World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Wednesday, 2 May 2012

Just Published: Sensors & Actuators A: Physical


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Fiber Bragg grating-tuned feedback laser flow sensor system

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Kyung-Rak Sohn
In this paper, a fiber Bragg grating (FBG) air flow sensor system using an all-fiber feedback laser is proposed. The operating principle of the feedback laser is based on the mode-locking mechanism between a Sagnac loop multi-grid filter and a tunable FBG <!-- no-mfc -->sing<!-- /no-mfc -->le-wavelength filter. A shift in the lasing wavelength is attributed to the change in the heat energy of the coil heater. This is because the flow sensor depends on the variations in the heat energy of the coil heater surrounding the FBG, thereby causing a shift in the Bragg wavelength owing to a thermo-optic effect. In order to investigate the spectral response as a function of the flow speed of air, a simple and cost-effective intensity-based demodulation technique using a micro-optic band-pass filter is demonstrated. The flow sensitivity of the sensor system was 0.7dB/(l/min) within a linear region.

Design and fabrication of SMS fiber refractometer for liquid

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
R.X. Gao, W.J. Liu, Y.Y. Wang, Q. Wang, F. Zhao, S.L. Qu
Single-mode/multi-mode/single-mode (SMS) fibers are optimally designed and fabricated as high sensitivity (∼4.6×10−6) refractometer sensors for liquid. It is shown that the width of multimode fiber is a key factor in the performance of as-fabricated refractometer sensor, which can be effectively controlled in the fabrication process by monitoring the output power of SMS fiber during wet acid etching process. The experimental results match quite well with the numerical simulation results. As-fabricated refractometer sensor shows promising potential applications in precisely monitoring the refractive index of liquid in chemical and biomedical fields.

A GaAs MEMS for AFM and spin injection

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Steve Arscott, Emilien Peytavit, Dominique Deresmes, Thomas Dargent, Duong Vu, Alistair C.H. Rowe, Daniel Paget
We investigate the mechanical and electrical properties of tip-less, GaAs micro-cantilevers on silica supports that are fabricated using a novel assembly approach. The resulting device is compatible with an atomic force microscope (AFM) and takes advantage of the electronic and optical properties of GaAs as well as the mechanical properties of silica. Mechanically, their resonant frequency and quality factor, as well as their AFM imaging capabilities (lateral resolution ∼10–20nm), are comparable to commercial silicon cantilevers despite the absence of micromachined tip. In the same AFM-like configuration, they can also function as novel spin-polarized electron injectors under excitation by a circularly polarized laser from the rear. Surface nitridation of the cantilever and deposition of a hydrophobic thin polymer film on the sample surface are found to stabilize the injected photocurrent, making them potentially useful for a variety of fundamental and applied investigations in atmosphere.

A review of tactile sensing technologies with applications in biomedical engineering

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Mohsin I. Tiwana, Stephen J. Redmond, Nigel H. Lovell
Any device which senses information such as shape, texture, softness, temperature, vibration or shear and normal forces, by physical contact or touch, can be termed a tactile sensor. The importance of tactile sensor technology was recognized in the 1980s, along with a realization of the importance of computers and robotics. Despite this awareness, tactile sensors failed to be strongly adopted in industrial or consumer markets. In this paper, previous expectations of tactile sensors have been reviewed and the reasons for their failure to meet these expectations are discussed. The evolution of different tactile transduction principles, state of art designs and fabrication methods, and their pros and cons, are analyzed. From current development trends, new application areas for tactile sensors have been proposed. Literature from the last few decades has been revisited, and areas which are not appropriate for the use of tactile sensors have been identified. Similarly, the challenges that this technology needs to overcome in order to find its place in the market have been highlighted.

Biosensor platform based on stress-improved piezoelectric membrane

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Xu Lu, Qiushi Guo, Zhuo Xu, Wei Ren, Z.-Y. Cheng
A new design as piezoelectric membrane is introduced to improve the performance of a diaphragm based biosensor platform. In the design, stress is introduced into the diaphragm by a vacuum chamber and makes it work as membrane with a higher sensitivity and a higher Q factor. The mass sensitivity of stress-improved membrane was investigated and an effective mass approach is used to simulate the sensitivity of the device for a point mass load. Piezoelectric membranes with different sizes have been built using PVDF piezo-polymers. These devices were characterized in air and in water. The experimental results are consistent with the theoretical simulation and indicate that the device in liquid can have a higher Q factor than that in air. A theoretical model, which is a sphere executing translatory oscillations in viscous fluid, was used to analyze the Q factor in liquid environment. The results indicated that the large Q factor in liquid can be attributed to the relative large effective mass of membrane in liquid environment.

Responsivity and noise of a wire-bonded CMOS micro-fluxgate sensor

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Chih-Cheng Lu, Yu-Ting Liu, Fang-Yu Jhao, Jen-Tzong Jeng
This paper presents a dual-core (Vacquier-type) micro-fluxgate magnetic sensor fabricated on a silicon chip based on standard CMOS technology. The silicon chip is 2.5mm×2.5mm in dimension, and the micro-fluxgate sensor occupies the area of 2.5mm×1.8mm. The sensor consists of magnetic cores, planar pick-up coils, bottom excitation coils (CMOS Al interconnections) and upper excitation coils (wire-bonding Al wires). The micro-solenoid excitation coils consisting of aluminum bonding wires and CMOS metallic layers can generate out-of-phase excitation magnetic fields strong enough to saturate the two magnetic cores. It was found that the sensor's sensitivity can be optimized and the field noise spectral density can be minimized by adjusting the excitation current as well as the excitation frequency. The maximum responsivity of 8.1V/T occurs at the second harmonic when the excitation frequency is 110kHz; however, the minimum magnetic field noise is found to be 2.6nT/√Hz at 1Hz under 20-kHz excitation. In comparison with other miniature planar fluxgates with similar dimensions reported to date, our device has a relatively low field noise spectral density.

Low-humidity sensing properties of PAMAM dendrimer and PAMAM–Au nanoparticles measured by a quartz-crystal microbalance

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Pi-Guey Su, Wen-Hau Tzou
Low-humidity sensing performance of generation 1 amine terminated polyamidoamine (PAMAM) dendrimer (G1-NH2), generation 5 amine terminated PAMAM dendrimer (G5-NH2) and G5-NH2–Au nanoparticles (G5-NH2–AuNPs) thin films were investigated by using a quartz crystal microbalance (QCM). The formation of AuNPs was characterized by UV–vis spectrophotometer. The characterizations of the thin films were analyzed by atomic force microscopy (AFM). Water vapor molecules adsorbed onto the G5-NH2–AuNPs thin film had a larger frequency shift than the G1-NH2 and G5-NH2 thin films. Adsorption dynamic analysis, molecular mechanics calculation (association constant), was applied to elucidate how number of amine surface functional groups of PAMAM dendrimer and doped AuNPS in PAMAM dendrimer increase the sensitivity to low-humidity.

Thick film resistors on stainless steel as sensing elements for strain sensor applications

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Zongyang Zhang, Min Jin, Sheng Liu
In this paper, thick film resistors (TFRs, R8241, Heraeus) on 430 stainless steel (SS) substrate for strain sensor applications are investigated. TFRs are screen printed and fired on dielectrics-on-430SS substrate by thick film technology. Microstructure analysis shows that no interaction or evidence for new phase can be detected at the interface between TFRs and dielectrics-on-430SS, which indicates the compatibility of the dielectrics and TFRs. Further experiments also show the excellent insulativity and robust bonding between the dielectrics layer and 430SS substrate. Meanwhile, temperature coefficients of resistivity (TCRs), gauge factors (GFs) and noise indices (NI) of TFRs are measured. Finally, thick film technology based steel pressure sensors (SPS) are fabricated by screen printing and firing four TFRs on a machined circular diaphragm and then the TFRs are connected in a Wheatstone bridge configuration. Preliminary tests show that the sensors exhibit a sensitivity of 4.68mV/V full-scale (FS) with 0.1% FS linearity and 0.15% FS hysteresis and 0.15% FS repeatability. Moreover, the thermal zero drifts and thermal sensitivity drifts of the sensors in the whole temperature range (−40°C to +125°C) are less than 2.5% FS.

A polymer foil non-contact IR temperature sensor with a thermoresistor integrated on the back of a vertically configured thermopile

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Fang Mao, Mikael Lindeberg, Klas Hjort, Lena Klintberg
A very thin non-contact IR temperature sensor has been fabricated in a polymer foil. A thermoresistor was placed in the isothermal back-layer of a vertical configured IR-sensor. The IR-sensor is a thermopile consisting of through-the-foil thermocouple legs in a flexible polyimide foil, and the integration of a thermoresistor to one of its surfaces enables use of the sensor for non-contact temperature measurements. The size of the sensor is 3mm×3mm and the thickness is less than 0.2mm. The sensor can easily be surface mounted to printed circuit boards. An ion track technique followed by lithographically controlled electroplating of nanowires and thin film deposited interconnects are used to fabricate the infrared sensor. The thin film nickel thermoresistor was fabricated using evaporation. Layers of Parylene C was used for electric insulation and protection to improve environmental stability. In the temperature range of 20–55°C, the thermoresistor shows good linearity. Some initial decrease in resistance was seen at 105°C whereafter the resistance stabilized. The IR temperature sensor was characterized, and for temperatures near room temperature a simple linear equation using the voltage response and temperature of the thermoresistor as the only input parameters was curve fitted to the experimental data. The difference between the measured and the calculated object temperature is less than 0.5°C using a confidence level of 95%.

