Thursday, 8 March 2012

Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Quantifying Injection Solvent Effects in Reversed-Phase Liquid Chromatography

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 7 March 2012
Bradley J. VanMiddlesworth, John G. Dorsey
Peak distortion due to the injection was measured as a function of injection solvent strength, volume, mass, retention factor, and column selectivity. The concept of a method's sensitivity (s) to injection solvent strength was mathematically defined as a vector of theoretical plate counts compared to an ideal vector that does not change with injection solvent strength. Near ideal sensitivity (s > 0.90) was measured on all columns with all analytes in low volume injections of 1.25 μL. Increasing the injection volume reduces the measured sensitivity from ideality to a greater extent than increasing the injection mass, with differing values for each column.Using column parameters measured from the hydrophobic-subtraction model and fitting parameters from the acetonitrile excess adsorption isotherm, differences among the columns studied are explained. Decreased ligand density and increased silanol activity provide a consistent peak shape with changes in injection volume or solvent strength. For method development, a quick test is suggested with the ratio of hydrophobic-subtraction column parameters, H/A, to predict the injection solvent sensitivity of a column. As H/A decreases, the sensitivity to injection solvent worsens. Sensitivity to organic modifiers other than acetonitrile are predicted with cited sorbed layer thickness, such that MeOH > EtOH > IPA ≈ THF ≈ MeCN, i.e., a strong MeOH diluent is more ideal (better) than a strong MeCN diluent.

Highlights

► Peak distortion from injection solvent effects was measured and quantified. ► Peak distortion occurs with increasing injection volume and solvent strength. ► A predictive test is proposed to estimate column sensitivity to these issues.

Simultaneous Determination of Fluoxetine and Norfluoxetine Enantiomers using Isotope Discrimination Mass Spectroscopy Solution Method and its Application in the CYP2C9-Mediated Stereoselective Interactions

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 7 March 2012
Lushan Yu, Shenjia Wang, Huidi Jiang, Hui Zhou, Su Zeng
In this study, we developed an LC-MS/MS method based on an isotope discrimination mass spectroscopy solution (IDMSS) technology to simultaneously quantify enantiomers of fluoxetine (FLX) and norfluoxetine (NFLX) in a CYP2C9 incubation mixture.S-FLX andS-NFLX were labeled to formS-FLX-d5 andS-NFLX-d5. The method has several advantages over conventional chiral separation methods, in terms of the analysis period, resolution, and lower limit of quantification. The primary advantage of the method is that the two enantiomers can always be simultaneously determined by mass spectroscopy regardless if they are separated on column or not, owing to which it has high throughput and high sensitivity. The lower limit of quantification (amount on column) is 12.5 and 1.25 pg for FLX and NFLX, respectively. The retention time of FLX, NFLX, and the internal standard is only 1.9 min. The calibration curves were linear over the concentration range of 0.1-100 ng/ml for NFLX and 1-1000 ng/ml for FLX with an accepted reproducible (RSD < 10%) and accurate (CV < 10%). No significant kinetic isotope effect was found in the metabolism ofS-FLX-d5 catalyzed by CYP2C9*1 and CYP2C9*2. The half-maximal inhibitory concentration values betweenR-FLX andS-FLX catalyzed by CYP2C9*1 and CYP2C9*2 were determined in this study. The inhibitory effects ofR- toS-FLX were stronger than those ofS- toR-FLX in both CYP2C9*1 and CYP2C9*2. The IDMSS technology is useful for stereoselective study of chiral compound in vitro.

Highlights

► An isotope discrimination MS solution method was developed for chiral separation. ► Separated on column or not is not affect the enantiomers determination. ► The method has high throughput and high sensitivity. ► No significant kinetic isotope effect was found to theS-fluoxetine-d5 metabolism.

Comparison of indirect and direct quantification of esters of monochloropropanediol in vegetable oil

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 7 March 2012
Mathieu Dubois, Adrienne Tarres, Till Goldmann, Anna Maria Empl, Alfred Donaubauer, ...
The presence of fatty acid esters of monochloropropanediol (MEs) in food is a recent concern raised due to the carcinogenicity of their hydrolysable moieties 2- and 3-monochloropropanediol (2- and 3-MCPD). Several indirect methods for the quantification of MEs have been developed and are commonly in use until today, however significant discrepancies among analytical results obtained are challenging their reliability. The aim of the present study was therefore to test the trueness of an indirect method by comparing it to a newly developed direct method using palm oil and palm olein as examples. The indirect method was based on ester cleavage under acidic conditions, derivatization of the liberated 2- and 3-MCPD with heptafluorobutyryl imidazole and GC-MS determination. The direct method was comprised of two extraction procedures targeting 2-and 3-MCPD mono esters (co-extracting as well glycidyl esters) by the use of double solid phase extraction (SPE), and 2- and 3-MCPD di-esters by the use of silica gel column, respectively. Detection was carried out by liquid chromatography coupled to Time of Flight mass spectrometry (LC-ToF-MS). Accurate quantification of the intact compounds was assured by means of matrix matched standard addition on extracts. Analysis of 22 palm oil and 7 palm olein samples (2- plus 3-MCPD contamination ranged from 0.3 to 8.8 μg/g) by both methods revealed no significant bias. Both methods were therefore considered as comparable in terms of results; however the indirect method was shown to require less analytical standards, being less tedious and furthermore applicable to all type of different vegetable oils and hence recommended for routine application.

