D), the sensitivity of contactless conductivity detection in CE is improved. The application of an end-to-end differential RC4D (DRC4D) system in CE was demonstrated in the determination of ten amino acids. The running buffer consisted of 2M acetic acid and 0.1% hydroxyethylcellulose (pH2.1). The limit of detection for amino acids is in the range of 0.1–0.4μM. Under our experimental conditions, the sensitivity of DRC4D enhances by a factor of 15–29as compared with C4D.

Highlights

► The sensitivity of contactless conductivity detector in capillary electrophoresis is improved. ► The dependence of wall capacitance on solution conductivity and capillary dimension is reported. ► Capillary electrophoresis with end-to-end differential detection is reported. ► The responses of different contactless conductivity detectors are compared.

Evaluation of the performance of the determination of anions in the water soluble fraction of atmospheric aerosols

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Alejandro Arias, Ricardo J.N. Bettencourt da Silva, M.Filomena G.F.C. Camões, Cristina M.R.R. Oliveira
Abstract The knowledge of the mass of particulate matter in air, its chemical composition and emission sources is of relevance for taking decisions concerning air quality management in urban areas. The interpretation of these data is a function of the quality of the measurement results expressed by their uncertainties. This study aimed at developing models of the performance of the determination of anions in the water-soluble fraction of atmospheric aerosols, capable of determining, separately, the contribution of aerosols sampling, extraction of water-soluble fraction of atmospheric aerosols and quantification, by ion chromatography, of anions in the extract. The sampling procedure was assessed from the dispersion of results of duplicate parallel sampling after subtracting the analytical component of this dispersion. These models are used to evaluate the adequacy of the measurement procedure for the determination of urban aerosol composition and to support strategies for reducing measurement uncertainty or cost of analysis. The method performance was studied for the following ranges considering extract dilution up to five times: 0.23–8µgm−3 for chloride and nitrate, and 0.093–3.25µgm−3 for sulphate. Measurements are fit for the analysis of urban aerosols since the relative expanded measurement uncertainty is smaller than a maximum value of 40%. The percentage contribution of the uncertainty components varies with the analyte and its mass concentration, the major components being 24–93% for the extraction, 43–59% for sampling, 0.2–28% for the interpolation of the sample signal in the calibration curve and 4–8% for air volume measurement. The typical composition of analysed air is: (1.12±0.26) µgm−3, (1.02±0.30) µgm−3 and (0.76±0.22) µgm−3 of chloride, nitrate and sulphate in the water soluble fraction of aerosol respectively, for a confidence level of approximately 95% considering a coverage factor of 2.

Highlights

► Performance of the characterisation of atmospheric aerosols is assessed. ► Differential approach of the evaluation of the measurement uncertainty is used. ► Sampling and extraction uncertainty are estimated separately. ► Strategies for measurement uncertainty and cost of analysis reduction are proposed. ► Measurements are fit for the analysis of aerosols since present adequate uncertainty.

Comparison of On-Line Detectors for Field Flow Fractionation Analysis of Nanomaterials

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
A.J. Bednar, A.R. Poda, D.M. Mitrano, A.J. Kennedy, E.P. Gray, J.F. Ranville, C.A. Hayes, F.H. Crocker, Steevens
Characterization of nanomaterials must include analysis of both size and chemical composition. Many analytical techniques, such as dynamic light scattering (DLS), are capable of measuring the size of suspended nanometer-sized particles, yet provide no information on the composition of the particle. While Field Flow Fractionation (FFF) is a powerful nanoparticle sizing technique, common detectors used in conjunction with the size separation, including UV, light-scattering, and fluorescence spectroscopy, do not provide the needed particle compositional information. Further, these detectors do not respond directly to the mass concentration of nanoparticles. The present work describes the advantages achieved when interfacing sensitive and elemental specific detectors, such as Inductively Coupled Plasma Atomic Emission Spectroscopy and Mass Spectrometry, to FFF separation analysis to provide high resolution nanoparticle sizing and compositional analysis at the μg/L concentration level, a detection at least 10 to 100 fold lower than DLS or FFF-UV techniques. The full benefits are only achieved by utilization of all detector capabilities, such as dynamic reaction cell (DRC) ICP-MS. Such low-level detection and characterization capability is critical to nanomaterial investigations at biologically and environmentally relevant concentrations. The techniques have been modified and applied to characterization of all 4 elemental constituents of Cadmium Selenide Zinc Sulfide core-shell quantum dots, and silver nanoparticles with gold seed cores. Additionally, sulfide coatings on silver nanoparticles can be detected as a potential means to determine environmental aging of nanoparticles.