Flexible microfluidic normal force sensor skin for tactile feedback

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Ruben D. Ponce Wong, Jonathan D. Posner, Veronica J. Santos
Robotic applications often require robust tactile sensing capabilities on curved surfaces, such as artificial fingertips. Flexible tactile sensors could be conformally wrapped around curved digits and could enhance grip by cushioning impacts and increasing the effective contact area during grasp. Flexible microfabricated devices that use thin film or solid electrical components are susceptible to failure due to cracking and fatigue. Conductive fluids have been used as transduction media, electrical connections, and in resistance-based pressure and bend sensors. In this work, a flexible and multilayer capacitive microfluidic normal force sensor is developed with a 5×5 taxel array. The sensor uses liquid metal-filled microfluidic channels as the capacitive plates and conductive interconnects. The sensor is microfabricated using soft lithography microfabrication techniques and consists of multiple layers of PDMS microchannels filled with the liquid metal alloy Galinstan and air pockets that modify the mechanical and electrical properties of the sensor. A single taxel is calibrated for normal forces ranging from 0 to 2.5N, is shown to provide repeatable measurements of static uniaxial loads, and follows the loading and unloading phases of low-frequency dynamic loads (0.4–4Hz). The sensor prototype has a spatial resolution on the order of 0.5mm, performs reliably when wrapped around a surface having a curvature similar to that of a human finger (1.575cm−1), and has been shown to tolerate curvatures as high as 6.289cm−1. The deformable liquid capacitive plates and heterogeneous PDMS-air dielectric medium can be designed to tune the sensor's sensitivity and range. The sensor prototype provides greater sensitivity at low loads, a feature which can be exploited for robotic applications in which light touch is important.

Investigation on standing wave vibration of the imperfect resonant shell for cylindrical gyro

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Xiang Xi, Yulie Wu, Xiaomei Wu, Yi Tao, Xuezhong Wu
Standing wave vibration is the basic working mode for most vibratory shell gyros. In this paper, the standing wave vibration of the imperfect resonant shell for cylindrical gyro is investigated. The stability of the vibration is analyzed by building the imperfect ring model. Theoretical result shows that the offset of the vibration axis, which gives rise to the zero bias of the gyro, is affected synthetically by the frequency split, exciting force and damping coefficient. FEM simulation is employed to give a study of the vibration process of the imperfect shell. In addition, the factors which may affect the offset of the standing wave vibration are analyzed quantitatively. Experiments were set up to validate these influence factors by using vibration measurement equipments. Experimental results show that the frequency split affects the vibration offset significantly. The exciting force and damping coefficient have slight effect on the standing wave vibration. Simulated and measured results are in close agreement.

Geomagnetic sensors based on Metglas/PZT laminates

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
D.T. Huong Giang, P.A. Duc, N.T. Ngoc, N.H. Duc
A potential geomagnetic-field sensor is proposed on the basis of an optimal 2D configuration of magnetoelectric Ni-based Metglas/PZT laminates. This sensor can perfectly serve to measure both the strength and the orientation of the earth's magnetic field. An incredibly high ME-voltage response of 0.871V/Oe to the geomagnetic field with a resolution of 3×10−4 Oe has been achieved for composite laminates with a size of 15mm×1mm. With respect to the field inclination, an angular sensitivity of 3.86×10−3 V/degree and an angular resolution of 10−1 degree have been determined. This simple and low-cost magnetic-field sensor is promising for applications not only as novel smart compasses and in global positioning devices, but also as magnetic biosensors.

Carbon nanotube polymer coatings for textile yarns with good strain sensing capability

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Rui Zhang, Hua Deng, Renata Valenca, Junhong Jin, Qiang Fu, Emiliano Bilotti, Ton Peijs
In this study, a commercially available Spandex multifilament yarn was coated with a thermoplastic polyurethane/carbon nanotube (TPU/CNT) conductive polymer composite (CPC), and conductive elastic yarns with good strain sensing ability were achieved with equivalent CNT concentrations as low as 0.015wt.%. The resistance per meter coated yarn decreased with increasing CNT concentration in the CPC coating, while in the case of a homogeneous coating, the CPC concentration in the coating solution did not have a significant effect on the resistance per meter coated yarn. Upon cyclic loading, the strain sensing behaviour showed partial recovery of resistance in the first loading cycle, while good reversibility was observed a number of cycles, giving these materials good potential as sensors for smart textiles.

Magnetic flux vertical motion modulation for 1/f noise reduction of magnetic tunnel junctions

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Mengchun Pan, Jiafei Hu, Wugang Tian, Dixiang Chen, Jianqiang Zhao
Magnetic tunnel junctions (MTJs) have larger magnetoresistance ratio and higher magnetic sensitivity than other magnetoresistive structures, whereas their 1/f noise is also larger. To reduce the 1/f noise and improve the low frequency detection capability of MTJ sensors, some magnetic flux modulation schemes based on MEMS flux concentrators have been put forward, and several prototypes with gap-changed modulation (GCM) were fabricated by Army Research Laboratory (ARL). Presently, the problem of low magnetic modulation efficiency in GCM is still an obstacle for MTJ sensors with a resolution of pico-Tesla. In this paper, a novel magnetic flux modulation called vertical motion modulation (VMM) is proposed. In VMM, a modulation film driven by a MEMS actuator vibrates vertically above the air gap of the flux concentrator and the MTJs in the air gap detect an AC magnetic field with a DC bias. Theoretically the modulation efficiency of VMM can exceed 30% when the air gap varies from 30μm to 70μm. A preliminary prototype sensor with VMM was fabricated and its modulation efficiency achieves 17.4%. It is expected that the modulation efficiency of MTJ magnetic sensors with VMM can surpass 30% through modifying the sizes and improving the magnetic permeability of modulation films.

Gas sensing properties of RF magnetron sputtered MgIn2O4 thin films

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
B. Anuradha, C. Sanjeeviraja
MgIn2O4 thin films have been deposited on glass substrates by RF magnetron sputtering technique and their sensing characteristics were investigated in this study. The experimental results showed that the MIO exhibited high sensitivity and selectivity for the detection of ethanol. The gas-sensitive behavior of RF sputtered MIO thin films can be altered by varying the fabrication parameters like the sputtering power, substrate temperature. In particular, the sensitivity can be increased. The thickness of MIO films was measured by Mitutoyo SJ-301 surface roughness tester. The morphology, composition and crystal structure were investigated by using SEM, EDAX and XRD. Hall measurements showed n-type conductivity with electron mobility value 6.9cm2/(Vs) and carrier concentration of 1.40×1018 cm−3.

Direct analog-to-microcontroller interfacing

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Lars Bengtsson
This paper will demonstrate how signals from analog sensors can be directly interfaced to any digital embedded system even though they may not be equipped with an on-chip ADC (Analog-to-Digital Converter), comparator or OP amp (Operational Amplifier). With only two resistors and one capacitor, we will present a solution that allows analog voltages to be measured directly using only a few digital I/O-pins. The digital target system requirements are minimized and limited to only two digital I/O-pins (with tri-state capability). No ADC, comparators, timers or capture modules are necessary. The extremely modest hardware requirements make it a suitable solution also for CPLDs/FPGAs (Complex Programmable Logic devices/Field Programmable Gate Arrays). Since this solution will allow even the simplest embedded system to be interfaced to analog voltage sensors, it has the potential of reducing design costs considerably. The proposed design is for DC or low-frequency signals and compared to other similar solution, this design needs no embedded analog blocks at all.

The synthesis of poly(vinyl cinnamates) with light-induced shape fixity properties

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Haiyan Du, Junhua Zhang
Poly(vinyl cinnamates) (PVCi) with different degrees of substitution (DS) are synthesized by esterifying hydroxyl of poly(vinyl alcohol) (PVA) with carboxyl of p-chloro-substituted cinnamic acid. The grafted polymer has photosensitive property and presents photocrosslinking due to the photodimerization between pendant cinnamate groups, which affords PVCi sample photo induced shape fixity properties. That is to say PVCi sample having original shape could be deformed into a temporary shape under extra load followed by irradiating it under ultraviolet (UV) light of 360nm. What interesting is the shape fixity has strong relationship with DS. Unfortunately, the deformed sample cannot recover its original shape under UV light of 254nm. The reason behind the macroscopic shape change has been studied. And the effect of DS on the grafted polymer structure and properties has been studied by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and UV spectra.

PMN-PT–PZT composite films for high frequency ultrasonic transducer applications

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Hsiu-Sheng Hsu, Vatcharee Benjauthrit, Fan Zheng, Rumin Chen, Yuhong Huang, Qifa Zhou, K. Kirk Shung
We have successfully fabricated x(0.65PMN-0.35PT)–(1− x)PZT (xPMN-PT–(1− x)PZT), where x is 0.1, 0.3, 0.5, 0.7 and 0.9, thick films with a thickness of approximately 9μm on platinized silicon substrate by employing a composite sol–gel technique. X-ray diffraction analysis and scanning electron microscopy revealed that these films are dense and creak-free with well-crystallized perovskite phase in the whole composition range. The dielectric constant can be controllably adjusted by using different compositions. Higher PZT content of xPMN-PT–(1− x)PZT films show better ferroelectric properties. A representative 0.9PMN-PT–0.1PZT thick film transducer is built. It has 200MHz center frequency with a −6dB bandwidth of 38% (76MHz). The measured two-way insertion loss is 65dB.