Highlights

► We developed a direct method for MCPD esters quantitation by LC-ToF-MS in edible oil. ► Analytical standards were chosen rationally based on theoretical calculation ► 2- and 3-MCPD were also determined by indirect method using acid-hydrolysis and GC-MS ► Direct and indirect methods gave similar results analyzing 29 palm oil/olein samples

Quantification of Matrix Metalloprotease-9 in Bronchoalveolar Lavage Fluid by Selected Reaction Monitoring with Microfluidics nano-Liquid-Chromatography–Mass Spectrometry

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 6 March 2012
Laurette M. Prely, Krisztina Paal, Jos Hermans, Sicco van der Heide, Antoon J.M. van Oosterhout, ...
Quantitative protein analysis by liquid chromatography–tandem mass spectrometry (LC-MS/MS) in the selected reaction monitoring (SRM) mode was used to quantify matrix metalloprotease–9 (MMP-9; ∼ 90 kDa) in bronchoalveolar lavage fluid (BALF) from patients having undergone lung transplantation. We developed an SRM assay for microfluidics-based nanoLC-MS/MS on a triple quadrupole mass spectrometer based on two signature peptides. Samples were prepared by chloroform-methanol precipitation followed by trypsin digestion in the presence of stable-isotope-labeled internal peptide standards. The method allows accurate quantification of MMP-9 in BALF with an LLOQ of 2.9 ng/mL and an LLOD of 0.25 ng/mL without the use of extensive fractionation or antibodies.

Highlights

► Highly sensitive and specific LC-MS/MS method for MMP-9 in BALF ► First application of LC-MS/MS in the SRM mode for protein quantification in BALF ► Accurate quantification at the amol level by microfluidics-nanoLC-MS/MS ► Application to real-life samples from lung transplantation patients

Trace Determination of 13 Haloacetamides in Drinking Water Using Liquid Chromatography Triple Quadrupole Mass Spectrometry with Atmospheric Pressure Chemical Ionization

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 6 March 2012
Wenhai Chu, Naiyun Gao, Daqiang Yin, Stuart W. Krasner, Michael R. Templeton
The haloacetamides (HAcAms) are disinfection by-products (DBPs) in drinking water which are currently receiving increased scientific attention due to their elevated toxicity relative to regulated disinfection by-products. A simultaneous determination method of 13 HAcAms, combining solid-phase extraction (SPE) enrichment, liquid chromatographic (LC) separation, and triple quadrupole mass spectrometry (tqMS) detection with atmospheric pressure chemical ionization (APCI) using selective reaction monitoring in positive mode, was developed to measure HAcAms, including chlorinated, brominated, and iodinated analogues. Ammonium chloride and Oasis HLB were selected as the dechlorinating reagent and polymeric SPE sorbent of HAcAm samples. The used tqMS apparatus showed higher sensitivity for the studied HAcAms in the APCI mode than electrospray Ionization. 13 HAcAms were separated by LC in 9.0 min, and the detection limits ranged from 7.6 to 19.7 ng/L. The SPE-LC/tqMS method was successfully applied to quantify 13 HAcAms in drinking water samples for the first time, and first indentified tribromoacetamide and chloroiodoacetamide as DBPs in drinking water

Highlights

► Determination of 13 HAcAms by SPE + HPLC/tqMS with APCI mode was first developed. ► Ammonium chloride was selected as the dechlorinating reagent, compared to others. ► Oasis HLB sorbent has better enrichment effect than Oasis MCX, MAX, WCX and WAX. ► The tqMS showed higher sensitivity for 13 HAcAms in the APCI mode than ESI mode. ► Two HAcAms (CIAcAm and TBAcAm) were identified as DBPs in water for the first time.