Highlights

► Simultaneous multi-element detection of nanomaterials. ► Quantum Dot 4 element detection. ► Environmentally relevant concentrations of nanomaterials. ► Fate and transformation. ► Coating formation, and transformation, and detection.

Colorimetric determination of thiram based on formation of gold nanoparticles using ascorbic acid

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
S. Rastegarzadeh, Sh. Abdali
A novel optical method for the determination of thiram has been developed using surface plasmon resonance peak of gold nanoparticles (AuNPs). The stable and dispersed AuNPs were directly synthesized by reduction of HAuCl4 with ascorbic acid in micellar media according to a simple approach. The presence of thiram during formation of AuNPs results in the decrease of the intensity of plasmon resonance peak. The variation in the plasmon absorbance allows the colorimetric determination of thiram. The effect of different variables such as pH, ascorbic acid and CTAB concentrations was studied and optimized. The proposed method is capable of determining thiram over a range of 2.0×10−7−1.0×10−5 molL−1 with a limit of detection 1.7×10−7 molL−1. The relative standard deviation of the method was <3.7%. The method was successfully applied to the determination of thiram in water and plant seed samples.

Highlights

► A novel optical method for sensitive spectrophotometric determination of thiram. ► First time ascorbic acid was used as reducer in detection method by AuNPs plasmon. ► The proposed method has a simple, fast and eco-friendly procedure. ► In contrast with citrate method, the AuNPs were formed in situe. ► The LOD is better than other methods based on spectrophotometric detection.

Rapid Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Zebrafish Eleutheroembryos as a Model for the Evaluation of PAH Bioconcentration

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
S. El-Amrani, J. Sanz-Landaluze, J. Guinea, C. Cámara
A simple and fast approach for a novel bioaccumulation test by exposing zebrafish eleutheroembryos to fluorene and anthracene (PAHs) at two concentrations levels below 1% of their LC50 is presented. This alternative protocol sets an uptake period of 48 hours at 26°C for bioconcentration of the compounds tested and an additional 24 hours for depuration. Two different methods to estimate bioconcentration factors (BCFs) of PAHs were used. The first consists in the ratio between concentrations of the tested compounds in the zebrafish eleutheroembryos and the exposure media when a steady state during exposure is reached (BCFss). The second employs the concentration–time profile with the use of a least-square fit to a non-linear model (BCFk). A steady state (ss) was reached after 12 hours and 22 hours for fluorene and anthracene exposure, respectively. Uptake and depuration rate constants obtained were similar for the two exposure levels tested, hence toxicokinetic rate constants appeared to be independent of the exposure level. Bioconcentration factors of 1164 and 817 for fluorene exposure at 0.99ngmL−1 and 7.9ngmL−1 and of 2089 and 2344 for anthracene at 0.63ngmL−1 and 6.1ngmL−1 were assessed. The good agreement of the obtained results with those reported in the literature proves the feasibility of the proposed method for estimation of both toxicokinetic parameters and bioconcentration factors. Furthermore, this protocol, has potential to be an alternative to the OECD (Organisation for Economic Cooperation and Development) 305 method, considerably reducing time and associated costs of the test suggested by European legislation.

Highlights

► Zebrafish eleutheroembryos is proven as a non-animal model to test bioaccumulation. ► For both PAHs tested, bioaccumulation factors obtained are in the medium-high range. ► Analytical methodology developed uses small sample amounts and low reagents consumption. ► Cost of proposed test is much lower than the official ones and much faster.

Electrodeposition of poly(3,4-ethylenedioxythiophene) on a stainless steel wire for solid phase microextraction and GC determination of some esters with high boiling points

