World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Monday, 7 May 2012

Just Published: Chemometrics and Intelligent Laboratory Systems


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Chemometrics and Intelligent Laboratory Systems
http://rss.sciencedirect.com/publication/science/5232
Selected papers from the latest issue:

Study of indole derivative inhibitors of Cytosolic phospholipase A2α based on Quantitative Structure Activity Relationship

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Xiaoquan Lu, Dongqin Ji, Jing Chen, Xibin Zhou, Haicai Shi
Cytosolic phospholipase A2α, one of the three subtypes of Cytosolic phospholipase A2 (α, β and γ), is deemed to play an important role in the arachidonate pathway. Due to the rate-limiting provider for proinflammatory mediators, it is a particularly attractive target for drug development. Studies have revealed that indol derivate compounds can inhibit the activities of Cytosolic phospholipase A2α. However, few papers on the relationship between the molecular structure and the activity of inhibitor were reported. In this study, the Quantitative Structure Activity Relationship (QSAR) of indole derivates has been performed based on the dataset of 49 compounds. By using stepwise multiple linear regression, 5 descriptors were selected from 1777 molecular descriptors, including GGI5 (Topological charge index G5), TIE(dssC) (sum of E-State of atom type dssC: ¦2S(dssC)), RDF115a (the atomic Sanderson ALOGP), RDF100c (the atomic charge), and RDF065p (the atomic polarizability). Subsequently, Partial Least Squares (PLS), Artificial Neural Networks (ANN) and Support Vector Machine (SVM) were adopted to build the QSAR model, respectively. The independent test indicated that the SVM can give the best statistical results. And indole derivative inhibitors activity might be related to global charge transfers, carbon atoms type linked benzyl sulfonamide and molecule geometrical the distance distribution.

Filling and D-optimal designs for the correlated generalized exponential models

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
J.M. Rodríguez-Díaz, M.T. Santos-Martín, H. Waldl, M. Stehlík
The aim of this paper is to provide guidelines for the statistically efficient estimation of parameters of a modified Arrhenius model for chemical kinetics. A modified Arrhenius model is used for instance by modeling a flux of methane in troposphere or by chemical kinetics for reactions at membranes. D-optimal and filling designs for the Generalized Exponential Model with correlated observations are studied, considering the exponential covariance with or without nugget effect. Both equidistant and exact designs for small samples are examined, studying the behavior of different types of filling designs when a greater number of observations is preferred. Probably the main lesson we can learn is that the D-optimal design is analytically peculiar and these designs can be practically obtained only by numerical computation; however, specially two point locally D-optimal designs are very interesting, since they may help us to find a reasonable range for filling designs. The latter ones are probably only applicable when seeking for a higher number of design points. It is an interesting issue that very often the best designs do not use the whole design interval, but only a part of it; this should be taken into account by practitioners when they design their experiments. The second important observation is the large bias of the ML estimator of the correlation parameter. From the theoretical point of view this is not surprising since variance and correlation parameters are not simultaneously identifiable. We develop a bias reduction method and illustrate its effectiveness. We also provide practical implications for chemometrics.

Kernel k-nearest neighbor algorithm as a flexible SAR modeling tool

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Dong-Sheng Cao, Jian-Hua Huang, Jun Yan, Liang-Xiao Zhang, Qian-Nan Hu, Qing-Song Xu, Yi-Zeng Liang
A kernel version of k-nearest neighbor algorithm (k-NN) has been developed to model the complex relationship between molecular descriptors and bioactivities of compounds. Kernel k-NN is to perform the original k-NN algorithm by mapping the training samples in the input space into a high-dimensional feature space. It can be easily constructed by calculating the distance between samples in the feature space, directly deriving from the simple calculation of the kernel used. The developed kernel k-NN is very flexible to deal with complex nonlinear relationship, more importantly; it can also conveniently cope with some non-vectorial data only by the definition of different kernels. The results obtained from several real SAR datasets indicated that the performance of kernel k-NN is comparable to support vector machine methods. It can be regarded as an alternative modeling technique for several chemical problems including the study of structure–activity relationship (SAR). The source codes implementing kernel k-NN in R language are freely available at http://code.google.com/p/kernelmethods/.

Is sensing spatially distributed chemical information using sensory substitution with hyperspectral imaging possible?

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Bjørn K. Alsberg
Chemical images which are often computed from hyperspectral images contain the spatial distribution of chemical information of a scene. For many applications visualizing such images on computer screens is sufficient, however there are cases where there is a need to combine the chemical images more naturally with human vision. This is especially true for interactive work where chemical images are being rapidly updated to the user. Effective integration of spatial information in general from external sources with vision is a challenge. One approach is to overlay the view of the real physical world with computer-generated graphics as in augmented reality. However such cluttering of the visual field with computer-generated graphics may confuse the user and reduce functionality. Another is projecting the chemical images back onto the scene under study in order to render the chemical information in situ to the user. This approach, however has challenges in connection with very small and very large scenes under investigation. An alternative approach is here investigated based on the possibility of enhancing the human vision system using a sensory substitution device. Such devices enables a person to sense spatial information conveyed through sensory channels other than the eye, such as hearing and sense of touch. Results presented support the claim that spatial chemical information from a hyperspectral camera can be conveyed to the brain through a sensory channel different from the eyes. As this is tested on a sighted subject it effectively provides an extension of the human vision system to incorporate chemical information which otherwise is invisible to the naked eye.

Handheld NIRS analysis for routine meat quality control: Database transfer from at-line instruments

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
E. Zamora-Rojas, D. Pérez-Marín, E. De Pedro-Sanz, J.E. Guerrero-Ginel, A. Garrido-Varo
Innovative advances in Near Infrared Spectroscopy (NIRS) instrumentation have enabled the development of new miniaturized spectrometers that combine NIRS technology with micro-electro-mechanical platforms, thus opening up new horizons for industrial NIRS applications. Many agro-food industries, laboratories and research centres already have large databases/libraries, built up over many years using NIR spectrometers; it is clearly important to preserve these data sets in order to avoid having to research and develop NIRS applications from scratch every time a new instrument appears on the market. Three standardization algorithms—Direct Standardization (DS), Piecewise Direct Standardization (PDS) and Spectral Difference by Wavelengths (SDW)—and varying numbers of standardization samples were evaluated for transferring meat quality databases from a high-performance at-line NIRS monochromator to a handheld based on micro-electro-mechanical systems (MEMS) NIRS spectrometer. The SDW algorithm and the use of 8 standardization samples yielded the best Standard Error of Prediction (SEP) values for the three chemical parameters transferred (0.72% for fat, 0.73% for moisture and 0.66% for protein). The successful transfer of the database to the MEMS-NIRS device enables a new approach for fast, low-cost, on-line/in-situ analysis of meat products.