Micellar Electrokinetic Chromatography of Aromatic Anions and Non-ionic Aromatic Compounds with Stepwise Changes of the Concentration of Cetyltrimethylammonium Chloride

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 6 March 2012
Yukihiro Esaka, Miki Kobayashi, Hiroya Murakami, Bunji Uno
Micellar electrokinetic chromatography in which the concentration of cetyltrimetylammmonium chloride (CTAC) was sequentially changed in the separation system was investigated using 10 aromatic anions and 11 non-ionic aromatic compounds as model analytes. All separations were performed in the absence of electroosmotic flow (EOF), and thus, analytes were detected in the order of their strength of interaction with micelles in the system. In isocratic elutions without EOF, the model analytes could be separated better with lower concentrations of CTAC but migration times of the analytes possessing relatively higher polarities increased markedly, and thus, long analysis times were required. Therefore, we attempted to increase the concentration of CTAC during a single measurement to reduce the analysis time without hindering the resultant separation of analytes obtained with lower concentrations. Briefly, the present surfactant stepwiseelution can be performed by a sequential increase in CTAC concentrations of the running solution in the anodic reservoir from 30 to 50 mM for the anions and from 20 to 50 mM for the non-ionic compounds. Additionally, to perform expected gradient separations with good reproducibility, each running solution with a different CTAC concentration was treated with tetraethylammmonium chloride as an additive to adjust electric conductivities of each running solution to be equal. Under this condition, CTAC micelles of each zone of different CTAC concentrations would migrate with practically the same velocity. Consequently, by the present stepwise method, both the 10 anionic analytes and the 11 non-ionic analytes were well separated within reasonable periods which corresponded approximately to two-third and less than half of those by the isocratic elutions, respectively.

Highlights

► Stepwise-elution MEKC changing concentration of micelle during single separation. ► A gradient method changing phase ratio of distribution phases of chromatography. ► Shortening analysis time and improving separation for ionic and non ionic analytes. ► Stable operation by a supporting electrolyte maintaining a fixed electric field.

Application of accelerated solvent extraction in the analysis of organic contaminants, bioactive and nutritional compounds in food and feed

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 6 March 2012
Hanwen Sun, Xusheng Ge, Yunkai Lv, Anbang Wang
Accelerated solvent extraction (ASE) has become a popular green extraction technology for different classes of organic contaminants present in numerous kinds of food and feed for food safety. The parameters affecting ASE efficiency and application advancement of ASE in analysis of organic contaminants, natural toxins compounds as well as bioactive and nutritional compounds in animal origin food, plant origin food and animal feed are reviewed in detail. ASE is a fully automated and reliable extraction technique with many advantages over traditional extraction techniques, so it could be especially useful for routine analyses of pollutants in food and feed.

Graphical abstract


image

Highlights

► Parameters affecting ASE efficiency. ► Multi-residue analysis. ► Organic contaminants, bioactive and nutritional compounds. ► Application of ASE in analysis of animal origin foods, plant origin foods and feeds.

Multiple, Simultaneous, Independent Gradients for Versatile Multidimensional Liquid Chromatography. Part I: Theory

08 March 2012, 00:09:05Go to full article
Publication year: 2012
Source: Journal of Chromatography A, Available online 6 March 2012
Allen G. Hirsh, Latchezar I. Tsonev
The general method for constructing coupled dual gradients in liquid chromatography (LC) is to begin by filling a reservoir A with a solution of one mobile phase (MP) component at concentration [C1(A)] and a second MP component at concentration [C2(A)], followed by filling a reservoir B with a solution containing MP component one at concentration [C1(B)] and the second MP component at concentration [C2(B)]. In another scenario the reservoirs A and B are filled with solutions of only one MP component at different concentration [C1(A)] and [C1(B)] and the two solutions are titrated to a different pH value: pH (A) for the reservoir A and pH (B) for the reservoir B respectively. In either case, mixing of flows from the two reservoirs varies the concentrations of the two MP components (MP solutes) or the concentration of one MP component and pH along a particular compositional curve producing an eluent with two compositionally coupled gradients. This is a kind of a two dimensional LC utilizing dual simultaneous dependent gradients (DSDGs) wherein two parameters affecting the binding free energy of an analyte to a stationary phase (SP) are being altered simultaneously. Such a DSDG suffers from a significant limitation in that the gradient concentration of the two solutes or the concentration of one MP component and the pH cannot be varied independently. The only way to attain an optimal multigradient LC system, that promises a remarkable increase in chromatographic resolution of complex analyte mixtures, is to uncouple the multiple (dual) gradients, making each independent of the other(s). In this paper the theory of uncoupling ofnsuch gradients,n≥2 is developed. It is shown that fornsolutes 2reservoirs are required in concert with an LC eluent delivery system capable of freely apportioning the flows among the reservoirs according to equations we develop here. We go on to predict a substantial increase in chromatographic resolution when applying dual simultaneous independent gradients (DSIGs) of salt and pH to fractionate difficult to separate proteins. This prediction is naturally explained by the electrostatic interaction theory of protein binding to an ion exchanger. In subsequent experimental papers it will be shown that the algorithms presented here properly instruct a quad pump HPLC system to produce well controlled independent simultaneous gradients of pH and non-buffering solutes with attendant significant gain in chromatographic resolution of complex mixtures of protein isoforms.