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Yuyu Ma, Faqiong Zhao
In this work, 3,4-ethylenedioxythiophene (EDOT) emulsion is prepared by ultrasonication agitation and poly(3,4-ethylenedioxythiophene) (PEDOT) coating is fabricated on a stainless steel wire by electrochemical method from a 0.10M sodium dodecyl benzenesulfonate aqueous solution containing EDOT. The coating is characterized by scanning electron microscopy and Fourier transform infrared spectrophotometry, and it presents cauliflower-like structure. When the resulted PEDOT/steel fiber is used for the headspace solid phase-microextraction of some esters (i.e. methyl anthranilate, dimethyl phthalate, ethyl-o-aminobenzoate, methyl laurate, diethyl phthalate) and their GC detection, the limits of detection (LOD) are ca. 7.8–31ngL−1(S/N=3) and the linear ranges are 0.25–800μgL−1. The fiber shows high thermal stability (up to 320°C), good reproducibility and long lifetime (more than 183 times). It also has good chemical stability. After it is immersed in acid, alkali and dichloromethane for 4 hours its extraction efficiency remains almost unchanged. Besides esters the fiber also exhibits high extraction efficiency for alcohols and aromatic compounds.

Highlights

► A poly(3,4-ethylenedioxythiophene) (PEDOT) coating is prepared by electrochemical method. ► It shows cauliflower-like structure and has large surface area and high mass-transport rate. ► When it is used for SPME, it presents high stability and extraction efficiency for esters. ► This is a new way to make use of different monomers to prepare SPME fibers.

A novel composite film derived from cysteic acid and PDDA-functionalized graphene: Enhanced sensing material for electrochemical determination of metronidazole

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Weilu Liu, Jianfu Zhang, Cong Li, Liu Tang, Zhiquan Zhang, Ming Yang
A novel composite film derived from cysteic acid and poly(diallydimethylammonium chloride)-functionalized graphene (PDDA-GN) was employed as an enhanced electrode material for ultrasensitive determination of metronidazole. The cysteic acid/PDDA-GN composite film was prepared by the electrochemical grafting of cysteic acid onto the PDDA-GN coated glassy carbon electrode (GCE). The cyclic voltammetry investigations reveal that the peak current of metronidazole reduction at the cysteic acid/PDDA-GN/GCE was remarkably enhanced compared to the bare GCE, the cysteic acid/GCE and the PDDA-GN/GCE. This result implies the synergistic electrocatalytic effect of cysteic acid and PDDA-GN. The fabricated sensor shows linear response to metronidazole in the ranges of 10nM - 1µM and 70µM - 800µM, with a detection limit of 2.3nM (S/N=3). The heterogeneous electron transfer rate constant and the diffusion coefficient of metronidazole were further evaluated by rotating disk electrode experiments. Moreover, we applied the present method to the determination of metronidazole in urine and lake water with satisfactory results.

Highlights

► Facile microwave-heating procedure for preparing PDDA-functionalized graphene. ► Cysteic acid/PDDA-functionalized graphene composite film as a new electrode material. ► High electrocatalytic activity for metronidazole reduction. ► Wide linear range, low detection limit for the determination of metronidazole. ► Application in practical samples with satisfactory results.

Quenching effect on gold nano-patterned cardiac troponin I chip by total internal reflection fluorescence microscopy

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Seungah Lee, Seong Ho Kang
Total internal reflection fluorescence microscopy (TIRFM) was investigated for enhanced detection sensitivity of cardiac troponin I (cTnI) on a gold nano-patterned protein chip. A 4×5 nanoarray patterning of a gold chip based on a single-molecule sandwich immunoassay was prepared with a spot diameter of 500nm on glass substrates formed via electron-beam nanolithography. Quantitative trace analysis was possible as a function of increasing total internal reflection fluorescence intensity in the range of 84aM - 350pM at prism-type and 35aM - 350pM at objective-type TIRFM, respectively. Although using same gold nano-patterned cTnI chips, however, the objective-type TIRFM showed enhanced detection sensitivities 2.4 times better than the prism-type due to weaker gold quenching. This result is also about 7,000 times lower in the detection limit compared with those obtained by conventional commercial sandwich enzyme-linked immunosorbent assay techniques.

Highlights

► Quenching effects on gold nano-patterned chips with a spot diameter of 500 nm. ► Quantitative analysis of cTnI using the prism- and objective-type TIRFM. ► Stronger quenching efficiency in the prism- than in the objective-type TIRFM. ► Improved detection sensitivity of cTnI at the aM concentration level.

