STEM CELLBANKER® from AMSBIO is a chemically defined freezing medium with
optimised formulation for stem cells and iPS cells storage as well as other
valuable cells.
In a recent study to determine the best cryopreservation solution to maintain
induced pluripotent stem (iPS) cells, a team of researchers from the Okayama
University Graduate School of Medicine (Japan) compared 12 kinds of
commercially prepared cryopreservation solutions and found that STEM
CELLBANKER** outperformed the other 11 solutions. The researchers concluded
that STEM CELLBANKER** showed the highest cell viability and proliferation of
all the solutions tested and can be widely used as it does not require any
special skills to use.
Co-author of the study - Hirofumi Noguchi, MD, PhD, Department of
Gastroenterological Surgery, Transplant and Surgical Oncology at the Okayama
University Graduate School of Medicine commented "iPS cells are a
promising alternative to embryonic stem cells and can be used in place of bone
marrow cells, stromal cells and adipose tissue-derived stem cells". He
added "However, the viability of human iPS cells, like embryonic stem
cells, decreases significantly during cryopreservation. A wide variety of
cryopreservation solutions have been used, however many are toxic or
ineffective for use in extended cryopreservation."
Supplied ready-to-use with a simple usage protocol, STEM CELLBANKER is
completely free of serum and animal derived components, and contains only
Japanese, European or US Pharmacopoeia graded ingredients. STEM CELLBANKER
significantly increases cell viability while maintaining cell pluripotency,
normal karyotype and proliferation ability following resuscitation from
cryopreservation, even after extended long-term storage. Independent research
has demonstrated that hESC, MSCs and iPS cells cryopreserved with STEM
CELLBANKER produce significantly higher cell viability (> 90%) over
conventional freezing medium, while retaining cell pluripotency, normal
karyotype and proliferation ability. Every batch of STEM CELLBANKER
cryopreservation medium is performance tested on Jurkat and SK-007 cells.
Additional standard evaluations for endotoxins, pH, osmolarity and Mycoplasma
contaminants are undertaken to ensure GMP equivalent quality.
The study, published in a special issue of Cell Medicine, can be viewed at http://www.ingentaconnect.com/content/cog/cm/2012/00000003/F0030001/art00012. For further information on STEM CELLBANKER
please visit www.amsbio.com/STEM-CELLBANKER-Stem-Cell-Cryopreservation-Solution.aspx
or contact AMSBIO on +44-1235-828200 / +1-949-768-8365 or email info@amsbio.com.
This blog has been set up for editors, reviewers, authors and readers of Elsevier's Analytical Chemistry Journals - all of which can be seen below. It will be updated from Monday to Friday with general news and announcements concerning the titles listed on this page. It should be noted that the views or claims made in the news items and feeds are not necessarily those of the Publisher.
Tuesday, 28 May 2013
Effective Cryopreservation of iPS Cells
Friday, 10 May 2013
Just Published: Trends in Analytical Chemistry
A new issue of this journal has just
been published. To see abstracts of the papers it contains (with links through
to the full papers) click here:
Trends in Analytical Chemistry
http://rss.sciencedirect.com/publication/science/5787
http://rss.sciencedirect.com/publication/science/5787
Selected
papers from the latest issue:
1.
|
Analysis
of biopharmaceutical proteins in biological matrices by LC-MS/MS I. Sample
preparation Review Article
Available online 13 April 2013 Rainer Bischoff, Kees J. Bronsema, Nico C. van de Merbel |
|
|
|
2.
|
Analytical
Strategies for Real-Time and Non-Invasive Tracking of Carbon Nanomaterials in vivo
Review Article
Available online 13 April 2013 Aijuan Liu, Shumei Zhai, Bin Zhang, Bing Yan |
|
|
|
3.
|
Analytical
and bioanalytical problems associated with the toxicity of elemental sulfur
in the environment Review Article
Available online 13 April 2013 Karolina Kuklińska, Lidia Wolska, Jacek Namieśnik, Monika Cieszyńska, Lidia Wolska |
|
|
|
4.
|
Functionalization
and dispersion of carbon nanotubes in ionic liquids Review Article
Available online 12 April 2013 M.L. Polo-Luque, B.M. Simonet, M. Valcárcel |
|
|
|
5.
|
Stationary
phases for separation of nucleosides and nucleotides by hydrophilic
interaction liquid chromatography Review Article
Available online 12 April 2013 D. García-Gómez, E. Rodríguez-Gonzalo, R. Carabias-Martínez |
|
|
|
6.