Characterization of inverted pyramidal hollow cathode microplasma devices operating in reactive gases for maskless scanning plasma etching

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Li Wen, Zhen Yuan, Leili Cheng, Hai Wang, Jiaru Chu
In the cantilever-based microplasma etching system proposed by our group, the stable discharge characteristics of microplasma device in reactive gases is the foundation of the maskless scanning etching of material. In this paper, the cantilever probe integrated with 100μm2 inverted pyramidal hollow cathode microplasma device and nano-aperture at the hollow tip is successfully fabricated. The electrical and optical characteristics of the dc-driven microplasma devices operating in SF6, CHF3 reactive gases and their mixtures with Ar at different gas pressure are investigated. The etching profile and etching rate for silicon in SF6 microplasma exported from the nano-aperture are simulated to predict the etching effect under maskless microplasma etching system. The results of this paper may lay a foundation for upcoming experiments of maskless scanning plasma etching of silicon and its compounds, and also have implications in microplasma material processing in reactive gases using other devices configuration.

Power-generation performance of lead-free (K,Na)NbO3 piezoelectric thin-film energy harvesters

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Isaku Kanno, Tomoharu Ichida, Kazuhiko Adachi, Hidetoshi Kotera, Kenji Shibata, Tomoyoshi Mishima
We fabricated piezoelectric energy harvesters with lead-free (K,Na)NbO3 (KNN) thin films and compared their power-generation performance with that of Pb(Zr,Ti)O3 (PZT) thin film energy harvesters. The KNN and PZT thin films were deposited on Pt/Ti/Si substrates by rf-magnetron sputtering. The transverse piezoelectric properties of the KNN and PZT films were essentially the same, e 31,f ∼−11C/m2. The peak average output power of the unimorph cantilevers of KNN/Si and PZT/Si were 1.1 and 1.0μW, respectively. Thus, the performance of lead-free KNN thin films as a piezoelectric energy harvester is comparable to that of PZT films.

Frequency-tunable soft composite antennas for wireless sensing

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Qing-Yuan Tang, Yong-Mei Pan, Y.C. Chan, K.W. Leung
In this study, flexible and uniform multiwall carbon nanotube embedded polydimethylsiloxane (PDMS) sheets were prepared using a vacuum filtration and transfer process. The resistance of the sheets and microstructures were investigated for the fabrication of ideal probe-fed and microstrip-fed patch antennas. Simulation results showed that the resonance and gain of an antenna were affected by the conductivity of the patch significantly. The return loss and gain are acceptable when a conductivity of 105 S/m is used. The stretchability test indicated that a gold-coated sheet was more stable than a pristine sheet. Its resistance has a change of 0.5% only, with a displacement of 2500μm. The frequency-tuning capability was demonstrated using an air inflatable microstrip-fed patch antenna. The working frequency can be tuned by 6.5% with a displacement of 1500μm, which was higher than that of previously reported MEMS bridge and electrostatic force tunable antennas. This is the first time that a frequency tunable antenna fabricated by PDMS/carbon nanotube is reported. The optimization methods for this type of antenna are discussed and some potential applications such as remote wireless pressure sensors are proposed.

Temperature-sensitive chemical cell based on Nickel (II) phthalocyanine-tetrasulfonic acid tetrasodium salt

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Zubair Ahmad, Shahino Mah Abdullah, Khaulah Sulaiman
An organic compound Nickel (II) phthalocyanine-tetrasulfonic acid tetrasodium salt (NiTSPc) has been studied as a potential material for a solution based temperature sensor. Using NiTSPc, an ITO/NiTSPc solution/ITO chemical cell has been made and characterized in the temperature range of 20–85°C. This sensor works on the principle of change in the resistance and capacitance of the chemical cell caused by the temperature variation. Good response/recovery and small hysteresis have been attained. The proposed sensor is aimed to evolve towards highly sensitive organic temperature sensor in a specific temperature range.

A compact dielectric elastomer tubular actuator for refreshable Braille displays

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
P. Chakraborti, H.A. Karahan Toprakci, P. Yang, N. Di Spigna, P. Franzon, T. Ghosh
Electroactive polymer actuators stimulated by appropriate levels of electric field are particularly attractive for human-assist devices such as Braille. The development of a full page refreshable Braille display is very important for the integration of the visually impaired into the new era of communication. In this paper, development of a compact dielectric elastomer actuator suitable for Braille application is reported. The actuators are fabricated from commercially available silicone tubes. The tube has been rendered mechanically anisotropic through asymmetric levels of applied pretension in circumferential and axial directions in order to direct the actuation strain in the axial direction of the actuator. Key performance parameters, such as displacement, force, and response time of the actuator are investigated. The test results demonstrate the potential of the compact, lightweight, and low cost dielectric elastomer as actuators for a refreshable full page Braille display.

RF/baseband co-design of switching receivers for multiband microwave energy harvesting

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Alessandra Costanzo, Aldo Romani, Diego Masotti, Nicola Arbizzani, Vittorio Rizzoli
The paper addresses a new integrated design of RF/Microwave receivers and conversion systems for energy harvesting to be adopted in ultra-low power density environments. Such systems can be very useful in typical humanized scenarios in the presence of existing wireless systems with power densities as low as a few μW/cm2. Despite of the scarce RF power available, energy usable to extend battery life or to self-power low-duty cycle electronics may be scavenged by highly efficient receivers and power converter circuits designed in a unique design process. A multi-band antenna is used as the RF power receiver. Its rigorous frequency-dependent equivalent circuit in the presence of incident fields, simultaneously radiated in several bands, is used in the joint design of a rectifier stage and of a boost converter that can dynamically track the maximum power point. This is obtained by a new simulation platform combining SPICE-like time-domain models of dispersive multiport components with the transient analysis of the storage and control sub-systems. The system operation is fully measured in a practical application and predicted and measured stored energy and system efficiency are discussed. As preliminary results the converter is realized by discrete components, but a significant reduction in power consumption is expected by an integrated circuit design.

Electrostrictive bending actuators: Modeling and experimental investigation

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Mickaël Lallart, Claude Richard, Pisan Sukwisut, Lionel Petit, Daniel Guyomar, Nantakan Muensit
Electroactive polymers (EAPs) have become of great interest for energy conversion because of their flexibility, manufacturability and low production cost. Hence, such materials present promising application potentials in the fields of actuation (e.g., artificial muscles, micropumps, …). The purpose of this paper is to present the modeling of devices using EAPs in quasi-static flexural solicitations. Based on the mechanical and electromechanical analyses of a structure equipped with such materials, the actuation abilities of such systems will be assessed. In order to illustrate the proposed principles, the approach will be applied to two particular structures consisting in a cantilever beam and a clamped–clamped beam with the active material in the middle.

Design and characterization of miniature piezoelectric generators with low resonant frequency

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Ziping Cao, Jinya Zhang, Hiroki Kuwano
In this study, both materials selection and device configuration design were considered for developing miniature piezoelectric generators with low resonant frequency. Instead of single crystal Si, stainless steel (SUS) was chosen as the substrate of AlN thin films owing to its higher fracture toughness, which made it possible that millimeter-scale generators had resonant frequency of less than 100Hz. The device configuration including the aspect ratio (the length of the cantilever to the width of the cantilever) and the thickness ratio (the substrate layer to the AlN film layer) were analyzed for optimizing transverse electromechanical coupling coefficient of generators. Using AlN thin films deposited on stainless steel, millimeter-scale generators were fabricated and their vibration energy harvesting performance was characterized. Output power and resonant frequency of the devices are, respectively, 5.130μW and 69.8Hz when they were vibrated at 1g acceleration and connected with 0.7MΩ electric loading.

A model for the energy harvesting performance of shear mode piezoelectric cantilever

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
L. Zhou, J. Sun, X.J. Zheng, S.F. Deng, J.H. Zhao, S.T. Peng, Y. Zhang, X.Y. Wang, H.B. Cheng
The electrical model with the piezoelectric constitutive equations of d 15 mode and the single degree of freedom model are combined to describe the energy harvesting performance of shear mode piezoelectric cantilever, and the proposed model is used to simulate the frequency dependence of the output peak voltage and power. To verify the validity, the previous experimental parameters of the shear mode piezoelectric cantilever with 0.71Pb(Mg1/3Nb2/3)O3–0.29PbTiO3 single crystal and brass shim are chosen to evaluate the energy harvesting performance as the example, and the frequency dependence of the output peak voltage and output power is in good agreement with the previous experiment. The results are also compared with the ANSYS numerical solutions, which reveal acceptable agreement. The effects of the material properties and geometrical dimensions on the energy harvesting performance are discussed to provide some useful guidelines to the design of piezoelectric energy harvesting devices.