On-line solid phase extraction using organic-inorganic hybrid monolithic columns for the determination of trace β-lactam antibiotics in milk and water samples

20 November 2012, 09:27:36
Publication year: 2012
Source:Talanta
Yun Zhang, Haiyan Liu, Xiaoyan Zhang, Huan Lei, Bai, Yang
A rapid and simple method with on­line solid phase extraction (SPE) has been developed for the simultaneous determination of beta-lactam antibiotics (BLAs) (amoxicillin, cephradine, and cefazolin sodium) in aquatic environment and milk. The epoxy-based organic-inorganic hybrid monolithic column was used as SPE sorbent to simultaneously monitor three analytes. The morphology of monolithic column and pressure drop across the columns were characterized. Excellent permeability and high selectivity was obtained. The linear range of the standard curve was from 2.0 to 500ng/mL (r2≥ 0.999). Precision for inter- and intra-day assay showed acceptable results for quantitative assay with relative standard deviation (RSD) less than 11%. The accuracy and recovery were found to be within the range of 93–103% and 83–105%. The results indicated that the prepared monolithic column could provide excellent reproducibility and implied that the prepared monolith was feasible to be used as an on-line SPE sorbent material.

Highlights

► A rapid and simple online solid phase extraction (SPE) were developed. ► The novel epoxy-based column was used as SPE sorbent to monitor β-lactam. ► It has a safe, efficient, easy to operate, easy to realize the advantages of automation. ► Validation was performed at spike concentrations of 10, 50 and 500 ng mL−1. ► Accuracy, precision, matrix effect, linearity, LOD and LOQ were assessed.

Protecting Light Sensitive Samples From Degradation

To protect light sensitive samples - Porvair Sciences offers a selection of high quality, black microplates and seals that eliminate sample degradation, even over long storage periods. 

Manufactured from ultra-pure grade polypropylene, Porvair black microplates are resistant to a wide range of solvents and have near zero leachates ensuring long-term sample integrity. The black plates are supplied RNase / DNase free meaning they can be used with even the most sensitive biological samples.  Available in a choice of 96-well formats - Porvair black plates are precisely manufactured to applicable ANSI / SLAS dimensions* ensuring complete compatibility with almost all readers and automated equipment.   

To prevent evaporation, hydration of DMSO solutions and to completely eliminate light from samples - Porvair Sciences additionally offers a choice of black, light absorbing sealing films that may be applied to the top of the black plates.

For further information on black microplates and sealing films please contact PorvairSciences on telephone +44-1372-824290 or email int.sales@porvair-sciences.com. 

Monday, 19 November 2012

Just Published: Biosensors & Bioelectronics


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Evaluation of the actin cytoskeleton state using an antibody-functionalized nanoneedle and an AFM

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Yaron R. Silberberg, Shingo Mieda, Yosuke Amemiya, Toshiya Sato, Takanori Kihara, Noriyuki Nakamura, Kyoko Fukazawa, Kazuhiko Ishihara, Jun Miyake, Chikashi Nakamura
A cell diagnosis technique was developed, which uses an Atomic Force Microscope (AFM) and an ultra-thin AFM probe sharpened to a diameter of 200nm (nanoneedle). Due to the high aspect ratio of the nanoneedle, it was successfully inserted into a living cell without affecting its viability. Furthermore, by functionalizing the nanoneedle with specific antibodies and measuring the unbinding forces (‘fishing forces’) during evacuation of the nanoneedle from the cell, it was possible to measure specific mechanical interactions between the antibody-functionalized nanoneedle and the intracellular contents of the cell. In this study, an anti-actin-antibody-functionalized nanoneedle was used to evaluate the actin cytoskeleton state in living cells. To examine the effect of cytoskeleton condition on the measured fishing forces, the cytoskeleton-disrupting drugs cytochalasin D (cytD) and Y-27632 were used, showing a marked decrease in the measured fishing forces following incubation with either of the drugs. Furthermore, the technique was used to measure the time course changes in a single cell during incubation with cytD, showing a gradual time-dependent decrease in fishing forces. Even minute doses of the drugs, the effects of which were hardly evident by optical and fluorescence methods, could be clearly detected by the measurement of nanoneedle–protein fishing forces, pointing to the high sensitivity of this detection method. This technique may prove beneficial for the evaluation of cytoskeleton conditions in health and disease, and for the selection of specific cells according to their intracellular protein contents, without the need for introduction of marker proteins into the cell.

Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
J.P. Golden, J. Verbarg, P.B. Howell, L.C. Shriver-Lake, F.S. Ligler
A spinning magnetic trap (MagTrap) for automated sample processing was integrated with a microflow cytometer capable of simultaneously detecting multiple targets to provide an automated sample-to-answer diagnosis in 40min. After target capture on fluorescently coded magnetic microspheres, the magnetic trap automatically concentrated the fluorescently coded microspheres, separated the captured target from the sample matrix, and exposed the bound target sequentially to biotinylated tracer molecules and streptavidin-labeled phycoerythrin. The concentrated microspheres were then hydrodynamically focused in a microflow cytometer capable of 4-color analysis (two wavelengths for microsphere identification, one for light scatter to discriminate single microspheres and one for phycoerythrin bound to the target). A three-fold decrease in sample preparation time and an improved detection limit, independent of target preconcentration, was demonstrated for detection of Escherichia coli 0157:H7 using the MagTrap as compared to manual processing. Simultaneous analysis of positive and negative controls, along with the assay reagents specific for the target, was used to obtain dose–response curves, demonstrating the potential for quantification of pathogen load in buffer and serum.

Highlights

► This paper describes the first integration of the spinning magnetic trap for automated sample preparation with an analytical device, the NRL microflow cytometer. ► We have also included improvements in the microflow cytometer not described elsewhere. ► The data indicate that the combined components increase the sensitivity and reproducibility of the assays, simultaneously reducing the assay time significantly.

Detection of vimentin serine phosphorylation by multicolor Quenchbodies

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Hee-Jin Jeong, Yuki Ohmuro-Matsuyama, Hiroyuki Ohashi, Fuyuki Ohsawa, Yoshiro Tatsu, Masaki Inagaki, Hiroshi Ueda
Protein phosphorylation is a key event in intracellular signal transduction, and fluorescent biosensor for the specific phosphorylation event in a target protein is considered highly useful as a tool of cellular biology and drug screening. Vimentin, the most abundant intermediate filament protein, is phosphorylated at its specific serine (Ser) residues in a cell cycle dependent manner. Its structural and functional characteristics are modified by the phosphorylation, which affects biological properties of the cell. Here we present the detection of the vimentin Ser71 phosphorylation (PS71) and the vimentin Ser82 phosphorylation (PS82) using a novel fluorescent biosensor Quenchbody, which works on the principle of antigen-dependent removal of a quenching effect by intrinsic tryptophan residues on a carboxytetramethylrhodamine (TAMRA) dye incorporated at the N-terminal region of single chain antibody variable region. First, we found that rhodamine 6G (R6G)-labeled Quenchbody shows superior response than TAMRA-labeled one. Next, we made several Quenchbodies to detect PS71 and PS82. After optimization of reaction conditions, the fluorescence intensity of VH-VL type PS71 Quenchbody labeled with R6G at two positions was increased to 4.0-fold in an antigen dependent manner. Furthermore, the fluorescence intensity of doubly R6G-labeled VL-VH type PS82 Quenchbody was increased to 6.7-fold immediately after adding antigen peptide, also suggesting deeper quenching due to H-dimer formation between the dyes. Due to its simplicity, the Quenchbody-based phosphorylation biosensors will be widely applicable to in vitro diagnostics, drug screening and imaging in a rapid, simple and high-sensitive manner.

Nanochannels for diagnostic of thrombin-related diseases in human blood

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Alfredo de la Escosura-Muñiz, Wilanee Chunglok, Werasak Surareungchai, Arben Merkoçi
A high sensitive voltammetric method for rapid determination of thrombin spiked in whole blood by taking advantage of both aptamer-based recognition and the use of a nanoporous membrane has been developed. The nanoporous membrane not only acts as platform for the thrombin recognition but also as filter of the micrometric components such as white and red blood cells, consequently minimizing matrix effects. The protocol involves a sandwich format in the inner walls (200nm diameter) of an anodized alumina oxide filter membrane (AAO). The analytical signal, by DPV oxidation of [Fe(CN)6]4−, is based on the blockage in the pores which affects the diffusion of [Fe(CN)6]4− to the screen-printed carbon electrotransducer (SPCEs) modified with the membrane. By labeling the anti-thrombin IgG with AuNPs followed by silver enhancement a greater passive signal enhancement in comparison to the membrane blockage has been observed. The contribution of both electrostatic/steric effects in this blockage due to the subsequent formation of the aptamer-thrombin complex and the final sandwich assay is investigated. The efficiency of the system is also monitored by microscopic techniques. The resulted biosensing system allows detecting thrombin spiked in whole blood at very low levels (LOD 1.8ngmL−1) which are within the range of clinical interest for the diagnostic of coagulation abnormalities as well as pulmonary metastasis.