Extracting homologous series from mass spectrometry data by projection on predefined vectors

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Johan E. Carlson, James R. Gasson, Tanja Barth, Ingvar Eide
Multivariate statistical methods, such as Principal Component Analysis (PCA), have been used extensively over the past decades as tools for extracting significant information from complex data sets. As such they are very powerful and in combination with an understanding of underlying chemical principles, they have enabled researchers to develop useful models. A drawback with the methods is that they do not have the ability to incorporate any physical / chemical model of the system being studied during the statistical analysis. In this paper we present a method that can be used as a complement to traditional chemometric tools in finding patterns in mass spectrometry data. The method uses a pre-defined set of equally spaced sequences that are assumed to be present in the data. Allowing for some uncertainty in the peak locations due to the uncertainties for the measurement instrumentation, the measured spectra are then projected onto this set. It is shown that the resulting scores can be used to identify homologous series in measured mass spectra that differ significantly between different measured samples. As opposed to PCA, the loading vectors, in this case the pre-defined homologous series, are readily interpretable.

Application of latent projective graph in variable selection for near infrared spectral analysis

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Xueguang Shao, Guorong Du, Ming Jing, Wensheng Cai
Latent projective graph (LPG) is a technique developed in chemical factor analysis (CFA) for investigating the nature of hyphenated data. Selective variables can be found because collinear variables present a straight line in an LPG. Variable selection in near infrared (NIR) spectral analysis has been a notoriously difficult task for improving the quality of the models, the aim of which is to find informative variables specific to the target component. In this work, based on the assumption that collinear wavelengths in the calibration spectra may have the same contribution to the modeling, LPG was adopted for variable selection in NIR spectral analysis. The variables located at the inflections of an LPG are found to be informative for the quantitative models. With three NIR datasets of pharmaceutical tablets, blood and plant samples, it was proved that a very parsimonious model can be built by using only several selected variables. Compared with the previous work, the method provides a simple way for variable selection.

A QSAR study on the biodegradation activity of PAHs in aged contaminated sediments

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Xiang Xu, Xian-Guo Li, Shu-Wen Sun
The relationship between the chemical structure and biodegradation activity (−logt1/2) of 17 polycyclic aromatic hydrocarbons (PAHs) was studied using density functional theory (DFT) and stepwise multiple linear regression analysis (SMLR) methods. The equilibrium geometries and vibration frequency have been investigated at B3LYP/6-31+G(d,p) level. One high correlation coefficient was found between the wagging vibration frequency (Freq) of the whole molecule and −logt1/2, which is resulted by the special structural characteristic with a big conjugated system. By means of regression analysis, the main factors influencing biodegradation activity were screened, and the equations of quantitative structure–activity relationship (QSAR) were established. The evaluation of the developed QSAR showed that the relationships are significant and the model had good predictive ability. The QSAR model showed that the biodegradation activity was closely related to molecular structure: the chemical bond strength of benzene ring played an important role in biodegradation process; In addition, low molecular weight PAHs are more degradable than the high molecular weight compounds.

Post-experimental denoising and background subtraction of surface plasmon resonance images for better quantification

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Jun Chen, Yi Chen, Jiying Xu, Yiming Zhang, Tao Liao
A method was proposed to improve the quality of noise- and/or uneven background-degraded images obtained by surface plasmon resonance imaging experiments. The noise was suppressed by adaptive median filter in combination with wavelet transform, while the uneven background was flattened by subtraction with a three-dimensionally fitted surface. These operations improved the signal-to-noise ratio from 23.83dB to 41.36dB for real images and widened the quantitative linear range of picture gray value vs. concentration for about one order of magnitude, with linear correlation coefficient increased from 0.9558 to 0.9982. The method can be performed repeatedly until a better result is obtained and is thus cost-effective, highly competitive to experimental strategies and other computational methods.

Evaluation of the adsorption and rate constants of a photocatalytic degradation by means of HS-MCR-ALS. Study of process variables using experimental design

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Cristina Fernández, Anna de Juan, M. Pilar Callao, M. Soledad Larrechi
The effect of the catalyst type, the catalyst concentration and the pH on the global rate of the photocatalytic degradation of C.I. Acid Yellow 9 was studied. Adsorption and rate constants related to the physical adsorption on the catalyst surface and the degradation of the dye upon illumination were calculated by applying hybrid hard- and soft-multivariate curve resolution alternating least squares (HS-MCR-ALS), including the Langmuir–Hinshelwood kinetic model as hard restriction, to the UV–visible spectra recorded during the photocatalytic degradation process. The influence of the variables on the degradation rate was assessed using the experimental results obtained from a full factorial 23 experimental design. Physical adsorption was more relevant when TiO2 was employed as a catalyst. The global rate of the photocatalytic degradation of the dye was found to be closely related to the catalyst type, its concentration level and the interaction between both factors. pH was only found to be relevant when TiO2 was used. The photodegradation of C.I. Acid Yellow 9 was optimal when using high concentrations of ZnO as catalyst.

New cluster mapping tools for the graphical assessment of non-dominated solutions in multi-objective optimization

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
R. Cela, M.H. Bollaín
Two new graphical tools for the interpretation of Pareto fronts and the selection of non-dominated solutions produced in multi-objective optimization processes (MOOPs), are presented. The first is a version of the parallel coordinates plots (PCP), modified by combining the PCP with the dendrogram representing the cluster analysis of non-dominated solutions in the decision variable space or in the objective space. A correspondence plot that simplifies interpretation of the above plots has also been developed. The second graphical tool is a cluster map (PFCM), produced by combining the information provided by the dendrograms calculated in the decision and the objective spaces, to provide a two-dimensional plot in which the non-dominated solutions are organized according to both dendrograms; the plot is colored on the basis of any of the objectives or a combination of these objectives when convenient. Two derived graphic tools consisting of a combination of the decision variables and the objectives and the dendrograms produced in the decision and the objective spaces have also been developed. All of these graphical tools are demonstrated with several mathematical functions available in the MOOP-related literature and with a real-world optimization process consisting of the computer-assisted method development of high-performance liquid chromatography.