Large stroke and nanometer-resolution giant magnetostrictive assembled actuator for driving segmented mirrors in very large astronomical telescopes

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Bin-tang Yang, De-hua Yang, Peng-you Xu, Yu-dong Cao, Zhi-qiang Feng, Guang Meng
High-precision-positioning technology with nanometric resolution plays a vital role in driving segmented mirrors in very large astronomical telescopes (VLAT). Current positioning actuators in VLAT are generally based on hydraulic technology, flexible-hinge principle and motor-reducer approaches. Although these actuators have their own merits in their specific applications, they cannot satisfy the high-precise-positioning requirements in active and adaptive optics because of their inherent drawbacks such as hydraulic leakage, lagging, solid friction and insufficient accuracy. To improve the performance of actuators and meet the needs for positioning resolution and accuracy in active and adaptive optics in VLAT, this paper presents the design and implementation of a giant magnetostrictive assembled actuator (GMAA). The actuator features stable nano-resolution positioning, large stroke, instant response, and high load capacity. The design is based on a combination of dual level, i.e. coarse and fine drive regimes. A new large stroke, nanometric positioning GMAA is realized. In this paper the integrated design of the actuator, the control system and the test results from the prototype are presented. The test results prove not only the capacity and positioning accuracy of the actuator in large strokes, but also the effectiveness of the control system and the control method. The tests performed on a single GMA show that when its stroke is 0.6mm, its positioning accuracy may reach to ±30nm and the GMAA positioning accuracy may reach up to ±90nm. The tests performed on the entire GMAA verify that it is able to perform a stroke of 2.2mm with approximately 60nm of displacement resolutions when 600N of external load is applied.

A new acoustic transducer with a pressure-deformed piezoelectric diaphragm

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Andrew S. Wixom, Michael J. Anderson, David F. Bahr, Dylan J. Morris
A new design for wide-band acoustic transducers is described. Radial tension is applied to a thin piezoelectric diaphragm with conductive electrodes on the upper and lower surface. One side of the diaphragm is pressurized, elastically deforming the diaphragm into a slightly curved shape. The in-plane static tension is modulated by applying a time-dependent voltage across the electrodes of the piezoelectric diaphragm. The tension modulation causes transverse displacement oscillations of the diaphragm. This actuation takes place in spite of the fact that the piezoelectric diaphragm does not contain a passive elastic layer, which is necessary for actuation by flexure in planar diaphragms. A theoretical quasi-static model using hexagonal symmetry for the piezoelectric material was developed to predict the electromechanical actuation mechanism, and the mode for optimal operation in non-resonant conditions. Piezoelectric diaphragms were fabricated from PVDF film of nominal thickness 40μm into circular diaphragms 1cm in diameter. For the pressure-deformed transducers fabricated from PVDF film, displacement amplitudes of 9–14.5nm/V were observed, and the maximum displacement amplitude took place at the applied tension and static pressure predicted by the model. Additional measurements with conventional flexure-type transducers containing a diaphragm consisting of a layer of PZT and a passive elastic material fabricated using MEMS processes were performed to compare with the transducers fabricated from PVDF film. The displacement amplitude per unit electric field measured for the transducers fabricated from PVDF film was comparable to those measured from conventional PZT flexure-type transducers, despite the fact that the piezoelectric coupling coefficient for PVDF was approximately 100 times smaller than that for PZT.

Effective hydraulic resistance of actuator nozzle generating a periodic jet

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
V. Tesař
Because of nonlinearity of characteristics of nozzles, their effective hydraulic resistance when generating periodically pulsating jet is higher than the steady-flow value. Author investigated this effect in experiments with a nozzle supplied with superposed steady flow and a pulsation generated by piston-type pulsator, and found deviations from the predictions based on mere nonlinearity. The disagreement is explained by fluid accumulation due to its compressibility in the actuator cavity upstream from the nozzle. Two mathematical models of the periodic accumulation processes were set up. The experimental data are located between the results of these models. The final outcome of this study is a law of universal validity for design of actuators with periodic flows in nozzles.

Nanoforce estimation based on Kalman filtering and applied to a force sensor using diamagnetic levitation

02 May 2012, 09:43:12
Publication year: 2012
Source:Sensors and Actuators A: Physical, Volume 179
Emmanuel Piat, Joël Abadie, Stéphane Oster
Nanoforce sensors based on passive diamagnetic levitation with a macroscopic seismic mass are a possible alternative to classical Atomic Force Microscopes when the force bandwidth to be measured is limited to a few Hertz. When an external unknown force is applied to the levitating seismic mass, this one acts as a transducer that converts this unknown input into a displacement that is the measured output signal. Because the under-damped and long transient response of this kind of macroscopic transducer cannot be neglected for time-varying force measurement, it is then necessary to deconvolve the output to correctly estimate the unknown input force. The deconvolution approach proposed in this paper is based on a Kalman filter that use an uncertain a priori model to represent the unknown nanoforce to be estimated. The main advantage of this approach is that the end-user can directly control the unavoidable trade-off that exists between the wished resolution on the estimated force and the response time of the estimation.

Gordon F. Kirkbright Bursary Award, 2013


The Gordon F. Kirkbright bursary award is a prestigious annual award that enables a promising student/non-tenured young scientist of any nation to attend a recognised scientific meeting or visit a place of learning.

The fund for this bursary was established in 1985 as a memorial to Professor Gordon Kirkbright in recognition of his contributions to analytical spectroscopy and to science in general. Although the fund is administered by the Association of British Spectroscopists (ABS) Trust, the award is not restricted to spectroscopists.

Applications are invited for the 2013 Gordon Kirkbright Bursary.

For further information contact John Chalmers at, email: vibspecconsult@aol.com

The closing date for entries is 31 December 2012.

Tuesday, 1 May 2012

Just Published:Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Chromatography A
Selected papers from the latest issue:

Sample displacement chromatography as a method for purification of proteins and peptides from complex mixtures

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Martina Srajer Gajdosik, James Clifton, Djuro Josic
Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method takes advantage of relative binding affinities of components in a sample mixture. During loading, there is a competition among different sample components for the sorption on the surface of the stationary phase. SDC was first used for the preparative purification of proteins. Later, it was demonstrated that this kind of chromatography can also be performed in ion-exchange, affinity and hydrophobic-interaction mode. It has also been shown that SDC can be performed on monoliths and membrane-based supports in both analytical and preparative scale. Recently, SDC in ion-exchange and hydrophobic interaction mode was also employed successfully for the removal of trace proteins from monoclonal antibody preparations and for the enrichment of low abundance proteins from human plasma. In this review, the principals of SDC are introduced, and the potential for separation of proteins and peptides in micro-analytical, analytical and preparative scale is discussed.

Visualisation of J-type counter-current chromatography: A route to understand hydrodynamic phase distribution and retention

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Yue Hugh Guan, Remco N.A.M. van den Heuvel, Ying-Ping Zhuang
This paper has addressed decade sought-after questions on phase bilateral distribution and stationary phase retention in any J-type high-speed counter-current chromatographic (CCC) centrifuge. Using a 2-D spiral column operated on such a CCC device and an aqueous two-phase system, this work systematically observed the phase interaction during transitional period and at dynamic equilibration under stroboscopic illumination. The experimental results thus obtained were used to examine the effects of the liquid–solid friction force, tangential centrifugal force, and physical properties of the two-phase system on hydrodynamic phase behaviour. We identified that (a) density difference between lower and upper phases is the critical factor to cause unusual phase bilateral distribution in the 2-D spiral column and (b) interfacial tension (manifested primarily as phase settling time) of any two-phase system is the critical factor in explaining inability to retain stationary phase in 3-D helical column and, for certain flow modes, in the 2-D spiral column. This work thus has extended or modified the well-established rule-of-thumb for operating J-type CCC devices and our conclusions can accommodate virtually all the anomalies concerning both hydrophobic and hydrophilic phase systems. To this end, this work has not only documented valuable experimental evidences for directly observing phase behaviour in a CCC column, but also finally resolved fundamentally vital issues on bilateral phase distribution orientation and stationary phase retention in 2-D spiral and 3-D helical CCC columns. Revised recommendations to end users of this technology could thus be derived out of the essence of the present work presumably following further experimental validation and a consensus in the CCC R&D and manufacturing circle.

High-throughput determination of adsorption equilibria for chromatographic oligosaccharide separations

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Sreekanth Chilamkurthi, Jan-Hein Willemsen, Luuk A.M. van der Wielen, Edwin Poiesz, Marcel Ottens
Adsorption equilibria of the saccharides d-glucose, d-galactose, l-arabinose, lactose and a sugar acid were measured on gel-type sulfonated poly (styrene-co-divinylbenzene) strong cation exchange resins in a high-throughput (HT) 96-well plate batch uptake mode using a pipetting robot at 25°C. Four different ionic forms, Ca2+, K+, Na+, and H+ were used. Single component adsorption isotherms were determined in a concentration range of 10–240mgml−1. Multicomponent experiments were performed to investigate competitive adsorption in a concentration range of 10–120mgml−1. A qualitative investigation on competitive and cooperative effects was performed. All sugar isotherms showed a linear behavior except for the sugar acid which showed an unfavorable (anti-Langmuir) behavior in the high concentration ranges. Selectivity values were determined from the binary mixture partition coefficient (K) values of each component. This HT 96-well plate batch uptake method proves to be less laborious and consumes less time and material compared to the frontal analysis and adsorption–desorption methods where column experimentation is used. Ternary mixture separation of arabinose and the sugar acid from glucose showed K+ and Ca2+ loaded resins having the best selectivity (DIAION Ca2+ 2.01 and 1.78 for l-arabinose/d-glucose and sugar acid/l-arabinose respectively), similarly Purolite K+ loaded resin for the lactose separation from glucose and galactose (1.17 for lactose/d-glucose). Column experiments were performed to validate the batch uptake experiments. The static binding results could easily be translated to the column experiments with good agreement. Finally, adding to the validity of the approach, binary and ternary fixed-bed experiments were well described by a dynamic mathematical chromatographic model using the parameters obtained from the binary-component isotherm data.