2D crystalline protein layers as immobilization matrices for the development of DNA microarrays

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Sylvia R. Scheicher, Birgit Kainz, Stefan Köstler, Norbert Reitinger, Nicole Steiner, Harald Ditlbacher, Alfred Leitner, Dietmar Pum, Uwe B. Sleytr, Volker Ribitsch
There is a growing demand for functional layers for the immobilization of (bio)molecules on different kinds of substrates in the field of biosensors, microarrays, and lab-on-a-chip development. These functional coatings should have the ability to specifically bind (bio)molecules with a high binding efficiency, while showing low unspecific binding during the following assay. In this paper we present rSbpA surface layer proteins (S-layer proteins) as a versatile immobilization layer for the development of DNA microarrays. S-layer proteins show the ability to reassemble into two-dimensional arrays on solid surfaces and their functional groups, such as carboxylic groups, are repeated with the periodicity of the lattice, allowing for immobilization of other (bio)molecules. Different fluorescently labeled amino functionalized DNA oligomers were covalently linked to the S-layer matrices to allow the characterization of DNA binding on S-layers. Hybridization and dissociation of DNA-oligomers were studied on S-layer coated slides, revealing low levels of unspecific adsorption of DNA on S-layer based immobilization matrices. In the following the principle was transferred to a DNA microarray design showing successful spotting and hybridization on whole microarray slides. Besides common laser scanning for fluorescence detection, S-layer based microarrays were evaluated with a compact, low cost platform for direct fluorescence imaging based on surface plasmon enhanced fluorescence excitation. It could be shown that S-layer protein layers are promising as immobilization matrices for the development of biosensors and microarrays.

Label-free, needle-type biosensor for continuous glucose monitoring based on competitive binding

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Sung-Ho Paek, Il-Hoon Cho, Dong-Hyung Kim, Jin-Woo Jeon, Guei-Sam Lim, Se-Hwan Paek
With the goal of developing a method for the continuous monitoring of blood glucose, an implantable sensor was developed by placing an optical fiber probe within the internal hollow space of a syringe needle. A glucose binder, concanavalin A (Con A), was immobilized on the probe tip and a protein (e.g., bovine serum albumin) chemically coupled with a sugar ligand (e.g., mannose) was loaded as a solution inside of the needle, which were then closed using a semi-permeable membrane. Upon immersion in the glucose sample, small molecules were able to freely pass through the membrane and compete with the ligand conjugate for Con A binding. This changed the molecular layer thickness on the probe surfaces depending on the glucose concentration, which shifted the wavelength of the guided light along the fiber. Such interference in the wavelength pattern was measured using a commercial sensor system, Octet, without employing a label. Using this analytical approach, two major steps controlling the performance of glucose detection were overcome: permeation of glucose (optimum with 50nm-porous polycarbonate membrane under the experimental conditioned used) and molecular diffusion of the ligand conjugate within the sensor compartment (19 gauge-needle, offering minimal demensions for the probe). Under optimal conditions, the sensor was able to monitor glucose fluctuations, even in serum medium, with a response time of less than 15min in a range 10–500mg/dL. This, however, could be further shortened down to about 5min in principle by miniaturizing the sensor dimensions.

Flexible, layered biofuel cells

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Takeo Miyake, Keigo Haneda, Syuhei Yoshino, Matsuhiko Nishizawa
Similar to conventional electrolyte batteries, biofuel cells often need to be stacked in order to boost their single cell voltage (<1V) up to a practical level. Here, we report a laminated stack of biofuel cells that is composed of bioanode fabrics for fructose oxidation, hydrogel sheets containing electrolyte and fuel (fructose), and O2-diffusion biocathode fabrics. The anode and cathode fabrics were prepared by modifying fructose dehydrogenase and bilirubin oxidase, respectively, on carbon nanotubes-decorated carbon fiber fabrics. The total thickness of the single set of anode/gel/cathode sheets is just 1.1mm. The laminated triple-layer stack produces an open-circuit voltage of 2.09V, which is a 2.8-fold increase over that of a single set cell (0.74V). The present layered cell (5mm×5mm) produces a maximum power of 0.64mW at 1.21V, a level that is sufficient to drive light-emitting diodes.