Online estimation of reject gas flow rates in compact flotation units for produced water treatment: A feasibility study

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Benjamin Kaku Arvoh, Steinar Asdahl, Karsten Rabe, Maths Halstensen
The largest waste water stream from oil and gas production wells is referred to as produced water (PW). One way of treating PW to limits acceptable for discharge into sea is by the use of compact flotation units (CFU). Currently, CFUs' are operated manually due to lack of advanced monitoring solutions. The main areas of interest in the current operation of the flotation unit are to provide online measurements of both liquid and gas flow rates through the reject stream of the flotation unit. A full scale feasibility study on the application of acoustic measurements and partial least squares regression as a tool for online estimation of the reject gas flow rate was investigated. From the experiments conducted to determine the optimal sensor location, it was concluded that there were no significant differences between the four sensor locations investigated. Several reject gas flow rate models were calibrated and validated with fully independent data. The average root mean square error of prediction (RMSEP) was 7.5% within the experimental range (0.07–2.5 Sm3/h). The RMSEP for experiments with varying salt concentration was 0.25% (within the range of 0–5.5%) whilst that for varying temperature was 1.8°C (within the range of 30–60°C). The model for reject liquid flow rates through the CFU had a RMSEP of 16.86l/h (within the range of 225–485l/h). These promising results will form the basis for further development and implementation of the technique in flotation units.

New similarity metrics for Raman spectroscopy

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Shehroz S. Khan, Michael G. Madden
Similarity metrics are at the heart of spectral library search procedures that are used to identify unknown substances. The problem is relatively easy when the query spectrum (that is, a spectrum of the substance to be identified) is directly represented in the library, but in general this is not the case, and the query spectrum may come from a mixture of substances that are either individually represented in the library or as a mixture. In such cases, employing standard search metrics may not yield good results. A well-known general strategy to improve search is to design domain-specific metrics that capture its intrinsic properties. In this paper, we present a new Raman spectroscopy specific spectral similarity metric, Spectral Linear Kernel, which captures the domain subtleties while performing spectral search and performs better in comparison to standard spectral search methods. We also present a new modified Euclidean measure which not only performs better than the standard Euclidean method but other standard methods. We evaluate our results on Raman spectroscopy data for chlorinated solvents.

Recognition of the hardness of licorice seeds using a semi-supervised learning method and near-infrared spectral data

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Liming Yang, Qun Sun
The recognition of the hardness of licorice seeds is a challenging task. The purpose of this investigation is to identify the hardness of licorice seeds employing a semi-supervised learning method and near-infrared spectroscopy. An excellent semi-supervised learning model, the semi-supervised support vector machine (S3VM), is built using the small labeled samples and the large unlabeled samples. Moreover, the proposed model is solved by employing an effective method, the robust DC (difference of convex functions) programming. The resulting algorithm only requires the solving of a few linear programs. Furthermore, this model is used for the direct classification of licorice samples. Comparing with the supervised support vector machine (SVM), experimental results on different spectral regions show that incorporating unlabeled samples in training improves the generalization when insufficient training information is available. Moreover, our method outperforms the existing S3VM method by obtaining better performance in different spectral regions. These results show that it is possible to identify the hardness of licorice seeds using the proposed S3VM and near-infrared spectroscopic data. We hope that the results obtained in this study will help further investigations of the hardness of crop seeds.

WSPLS — A new approach towards mixture modeling and accelerated product development

07 May 2012, 20:50:54
Publication year: 2012
Source:Chemometrics and Intelligent Laboratory Systems, Volume 114
Salvador García-Muñoz, Mark Polizzi
A new method is presented to model mixture data which simultaneously regresses the fractions of the materials used in a series of blends, and the matrix of the physical properties of the materials used in such blends to the properties measured from the resulting blend. The Weighted Scores Projection to Latent Structures (WSPLS) method combines the fractions of the used materials and their physical properties by first transforming the physical properties with a Principal Component Analysis (PCA) model and then estimating a matrix of weighted average scores using the fractions of the materials used and the corresponding scores for each material from the PCA models. This matrix of weighted scores is the regressor in the PLS model against the measured properties of the mixture. The new method is contrasted with other alternatives and shown to provide robust models with strong predictive components across all latent variables. A data set from blends of pharmaceutical powders is used to illustrate the features of the method proposed. 

Analyzing environmental samples for percentage levels of carbon, hydrogen and nitrogen

Analyzing environmental samples for percentage levels of carbon, hydrogen and nitrogen (CHN) is achieved quickly, easily and reliably using the CE 440 Elemental Analyzer from Exeter Analytical Inc.

Traditional methodologies for determining CHN content of soil, plant and insect samples typically use macro-CHN or Kjehldahl Nitrogen analysis. While both these techniques are proven to generate useful data, both have drawbacks. Macro-CHN analyzers are relatively expensive to purchase and run compared to Micro-CHN systems, such as the CE 440, and Kjehldahl requires use of highly corrosive and toxic chemicals. A growing number of crop research institutes are benefiting from the CE 440's routine ability to accurately and precisely determine the CHN content of a wide range of soil, plant and insect materials using samples sizes of typically 2 - 20mg.

As the CE 440 provides complete control over combustion parameters it is able to reproducibly achieve 100% combustion with almost any sediment sample. For sediment samples with low levels of Nitrogen in the 0.1-0.2% range, proprietary Nitrogen analysis software uniquely enables accurate measurement at these levels with a high degree of accuracy.

Beneficially the CE 440 also provides the capacity to process air and water monitoring filters up to 50mm in diameter in one analytical cycle.  By comparison other elemental analyzers, employing vertical furnace designs, require larger filters to be sub sampled several times and then corrective calculations made to enable analysis.