Highlights

► Algorithms for simultaneous independent gradients (SIGs) of ≥2 solutes in HPLC ► Algorithms for SIGs of ≥1 solutes plus pH (SIGspH) in HPLC ► Theoretical comparison of SIGspH and salt elution in ion exchange chromatography.

Determining CHN composition of filter samples

Exeter Analytical has developed a sensitive and precise protocol for direct determination of total Carbon (C), Hydrogen (H) and Nitrogen (N) in air and water filter samples.

Filtering air and water samples and determining the chemical composition of the filtrate is of widespread interest to environmental laboratories. Using an Exeter Analytical Model 440 CHN elemental analyser to determine percentage C, H and N of filtered samples is a technique favoured by many labs because the method requires a minimum of sample preparation and may be used for single samples or automated for higher throughput environments.

Developed in conjunction with several leading environmental testing labs the protocol for determining CHN composition of filter samples is described in Exeter Analytical application note 210.

Direct determination of total CHN retained on a filter is more sensitive, precise and cost-effective than making measurements on pre- and post- filtered samples and calculating the difference1. Direct determination is preferred over the traditional "by difference" method because of the reduced sources of error, rapidity of analysis and increased sample representativeness due to the greater volume filtered.

The Exeter Analytical Model 440 employs a static combustion system, with a unique horizontal furnace design, which enables easy removal of filter and sample ash between each analysis.  Consequently one combustion tube will analyse in excess of 1000 samples without the need for removal and cleaning.  In addition the Model 440 provides the capacity to process filters up to 50 mm in diameter in one analytical cycle.  By comparison other elemental analysers, employing vertical furnace designs, need cleaning after as little as 20 samples and larger filters have to be sub sampled several times and then corrective calculations made to enable analysis.
Effectively eliminating troublesome residue build-up the gas flow characteristics of the Model 440 analyser are superior to other elemental analysers thereby providing longer-term calibration stability as well as enhanced accuracy and precision for measured sample data. The Model 440 also provides complete control over combustion parameters enabling the analysis of filters without the need for expensive tin capsules.

For further information on direct determination of Carbon, Hydrogen and Nitrogen in environmental air and water filter samples please contact Exeter Analytical on tel. +44-2476-323223 (+1-978-251-1411 in North America) or email info@exeteranalytical.co.uk (sales@eai1.com in North America).

Wednesday, 7 March 2012

Just Published: Sensors & Actuators B: Chemical

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Comparison of nitric oxide binding to different pure and mixed protoporphyrin IX monolayers

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Wout Knoben, Mercedes Crego-Calama, Sywert H. Brongersma
The nitric oxide (NO) binding properties of monolayers of four different protoporphyrins IX adsorbed on aluminum oxide surfaces have been investigated. XPS and AFM results are consistent with the presence of a monolayer of porphyrins, bound to the surface by their carboxylic acid groups and with the porphine ring oriented more or less perpendicular to the surface. Kelvin probe measurements were done in which the samples were exposed to varying NO concentrations. NO binds strongly to all porphyrins, but protoporphyrin IX zinc(II) (Zn-PP) shows the most promising response. The response rate could be increased by adding spacer molecules to the porphyrin layer. Low ppb levels of NO were easily detected in ambient conditions. The NO binding properties of Zn-PP compare favorably to those of other porphyrins which were previously used for NO sensing. This makes Zn-PP a new and promising candidate for this application.

A highly sensitive nitric oxide biosensor based on hemoglobin-chitosan/graphene-hexadecyltrimethylammonium bromide nanomatrix

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Wei Wen, Wei Chen, Qiong-Qiong Ren, Xiao-Yan Hu, Hua-Yu Xiong, ...
Nitric oxide (NO) is a key signaling molecule in different physiological processes of plants. It is therefore very important to establish a simple, fast, sensitive and accurate detection method for NO detection. In this study, a novel amperometric biosensor based on immobilization of hemoglobin (Hb), chitosan (CS), graphene (GR) and the surfactant hexadecyltrimethylammonium bromide (CTAB) on a glassy carbon electrode was constructed to quantitatively measure NO. Atomic force microscopy, scanning electron microscopy and electrochemical methods were used to characterize the Hb-CS/GR-CTAB nanocomposite film. The biosensor fabricated from the nanocomposite film showed direct electrochemistry with a fast electron-transfer rate (60.3 s) and high electrocatalytic activity towards the reduction of NO. Under optimal conditions, the resulting biosensor exhibited a high sensitivity of 615 μA mM, a low detection limit of 6.75 × 10 M (S/N = 3) and a small apparent Michaelis-Menten constant of 0.315 μM. These results were superior to those for biosensors based on the graphite, GR/ionic liquid and carbon nanotubes. The biosensor was also used successfully for detection of additional NO in oilseed rape leaf homogenate samples. Furthermore, the biosensor had excellent long-term storage stability, as well as reproducibility and selectivity, and should have a potential application in monitoring NO in plant samples.