Graphical abstract

image

Graphical abstract


Impedance spectroscopy with field-effect transistor arrays for the analysis of anti-cancer drug action on individual cells

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
A. Susloparova, D. Koppenhöfer, X.T. Vu, M. Weil, S. Ingebrandt
In this study, impedance spectroscopy measurements of silicon-based open-gate field-effect transistor (FET) devices were utilized to study the adhesion status of cancer cells at a single cell level. We developed a trans-impedance amplifier circuit for the FETs with a higher bandwidth compared to a previously described system. The new system was characterized with a fast lock-in amplifier, which enabled measuring of impedance spectra up to 50MHz. We studied cellular activities, including cell adhesion and anti-cancer drug induced apoptosis of human embryonic kidney (HEK293) and human lung adenocarcinoma epithelial (H441) cells. A well-known chemotherapeutic drug, topotecan hydrochloride, was used to investigate the effect of this drug to tumor cells cultured on the FET devices. The presence of the drug resulted in a 20% change in the amplitude of the impedance spectra at 200kHz as a result of the induced apoptosis process. Real-time impedance measurements were performed inside an incubator at a constant frequency. The experimental results can be interpreted with an equivalent electronic circuit to resolve the influence of the system parameters. The developed method could be applied for the analysis of the specificity and efficacy of novel anti-cancer drugs in cancer therapy research on a single cell level in parallelized measurements.

Bismuth nanoparticles for phenolic compounds biosensing application

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Carmen C. Mayorga-Martinez, Miquel Cadevall, Maria Guix, Josep Ros, Arben Merkoçi
The rapid determination of trace phenolic compounds is of great importance for evaluating the total toxicity of contaminated water samples. Nowadays, electrochemical tyrosinase (Tyr) based biosensors constitute a promising technology for the in situ monitoring of phenolic compounds because of their advantages such as high selectivity, low production cost, promising response speed, potential for miniaturization, simple instrumentation and easy automatization. A mediator-free amperometric biosensor for phenolic compounds detection based on the combination of bismuth nanoparticles (BiNPs) and Tyr for phenol detections will be hereby reported. This is achieved through the integration of BiNPs/Tyr onto the working electrode of a screen printed electrode (SPE) by using glutaraldehyde as a cross-linking agent. BiNPs/Tyr biosensor is evaluated by amperometric measurements at –200mV DC and a linear range of up to 71μM and 100μM and a correlation coefficient of 0.995 and 0.996 for phenol and catechol, respectively. The very low DC working potential ensures the avoidance of interferences making this biosensor an advantageous device for real sample applications. In addition, the response mechanism including the effect of BiNPs based on electrochemical studies and optical characterizations will be also discussed. The obtained results may open the way to many other BiNPs applications in the biosensing field.

Continuous labeling of circulating tumor cells with microbeads using a vortex micromixer for highly selective isolation

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Ming Xian Lin, Kyung-A Hyun, Hui-Sung Moon, Tae Seok Sim, Jeong-Gun Lee, Jae Chan Park, Soo Suk Lee, Hyo-Il Jung
Circulating tumor cells (CTCs) are identified in transit within the blood stream of cancer patients and have been proven to be a main cause of metastatic disease. Current approaches for the size-based isolation of CTCs have encountered technical challenges as some of the CTCs have a size similar to that of leukocytes and therefore CTCs are often lost in the process. Here, we propose a novel strategy where most of the CTCs are coated by a large number of microbeads to amplify their size to enable complete discrimination from leukocytes. In addition, all of the microbead labeling processes are carried out in a continuous manner to prevent any loss of CTCs during the isolation process. Thus, a microfluidic mixer was employed to facilitate the efficient and selective labeling of CTCs from peripheral blood samples. By generating secondary vortex flows called Taylor–Gortler vortices perpendicular to the main flow direction in our microfluidic device, CTCs were continuously and successfully coated with anti-epithelial cell adhesion molecule-conjugated beads. After the continuous labeling, the enlarged CTCs were perfectly trapped in a micro-filter whereas all of the leukocytes escaped.