The horizontal furnace design of the CE 440 allows removal of residues between runs preventing cross contamination and enabling in excess of 1000 samples to be run between combustion tube changes. The gas flow characteristics of the CE 440 analyzer are superior to other elemental analyzers due to the effective elimination of troublesome residue build-up. This leads to longer-term calibration stability as well as enhanced accuracy and precision for measured sample data.

Low gas and reagent consumption combined with high reduction tube life allows the CE 440 to deliver some of the lowest operating costs of any CHN elemental analyzer available. Intuitive Windows based operating software reduces human errors through incorporation of extensive automation, comprehensive customer help and diagnostic facilities.  Most parts on the CE 440 are user replaceable further reducing operating costs and downtime.

As a company dedicated to elemental microanalysis, Exeter Analytical's 25+ years of involvement with instruments, consumables and supplies has allowed them to better understand the whole problem facing microanalysts.  As a consequence whether you are a regular or an occasional purchaser - experienced and knowledgeable staff are always available to provide free informed advice.

Friday, 4 May 2012

Just Published: Journal of Chromatography A


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Chromatography A
Selected papers from the latest issue:

Recent developments in the detailed characterization of polymers by multidimensional chromatography

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Anja Baumgaertel, Esra Altuntaş, Ulrich S. Schubert
Synthetic polymers as well as biopolymers reveal complex structures, such as variations in functionality, chain length and architecture. Therefore, combinations of different chromatographic techniques are a prerequisite for a detailed characterization. One possible approach is the combination of high performance liquid chromatography at critical conditions (LCCC) and size-exclusion chromatography, also named as two-dimensional chromatography, which allows the separation of the polymers according to different properties, like molar mass, chemical composition or functionality. In addition, LCCC hyphenated with different mass spectrometry techniques, e.g. MALDI-TOF or ESI-TOF, leads to additional information about molecular details of the polymeric structure. We summarize in this article the recent developments in two-dimensional chromatography of synthetic polymers and biopolymers since 2005.

Comparison of sample preparation approaches for phospholipids profiling in human serum by liquid chromatography–tandem mass spectrometry

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
C. Ferreiro-Vera, F. Priego-Capote, M.D. Luque de Castro
Fractionation of biological fluids for proper analysis by LC–MS of low-abundance metabolites in the presence of high-abundant endogenous metabolites is of interest, particularly when the latter cause undesirable phenomena such as ionization suppression, as is the case with phospholipids (PLs). An exhaustive study and comparison of different protocols for sample preparation based on deproteinization, liquid–liquid extraction (LLE) and solid-phase extraction (SPE) has been carried out with the main aim of implementing metabolomics analysis of PLs within a global metabolite profiling of serum. After selecting LLE and SPE as the best strategies for sample preparation, the fractions from each approach were analyzed by LC–TOF/MS in positive and negative ionization modes, and the highest number of molecular features was found by the latter strategy (2667 versus 1911 in the positive ionization mode). SPE also allows obtaining a clean elution of PLs which made possible tentative identification of these metabolites in both ionization modes by matching to the Human Metabolome Database. Confirmatory analysis to assess PLs identity was supported on MS/MS experiments at different collision energies.

Selective extraction of genotoxic impurities and structurally alerting compounds using polymeric ionic liquid sorbent coatings in solid-phase microextraction: Alkyl halides and aromatics

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Tien D. Ho, Manishkumar D. Joshi, Mark A. Silver, Jared L. Anderson
A series of polymeric ionic liquids (PILs) possessing varied chemical makeup and composition were applied as selective solid-phase microextraction (SPME) sorbent coatings for the analysis of genotoxic impurities (GTIs) and related structurally alerting compounds, namely, alkyl halides and aromatics. In addition to exploiting two previously synthesized PILs as selective coatings, two new PILs, namely, N,N-didecyl-N-methyl-d-glucaminium poly(2-methyl-acrylic acid 2-[1-(3-{2-[2-(3-trifluoromethanesulfonylamino-propoxy)-ethoxy]-ethoxy}-propylamino)-vinylamino]-ethyl ester) (poly([DDMGlu][MTFSI])), and poly(1-vinyl-3-propylphenylimidazolium) chloride (poly([VPPIM][Cl])), were designed, synthesized, and their selectivity examined in the extraction of the selected analytes. The glucaminium-based coating was developed to exploit the hydrogen bond-acidic hydroxyl groups within the carbohydrate moiety of the PIL in addition to dispersive capabilities resulting from the cation and anion. The poly([VPPIM][Cl]) coating was tailored to possess π–π interaction capabilities through the phenyl functionality while also containing the hydrogen bond-basic chloride anion. Calibration studies were performed via headspace extraction to determine the sensitivity and limit of detection (LOD) for all analytes with respect to each PIL-based sorbent coating and compared to the polyacrylate (PA) and polydimethylsiloxane (PDMS) sorbent coatings. PILs containing the chloride anion exhibited high selectivity for aniline-based compounds. The glucaminium-based PIL exhibited good sensitivity for larger aliphatic alkyl halides. The poly(1-4-vinylbenzyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl] imide (poly([VBHDIM][NTf2])) PIL coating demonstrated superior selectivity for larger aliphatic/aromatic analytes. The LODs of both commercial and PIL-based coatings for the two classes of GTIs ranged from low part-per-billion (ppb) to mid part-per-trillion (ppt) levels. Recovery studies were performed at two concentration levels within the linear range in order to validate the accuracy of the technique. Scanning electron micrographs were obtained for three PIL-based coatings following approximately 70 extraction/desorption steps, wherein the fiber coatings were observed to be largely smooth and intact.

