World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Tuesday, 11 June 2013

NEW Pump Heads Built for User-Flexibility

Aalborg® Instruments’ TPU1 and TPU2 Pump Heads provide users the flexibility to connect these models to their own motor or to one purchased from Aalborg®’s catalog.
Each head is mounted on a front panel with an adjustable occlusion wall and safety cover. Installation is quick and easy. Simply attach the pump head to your motor using the existing mounting holes or modify them to fit your needs. TPU Pump Heads are designed for low to high viscosities. Fluids never touch the pump head.
The pump head, the tubing’s inside diameter and the motor’s RPM affect the flow rate.
Design Features:
  • Economical
  • Small footprint
  • 4 rollers (TPU 1) or 10 rollers (TPU 2) to minimize pulsing
  • Stainless steel rollers and shafts
  • Can be mounted in any direction
  • Long tubing life
  • Maximum Lift: 340 in. H2O (12.3 psig)
  • Maximum Suction: 350 in. H2O (12.6 psig)
OEM, laboratory, and processing applications are accommodated.
For additional information, please visit: www.Aalborg.com

Thursday, 6 June 2013

Just Published: Journal of Pharmaceutical and Biomedical Analysis

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Pharmaceutical and Biomedical Analysis
http://rss.sciencedirect.com/publication/science/5266
Selected papers from the latest issue:

New protocol for αAstree electronic tongue enabling full performance qualification according to ICH Q2

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): Miriam Pein , Carolin Eckert , Maren Preis , Jörg Breitkreutz
Performance qualification (PQ) of taste sensing systems is mandatory for their use in pharmaceutical industry. According to ICH Q2 (R1) and a recent adaptation for taste sensing systems, non-specificity, log-linear relationships between the concentration of analytes and the sensor signal as well as a repeatability with relative standard deviation (RSD) values <4% were defined as basic requirements to pass a PQ. In the present work, the αAstree taste sensing system led to a successful PQ procedure by the use of recent sensor batches for pharmaceutical applications (sensor set #2) and a modified measurement protocol. Log-linear relationships between concentration and responses of each sensor were investigated for different bitter tasting active pharmaceutical ingredients (APIs). Using the new protocol, RSD values <2.1% were obtained in the repeatability study. Applying the visual evaluation approach, detection and quantitation limit could be determined for caffeine citrate with every sensor (LOD 0.05–0.5mM, LOQ: 0.1–0.5mM). In addition, the sensor set marketed for food applications (sensor set #5) was proven to show beneficial effects regarding the log-linear relationship between the concentration of quinine hydrochloride and the sensor signal. By the use of our proposed protocol, it is possible to implement the αAstree taste sensing system as a tool to assure quality control in the pharmaceutical industry.

Graphical abstract

image

Comparative analysis of nucleosides and nucleobases from different sections of Elaphuri Davidiani Cornu and Cervi Cornu by UHPLC–MS/MS

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): Fengtao Li , Jin-ao Duan , Dawei Qian , Sheng Guo , Yuhua Ding , Xunhong Liu , Yefei Qian , Yunru Peng , Yijun Ren , Yu Chen
A rapid and sensitive hydrophilic interaction liquid chromatography method was developed for the identification and quantitative determination of 17 nucleosides and nucleobases by using ultra-high performance liquid chromatography separation system coupled to triple quadrupole mass spectrometer. Sufficient separation of the target compounds was achieved on an Acquity BEH Amide column (2.1mm×100mm, 1.7μm) in a single run of 9min. The LOD and LOQ were in the range of 0.017–50.00ngml−1 and 0.056–146.00ngml−1, respectively. Then, the method was applied for the analysis of nucleosides and nucleobases in Elaphuri Davidiani Cornu and Cervi Cornu. Multivariate statistical analysis was also used to investigate the differences in the nucleosides and nucleobases profiles among the samples. The present study also provided helpful information for quality control of Elaphuri Davidiani Cornu and Cervi Cornu.