|
Pittcon
logs another success
Available online 12 April 2013 I. Mitch Taylor, Stephen R. Groskreutz, Andrea Jaquins Gerstl, Jing Zhang, Stephen G. Weber |
|
|
|
7.
|
In
the news
Available online 10 April 2013 |
|
|
|
8.
|
New
materials in solid-phase microextraction Review Article
Available online 9 April 2013 Jianqiao Xu, Juan Zheng, Jingyu Tian, Fang Zhu, Feng Zeng, Chengyong Su, Gangfeng Ouyang |
|
KF Coulometric Titrator Ideal for Trace Water Level Content
JM Science announces their
new AQUACOUNTER® Karl Fischer Coulometric Titrator (AQ-2200S). This high-end
titrator is ideal for the trace level water content determination with its
excellent capability and upgraded performance.
It will be of interest for users who: 1) have many kinds of
samples to be analyzed; 2) exchange KF reagents frequently or after each
measurement; 3) are eco-minded and budget-conscious.
The titrator allows two titration stations to run parallel
with various coulometric/volumetric combinations. With both a volumetric and
coulometric channel, one can measure moisture over the entire range from 1 ppm
to 100% or double your sample throughput with 2 identical KF stations. This
design is economical and ecological because it reduces the use of expensive KF reagents. Three types of
electrolytic cells are available including small volume, standard, and one-room
cell. There is an ultra-trace moisture measurement mode equipped in this
titrator with an accuracy of ≤10µgH20.
The cell design allows for easy assembly and maintenance. The 7.5-inch
color touch screen is easy to read and operate. It has enhanced memory capacity
and user may store results on a USB flash
memory stick. The stored data can be read out on the color display. Result data
with curves may be viewed on a PC internet browsing program with optional
software. This titrator comes equipped with a built-in thermal printer with
easy paper loading and high-resolution printouts. It can be used with
peripherals of previous versions.
NEW Economical Tubing Pumps
Aalborg® Instruments announced the expansion of its
economical TP Peristaltic Pump line. TPV models are designed for
liquids of low to high viscosity and can also accommodate fuels with the
appropriate tubing.
TPV Pump Systems ensure stable performance
and accurate, repeatable liquid transfer applications. They are ideal for
laboratory, processing, and OEM applications.
TPV Pump Features: All Models
- Long tubing life
- 3 - 316 stainless steel
rollers and shafts
- Can be mounted in any
direction
- Controls for prime,
brake, rpm, reverse flow direction, power LED
- Adjustable handle to
carry, hang, or stand pump
- Safety cover
- Maintenance-free 24 VDC
brushless motor
- Speed adjustable from 0
to 300 rpm
- Unique adjustable tubing
holder assembly
- Fixed occlusion wall
TPV Pump Systems and Additional Model Features:
Pump Heads: Simply attach the pump head to your
motor via existing mounting holes or to one purchased from Aalborg®.
TPVAD: AD Model Adjustable RPM Pumps: Standard
features.
TPVDP: DP Model Adjustable RPM Pumps with Dispensing:
Remote Start/Stop option is available. Set timer relay to dispense or to stop
dispensing liquids over a selected time period to either Shot Mode or to
Continuous Pulse Mode.
TPVRP: RP Model Adjustable RPM Pumps with Dispensing: Set
timer relay to dispense liquids for a selected time period and to stop
dispensing for another selected time period.
Flow Rate Ranges: 8 ml/min to 377 ml/min
dependent on motor speed and tubing size.
Thursday, 9 May 2013
Just Published:Biosensors & Bioelectronics
A new issue of this journal has just
been published. To see abstracts of the papers it contains (with links through
to the full papers) click here:
Biosensors & Bioelectronics
http://rss.sciencedirect.com/publication/science/5223
http://rss.sciencedirect.com/publication/science/5223
Selected
papers from the latest issue:
|
|
1.
|
Fluorescent
Molecularly Imprinted Polymer Thin Films for Specific Protein Detection
Prepared with Dansyl Ethylenediamine-Conjugated O-Acryloyl L-Hydroxyproline
Original Research
Article
Available online 6 April 2013 Yuki Inoue, Atsushi Kuwahara, Kohei Ohmori, Hirobumi Sunayama, Tooru Ooya, Toshifumi Takeuchi |
|
|
|
2.