A Breakthrough in Gas Diagnosis with a Temperature-Modulated Generic Metal Oxide Gas Sensor

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Faramarz Hossein-Babaei, Amir Amini
Sharp operating temperature fluctuations in an analyte-exposed gas sensor result in temporal responses containing considerable amounts of extractable analyte-related information. Due to their high thermal capacity, applying step heating voltages fails to provide step temperature variations in generic metal oxide gas sensors. On the other hand, the custom-made low thermal capacity sensors are vulnerable to thermal noise and environmental agitations in field applications. A novel technique is reported here for inducing the sharp pallet temperature rises required for obtaining selective responses in commonly used bulk tin oxide gas sensors, affording the gas discrimination capacity sought after since the advent of these typically non-selective, though user friendly, devices. In this technique, a voltage spike surpassing the nominal heating voltage of the device is applied prior to a voltage step. The thermal impact of the spike is adjusted to obtain step-like temperature profiles with rise times less than 1/10 of the sensor thermal time-constant. The temporal responses recorded for 12 different airborne analytes, each in a wide concentration range, appear different enough to identify contaminants with minimal computational cost. Analyte examination and recognition take only 4 s. In addition to analyte discrimination, the fabricated prototype also classifies the analytes in terms of their molecular structures of, for example, alcohols and ketones. This single-sensor gas diagnosis device is presented as a potential replacement for array-based electronic nose systems in a number of applications.

Capacitive humidity sensing properties of SiC nanowires grown on silicon nanoporous pillar array

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Hai Yan Wang, Yong Qiang Wang, Qing Fei Hu, Xin Jian Li
A large quantity of entangled SiC nanowires (nw-SiC) with an average diameter of ∼15 nm were grown on a silicon nanoporous pillar array (Si-NPA) by a catalyst-assisted chemical vapor deposition method. The room-temperature capacitive humidity sensing properties ofnw-SiC/Si-NPA were studied by evaporating coplanar interdigital silver electrodes onto its surface. With the relative humidity (RH) changing from 11% to 95%, a capacitance increment over 960% was achieved at the measuring frequency of 100 Hz. The response and recovery times were measured to be ∼105 and 85 seconds, respectively, with a maximum humidity hysteresis of 4.5% at 75% RH. The humidity sensor was also proved to be with high measurement reproducibility and long-term stability. Our results indicate that one-dimensional SiC materials might be competitive as a novel sensing material for fabricating humidity sensors with high performances.

Differential pulse voltammetric analysis of lead in vegetables using a surface amino-functionalized exfoliated graphite nanoplatelet chemically modified electrode

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Ion Ion, Alina Catrinel Ion
A surface amino-functionalized (-CO-NH2) exfoliated graphite nanoplatelet (xGnP) bismuth-modified electrode (-CO-NH2-xGnP/glassy carbon electrode GCE) for the determination of lead was developed and characterized. The hybrid material was characterized by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The electrochemical properties of the -CO-NH2–xGnP bismuth-modified electrode were characterized by a physical deposition method, depositing the film on a graphite electrode. The differential pulse response was linear over the Pb(II) concentration range of 0.005–0.045 μg L, with a limit of detection of 0.001 μg L, and the linear regression equation was y = 3.75x + 0.73. In vegetable juice (cabbage), the current increased linearly relative to the Pb(II) concentrations over the concentration range 0.005 to 0.035 μg Lwith the corresponding linear regression equations: y = 13.06x + 0.46, R = 0.9970.

Effect of pH on the morphology and gas sensing properties of ZnO nanostructures

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 5 March 2012
Onkar Singh, Manmeet Pal Singh, Nipin Kohli, Ravi Chand Singh
Morphology dependent gas sensing behaviour of zinc oxide has been reported in this paper. Nanostructures of zinc oxide have been synthesized by following a precipitation route at various pH values of the precursor solution. Structural and morphological analyses were carried out by using XRD and FESEM techniques. The XRD pattern confirmed wurtzite hexagonal structure of ZnO. The FESEM study revealed that ZnO synthesized at pH 8 developed nanorod like structure, rods got fused together when synthesized at pH 9 and 10, whereas synthesis at pH 11 resulted in transformation of rods into nanoparticles. The thick films of synthesized samples were deposited on alumina substrate and their sensing response to methanol, ethanol and propanol was investigated at different operating temperatures. It was observed that all the sensors exhibited optimum sensing response at 400 °C. It has also been observed that sample prepared at pH 11, constituting nanoparticles, exhibited high sensing response than an assembly of nanorods prepared at pH 8-10. Sensing response of all the samples tested was significantly higher towards propanol vapour than towards that of methanol and ethanol.