Dispersive microextraction based on water-coated Fe3O4 followed by gas chromatography–mass spectrometry for determination of 3-monochloropropane-1,2-diol in edible oils

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Qin Zhao, Fang Wei, Neng Xiao, Qiong-Wei Yu, Bi-Feng Yuan, Yu-Qi Feng
In the present work, we developed a novel dispersive microextraction technique by combining the advantages of liquid-phase microextraction (LPME) and magnetic solid-phase extraction (MSPE). In this method, trace amount of water directly absorbed on bare Fe3O4 to form water-coated Fe3O4 (W-Fe3O4) and rapid extraction can be achieved while W-Fe3O4 dispersed in the sample solution. The analyte adsorbed W-Fe3O4 can be easily collected and isolated from sample solution by application of a magnet. It was worth noting that in the proposed method water was used as extractant and Fe3O4 served as the supporter and retriever of water. The performance of the method was evaluated by extraction of 3-monochloropropane-1,2-diol (3-MCPD) from edible oils. The extracted 3-MCPD was then derived by a silylanization reagent (1-trimethylsilylimidazole) before gas chromatography–mass spectrometry (GC–MS) analysis. Several parameters that affected the extraction and derivatization efficiency were investigated. Our results showed that the limit of detection for 3-MCPD was 1.1ng/g. The recoveries in spiked oil samples were in the range of 70.0–104.9% with the RSDs less than 5.6% (intra-day) and 6.4% (inter-day). Taken together, the simple, rapid and cost-effective method developed in current study, offers a potential application for the extraction and preconcentration of hydrophilic analytes from complex fatty samples.

Removal of potentially genotoxic acetamide and arylsulfonate impurities from crude drugs by molecular imprinting

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
György Székely, Emelie Fritz, Joao Bandarra, William Heggie, Börje Sellergren
The present study describes the synthesis and preliminary testing of molecularly imprinted polymers (MIPs) as scavenger resins for removal of the genotoxic impurities (GTI) acetamide and arylsulfonates from active pharmaceutical ingredients (API). The MIPs were synthesized as monoliths using acetamide or methyl tosylate respectively as templates. The polymers were crushed and subsequently tested in the batch and chromatographic mode for template recognition and potential removal efficiency. Both the acetamide and the tosylate MIPs exhibited a strong memory effect for their templates and selectivity with respect to model APIs. For instance the MIP for acetamide preferentially retained acetamide over other amides, such as formamide, acrylamide, methacrylamide, benzamide and N-tert-butylacrylamide. Moreover, passing model API crude contaminated with the acetamide through the MIPs led to the quantitative removal of acetamide.

Full evaporation dynamic headspace and gas chromatography–mass spectrometry for uniform enrichment of odor compounds in aqueous samples

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Nobuo Ochiai, Kikuo Sasamoto, Andreas Hoffmann, Kazunori Okanoya
A method for analysis of a wide range of odor compounds in aqueous samples at sub-ngmL−1 to μgmL−1 levels was developed by full evaporation dynamic headspace (FEDHS) and gas chromatography–mass spectrometry (GC–MS). Compared to conventional DHS and headspace solid phase microextraction (HS-SPME), FEDHS provides more uniform enrichment over the entire polarity range for odor compounds in aqueous samples. FEDHS at 80°C using 3L of purge gas allows complete vaporization of 100μL of an aqueous sample, and trapping and drying it in an adsorbent packed tube, while providing high recoveries (85–103%) of the 18 model odor compounds (water solubility at 25°C: log0.54–5.65mgL−1, vapor pressure at 25°C: 0.011–3.2mmHg) and leaving most of the low volatile matrix behind. The FEDHS-GC–MS method showed good linearity (r 2 >0.9909) and high sensitivity (limit of detection: 0.21–5.2ngmL−1) for the model compounds even with the scan mode in the conventional MS. The feasibility and benefit of the method was demonstrated with analyses of key odor compounds including hydrophilic and less volatile characteristics in beverages (whiskey and green tea). In a single malt whiskey sample, phenolic compounds including vanillin could be determined in the range of 0.92–5.1μgmL−1 (RSD<7.4%, n =6). For a Japanese green tea sample, 48 compounds including 19 potent odorants were positively identified from only 100μL of sample. Heat-induced artifact formation for potent odorants was also examined and the proposed method does not affect the additional formation of thermally generated compounds. Eighteen compounds including 12 potent odorants (e.g. coumarin, furaneol, indole, maltol, and pyrazine congeners) were determined in the range of 0.21–110ngmL−1 (RSD<10%, n =6).

Effect of ionization modifiers on the simultaneous analysis of all classes of phospholipids by nanoflow liquid chromatography/tandem mass spectrometry in negative ion mode

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Dae Young Bang, Sangsoo Lim, Myeong Hee Moon
The effect of ionization modifiers added to the mobile phase of nanoflow liquid chromatography–tandem mass spectrometry (nLC-ESI–MS3) on the simultaneous analysis of all phospholipid (PL) classes in negative ion mode has been investigated. While MS analysis of most PL classes is carried out in negative ion mode, analysis of neutral polar (polar but electrically neutral) lipids like phosphatidylcholine (PC) and sphingomyelin (SM) is highly efficient in positive ion mode. Therefore, analysis of PL mixture samples often requires two separate runs in both positive and negative ion mode. In order to establish run conditions to carry out a single nLC-ESI–MS–MS for all PLs, the ionization efficiency of 13 different types of PL molecules in nLC-ESI–MS has been evaluated in negative ion mode by varying the modifiers and their concentrations. Experiments demonstrated that a mixture of 0.05% ammonium hydroxide and 1mM ammonium formate added to the mobile phase provided effective ionization for all classes of PLs. The optimized conditions were applied to the analysis of a phospholipid mixture extracted from a human urine sample, yielding the identification of a total of 85 PL species. Analysis of the same sample with dual nLC-ESI–MS2 runs in both positive and negative ion mode confirmed that nLC-ESI-MS3 with the mixed modifier run only in negative ion mode gave comparable results.

On-line fractionated size exclusion chromatography–nuclear magnetic resonance of polymers with 1H and 2H nuclear magnetic resonance detection

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Wolf Hiller, Mathias Hehn, Thorsten Hofe, Kirsten Oleschko, Peter Montag
A new approach for on-line SEC–NMR is introduced. The method combines time slicing, fractionation with adjusted loop collection and automatic stop-flow NMR analysis. It will be called on-line fractionated SEC–NMR. This technique allows the precise determination of molar mass distributions for any polymer which can be detected by NMR. It is a significant improvement of sensitivity and accuracy compared to onflow SEC–NMR and exhibits a much easier experimental setup than off-line SEC–NMR fractionation. The new method was applied to protonated and deuterated block copolymers by using 1H NMR and for the first time also 2H NMR detection. In this case block copolymers can be correctly characterized according to their block length distributions. As the consequence very precise molar mass parameters M n and M w can be determined. The results of the on-line fractionated SEC–NMR are in very good agreement with the multi detector analysis. The new technique also proposes a method for separating the true copolymer and low molar mass fractions in the mixture, whose structures are confirmed by HPLC–FTIR and 2D chromatography.