|
MultisHRP-DNA-coated
CMWNTs as signal labels for an ultrasensitive hepatitis C virus core antigen
electrochemical immunosensor Original Research Article
Available online 6 April 2013 Cuixia Ma, Mo Liang, Li Wang, Hua Xiang, Yingtao Jiang, Yiyan Li, Guoming Xie |
|
|
|
3.
|
Naked-eye
Detection of Nucleic Acids through Rolling Circle Amplification and Magnetic
Particle Mediated Aggregation Original Research Article
Available online 6 April 2013 Caiqin Lin, Yunxia Zhang, Xin Zhou, Bo Yao, Qun Fang
Graphical abstract
|
|
|
|
4.
|
A
compact hybrid-multiplexed potentiostat for real-time electrochemical
biosensing applications Original Research Article
Available online 6 April 2013 Ioannis Ramfos, Nikolaos Vassiliadis, Spyridon Blionas, Konstantinos Efstathiou, Alex Fragoso, Ciara K. O'Sullivan, Alexios Birbas |
|
|
|
5.
|
Ultrafast
Molecular Motor Driven Nanoseparation and Biosensing Original Research Article
Available online 6 April 2013 Mercy Lard, Lasse ten Siethoff, Saroj Kumar, Malin Persson, Geertruy te Kronnie, Heiner Linke, Alf Månsson |
|
|
|
6.
|
Electrochemical
cholesterol sensor based on carbon nanotube @molecularly imprinted polymer
modified ceramic carbon electrode Original Research Article
Available online 6 April 2013 Yuejin Tong, Haidong Li, Huaimin Guan, Jianming Zhao, Saadat Majeed, Saima Anjum, Feng Liang, Guobao Xu |
|
|
|
7.
|
Miniaturized
flow system based on enzyme modified PMMA microreactor for amperome5tric
determination of glucose Original Research Article
Available online 6 April 2013 Luís Marcos Cerdeira Ferreira, Eric Tavares da Costa, Claudimir Lucio do Lago, Lúcio Angnes |
|
|
|
8.
|
Label-free
and sensitive strategy for microRNAs detection based on the formation of
boronate ester bonds and the dual-amplification of gold nanoparticles
Original Research
Article
Available online 6 April 2013 Ning Xia, Liping Zhang, Guifang Wang, Qingqin Feng, Lin Liu |
|
|
|
9.
|
Supersandwich-type
electrochemiluminescenct aptasensor based on Ru (phen)32+ functionalized
hollow gold nanoparticles as signal-amplifying tags Review Article
Available online 6 April 2013 Guofeng Gui, Ying Zhuo, Ya-Qin Chai, Ni Liao, Min Zhao, Jing Han, Qiang Zhu, Ruo Yuan, Yun Xiang |
|
|
|
10.
|
Time-resolved
chemiluminescence strategy for multiplexed immunoassay of clenbuterol and
ractopamine
Available online 6 April 2013 Jing Han, Hongfei Gao, Wenwen Wang, Zhenxing Wang, Zhifeng Fu |
|
|
|
11.
|
Potentiometric
sensing of nuclease activities and oxidative damage of single-stranded DNA
using a polycation-sensitive membrane electrode Original Research Article
Available online 6 April 2013 Jiawang Ding, Wei Qin |
|
|
|
12.
|
Development
of a high-sensitivity immunoassay for amyloid-beta 1–42 using a silicon
microarray platform Original Research Article
Available online 6 April 2013 Paola Gagni, Laura Sola, Marina Cretich, Marcella Chiari |
|
|
|
13.
|
Bead
Assembly Magnetorotation as a Signal Transduction Method for Protein
Detection Original
Research Article
Available online 6 April 2013 Ariel Hecht, Patrick Commiskey, Nicholas Shah, Raoul Kopelman |
|
|
|
14.
|
Ultrasensitive
and Selective Gold Film-based Detection of Mercury (II) in Tap Water Using a
Laser Scanning Confocal Imaging-surface Plasmon Resonance System in Real Time
Original Research
Article
Available online 5 April 2013 Hongyan Zhang, Liquan Yang, Bingjiang Zhou, Weimin Liu, Jiechao Ge, Jiasheng Wu, Ying Wang, Pengfei Wang |
|
|
|
15.
|
Nickel
Nanoparticle-Chitosan-Reduced Graphene Oxide-Modified Screen-Printed
Electrode for Enzyme-Free Glucose Sensing in Portable Microfluidic Devices
Original Research
Article
Available online 3 April 2013 Jiang Yang, Ji-Hyuk Yu, J. Rudi Strickler, Woo-Jin Chang, Sundaram Gunasekaran |
|
|
|
16.