Graphical abstract

image

Stability of sample solution as a crucial point during HPLC determination of chemical purity of temozolomide drug substance

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): Łukasz Jedynak , Maria Puchalska , Marta Zezula , Marta Łaszcz , Wojciech Łuniewski , Joanna Zagrodzka
An HPLC method for determination of related substances in temozolomide drug substance was developed. Particular attention was paid to the stability studies due to the fact that temozolomide is unstable in a solution and quickly decomposes to its main degradation product 5-amino-4-imidazolecarboxamide (AIC). A mixture of diluted acetic acid and acetonitrile (4:1, v/v) as a diluent guaranteed lowering the decomposition of temozolomide in the solution. As it is not practically possible to fully eliminate the decomposition of temozolomide during an analysis, the mathematical correction of the results was proposed which allows to analyse almost five times more samples per week, comparing to the procedure without the application of the correction. The accuracy of the correction procedure was proved by investigating the recovery of AIC spiked to temozolomide solutions at different levels. Recoveries equalled 90–108% for AIC concentrations contained in the range of 0.30–1.80μgml−1. The developed method was validated according to the current guidelines, proving the suitability of the method for its intended purpose.

Graphical abstract

image

Chemical differentiation of Da-Cheng-Qi-Tang, a Chinese medicine formula, prepared by traditional and modern decoction methods using UPLC/Q-TOFMS-based metabolomics approach

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): Jian-Bo Wan , Xu Bai , Xiu-Jiang Cai , Yi Rao , Yue-Sheng Wang , Yi-Tao Wang
In order to evaluate chemical consistency between traditional and modern decoctions of Da-Cheng-Qi-Tang (DCQT), a classical Chinese medicine formula commonly used in the treatment of digestive diseases, an ultra performance liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q-TOFMS) combined with multivariate statistical analysis was established to globally characterize the chemical profile and discover differentiating chemical markers. Two kinds of decoctions, namely traditional decoction (multi-step decoction of constituent herbs), and modern decoction (one-step decoction of all herbs), were prepared and subjected to UPLC-MS analysis, the datasets of t R–m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis (OPLS-DA) to comprehensively compare the chemical difference between these two kinds of decoction samples. The global chemical difference was found between traditional and modern decoctions, and rhein, sennoside A/B, diosmetin, magnoloside B and naringin were the components contributing most to these differences. Based on the fact that traditional decoction of DCQT presents the higher concentration of rhein and sennoside A/B, mainly contributed to laxative activity of DCQT, the purgative effect of traditional decoction might be more potent, compared with modern decoction. However, the comparative study on purgative effect of traditional and modern DCQT remains to be further investigated using pharmacological approaches. Our findings also provide the early scientific evidence of traditional decoction method of DCQT.

Graphical abstract

image

Real-time in vitro dissolution of 5-aminosalicylic acid from single ethyl cellulose coated extrudates studied by UV imaging

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): Mette Høg Gaunø , Thomas Vilhelmsen , Crilles Casper Larsen , Johan Peter Boetker , Jørgen Wittendorff , Jukka Rantanen , Jesper Østergaard
The purpose of this study was to investigate the in vitro release of 5-aminosalicylic acid from single extrudates by UV imaging and to explore the technique as a visualization tool for detecting film coating defects on extrudates coated with a thin ethyl cellulose layer. 5-Aminosalicylic acid extrudates were film coated with ethyl cellulose in a typical lab system coater equipped with one Wurster partition. Dissolution testing was performed first in a conventional paddle dissolution apparatus and second, in a flow through geometry equipped with a UV imaging system. Selected film coated extrudates from four different coating levels were placed in agarose gels and UV imaging was performed for a total of 240min. Absorbance maps were obtained thus visualizing the release of 5-aminosalicylic acid over time and it was possible to detect a decrease in release as a function of increased ethyl cellulose coating weight gain. Using a calibration curve the released amount was calculated and the individual release profiles for each coating weight gain in general resulted in comparable release profiles. Furthermore, the release profiles were consistent with the dissolution results obtained from the paddle dissolution testing. The release from defect extrudates was visualized by the absorbance maps and the release was highest from the compromised part of the extrudates. UV imaging has proven to be a useful technique to visualize the release of 5-aminosalicylic acid from single film coated extrudates and it has potential for detection of film coating defects.