Separation of unsaturated organic compounds using silver–thiolate chromatographic material

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
José C. Aponte, James T. Dillon, Rafael Tarozo, Yongsong Huang
Separation of organic compounds containing various numbers of double bonds (DB) can be readily achieved by using silver ion impregnated silica gel, often called silver-ion or argentation chromatography. However, the practical application of silver-ion liquid chromatography in analytical and preparative separations has been limited by the concerns about the stability and mobility of silver ions and the widespread use of reversed phase high performance liquid chromatography. Silver covalently anchored onto the thiol moiety of mercaptopropyl modified silica gel has been tested for the separation of polycyclic aromatic hydrocarbons by ring numbers, but has never been shown to separate mixtures of alkenes having different number of double bonds. We report here that silver–thiolate chromatographic material (AgTCM; including, but not limited to, silver(I) mercaptopropyl silica gel) is also highly efficient in liquid chromatographic separation of alkane/alkenes differing by one double bond. AgTCM displays exceptionally high selectivity for unsaturated compounds and high stability under extended heat and light exposure, while silver is virtually immobile during solvent elution. Compared to ionic silver, silver–thiolate interacts with double bonds less strongly, allowing AgTCM to efficiently separate olefins using less polar (and often less viscous and lower cost) solvents. The interaction energy between silver and ethylene is calculated using established computational methods and the results are in full agreement with our experimental results. Importantly, the exceptional stability of AgTCM gives rise to much higher compound recovery than conventional silver-ion silica gel during the chromatographic elution. Our results pave the way for the development of novel covalently bonded, transition metal-containing chromatographic materials.

Efficient liquid chromatographic analysis of mono-, di-, and triglycerols using silver thiolate stationary phase

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
James T. Dillon, José C. Aponte, Rafael Tarozo, Yongsong Huang
We show that the characterization of mono-, di- and triglycerols can be readily accomplished by high performance liquid chromatography (HPLC) with silver(I)-mercaptopropyl modified silica gel, or silver thiolate chromatographic material (AgTCM), which can be used with evaporative light scattering detection (ELSD) or atmospheric pressure chemical ionization mass spectroscopy (APCI-MS). Separation of triglycerols varying by degrees of unsaturation and cis/trans configuration in common oil samples can be achieved using a simple linear gradient of hexane and acetone. In addition to double bonds, AgTCM also displays major selectivity for compounds with different levels of polarity, allowing for efficient separation between mono-, di- and triglycerols. In comparison to conventional reversed phase columns, AgTCM produces simple chromatograms for rapid assessment of degrees of unsaturation and the amount of trans fats in triglycerides, which are central issues to food quality determination. In comparison to previous silver-ion based HPLC separations, AgTCM–HPLC based column offers greatly enhanced stability, inertness, durability, and reproducibility allowing routine coupling of the HPLC with a mass spectrometer for detection.

High-performance liquid chromatography–mass spectrometry and evaporative light-scattering detector to compare phenolic profiles of muscadine grapes

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Qi You, Feng Chen, Julia L. Sharp, Xi Wang, Yuru You, Chuanji Zhang
Evaporative light scattering detector (ELSD) is considered as a universal detector able to detect almost any compound. This study successfully established a HPLC-ELSD method for the simultaneous determination of phenolic acids, flavonoids and anthocyanins in muscadine grape. Twenty-four phenolics, including 5 anthocyanins, were identified by HPLC–UV-MS, ten of them were selected to calibrate the ELSD. Results from the ELSD quantification suggested that gallic acid, proanthocyanidins, and ellagic acid were the main phenolics in muscadines. In addition, antioxidant tests suggested that the extracts of muscadine grapes possessed strong antioxidant activities. All extracts had a high total phenolic content (TPC). High total anthocyanins contents (TAC) were found in Noble muscadine, and high proanthocyanidins content (TPA) in the seed portion.

Excess adsorption of binary aqueous organic mixtures on various reversed-phase packing materials

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
S. Buntz, M. Figus, Z. Liu, Y.V. Kazakevich
Excess adsorption isotherms of acetonitrile and methanol from water were measured on eight commercial columns. Columns used in this study represent latest examples in column development and include three different poroshell columns (Kinetex-C18, Acsentis-C18 and Halo-C18) as well as conventional columns with significantly different adsorbent geometry (Allure-C18, YMC-C18) and various hybrid-silica columns (Gemini-C18, Xterra-C18 and XBridge-C18). Comparison of the excess adsorption isotherms measured on all these columns and expressed in surface specific form demonstrated significant similarity of the adsorption properties of all columns, which allows us to introduce the “standard adsorption isotherm” for reversed-phase C18-type columns. The methodology of the evaluation of the total amount of adsorbent in the column and effective surface area of the C18 modified adsorbent is also discussed. These terms are critical for successful evaluation of surface specific parameters.

Extension of the liquid chromatography/quantitative structure–property relationship method to assess the lipophilicity of neutral, acidic, basic and amphotheric drugs

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Juan M. Pallicer, Carme Calvet, Adriana Port, Martí Rosés, Clara Ràfols, Elisabeth Bosch
A reported chromatographic method to determine the 1-octanol/water partition coefficient (log P o/w) has been used to estimate the lipophilicity of 33 drugs with diverse structures and functionalities, including neutral, acid, basic, and amphoteric compounds. The applicability of the chromatographic method has been extended to the UHPLC technique, and the results obtained were compared to those obtained from conventional HPLC. No significant difference between the results obtained by both techniques is noticed. Thus, the suitability of UHPLC, which involves shorter run times, for lipophilicity assessment is demonstrated. In order to show the consistency of this chromatographic method, the log P o/w values of those drugs which have acid–base properties have been also determined by potentiometry, and the final results have been compared with both values derived from the chromatographic method and the ones from the literature.