Impact of the limitations of state-of-the-art micro-fabrication processes on the performance of pillar array columns for liquid chromatography

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Jeff Op de Beeck, Wim De Malsche, Deniz S. Tezcan, Piet De Moor, Gert Desmet
We report on the practical limitations of the current state-of-the-art in micro-fabrication technology to produce the small pillar sizes that are needed to obtain high efficiency pillar array columns. For this purpose, nine channels with a different pillar diameter, ranging from 5 to 0.5μm were fabricated using state-of the-art deep-UV lithography and deep reactive ion etching (DRIE) etching technology. The obtained results strongly deviated from the theoretically expected trend, wherein the minimal plate height (H min) would reduce linearly with the pillar diameter. The minimal plate height decreases from 1.7 to 1.2μm when going from 4.80 to 3.81μm diameter pillars, but as the dimensions are further reduced, the minimal plate heights rise again to values around 2μm. The smallest pillar diameter even produced the worst minimal plate height (4μm). An in-depth scanning electron microscopy (SEM) inspection of the different channels clearly reveals that these findings can be attributed to the micro-fabrication limitations that are inevitably encountered when exploring the limits of deep-UV lithography and DRIE etching processes. When the target dimensions of the design approach the etching resolution limits, the band broadening increases in a strongly non-linear way with the decreased pillar dimensions. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100–200nm and when the target design size for the inter-pillar distance is of the order of 250nm, this inevitably leads to pores that will range in size between 50 and 450nm that we want to highlight with our paper highly non-linear relationship. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100–200nm and when the target design size for the inter-pillar distance is of the order of 250nm, this inevitably leads to pores that will range in size between 50 and 450nm.

A validated ultra-high performance liquid chromatography coupled to high resolution mass spectrometry analysis for the simultaneous quantification of the three known boar taint compounds

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
K.M. Bekaert, J. Vanden Bussche, S. François, F.A.M. Tuyttens, H.F. De Brabander, F. Vandendriessche, L. Vanhaecke
Boar taint is an off-odour that can occur when meat or fat from entire male pigs is heated. Most of the currently available analytical methods are not capable of detecting the three known boar taint compounds (indole, skatole and androstenone) simultaneously, which renders their analysis often labour-intensive and time-consuming as separate analyses are required. In this study a validated U-HPLC–HR-Orbitrap-MS analysis method is described for the quantitative determination of the three boar taint compounds in fat. The sample pre-treatment involves a melting step followed by extraction with methanol and clean-up consisting of a freezing step and solid phase extraction (HLB cartridges). The analytes are then chromatographically separated and detected with an Exactive™ high-resolution mass spectrometer. Due to the absence of guidelines for the analysis of boar taint in fat, the Commission Decision 2002/657/EC [18] and ISO 17025 [19] guidelines were used as guideline for validation of the developed detection method. This resulted in limits of detection and limits of quantification between 2.5 and 7μgkg−1 and between 5 and 10μgkg−1 for the three compounds, respectively, which is far below the threshold values set at 100μgL−1 for indole, 200μgL−1 for skatole and 1000μgL−1 for androstenone in pig fat samples. The method obtained for the three compounds a repeatability (RSD) lower then 12.7% and a within-laboratory reproducibility (RSD) lower than 16.9%. The recovery of the three compounds ranged between 99 and 112 and an excellent linearity (R 2 ≥0.99) was found. In the future, this method may be extended with other compounds that turn out to be correlated with boar taint.

Preparation and characterization of hybrid-silica monolithic column with mixed-mode of hydrophilic and strong anion-exchange interactions for pressurized capillary electrochromatography

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Xiao Wang, Yanqiong Zheng, Chunyuan Zhang, Yanzhong Yang, Xucong Lin, Guihua Huang, Zenghong Xie
A novel organic-silica hybrid monolithic stationary phase with a mixed-mode of hydrophilic and strong anion-exchange interactions (HI-SAX) was prepared with a modified “one-pot” process of functional monomers and alkoxysilanes. Using a hydrosoluble initiator 2,2′-azobis(2-methylpropionamidine) dihydrochloride (AIBA), the homogeneous prepolymerization system of this hybrid monolith was successfully obtained by a simple operation. The polycondensation of alkoxysilanes (tetramethoxysilane (TMOS) and vinyl-trimethoxysilane (VTMS)) and the in situ copolymerization of a quaternary ammonium group-containing acrylic monomer ([2-(acryloyloxy)ethyl] trimethyl ammonium methyl sulfate (AETA)) on the precondensed siloxanes were achieved. The morphologies of the hybrid-silica monolithic matrixes were observed by SEM, and the performances of the organic-silica hybrid monolithic columns were investigated by pressurized capillary electrochromatography. The mechanical stability and reproducibility of the obtained hybrid monolithic column preformed acceptable. Both hydrophilic interaction chromatography mechanism and strong anion-exchanged interaction were investigated. A mixed mode of HI-SAX was obtained for the analysis of nucleotides with a good resolution, and the separation of polar and basic nucleic acid bases and nucleosides was also achieved without peak tailing.

Hybrid monolithic columns with nanoparticles incorporated for capillary electrochromatography

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Wen Lei, Ling-Yi Zhang, Li Wan, Bian-Fang Shi, Yan-Qin Wang, Wei-Bing Zhang
The core–shell silica nanoparticles Fe3O4@SiO2/NH2, wormlike and hexagonal SBA-15 silica were incorporated into polymethacrylate monolithic columns containing butyl methacrylate (BMA) and ethylene dimethacrylate (EDMA), respectively to develop novel stationary phases with mixing mechanism of reverse phase and ion exchange. Experimental conditions including types of nanoparticles, dispersion pattern, nanoparticles concentration, column placement mode, and reaction temperature were optimized for simple and stable column preparation. The poly(BMA-EDMA-Fe3O4@SiO2/NH2) and poly(BMA-EDMA-SBA-15/NH2) (both wormlike and hexagonal shape nanoparticles) monolithic columns were evaluated with mixture of organic acids as sample in capillary electrochromatography (CEC) mode and the relative column efficiency reaches 290,000plates/m. The results indicate that the incorporation of nanoparticles with various shapes enhances both selectivity and column efficiency due to high specific surface area of nanoparticles and mixing separation mechanism. In addition, poly(BMA-EDMA-Fe3O4@SiO2/NH2) monolith capillary column was applied to separation of aqueous extract of rhizoma gastrodiae and showed great potential in the method development of complex samples.

Evaluation of lifetime and analytical performance of gas chromatographic inlet septa for analysis of reactive semivolatile organic compounds

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Jessica Westland, Kari Organtini, Frank L. Dorman
A comparison of septum degradation data obtained from a variety of standard GC septa, including the Thermogreen™ LB-2, AG3 (Green), Thermolite®, BTO® and the Merlin Microseal™ were evaluated. This study was conducted to determine analytical system lifetime between inlet maintenance based on chromatographic performance of reactive compounds as a function of septum aging through repeated injections. It is widely accepted that gas chromatographic septa degrade relative to the operating temperature of the injector and also based on the physical interaction with the syringe needle. This interaction may cause shedding of particles which then accumulate in the injection port liner, or possibly on the GC column in rare cases. This will likely lead to reactive compound breakdown in the injection port of flash-vaporizing inlets and thus reduce the amount of time that an instrument may be operated between inlet maintenance. Evaluations of the septa were based on the performance of the organochlorine compounds, endrin and 4,4′-DDT. These two compounds act as general indicators for the overall inertness of the GC injector, and their performance may be used to extrapolate to the performance of many other compounds. The average lifetime in terms of the number of injections for the studied septa was determined to range from 151 injections to nearly 2000 injections, depending on the septum. These values were found to be repeatable within the same septa material, or within class. The injection lifetime was found to be statistically different between different septa, however, indicating that not all septa are equivalent in terms of their durability to repeated injections. Additionally, some septa were found to predominately cause degradation of endrin, while others were found to cause reactivity of 4,4′-DDT, indicating that a difference in septa material may cause differences in what types of compounds become reactive in the GC inlet.