Long-term three-dimensional cell culture and anticancer drug activity evaluation in a microfluidic chip

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Karina Ziółkowska, Agnieszka Stelmachowska, Radosław Kwapiszewski, Michał Chudy, Artur Dybko, Zbigniew Brzózka
In this work, we present a microfluidic array of microwells for long-term tumor spheroid cultivation and anticancer drug activity evaluation. The three-dimensional microfluidic system was obtained by double casting of poly(dimethylsiloxane). Spheroids of HT-29 human carcinoma cells were cultured in the microsystem for four weeks. After two weeks of the culture growth slowdown and stop were observed and high cell viability was determined within next two weeks. The characteristics of a homeostasis-like state were achieved. A cytostatic drug (5-fluorouracil) was introduced into the microsystem with different frequency (every day or every second day) and different concentrations. The geometry and construction of the microsystem enables flushing away of unaggregated (including dead) cells while viable spheroids remain inside microwells and decreasing spheroid diameter can be observed and measured as an indicator of decreasing cell viability. The results have shown differences in response of spheroids to different concentrations of 5-fluorouracil. It was also observed, that higher frequency of drug dosing resulted in more rapid spheroid diameter decrease. The presented microfluidic system is a solution for cell-based studies in an in vivo-like microfluidic environment. Moreover, observation of decreasing spheroid dimensions is a low-cost, label-free and easy-to-conduct mean of a quantitative determination of a 3D cellular model response to a applied drug. It is suitable for long-term observation of spheroid response, in a contrary to other viability assays requiring termination of a culture.

Construction of a controllable Förster resonance energy transfer system based on G-quadruplex for DNA sensing

19 November 2012, 09:29:31Go to full article
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
Qiaoli Yue, Tongfei Shen, Changna Wang, Lei Wang, Haibo Li, Shuling Xu, Huaisheng Wang, Jifeng Liu
Conjugations of oligonucleotides, chromophores, and gold nanoparticles (GNPs) can be used for energy transfer assays to detect DNA. Herein, a homogenous Förster resonance energy transfer (FRET) system employing two-step modification of oligonucleotide on GNPs was reported. The distance between the donor (fluorescein attached onto DNA) and the acceptor (GNPs) was controlled by using the G-rich DNA. In the presence of porphyrin or berberine, which can act as ligands of G-quadruplexes, the G-rich DNA spacer can result into G-quadruplex structure. Therefore, the intimate contact between the fluorophore and the GNP results in efficient energy transfer and fluorescence quenching. After hybridization with target DNA, the G-quadruplex stretched and resulted in an enhancement of fluorescence. So the present FRET system can be used for target DNA sensing with detection limit as low as 40pM (S/N=3). In this study, a relation between the fluorescence quenching efficiency and GNP sizes was found and bigger GNPs had higher fluorescence enhancement after hybridization with target DNA.

Contemporaneous cell spreading and phagocytosis: Magneto-resistive real-time monitoring of membrane competing processes

19 November 2012, 09:29:31
Publication year: 2013
Source:Biosensors and Bioelectronics, Volume 40, Issue 1
A. Shoshi, J. Schotter, P. Schroeder, M. Milnera, P. Ertl, R. Heer, G. Reiss, H. Brueckl
Adhesion and spreading of cells strongly depend on the properties of the underlying surface, which has significant consequences in long-term cell behavior adaption. This relationship is important for the understanding of both biological functions and their bioactivity in disease-related applications. Employing our magnetic lab-on-a-chip system, we present magnetoresistive-based real-time and label-free detection of cellular phagocytosis behavior during their spreading process on particle-immobilized sensor surfaces. Cell spreading experiments carried out on particle-free and particle-modified surfaces reveal a delay in spreading rate after an elapsed time of about 2.2h for particle-modified surfaces due to contemporaneous cell membrane loss by particle phagocytosis. Our associated magnetoresistive measurements show a high uptake rate at early stages of cell spreading, which decreases steadily until it reaches saturation after an average elapsed time of about 100min. The corresponding cellular average uptake rate during the entire cell spreading process accounts for three particles per minute. This result represents a four times higher phagocytosis efficiency compared to uptake experiments carried out for confluently grown cells, in which case cell spreading is already finished and, thus, excluded. Furthermore, other dynamic cell-surface interactions at nano-scale level such as cell migration or the dynamics of cell attachment and detachment are also addressable by our magnetic lab-on-a-chip approach.

Highlights

► Magnetoresistive sensing of cell spreading and particle phagocytosis demonstrated. ► Cells uptaking particles saturate at a smaller spreading area than reference cells. ► Difference in spreading area accounts for required membrane area for phagocytosis. ► Sensor signal leads to average bead-to-surface distance of 120nm after uptake. ► Uptake efficiency of spreading cells is 4 times higher compared to confluent cells.