Enantioseparation of omeprazole—Effect of different packing particle size on productivity

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Martin Enmark, Jörgen Samuelsson, Patrik Forssén, Torgny Fornstedt
Enantiomeric separation of omeprazole has been extensively studied regarding both product analysis and preparation using several different chiral stationary phases. In this study, the preparative chiral separation of omeprazole is optimized for productivity using three different columns packed with amylose tris (3,5-dimethyl phenyl carbamate) coated macroporous silica (5, 10 and 25μm) with a maximum allowed pressure drop ranging from 50 to 400bar. This pressure range both covers low pressure process systems (50–100bar) and investigates the potential for allowing higher pressure limits in preparative applications in a future. The process optimization clearly show that the larger 25μm packing material show higher productivity at low pressure drops whereas with increasing pressure drops the smaller packing materials have substantially higher productivity. Interestingly, at all pressure drops, the smaller packing material result in lower solvent consumption (L solvent/kg product); the higher the accepted pressure drop, the larger the gain in reduced solvent consumption. The experimental adsorption isotherms were not identical for the different packing material sizes; therefore all calculations were recalculated and reevaluated assuming identical adsorption isotherms (with the 10μm isotherm as reference) which confirmed the trends regarding productivity and solvent consumption.

Development and comparison of three liquid chromatography–atmospheric pressure chemical ionization/mass spectrometry methods for determining vitamin D metabolites in human serum

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Mary Bedner, Karen W. Phinney
Liquid chromatographic methods with atmospheric pressure chemical ionization mass spectrometry were developed for the determination of the vitamin D metabolites 25-hydroxyvitamin D2 (25(OH)D2), 25-hydroxyvitamin D3 (25(OH)D3), and 3-epi-25-hydroxyvitamin-D3 (3-epi-25(OH)D3) in the four Levels of SRM 972, Vitamin D in Human Serum. One method utilized a C18 column, which separates 25(OH)D2 and 25(OH)D3, and one method utilized a CN column that also resolves the diastereomers 25(OH)D3 and 3-epi-25(OH)D3. Both methods utilized stable isotope labeled internal standards for quantitation of 25(OH)D2 and 25(OH)D3. These methods were subsequently used to evaluate SRM 909c Human Serum, and 25(OH)D3 was the only vitamin D metabolite detected in this material. However, SRM 909c samples contained matrix peaks that interfered with the determination of the [2H6]-25(OH)D3 peak area. The chromatographic conditions for the C18 column were modified to remove this interference, but conditions that separated the matrix peaks from [2H6]-25(OH)D3 on the CN column could not be identified. The alternate internal standard [2H3]-25(OH)D3 did not suffer from matrix interferences and was used for quantitation of 25(OH)D3 in SRM 909c. During the evaluation of SRM 909c samples, a third method was developed using a pentafluorophenylpropyl column that also separates the diastereomers 25(OH)D3 and 3-epi-25(OH)D3. The 25(OH)D3 was measured in SRM 909c using all three methods, and the results were compared.

Investigation of porous graphitic carbon for triterpenoids and natural resinous materials analysis by high performance liquid chromatography hyphenated to mass spectrometry

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
B. Rhourri-Frih, P. Chaimbault, D. Dequeral, P. André, M. Lafosse
Natural resinous materials are mainly composed of pentacyclic triterpenes which exhibit a large number of interesting medicinal activities. However, the presence of numerous isomers within the active substances makes their screening by HPLC very challenging. Porous graphitic carbon was investigated as stationary phase to achieve triterpenes isomers separation. The influence of various parameters (temperature, formic acid concentration and mobile phase composition) on the retention was considered. A usual decrease of the retention of triterpenes was observed with the increase of the temperature. Therefore, separation in resinous materials was performed at 25°C. Acetonitrile–isopropanol mixture was chosen as mobile phase in gradient elution and leads to the best compromise between efficiency and high resolution. The lack of chromophore groups in the pentacyclic triterpenes structures required the use of mass spectrometry detection. Moreover, atmospheric pressure photo-ionisation mass spectrometry prevents compounds fragmentation which was helpful for spectra interpretation and compounds identification.

Identification and quantification of potential metabolites of Gd-based contrast agents by electrochemistry/separations/mass spectrometry

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Lena Telgmann, Helene Faber, Sandra Jahn, Daniel Melles, Hannah Simon, Michael Sperling, Uwe Karst
Oxidative and potentially metabolic pathways of the five most frequently used contrast agents for magnetic resonance imaging (MRI) based on gadolinium (Gd) are examined. The oxidation of gadopentetate (Gd-DTPA) was studied with a focus on electrochemical oxidation coupled to analytical separation methods and mass spectrometric detection. Mass voltammograms generated with online electrochemistry/electrospray ionization mass spectrometry (EC/ESI-MS) gave a first overview of oxidation products. Two potential metabolites could be detected, with the major metabolite originating from an N-dealkylation (M1). Four other Gd complexes used as MRI contrast agents showed similar reactions in the EC/ESI-MS set-up. To obtain more information about the properties and the quantity of the generated products, a wide range of separation and detection techniques was applied in further experiments. Gd-DTPA and its N-dealkylation product were successfully separated by capillary electrophoresis (CE) and detected by ESI-MS and inductively coupled plasma (ICP)-MS, respectively. CE experiments indicated that the second oxidation product (M2) detected in the mass voltammogram is unstable and decomposes to M1. Employing EC/CE/ICP-MS, the quantification of the metabolites could be achieved. Under the employed conditions, 8.8% of Gd-DTPA was oxidized. Online experiments with high performance liquid chromatography (HPLC) coupled to ESI-MS confirmed the decomposition of M2. Time-resolved measurements showed a decrease of M2 and a simultaneous increase in M1 within only a few minutes, confirming the conclusion that M2 degrades to M1, while EC/LC/ICP-MS measurements provided quantitative evidence as well. The EC/MS simulation shows that a metabolic transformation should not be disregarded in further research regarding the trigger of nephrogenic systemic fibrosis (NSF), a disease exclusively observed for several hundred dialysis patients after delivery of Gd-based MRI contrast agents with linear structure. Furthermore, the used methods may allow the prediction of options for the oxidative removal of these contrast agents from wastewaters.