Determination of RNA degradation by capillary electrophoresis with cyan light-emitted diode-induced fluorescence

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1239
Tzu-Hsueh Yang, Po-Ling Chang
RNA integrity plays an important role in RNA studies because poor RNA quality may have a great impact on downstream methodologies. This study proposes a cost-effective, rapid, and sensitive method for determining RNA integrity based on capillary electrophoresis that utilizes a cyan light-emitted diode-induced fluorescence as a separation tool. The capillary was initially coated with 0.1% Poly(vinylpyrrolidone) (M ave 1,300,000Da) to reduce electroosmotic flow and avoid RNA adsorption. When the capillary was filled with 0.4% poly(ethylene) oxide (M ave 4,000,000) and a nucleic acid-specific fluorescent dye, SYTO 9, the baseline separation of the 18S and 28S ribosomal RNAs (rRNAs) in total RNA was accomplished within 15min. The lowest detectable concentration for the 18S and 28S rRNAs was estimated to be 50pg/μL. Some peaks longer than the 28S rRNA that migrated slowly were observed as long as the initial total RNA concentration was optimized. The temperature-induced degradation of the large RNA fragments (longer than the 28S rRNA) was faster than that of 18S rRNA and 28S rRNA. These large RNA fragments may serve as a promising marker for testing RNA integrity compared to the traditional method.
01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Juan A. Asenjo, Barbara A. Andrews
Aqueous two-phase systems (ATPS) that are formed by mixing a polymer (usually polyethylene glycol, PEG) and a salt (e.g. phosphate, sulphate or citrate) or two polymers, and water can be effectively used for the separation and purification of proteins. The partitioning between both phases is dependent on the surface properties of the proteins and on the composition of the two phase system as has been recently reviewed by Asenjo and Andrews [1]. This paper analyses and reviews some elements that are important for implementation of these processes which are related to phase separation and continuous processing of ATPS. Phase separation for ATPS formed by PEG and salts has been studied and has been found to depend on which of the phases is continuous. Profiles of dispersion heights can be represented as a fraction of the initial height and are independent of the dimensions of the separator. This is important for the design of large scale aqueous two-phase separations. The kinetics of phase separation has been investigated as a function of the physical properties of the system. The settling rate is a crucial parameter for equipment design and it has been studied as a function of viscosity and density of the phases as well as the interfacial tension between them. Correlations that describe the rate of phase separation have been developed. Working in a continuous bottom-phase region is advantageous to ensure fast separation. A mathematical model to describe the continuous, study state operation of these systems has been investigated. Two simulations to show the effect of phase ratio on purification have been carried out which clearly show the effectivity of using such models. The practical application of ATPS has been demonstrated in many cases including a number of industrial applications with excellent levels of purity and yield. Examples include the purification of α-amylase and the large scale “in situ” purification of IGF-1 carried out by Genentech. The production scale purification of chymosin from recombinant Aspergillus supernatant is the most successful industrial application of this technology. Other applications include the separation and purification of human α-antitrypsin from transgenic sheep milk, the purification of monoclonal antibodies, tPA from CHO supernatant and recombinant VLPs (virus like particles) from yeast cells.

Selective transport of single protein molecules inside gold nanotubes

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Changbei Ma, Rui Han, Shengda Qi, Edward S. Yeung
Diffusion of single protein molecules inside gold nanotubes was investigated. 3-dimensional imaging was employed to locate the individual molecules inside the nanotubes as a function of time. As expected, larger proteins and smaller pore sizes resulted in smaller diffusion coefficients. Diffusion within PEG-coated gold nanotubes was found to be two orders of magnitude faster than in previously reported, similar sized untreated polycarbonate membrane pores, showing that adsorption was serious in the latter case. We further demonstrate chromatographic selectivity during transport by modifying the inner surface of the gold nanotubes with self-assembled monolayers of derivatized alkyl thiols. These results should be useful for designing membrane separations.

Simultaneous analysis of 10 trihalomethanes at nanogram per liter levels in water using solid-phase microextraction and gas chromatography mass-spectrometry

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Sebastien Allard, Jeffrey W.A. Charrois, Cynthia A. Joll, Anna Heitz
Trihalomethanes are predominantly formed during disinfection of water via reactions of the oxidant with natural organic matter. Even though chlorinated and brominated trihalomethanes are the most widespread organic contaminants in drinking water, when iodide is present in raw water iodinated trihalomethanes can also be formed. The formation of iodinated trihalomethanes can lead to taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated or chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. The analysis of 10 trihalomethanes in water samples in a single run is challenging because the iodinated trihalomethanes are found at very low concentrations (ng/L range), while the regulated chlorinated and brominated trihalomethanes are present at much higher concentrations (above μg/L). An automated headspace solid-phase microextraction technique, with a programmed temperature vaporizer inlet coupled with gas chromatography-mass spectrometry, was developed for routine analysis of 10 trihalomethanes i.e. bromo-, chloro- and iodo-trihalomethanes in water samples. The carboxen/polydimethylsiloxane/divinylbenzene fiber was found to be the most suitable. The optimization, linearity range, accuracy and precision of the method are discussed. The limits of detection range from 1ng/L to 20ng/L for iodoform and chloroform, respectively. Matrix effects in treated groundwater, surfacewater, seawater, and secondary wastewater were investigated and it was shown that the method is suitable for the analysis of trace levels of iodinated trihalomethanes in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive. A survey conducted throughout various process stages in an advanced water recycling plant showed the presence of iodinated trihalomethanes at ng/L levels.

Aniline–silica nanocomposite as a novel solid phase microextraction fiber coating

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Habib Bagheri, Ali Roostaie
A new unbreakable solid phase microextraction (SPME) fiber coating based on aniline–silica nanocomposite was electrodeposited on a stainless steel wire. The electropolymerization process was carried out at a constant deposition potential, applied to the corresponding aqueous electrolyte containing aniline and silica nanoparticles. The scanning electron microscopy (SEM) images showed the non-smooth and the porous surface structure of the prepared nanocomposite. The applicability of the new fiber coating was examined by headspace-solid phase microextraction (HS-SPME) of some environmentally important polycyclic aromatic hydrocarbons (PAHs), as model compounds, from aqueous samples. Subsequently, the extracted analytes were transferred into a gas chromatography (GC) by thermal desorption. Parameters affecting the synthesizing and extraction processes including the voltage of power supply, the weight ratio of components, the time of electrodeposition, extraction time and temperature, the ionic strength, and desorption temperature and time were optimized. Eventually, the developed method was validated by gas chromatography–mass spectrometry (GC–MS). At the optimum conditions, the relative standard deviation (%RSD) values for a double distilled water spiked with the selected PAHs at 40ngL−1 were 6–13% (n =3) while the limit of detection (LOD) results were between 1 and 3ngL−1. The calibration graphs were linear in the concentration range from 20 to 4000ngL−1 (R 2 >0.995). Finally the developed method was applied to the analysis of Kalan dam, rain and tap water samples and the relative recovery values were found to be in the range of 76–109%, under optimized conditions. In addition, the synthesis of the nanocomposite coating was carried out conveniently while it is rather inexpensive, easy, simple, rapid and highly durable and can be used frequently.

Enhanced pressurized liquid extraction technique capable of analyzing polychlorodibenzo-p-dioxins, polychlorodibenzofurans, and polychlorobiphenyls in fish tissue

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Bikram Subedi, Sascha Usenko
A high-throughput enhanced pressurized liquid extraction technique was developed by incorporating pressurized liquid extraction and multiple cleanup techniques. USEPA methods of polychlorodibenzo-p-dioxins, polychlorodibenzofurans (PCDD/Fs) and dioxin-like polychlorobiphenyls (dl-PCBs) analysis in fish tissue include independent silica gel, florisil, alumina, and carbopack/celite column cleanup techniques following extraction. Under the improved method, fish composites (∼10g) were extracted and cleaned simultaneously using alumina (∼10g), florisil (∼10g), silica gel (∼5g), celite (∼5g), and carbopack (∼0.5g). Clean extracts were concentrated and then analyzed by high resolution gas chromatography coupled with electron capture negative ionization mass spectrometry. Carbopack/celite within the extraction cell provided the analytical separation of dl-PCBs from PCDD/Fs, reducing potential molecular interferences. The average recoveries (n =3) of dl-PCBs in dichloromethane:hexane (1:1, v/v) extracts were 93±2.4% and PCDD/Fs in toluene extracts were 85±3.0%. The developed method was applied to measure the PCDD/Fs and dl-PCBs in catfish from San Jacinto River Waste Pits, a Superfund site in Houston, TX. The dl-PCBs were measured at 5.0–17,000pgg−1 ww. Sample preparation time and solvents were reduced as much as 95% and 65%, respectively, as compared to USEPA method 1613.

Biocompatible phosphatidylcholine bilayer coated on magnetic nanoparticles and their application in the extraction of several polycyclic aromatic hydrocarbons from environmental water and milk samples

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Shengxiao Zhang, Hongyun Niu, Yuanyuan Zhang, Junshen Liu, Yali Shi, Xiaole Zhang, Yaqi Cai
In this work, phosphatidylcholine (PC) was coated on magnetic nanoparticles to form lipid bilayer as solid-phase extraction (SPE) sorbents for the enrichment of polycyclic aromatic hydrocarbons (PAHs) from environmental water and milk samples. The lipid bilayer was coated on Fe3O4 nanoparticles using a modified dry lipid film hydration method. The resulted Fe3O4/PC could be readily isolated from solution with a magnet, and exhibited excellent adsorption performance to organic pollutants. Only 0.1g of sorbents was enough to extract PAHs from 500mL aqueous solution, and 6mL of acetonitrile was required to desorb them. The method was fast and relied on 10min extraction time and 5min magnetic separation. The proposed method was successfully applied to determine PAHs in some environmental water and milk samples. The detection limit was in the range of 0.2–0.6ngL−1. The recoveries of the spiked water samples ranged from 89% to 115% with relative standard deviations (RSD) varying from 1% to 8%. For spiked milk samples, RSD was satisfactory (1–9%), but the recoveries were relatively low (42–62%). We show the potentials of Fe3O4/PC sorbents in environmental water and biological sample analyses.