A novel nonenzymatic hydrogen peroxide sensor based on reduced graphene oxide/ZnO composite modified electrode

06 March 2012, 02:35:51Go to full article
Publication year: 2012
Source: Sensors and Actuators B: Chemical, Available online 3 March 2012
Selvakumar Palanisamy, Shen-Ming Chen, R. Saraswathi
A novel nonenzymatic, amperometric sensor for hydrogen peroxide (H2O2) was developed based on an electrochemically prepared reduced graphene oxide (RGO)/zinc oxide (ZnO) composite using a simple and cost effective approach. RGO/ZnO composite was fabricated on a glassy carbon (GCE) electrode by a green route based on the electrodeposition of ZnO on graphene oxide (GO). The morphology of the as-prepared RGO/ZnO composite was investigated by scanning electron microscopy (SEM). Attenuated total reflectance (ATR) spectroscopy has also been performed to confirm the ample reduction of oxygen functionalities located at graphene oxide (GO). The electrochemical performance of the RGO/ZnO composite modified GCE was studied by amperometric technique, and the resulting electrode displays excellent performance towards hydrogen peroxide (H2O2) at -0.38 V in the linear response range from 0.02–22.48 μM, with a correlation coefficient of 0.9951, and short response time (<5 s). The proposed sensor also has good operational and storage stability with appreciable anti-interferring ability.

Measure Viscosity with 20µl (microliter) Samples

RheoSense Inc. has developed a viscosity test protocol for its m‑VROC viscometer that achieves viscosity measurement using only 20µl (microliter) of sample fluid.
This micro sample measurement is the lowest in the industry. The test protocol is fully explained in their new applications note; “Small sample viscosity measurements using 20µl (microliter) sample volumes with the RheoSense m‑VROC viscometer”.
To download this test protocol go to: http://www.rheosense.com/APP16.pdf
“Working with customers, especially in protein formulation, we heard a common need to reduce measurement sample size because the fluids were so expensive.” said Matt Chamberlain, Product Marketing Director. “By providing a measurement protocol which uses only 20µl (microliter) of sample, our m-VROC viscosity measurement system can save customers tens to hundreds of thousands of dollars per year in material costs when compared to similar viscometers in use today.”
The m‑VROC viscosity measurement system already had the smallest sample size in the industry at 50µl (microliter). RheoSense Inc. is continuing to improve its patented VROC technology to provide more value to customers.
Phone: 925-866-3801
E-mail: sales@rheosense.com
or visit our Web site: http://www.rheosense.com/

Bioanalytical Sensors

June 17-22, 2012
Salve Regina University
Newport, RI
Chair: Steven A. Soper 

Vice Chairs: 
Susan Lunte & Paul S. Cremer

The 2012 GRC on Bioanalytical Sensors (June 17-22, Salve Regina) will present cutting-edge research in a highly multidisciplinary atmosphere by leaders in the field. This GRC will serve as a conduit for collegial discussions of unpublished data in biochemistry, biology, chemistry, engineering, medicine, and physics as they apply to the development and applications of bioanalytical sensors. This meeting will bring together a diverse group of participants ranging from technologists, who are at the forefront of developing novel sensing platforms, to engineers with cutting-edge integration concepts, to biologists/clinicians with highly impactful application areas that demand new sensing systems. Research themes that will be discussed in this GRC include: 1) novel recognition elements and reporters, 2) recent advances in optical, electrochemical, and mechanical detection, 3) real-world applications including in vivo sensing, 4) the use of nanotechnology to advance the understanding of molecular interactions and integration into sensor designs enabling novel applications, and 5) system integration technologies. Specific topical areas that will be covered include (but are not limited to), single molecule-based sensing, intracellular sensing, biomaterials with enhanced optical or electronic properties, nanomaterials, nanostructures, engineered surfaces, miniaturization and automation, and multiplexed detection in complex matrices. This GRC will also provide for informal discussions on funding opportunities in the area of bioanalytical sensors and strategies for the commercialization of new platform technologies.
The collegial atmosphere of this GRC with ample time for discussion during the oral sessions as well as opportunities for discussions during informal gatherings in the afternoons and evenings provides an avenue for scientists/engineers from diverse disciplines to brainstorm and promote new cross-disciplinary collaborations in the various research areas represented.
In addition, the Gordon Research Seminar (GRS) will convene immediately preceding the GRC (15 – 16 June 2012). Organized and conducted by graduate students and postdocs, the GRS will provide an opportunity for junior scientists to present their work in a formal and oral or poster format in front of their peers. These students will participate in the subsequent Bioanalytical Sensors GRC providing a unique opportunity to promote interactions between future researchers and established ones.