Graphical abstract

image

Development and validation of a fast chromatographic method for screening and quantification of legal and illegal skin whitening agents

06 June 2013, 09:19:54Go to full article
Publication date: September 2013
Source:Journal of Pharmaceutical and Biomedical Analysis, Volume 83
Author(s): B. Desmedt , V. Rogiers , P. Courselle , J.O. De Beer , K. De Paepe , E. Deconinck
During the last years, the EU market is flooded by illegal cosmetics via the Internet and a so-called “black market”. Among these, skin-bleaching products represent an important group. They contain, according to the current European cosmetic legislation (Directive 76/768/EEC), a number of illegal active substances including hydroquinone, tretinoin and corticosteroids. These may provoke as well local as systemic toxic effects, being the reason for their banning from the EU market. To control this market there is a need for a fast screening method capable of detecting illegal ingredients in the wide variety of existing bleaching cosmetic formulations. In this paper the development and validation of an ultra high pressure liquid chromatographic (UHPLC) method is described. The proposed method makes use of a Waters Acquity BEH shield RP18 column with a gradient using 25mM ammonium borate buffer (pH 10) and acetonitrile. This method is not only able to detect the major illegal (hydroquinone, tretinoin and six dermatologic active corticosteroids) and legal whitening agents, the latter having restrictions with respect to concentration and application (kojic acid, arbutin, nicotinamide and salicylic acid), but can also quantify these in a run time of 12min. The method was successfully validated using the “total error” approach in accordance with the validation requirements of ISO-17025. During the validation a variety of cosmetic matrices including creams, lotions and soaps were taken into consideration.

Graphical abstract

image

JEOL Resonance Introduces New Zero Boil Off Magnet for NMR Systems


JEOL Resonance (Akishima City, Tokyo) has developed a new Nuclear Magnetic Resonance (NMR) super conducting magnet that operates on a minimum amount of liquid helium. The new NMR system will be announced at the 54th Experimental Nuclear Magnetic Resonance Conference (ENC), the largest NMR conference in the US.
JEOL's new NMR system is capable of acquiring high resolution NMR data when liquid helium is scarce. A super conducting magnet is typically cooled with liquid helium to keep its internal coil in the super conducting state and to maintain magnetic field intensity.
The new JEOL Resonance Zero Boil Off magnet will substantially reduce consumption of liquid helium by reliquifying the helium gas generated by evaporation of the helium in the magnet. In the event of a power outage the helium reservoir will maintain the magnetic field for 4 days. The cooling system design allows for biannual maintenance without affecting the high magnetic field of the super conducting magnet and minimizes vibration and noise that can interfere with NMR signals.
   JEOL Resonance offers a line of magnets with a magnetic field intensity ranging from 400 MHz (9.4 T) to 930 MHz (21.8 T). The company plans to incorporate the new technology in the models of higher magnetic field intensities such as 500 MHz (11.7 T) and 600 MHz (14.1 T) to offer a complete line of new NMR systems. Shipments will begin in May 2013.

NMR Used to Study Molecular Structures at the Atomic Level
NMR systems are analytical tools designed to study the molecular structures of substances at the atomic level by measuring extremely weak radio waves. NMR is essential in development of proteins, polymers, drugs, and new materials, and has been utilized in pharmaceutical, biology, food, and chemistry. Recent applications include organic LEDs and battery materials, both of which are new research areas that are growing rapidly.

JEOL RESONANCE Inc.

JEOL RESONANCE, Inc. was established in April 2011 based on the NMR Division that was split from JEOL Ltd., and was financed by Innovation Network Corporation Japan and Japan Superconductor Technology. The company's mission is to develop new technologies, high end products, and new applications.

Drying of Oil, Fuel and Fat Samples

Genevac, world leaders in solvent removal technology, has over 20 year’s experience of supplying evaporators for removal of solvents from oil, fat and fuel samples.

Oils, fats and fuels are normally isolated from natural sources using extraction or separation techniques that present the final sample in a solution of organic solvent. Before analysis such samples must be dried or concentrated.

Whether extracting and recovering additives, evaluating lipid content of foods, characterising reclaimed cooking oils before reprocessing / conversion to biofuels, or investigating drillling test samples - oils, fuels and fats can often prove difficult to dry without using very high temperatures which may lead to loss of the more volatile fractions within the sample.

For many such applications, researchers have found that the Genevac EZ-2 and Rocket Evaporators have significantly enhanced recovery and results.  When working with larger solvent volumes, additional benefit is gained by way of productivity savings when using Genevac evaporators with SampleGenie technology which enables large volumes to be concentrated or dried directly into a small vial. 

Many oil and fat analyses require use of potentially explosive solvents, such as di-ethyl ether.  These can be safely evaporated in Genevac systems fitted with the Inert Gas Purge option, which removed all the air from the system before use, replacing it with inert gas and thereby preventing incident.