|
Stainless
steel modified with an aminosilane layer and gold nanoparticles as a novel
disposable substrate for impedimetric immunosensors Original Research Article
Available online 3 April 2013 Behzad Rezaei, Elaheh Havakeshian, Ali A. Ensafi |
|
|
|
17.
|
Improving
Biocompatibility by Surface Modification Techniques onImplantable
Bioelectronics Review Article
Available online 3 April 2013 Peter Lin, Chii-Wann Lin, Raafat Mansour, Frank Gu |
|
|
|
18.
|
LSI-based
amperometric sensor for real-time monitoring of embryoid bodies
Original Research
Article
Available online 3 April 2013 Mustafa Şen, Kosuke Ino, Kumi Y. Inoue, Toshiharu Arai, Taku Nishijo, Atsushi Suda, Ryota Kunikata, Hitoshi Shiku, Tomokazu Matsue |
|
|
|
19.
|
A
generic microfluidic biosensor of G protein-coupled receptor activation -
Monitoring cytoplasmic [Ca2+] changes in human HEK293 cells
Original Research
Article
Available online 3 April 2013 Margriet Roelse, Norbert C.A. de Ruijter, Elwin X. Vrouwe, Maarten A. Jongsma |
|
|
|
20.
|
Simultaneous
capture and in situ
analysis of circulating tumor cells using multiple hybrid nanoparticles
Original Research
Article
Available online 3 April 2013 Hun Joo Lee, Hyeon-Yeol Cho, Jin Ho Oh, Kak Namkoong, Jeong Gun Lee, Jong-Myeon Park, Soo Suk Lee, Nam Huh, Jeong-Woo Choi
Graphical abstract
|
|
|
|
21.
|
Electrochemical
sensor based on molecularly imprinted polymer film via sol-gel technology and
multi-walled carbon nanotubes-chitosan functional layer for sensitive
determination of quinoxaline-2-carboxylic acid Original Research Article
Available online 2 April 2013 Yukun Yang, Guozhen Fang, Guiyang Liu, Mingfei Pan, Xiaomin Wang, Lingjie Kong, Xinlei He, Shuo Wang |
|
|
|
22.
|
3-Aminophenyl
boronic acid-functionalized CuInS2 quantum dots as a near-infrared
fluorescence probe for the determination of dopamine Original Research Article
Available online 2 April 2013 Siyu Liu, Fanping Shi, Xiaojun Zhao, Lu Chen, Xingguang Su |
|
|
|
23.
|
An
amperometric glutamate biosensor based on immobilization of glutamate oxidase
onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan
composite film modified Au electrode Original Research Article
Available online 2 April 2013 Bhawna Batra, C.S. Pundir |
|
|
|
24.
|
A
simple and sensitive fluorescence biosensor for detection of organophosphorus
pesticides using H2O2-sensitive quantum dots/bi-enzyme Original Research Article
Available online 2 April 2013 Xianwei Meng, Jianfei Wei, Xiangling Ren, Jun Ren, Fangqiong Tang |
|
|
|
25.
|
A
sensitive electrochemical aptasensor for thrombin detection based on
exonuclease-catalyzed target recycling and enzyme-catalysis
Original Research
Article
Available online 2 April 2013 Huayu Yi, Wenju Xu, Yali Yuan, Yongmei Wu, Yaqin Chai, Ruo Yuan |
|
|
|
26.
|
Longitudinal
surface plasmon resonance assay enhanced by magnetosomes for simultaneous
detection of Pefloxacin and Microcystin-LR in seafoods Original Research Article
Available online 1 April 2013 Xiulan Sun, Longyun Wu, Jian Ji, Donglei Jiang, Yinzhi Zhang, Zaijun Li, Genyi Zhang, Hongxia Zhang |
|
|
|
27.
|
Sensitive
chemiluminescence detection of wild-type p53 protein captured by
surface-confined consensus DNA duplexes
Available online 1 April 2013 Xiaolan Chen, Chuhua He, Zhifan Zhang, Jianxiu Wang |
|
|
|
28.
|
Highly
sensitive recognition of Pb2+ using Pb2+ triggered exonuclease aided DNA
recycling
Available online 31 March 2013 Hui Xu, Pingping Xu, Shanmin Gao, Shengxiao Zhang, Xingchun Zhao, Chunhai Fan, Xiaolei Zuo |
|
Analyzing Soil Samples for Percentage Carbon, Hydrogen & Nitrogen
Application note 51*
from Exeter Analytical Inc. illustrates how the Carbon, Hydrogen and Nitrogen
(CHN) content of soil samples can be precisely and reproducibly determined
using their Model 440 Elemental Analyzer.