Tuesday, 6 March 2012

Just Published: Talanta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Talanta
Selected papers from the latest issue:

Multiresidue analysis of aromatic organochlorines in soil by gas chromatography-mass spectrometry and QuEChERS extraction based on water/dichloromethane partitioning. Comparison with Accelerated Solvent Extraction

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 3 March 2012
Florent Rouvière, Audrey Buleté, Cécile Cren-Olivé, Carine Arnaudguilhem
A novel multiresidue method was developed for the simultaneous analysis of 34 organochlorines, including chlorobenzenes, chlorophenols, chlorinated hydrocarbons and chlorinated olefins, in soil by GC-MS, using a QuEChERS-based extraction. The conventional QuEChERS method was optimised and, for the first time, the use of a non miscible-water solvent was required. The method was compared to ASE extraction, versatile technique widely used for the soils’ extraction and QuEChERS-based method was shown to be the most efficient in terms of recoveries, simplicity and rapidity. For ASE, recoveries between 42 and 85% were obtained for the majority of the compounds. However, due to the high pressure, all volatile compounds were lost. In opposite, QuEChERS extraction allowed detection and quantification of all the compounds with recoveries between 60 and 100%. Moreover, no additional clean up by dispersive SPE on PSA was necessary, which allowed reducing the cost of the analysis.Performance of the method was assessed. The method was linear over the range of concentration of 10-5000 μg Kg. Precision, expressed as intra-day precision and inter-day variation was verified at three concentrations. Limits of detection were from 2 to 50 μg Kgand limits of quantification from 7 to 170 μg Kgfor the majority of the compounds (chlorobenzenes and chlorinated hydrocarbons and olefins), except for chlorophenols. The method was further applied to different soils coming from a contaminated industrial site, where a new environmental remediation process, using phytoremediation, was tested. The results showed that the method could be applied to any kind of soils (mineral or organic) and was appropriate to very volatile compounds which were not available with conventional technique.

Highlights

► Optimisation of QuEChERS method for the analysis of organochlorines and phenols ► Compared to ASE, the developed QuEChERS method is rapid and easy to use ► Better recoveries with QuEChERS-based method than ASE ► Contrary to conventional methods, no water elimination. Then, no loss of volatiles ► QuEChERS-based method provides clean extracts with few matrix effects

Enhanced fluorescence sensing of melamine based on thioglycolic acid-capped CdS quantum dots

03 March 2012, 22:45:49Go to full article
Publication year: 2012
Source: Talanta, Available online 2 March 2012
Guang-Li Wang, Huan-Jun Jiao, Xiao-Ying Zhu, Yu-Ming Dong, Zai-Jun Li
A sensitive and simple method for the determination of melamine (MA) was developed based on the fluorescence enhancement effect of MA for thioglycolic acid-capped (TGA-capped) CdS quantum dots (QDs). Under optimum conditions, a good linear relationship was obtained from 2.0 × 10to 5.0 × 10 M. The detection limit was 1.0 × 10 M, which was much lower than the safety limit (2.5 ppm in USA and the UK; 1 ppm for infant formula in China). The solution pH, the adding sequence of the buffer solution and MA and surface modifiers of CdS QDs greatly influenced the enhancement extent of MA for CdS QDs. The fluorescence enhancement was attributed to the surface passivation of the surface states of QDs by amine group of MA. The method was applied to detect MA in raw milk with satisfactory results. The proposed method manifested several advantages such as high sensitivity, short analysis time, low cost and ease of operation.

Highlights

► A highly sensitive “turn-on” sensor for melamine (MA) ► MA induced obvious fluorescence enhancement in acidic solutions ► Amine group of MA could passivate the surface effect ► The surface modifiers of CdS influenced the enhancement extent ► MA improved the sensitivity for copper (II) ion detection

Just Published: Vibrational Spectroscopy

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Vibrational Spectroscopy
Selected papers from the latest issue:

Infrared Spectroscopic Study of the Model Metal-Ligand-Antibody Systems: What Information on the Structure and Stability of Systems Can Be Obtained?

06 March 2012, 01:13:41Go to full article
Publication year: 2012
Source: Vibrational Spectroscopy, Available online 5 March 2012
Marie Reková, Pavel Matějka, Věra Jedináková-Křížová
In this study we investigated the possibility of using infrared spectroscopy for the characterization of the ligand (diethylenetriaminepentaacetic acid, DTPA) in various aqueous media (water and different buffers), the antibody (immunoglobulin G, IgG), the metal-ligand complexes (Y-DTPA and Lu-DTPA) and the metal-ligand-antibody conjugates (Y-DTPA-IgG and Lu-DTPA-IgG). The aim was to describe behaviour of individual components, and to find spectral markers of complexes and/or conjugates formation. The reason of the choice of Lu and Y was the potential use of their radionuclides to form radiopharmaceutical species for nuclear medicine. We performed kinetic measurements to describe the stability/instability of individual systems. Multivariate data analysis allowed finding out spectral regions related to different chemical processes. Hydrolysis effect of the diethylenetriaminepentaacetic acid dianhydride (cDTPAA) in water was confirmed in unbuffered aqueous solution. Nevertheless, the study of cDTPAA in various buffered media showed evident suppression of hydrolysis. Thus, appropriate buffers were selected as media for complexation reactions with Y and Lu. Characteristic marker bands of complexation were identified. Human IgG in phosphate buffer and its interaction with the metal-ligand complexes were studied. Observation of new bands, band shifts and intensity changes revealed formation of the metal-ligand-IgG conjugates together with a somewhat changed secondary structure of IgG. We demonstrated the possibility of vibrational spectroscopic monitoring of the preparation steps of the metal-ligand-antibody conjugates as potential radiopharmaceutical products.