Bifunctional ultrasound assisted extraction and determination of Elettaria cardamomum Maton essential oil

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Hassan Sereshti, Ahmad Rohanifar, Sadjad Bakhtiari, Soheila Samadi
A new hyphenated extraction method composed of ultrasound assisted extraction (UAE)-optimized ultrasound assisted emulsification microextraction (USAEME) was developed for the extraction and preconcentration of the essential oil of Elettaria cardamomum Maton. The essential oil was analyzed by gas chromatography–mass spectrometry (GC–MS) and optimization was performed using gas chromatography-flame ionization detection (GC-FID). Ultrasound played two different roles in the extraction of the essential oil. First, as a source of sufficient energy to break the oil-containing glands in order to release the oil, and second as an emulsifier to disperse the organic phase within water. The effective parameters (factors) of USAEME including volume of extraction solvent (C2H4Cl2), extraction temperature and ultrasonic time were optimized by using a central composite design (CCD). The optimal conditions were 120μL for extraction solvent volume, 32.5°C for temperature and 10.5min for ultrasonic time. The linear dynamic ranges (LDRs) were 0.01–50mgL−1 with the determination coefficients in the range of 0.9990–0.9999. The limits of detection (LODs) and the relative standard deviations (RSDs) were 0.001–0.007mgL−1 and 3.6–6.3%, respectively. The enrichment factors were 93–98. The main components of the extracted essential oil were α-terpenyl acetate (46.0%), 1,8-cineole (27.7%), linalool (5.3%), α-terpineol (4.0%), linalyl acetate (3.5%).

Rapid whole protein quantitation of staphylococcal enterotoxins A and B by liquid chromatography/mass spectrometry

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Isabel Sospedra, Carla Soler, Jordi Mañes, José Miguel Soriano
Staphylococcus aureus is an important pathogen and has been indicated as the fifth causative agent of food-borne human illness throughout the world. Staphylococcal enterotoxins (SEs) are toxic compounds excreted mainly by strains of S. aureus. Among these toxins, enterotoxins A (SEA) and B (SEB) are both of the most prevalent compounds in staphylococcal food poisoning. In this work, reverse phase liquid chromatography coupled to ESI mass spectrometry (LC–ESI/MS) has been applied for its rapid identification and quantification. Limit of detection (LOD) values were 0.5 and 0.2ng for SEA and SEB, respectively and limit of quantification (LOQ) value was 1ng for both enterotoxins. SEA and SEB have been analyzed as intact proteins in milk and fruit juices. Analytical methods are essential for routine monitoring purposes and safeguard public health and the proposed technique can detect and quantify successfully SEA and SEB in food samples.

A novel hydroquinidine imprinted microsphere using a chirality-matching N-Acryloyl-l-phenylalanine monomer for recognition of cinchona alkaloids

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Qi Zhou, Jing He, Youwen Tang, Zhiguang Xu, He Li, Chengcheng Kang, Jiabing Jiang
Using a combination of molecular imprinting technology and traditional chiral stationary phases, the synergistic effect between chiral monomer and chiral cavity of molecularly imprinted polymers in stereoselective recognition was investigated. We designed and synthesized an amino acid derivative to be used as a novel chiral functional monomer. Monodisperse molecularly imprinted core–shell microspheres using surface imprinting method on silica gel were prepared with hydroquinidine as the pseudo-template molecule for the resolution of cinchona alkaloids. The results showed a significant synergistic effect in stereoselective recognition, confirming our initial hypothesis. Furthermore, our computational simulation and experiments intensively support the hypothetical chiral recognition mechanism for the imprinted microspheres.

A priori selection of the mobile and stationary phase in centrifugal partition chromatography and counter-current chromatography

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Elisabeth Hopmann, Andreas Frey, Mirjana Minceva
The selection of the mobile and the stationary phase in support-free liquid–liquid chromatography (centrifugal partition chromatography and counter-current chromatography) is equivalent to a selection of a biphasic liquid system and its global composition. There is an immense number of choices of biphasic liquid systems. On one hand what makes this technique extremely versatile, on the other hand turns the selection of the appropriate system for a particular separation problem into a challenging and demanding task. In this work a systematic procedure for the selection of biphasic liquid systems for preparative scale separations is presented. The procedure is adaptable to the production scale requirements including production cost and safety. The experimental effort of different stages of the selection procedure is minimized by using a fully predictive method, the conductor-like screening model for real solvents (COSMO-RS). The COSMO-RS is used to assess properties relevant for the selection of a biphasic liquid system, such as the solute solubility and the partition coefficient.

Band broadening in fast gradient high-performance liquid chromatography: Application to the second generation of 4.6mm I.D. silica monolithic columns

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Fabrice Gritti, Georges Guiochon
The sources of band broadening in fast gradient elution chromatography include the contributions of the tubings placed upstream the column, the isocratic migration of the sample that takes place in the column until the moment when the front of the gradient catches up with it, dispersion and mass transfer resistance during band migration under gradient elution to the column outlet, and dispersion in the tubings downstream the column to the detector. The measurements of all these contributions is meticulously described, analyzed, and applied to assess the kinetic performance of monolithic columns of the second generation (KGaA Merck) in gradient elution, at the highest possible speed at which they can be operated (t 0=25s at P =200bar). These results are compared to those provided by several 4.6mm × 100mm columns packed with sub-3μm core–shell particles (Kinetex, Phenomenex and Halo, Advanced Material Technologies) and by a 2.1mm × 100mm column packed with fully porous 1.7μm BEH particles (Waters). A RPLC checkout sample (Agilent) containing nine alkanophenones (molecular weights between 120 and 204g/mol) was used for this purpose. The mobile phase was a mixture of acetonitrile and water and the instrument, an optimized version of the 1290 Infinity HPLC system (Agilent). The results show that the overall peak capacity provided by this second generation of monolithic columns is nearly 30% smaller than that provided by commercial columns packed with sub-3 μm core–shell particles and 20% smaller than that provided by a narrow-bore column packed with sub-2μm fully porous particles. After isolating the sole band broadening contribution due to the gradient migration of the analytes along the columns, the BEH column proved to provide the highest resolution power (apparent average plate height, of 2μm), followed by the 2.6μm Kinetex particles (3.0μm), the Halo particles (3.2μm), and the second generation of 4.6mm I.D. monolithic columns (6.5μm). This work demonstrates that analysts have an urgent need for very high pressure liquid chromatographs having smaller dwell and extra-column volumes that those of the currently available instruments. The gradient elution peak capacity provided by the modern, narrow-diameter columns, which are short and highly efficient (plate heights of 3–4μm), is barely half what the column alone could produce if it were fitted to a perfect instrument. The other half of the peak capacity is just wasted by the instrument.

Computer assisted optimization of liquid chromatographic separations of small molecules using mixed-mode stationary phases

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Edgar Y. Ordoñez, José Benito Quintana, Rosario Rodil, Rafael Cela
Mixed-mode stationary phases are gaining adepts in liquid chromatography (LC) as more and more applications are published and new commercial columns appear in the market ought to their ability to retain and separate analytes with multiple functionalities. The increased number of adjustable variables gives these columns an enhanced value for the chromatographer, but, on the other hand, it complicates the process of developing satisfactory separations when complex samples must be analyzed. Thus, the availability of computer assisted methods development (CAMD) tools is highly desirable in this field. Therefore, the first specific tool for the CAMD of LC separations in mixed-mode columns is presented. The tool consists in two processes. The first one develops a retention model for peaks in a predefined experimental domain of pH and buffer concentration. In this domain, the retention as a function of the proportion of organic modifier is modeled using a two-stage re-calibration process departing from isocratic retention data and then, from gradient elutions. With this two-stage approach, reliability is gained. In the second process, the model is finally interpolated and used for the unattended optimization of the different possible elution modes available in these columns. This optimization process is driven by an evolutionary algorithm. The development and application of this new chemometrics tool is demonstrated by the optimization of a mixture of neutral and ionizable compounds. Hence, several different types of gradients were generated, showing a good agreement between simulated and experimental data, with retention time errors lower than 5% in most cases. On the other hand, classical CAMD tools, such as design of experiments, were unable to efficiently deal with mixed-mode optimizations, rendering errors above 30% for several compounds.

Comparison of various ternary simulated moving bed separation schemes by multi-objective optimization

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Gaurav Agrawal, Yoshiaki Kawajiri
Over the past decade, many modifications have been proposed in simulated moving bed (SMB) chromatography in order to effectively separate a binary mixture. However, the separation of multi-component mixtures using SMB is still one of the major challenges. In addition, the performance of SMB system highly depends on its operating conditions. Our study address this issue by formulating a multi-objective optimization problem that maximizes the productivity and purity of intermediate eluting component at the same time. A number of optimized isocractic ternary SMB operating schemes are compared both in terms of productivity and amount of desorbent to feed ratio. Furthermore, we propose a generalized full cycle (GFC) formulation based on superstructure formulation encompassing numerous operating schemes proposed in the literature. We also demonstrate that this approach has a potential to find the best ternary separation strategy among various alternatives.