The determination of the Carbon, Hydrogen and Nitrogen (CHN) content of soil samples is of major interest to environmental and agrochemical laboratories throughout the world. Organic matter is known to directly influence the productive capacity of different soils as it is a major contributor of C, H as well as N, P, S and other nutrients. Percentage Carbon can be determined in both its inorganic and organic forms via acid pre-treatment or temperature differential measurement using an Exeter Analytical Model 440 Elemental Analyzer. The determination of the Nitrogen content of soils using a Model 440 Elemental Analyser saves considerable time and cost with no diminishment of data quality compared with the traditional Kjeldahl nitrogen determination method.
This application note includes details of the analytical methodology used plus data demonstrating the high quality of CHN data determination that is possible using a Model 440 Elemental Analyzer.
The Exeter Analytical Model 440 is a static combustion CHN Elemental Analyzer, with a unique horizontal furnace design, which enables easy removal of sample residue between each soil analysis. Consequently one combustion tube will analyze in excess of 1000 soil samples without the need for removal and cleaning. By comparison other elemental analyzers, employing vertical furnace designs, will require cleaning after as little as 20 samples. The gas flow characteristics of the Model 440 analyzer are superior to other elemental analyzers due to the effective elimination of troublesome residue build-up. This thereby provides longer-term calibration stability as well as enhanced accuracy and precision for measured soil sample data.
In addition, as the Model 440 provides complete control over combustion parameters it is able to reproducibly achieve 100% combustion with the widest range of soil samples. Proprietary Nitrogen analysis software uniquely enables accurate measurement of low Nitrogen levels (in the 0.1-0.2% range) with a high degree of accuracy.
For a copy of this new application note please contact Exeter Analytical on +1-978-251-1411 / +44-2476-323223 (in Europe) or email sales@eai1.com.
The determination of the Carbon, Hydrogen and Nitrogen (CHN) content of soil samples is of major interest to environmental and agrochemical laboratories throughout the world. Organic matter is known to directly influence the productive capacity of different soils as it is a major contributor of C, H as well as N, P, S and other nutrients. Percentage Carbon can be determined in both its inorganic and organic forms via acid pre-treatment or temperature differential measurement using an Exeter Analytical Model 440 Elemental Analyzer. The determination of the Nitrogen content of soils using a Model 440 Elemental Analyser saves considerable time and cost with no diminishment of data quality compared with the traditional Kjeldahl nitrogen determination method.
This application note includes details of the analytical methodology used plus data demonstrating the high quality of CHN data determination that is possible using a Model 440 Elemental Analyzer.
The Exeter Analytical Model 440 is a static combustion CHN Elemental Analyzer, with a unique horizontal furnace design, which enables easy removal of sample residue between each soil analysis. Consequently one combustion tube will analyze in excess of 1000 soil samples without the need for removal and cleaning. By comparison other elemental analyzers, employing vertical furnace designs, will require cleaning after as little as 20 samples. The gas flow characteristics of the Model 440 analyzer are superior to other elemental analyzers due to the effective elimination of troublesome residue build-up. This thereby provides longer-term calibration stability as well as enhanced accuracy and precision for measured soil sample data.
In addition, as the Model 440 provides complete control over combustion parameters it is able to reproducibly achieve 100% combustion with the widest range of soil samples. Proprietary Nitrogen analysis software uniquely enables accurate measurement of low Nitrogen levels (in the 0.1-0.2% range) with a high degree of accuracy.
For a copy of this new application note please contact Exeter Analytical on +1-978-251-1411 / +44-2476-323223 (in Europe) or email sales@eai1.com.
Gordon F. Kirkbright Bursary Award, 2014
The Gordon F. Kirkbright bursary award is
a prestigious annual award that enables a promising student/non-tenured young
scientist of any nation to attend a recognised scientific meeting or visit a
place of learning.
The fund for this bursary was established
in 1985 as a memorial to Professor Gordon Kirkbright in recognition of his
contributions to analytical spectroscopy and to science in general. Although
the fund is administered by the Association of British Spectroscopists (ABS)
Trust, the award is not restricted to spectroscopists.
Applications are invited for the 2014 Gordon Kirkbright Bursary.
For further information contact John Chalmers at, email:
vibspecconsult@aol.com
The closing date for entries is 31
December 2013.
Subscribe to:
Posts (Atom)