Preparation and characterization of multicore SERS labels by controlled aggregation of cold nanoparticles

03 March 2012, 22:44:35Go to full article
Publication year: 2012
Source: Vibrational Spectroscopy, Available online 3 March 2012
Isabel Freitag, Ute Neugebauer, Andrea Csaki, Wolfgang Fritzsche, Christoph Krafft, ...
The preparation and characterization of multicore labels for surface enhanced Raman scattering (SERS) at 785 nm excitation are described. These labels consist of gold nanoparticles whose aggregation was controlled by a diamine. SERS reporters were attached that contain sulfur groups for covalent conjugation to the gold surface and aromatic ring structures for distinct Raman signatures. A thin silver layer was deposited onto aggregated gold nanoparticles to further enhance the SERS signals. Two polymers were deposited to prepare the surface for encapsulation by silica and stabilize nanoparticles. The thickness of the silica layer depended on ammonia concentration and was determined by transmission electron microscopy. Treatment with APTMS provided amino groups for subsequent conjugation with antibodies. N-H bending vibrations of amino silane were detected by infrared spectroscopy. Functionalization of the silica coated multicore labels by a FITC labeled antibody was confirmed by fluorescence microscopy. A Zetasizer determined an average radius of 60 nm. SERS spectra of labels with three different reporters and a SERS spectrum of mixed labels with exposure time between 10 ms and 1 s demonstrated the high sensitivity and multiplexing capacity. This design of multicore labels offers 785 nm near-infrared excitation for reduced laser-induced cell degradation, size above 100 nm for low toxicity under in vivo investigations as reported elsewhere, high stability due to silica encapsulation, and capability of antibody binding. These biocompatible properties make multicore labels with different reporters a promising candidate for diagnostic applications.

Thickness measurement of thin polymer films by total internal reflection Raman and attenuated total reflection infrared spectroscopy

02 March 2012, 00:03:16Go to full article
Publication year: 2012
Source: Vibrational Spectroscopy, Available online 1 March 2012
Antti O. Kivioja, Anna-Stiina Jääskeläinen, Ville Ahtee, Tapani Vuorinen
For the first time total internal reflection (TIR) Raman spectroscopy was utilized for thickness measurements of thin isotropic polystyrene films on polypropylene substrate. In the presented method, the band intensity ratios of polystyrene to polypropylene were defined from the spectra, and the film thicknesses in a range from 50 nm to 350 nm were calculated mathematically from these ratios. The quantitativeness of the method was validated by applying the same principle to attenuated total reflection infrared (ATR-IR) spectroscopy and comparing the results to values obtained by ellipsometry and a spin-coating model. The results showed that the novel and non-invasive TIR Raman method reveals the film thickness quantitatively, and the method is applicable for thin films on soft substrates with similar refractive indices

Isothermal melt crystallization behavior of neat poly(L-lactide) (PLLA) and PLLA/organically modified layered silicate (OMLS) nanocomposite studied by two-dimensional (2D) correlation spectroscopy

02 March 2012, 00:03:16Go to full article
Publication year: 2012
Source: Vibrational Spectroscopy, Available online 1 March 2012
Yohei Ando, Harumi Sato, Hideyuki Shinzawa, Masami Okamoto, Isao Noda, ...
Isothermal melt crystallization behavior of neat poly(L-lactide) (PLLA) and PLLA/organically modified layered silicate (OMLS) nanocomposite was studied by using time-dependent infrared (IR) spectroscopy and transmission electron microscopy (TEM). Sets of time-dependent IR spectra reflecting the crystallization from the melt of the neat PLLA and PLLA/OMLS nanocomposite were collected at 105 °C. Fine details of the crystallization behaviors were analyzed by two-dimensional (2D) correlation spectroscopy, and significant differences in the crystallization behaviors depending on the presence of OMLS were revealed. Namely, it was found that the crystalline lamellae of the PLLA nanocomposite grow along the layered silicate, while the orientation of the neat PLLA resulted in more disordered orientation because of the absence of the OMLS. The result derived from the 2D correlation analysis of the time-dependent IR spectra of PLLA samples showed good agreement with corresponding TEM images.