Gas chromatography–mass spectrometry with chemometric analysis for determining 12C and 13C labeled contributions in metabolomics and 13C flux analysis

04 May 2012, 11:54:34
Publication year: 2012
Source:Journal of Chromatography A, Volume 1240
Song Yang, Jeremy S. Nadeau, Elizabeth M. Humston-Fulmer, Jamin C. Hoggard, Mary E. Lidstrom, Robert E. Synovec
A novel method for the analysis of nearly co-eluting 12C and 13C isotopically labeled metabolites has been developed and evaluated for gas chromatography coupled to mass spectrometry (GC–MS) data. The method utilizes parallel factor analysis (PARAFAC) with two-dimensional GC–MS data when sample replicates are aligned and stacked in series to create a three-dimensional data cube for mathematical peak deconvolution and 12C and 13C contribution isolation, with the intent of increasing the accuracy and precision of quantitative metabolomics and 13C flux analysis. The platform is demonstrated with 13C-labeled metabolite extracts, generated via biosynthesis, added as an internal standard to unlabeled 12C metabolites extracted from the methanol-utilizing bacterium Methylobacterium extorquens AM1. Eleven representative metabolites that are common targets for flux analysis were chosen for validation. Good quantitative accuracy and precision were acquired for a 5.00μM known metabolite concentration (for the 11 metabolites), with an average predicted concentration of 5.07μM, and a RSD range of 1.2–13.0%. This study demonstrates the ability to reliably deconvolute 12C-unlabeled and 13C-labeled contributions for a given metabolite. Additionally, using this chemical analysis platform, a dynamic flux experiment is presented in which the incorporation of 13C-labeled cell extract can be detected in the methane-utilizing bacterium Methylosinus trichosporium OB3b and measured temporally. 


Reagent Solvent Reservoir Kits



JM Science’s  new  HPLC Solvent Reservoir Kits are now available in four sizes: 1000ml, 2L, 500 ml, and 5000 ml. 

1) The 1000 ml comes with a 1L solvent reservoir, cap and Teflon insert for 1/8” OD tubing, 1 meter 1/8” OD PTFE tubing and 10 µm 316 stainless steel frit.

2) The 2L comes with 2L bottle, cap and Teflon insert for 1/8” OD tubing, 1 meter PTFE tubing and 10µm 316 stainless steel solvent frit.

3) The 500 ml comes with 0.5L bottle, cap and Teflon insert for 1/16” OD PTFE tubing and 40µm 316 stainless steel solvent frit. This kit is typically used for the HPLC autosampler wash function.

4) The 5000 ml comes with 5L bottle, cap and Teflon insert for 1/8” tubing, 1 meter 1/8” OD PTFE tubing and 10µm 316 stainless steel frit.

All of these HPLC Solvent Reservoir Kits are in stock and ready to ship. Additional accessories for these kits may be purchased separately to meet inventory needs.

For more information contact us at 1-800-495-1678 or visit us at www.jmscience.com

Thursday, 3 May 2012

GOW-MAC Instrument Co. Achieves ISO 9001:2008 Quality System Certification


GOW-MAC® Instrument Co., Bethlehem, PA-based manufacturer of gas chromatographs and gas analyzers, has received ISO 9001:2008 certification by way of BSI Group America Inc. (BSI), a leading global provider of ISO-standards-based assurance, compliance, and information solutions. Frank Rocchino, Director of Compliance and Documentation at GOW-MAC, explains, "GOW-MAC has been producing high-precision analytical instrumentation for over 75 years, so the concept of ‘quality’ is certainly something that was a fundamental component of our culture. However, conforming an entire company's Quality Management System to meet the stringent ISO 9001:2008 Standard requires a total commitment from the entire company. We were fortunate to have unwavering support from top management, as well as an enthusiastic response from the employees during the entire process. Without both of those, this project would've been impossible."

During a company celebration, Jeffrey Lawson, President/CEO recognized the GOW-MAC team, saying that, "This is a very important accomplishment for GOW-MAC. I am very proud of our employees. They are the ones that really made the ISO 9001:2008 registration possible with a tremendous amount of hard work and dedication. This is a clear sign to our customers that GOW-MAC is committed to continually improving our quality management system in order to meet their needs and the needs of evolving analytical markets."

Ken Fincke, Vice President of Sales and Marketing at GOW-MAC, added, “Those manufacturers seeking to access new markets largely need ISO 9001:2008 accreditation in place to do so. The certification allows us to move quickly on to the next phase of our product development.”

About GOW-MAC Instrument Co. — GOW-MAC Instrument Co. is a leading manufacturer of high quality, high performance laboratory and process analytical instruments. Our precision gas chromatographs and gas analyzers are used throughout the world by a wide variety of customers and are engineered for user-specified applications in compressed gas, chemical analysis, general and research laboratory, and educational applications.  For more information, visit www.gow-mac.com.

NEW Advanced Electroporation System for Vaccine Development

The New AgilePulse® In Vivo Electroporation System possesses unique, variable pulse amplitude technology for vaccine delivery or gene therapy applications.

Patented Pulse Agile™ waveforms consist of multiple, low to high voltage pulses with variable pulse lengths, which promotes greater cell membrane poration; resulting in maximum transfection efficiency with minimal damage to the cells or tissues. Gene expression in skin is 100-fold higher1 when delivery is enhanced by electroporation compared to injection alone.
Features:
  • Patented Pulse Agile® technology
  • Resistance measurement for proper needle placement and reproducibility
  • Specially designed needle arrays for intra-muscular or intra-dermal applications
Benefits:
  • Enhanced immune response1
  • Increased Ag-specific T-cell response1
  • Gene expression is 100-fold higher1
Visit the BTX website at www.btxonline.com for more information on products, protocols or to view video tutorials for a variety of applications.
To learn more about this exciting new technology or other BTX electroporation or electrofusion products, contact:
These new products are available exclusively through BTX Harvard Apparatus and Harvard Apparatus Distributors, worldwide. For complete specifications on this exciting new DNA Vaccine Delivery System, go to www.btxonline.com or contact the Harvard Apparatus Technical Support Department at techsupport@btxonline.com