Development of analysis of volatile polyfluorinated alkyl substances in indoor air using thermal desorption-gas chromatography–mass spectrometry

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Yaoxing Wu, Victor W.-C. Chang
The study attempts to utilize thermal desorption (TD) coupled with gas chromatography–mass spectrometry (GC–MS) for determination of indoor airborne volatile polyfluorinated alkyl substances (PFASs), including four fluorinated alcohols (FTOHs), two fluorooctane sulfonamides (FOSAs), and two fluorooctane sulfonamidoethanols (FOSEs). Standard stainless steel tubes of Tenax/Carbograph 1 TD were employed for low-volume sampling and exhibited minimal breakthrough of target analytes in sample collection. The method recoveries were in the range of 88–119% for FTOHs, 86–138% for FOSAs, exhibiting significant improvement compared with other existing air sampling methods. However, the widely reported high method recoveries of FOSEs were also observed (139–210%), which was probably due to the structural differences between FOSEs and internal standards. Method detection limit, repeatability, linearity, and accuracy were reported as well. The approach has been successfully applied to routine quantification of targeted PFASs in indoor environment of Singapore. The significantly shorter sampling time enabled the observation of variations of concentrations of targeted PFASs within different periods of a day, with higher concentration levels at night while ventilation systems were shut off. This indicated the existence of indoor sources and the importance of building ventilation and air conditioning system.

Chemometric analysis of gas chromatography with flame ionisation detection chromatograms: A novel method for classification of petroleum products

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
N.J. Nielsen, D. Ballabio, G. Tomasi, R. Todeschini, J.H. Christensen
Most oil characterisation procedures are time consuming, labour intensive and utilise only part of the acquired chemical information. Oil spill fingerprinting with multivariate data processing represents a fast and objective evaluation procedure, where the entire chromatographic profile is used. Methods for oil classification should be robust towards changes imposed on the spill fingerprint by short-term weathering, i.e. dissolution and evaporation processes in the hours following a spill. We propose a methodology for the classification of petroleum products. The method consists of: chemical analysis; data clean-up by baseline removal, retention time alignment and normalisation; recognition of oil type by classification followed by initial source characterisation. A classification model based on principal components and quadratic discrimination robust towards the effect of short-term weathering was established. The method was tested successfully on real spill and source samples.

A novel headspace gas chromatographic method for in situ monitoring of monomer conversion during polymerization in an emulsion environment

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Xin-Sheng Chai, Jin-Feng Zhong, Hui-Chao Hu
This paper describes a novel multiple-headspace extraction/gas chromatographic (MHE-GC) technique for monitoring monomer conversion during a polymerization reaction in a water-based emulsion environment. The polymerization reaction of methyl methacrylate (MMA) in an aqueous emulsion is used as an example. The reaction was performed in a closed headspace sample vial (as a mini-reactor), with pentane as a tracer. In situ monitoring of the vapor concentration of the tracer, employing a multiple headspace extraction (sampling) scheme, coupled to a GC, makes it possible to quantitatively follow the conversion of MMA during the early stages of polymerization. Data on the integrated amount of the tracer vapor released from the monomer droplet phase during the polymerization is described by a mathematic equation from which the monomer conversion can be calculated. The present method is simple, automated and economical, and provides an efficient tool in the investigation of the reaction kinetics and effects of the reaction conditions on the early stage of polymerization.

Use of the isopycnic plots in designing operations of supercritical fluid chromatography: IV. Pressure and density drops along columns

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Abhijit Tarafder, Krzysztof Kaczmarski, Megan Ranger, Donald P. Poe, Georges Guiochon
The pressure- and the density-drops along a chromatographic column eluted with supercritical fluid carbon dioxide were mapped as a function of the outlet column pressure and the temperature on the P–T diagram of neat CO2. At low densities, the viscosity of CO2 is low, which is expected to result into a low pressure drop along the column. However, at these low densities, the volumetric flow rates of the mobile phase at constant mass flow rates are high, which might result into a high pressure drop along the column. These conflicting effects of an adjustment in the mobile phase density on the pressure drop of the mobile phase along the column makes it nearly impossible to develop a simple intuitive understanding of the relationships between the net pressure drops and the operating temperatures and pressures. The development of a similar understanding of their relationships with the density drop along the column is even more complex, because this density drop depends also on the compressibility of the mobile phase, itself a function of the operating pressures and temperatures. Numerical calculations of the pressure and density drops along columns packed with particles of different sizes, under different operating conditions (temperature, outlet pressure, and flow rate), provide important insights regarding the extent of the pressure and density drops under these operating conditions.

Improved capillary electrophoresis frontal analysis by dynamically coating the capillary with polyelectrolyte multilayers

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Chao Liu, Jingwu Kang
An improved CE-FA method using a polyelectrolyte multilayer (PEML) coated capillary is described. The coating was simply created by alternatively flushing the capillary with positively charged polyelectrolyte polybrene (HDB) and negatively charged polyelectrolyte dextran sulfate (DS). Human serum albumin (HSA) and 6 drugs were selected as an experimental model to evaluate such an improvement. The PEML coating was demonstrated to effectively reduce the protein adsorption on the capillary wall. Compared with the uncoated capillary, the repeatability (RSD%) of the EOF mobility and the plateau height of free drug were improved significantly from 3.7% to 0.51% and from 0.61% to 0.34%, respectively. No interference of the coating on the measurement of protein–drug binding parameters was observed.

High resolution separation by pressure-driven liquid chromatography in meander extended nanochannels

01 May 2012, 09:31:29
Publication year: 2012
Source:Journal of Chromatography A, Volume 1238
Ryo Ishibashi, Kazuma Mawatari, Takehiko Kitamori
The rapidly developing interest in nanofluidics, which is used to examine liquids on an order that ranges from an attoliter to a femtoliter, correlates with the recent interest in decreased sample amounts, such as in the field of single-cell analysis. In this paper, we have succeeded in the normal phase separation of a 101 fL sample with a high number of theoretical plates (103 plates), and a fast separation (4s), using a pressure-driven flow in extended nanochannels. A meander separation channel 1μm wide was introduced and showed no band broadening at the turns, unlike microchannels (101–102 μm wide), which is an important aspect in order to lengthen the channel in a space-limited micro/nanofluidic chip. Our device enables the fast separation of an ultra-small volume of sample with a high number of theoretical plates, and will serve as a general platform for the separation of aL to fL volumes of samples. 

JEOL Resonance Introduces Worlds' Fastest and Smallest Solid State NMR Probe


JEOL Resonance, Inc., headquartered in Akishima, Tokyo, announced a new 0.75 mm solid state NMR probe at the 53rd Experimental Nuclear Magnetic Resonance Conference in Miami, Florida. The probe is capable of high resolution sample analysis by spinning the sample at 110 kHz, the world's fastest spinning speed for NMR.
The new probe is expected to be effective in applications that are difficult for conventional NMR systems, including micro analysis of drugs, natural products, and thin films.
"With this new probe, JEOL sets a new benchmark for high resolution and high sensitivity analysis of micro volumes with Solid State NMR," Robert DiPasquale, Division Manager, Analytical Instruments at JEOL USA, reports. 

High Precision 1H Analysis
The unprecedented spinning speed enables high resolution 1H analysis that is not available at lower speeds. This capability allows the researcher to identify different molecular ratios, total structures in organic materials and aids in the structural analysis of proteins. Additionally it allows for high precision analysis of samples containing paramagnetic ions, such as copper binding proteins that play an important role in living organisms. 

High Sensitivity Analysis of Micro Samples
The new Magic Angle Spinning capability provides high sensitivity analysis of micro samples (0.29 μl), 1/100th of the normal sample volume, which allows for structural analysis of limited volume samples, such as natural products and thin films, and analysis of defects and degradation in localized areas of samples.

Structural Analysis
The new 0.75 Solid State NMR probe is ideal for structural analysis, including changes in properties of electrode materials in lithium ion cells after repeated charge/discharge cycles, and the structural degradation analysis of thin film materials such as organic EL and organic transistors, allowing researchers to improve the performance and durability of these products.

Measured Results
Results of solid NMR experiments analyzing the same sample using probes of different spinning speeds show that the signal peak intensities were significantly higher with the new 110 kHz probe when higher spinning speeds were used. The data acquired with the new probe were also higher in resolution, separating peaks more clearly. The new probe will help acquire detailed information on the types of atoms and the molecular structure of many substances.

JEOL Resonance strives to provide superior probes for NMR. The company introduced its first new ultra high spinning speed probe in July 2011, capable of spinning a 1 mm sample tube at an 80 kHz spinning speed, the fastest at that time.

About NMR and MAS
Nuclear Magnetic Resonance (NMR) spectroscopy applies magnetic and rf (radio frequency) fields to a sample in a magnet. The NMR spectrometer observes the nuclear magnetic resonance of the atomic nuclei in the sample as it spins at the Magic Angle (MA), and is capable of analyzing the molecular structure of the sample at the atomic level. Effective in analyzing organic compounds and high molecular weight polymeric materials, NMR has a wide range of applications in pharmaceutical, biology, food, and chemistry. It is increasingly used in new, growing areas such as organic EL and battery films.
Magic Angle Spinning (MAS) spins a sample in an NMR magnet at an angle of 54.7° relative to the magnetic field direction.  This averages out many broadening NMR interactions to greatly improve the resolution and sensitivity of the resulting NMR spectrum.

JEOL Resonance, Inc.
JEOL Resonance, Inc. was formed from the NMR Division of JEOL Ltd., and was partially financed by the Innovation Network Corporation of Japan, http://www.incj.co.jp/english/ and Japan Superconductor Technology, Inc., http://www.jastec-inc.com/e_about/. The company's mission is to develop new technologies, high end products, and new applications. For more information please visit http://j-resonance.com.