For further information including access to a series of technical papers describing Genevac evaporators being used for drying of oils, fats and fuels please visit http://www.genevac.com/en/Application.asp?S=10&V=1&Page=97 or contact the company on +44-1473-240000 / salesinfo@genevac.co.uk

Wednesday, 5 June 2013

Just Published: Journal of Chromatography B

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Selected papers from the latest issue:

Determination of deltonin in rat plasma by using HPLC–MS/MS and the application of this method in pharmacokinetic studies

05 June 2013, 09:36:17
Publication date: 15 July 2013
Source:Journal of Chromatography B, Volume 931
Author(s): Dan Du , Bo Gao , Guang Xin , Aimin Sun , Baozhan Huang , Rui Zhang , Zhihua Xing , Qianming Chen , Yang He , Wen Huang
Deltonin is a naturally occurring spirostanol glycoside from Dioscorea zingiberensis C.H. Wright, which is used in traditional Chinese medicine. It exerts strong cytotoxic effect on C26 cells, inhibits C26 derived-tumor growth, and prolongs the survival of tumor-bearing mice after its oral administration, indicating its potential for use as an anti-tumor drug. To investigate the pharmacokinetic profiles of deltonin, a rapid, sensitive, and simplified high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) assay was developed and validated for the determination of deltonin in rat plasma. After acetonitrile-mediated plasma protein precipitation, chromatographic separation of deltonin was achieved using a reversed phase Hypersil Gold column (150mm×2.1mm, 5μm), with gradient elution using 0.1% formic acid and acetonitrile. Thereafter, deltonin was quantified using MS/MS with electrospray ionization (ESI) in positive multiple reaction monitoring (MRM) mode. The flow rate of the mobile phase was 200μL/min, and the retention time was 9.03min for deltonin and 6.31min for the internal standard (IS: 20(S)-ginsenoside Rb1). The linear range of the calibration curve was 2–5000ng/mL (r 2 >0.99), and the limit of detection (LOD) was 0.46ng/mL. The intra- and inter-day accuracies ranged from −2.8% to 11.1% and precisions (RSD) were within 13.1%. Deltonin was found to be stable under short-term temperature conditions, post-preparative temperature conditions, and after 3 freeze–thaw cycles conditions. The validated method was successfully applied to a pharmacokinetic study in rats after oral administration of deltonin (50 and 100mg/kg). The pharmacokinetics is characterized by high apparent clearance (CL/F) and apparent volume of distribution (Vd/F).

Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography–tandem mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Chun-Ru Cheng , Min Yang , Shu-Hong Guan , Xiao-Hui Wu , Xiao-Yan Pang , Yang Wang , Yi Yang , Jie Ding , De-An Guo
The present study aims to investigate the pharmacokinetics of ganoderic acid D (GD), a representative active triterpenoid from Ganoderma lucidum. A sensitive and selective liquid chromatography–tandem mass spectrometry method was developed for the simultaneous determination of the concentrations of GD and its main metabolite (ganoderic acid B) in rat plasma. Following protein precipitation, the analytes were separated on a reversed-phase C18 column. Acetonitrile–water–acetic acid (40:60:0.01) was used at a flow-rate of 0.2ml/min. A triple quadrupole mass spectrometer equipped with an electrospray ionization source was used as the detector and was operated in the negative ion mode. Multiple reaction monitoring using the characteristic transitions was performed to quantify the analytes. The method had a lower limit of quantification of 8.19ng/ml for GD, and 8.59ng/ml for ganoderic acid B (GB). The calibration curves were demonstrated to be linear over the concentration range of 8.19–4096ng/ml and 8.59–2149ng/ml, respectively. Variations within- and between-batch were less than 6.4% and 4.6%, respectively. The extraction recovery rates ranged from 98.8 to 105.2% and 100.7 to 113.6%, respectively. The validated method was successfully applied to the quantification of GD and GB concentrations in rat plasma after oral administration (or intravenous administration) of GD preparations at a dose of 15mg/kg. The data showed that the absolute bioavailability increased from 22% to 70% after the GD suspension was changed to GD loaded solid lipid nanoparticles. In the meantime, the C max increased from 107.2 to 1555.6ng/ml; the t max changed from 2.0h to 0.3h. These results are very helpful in the further studies.

Quantitative analysis of autoinducing peptide I (AIP-I) from Staphylococcus aureus cultures using ultrahigh performance liquid chromatography–high resolving power mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Hiyas A. Junio , Daniel A. Todd , Keivan A. Ettefagh , Brandie M. Ehrmann , Jeffrey S. Kavanaugh , Alexander R. Horswill , Nadja B. Cech
Staphylococcus aureus infections acquired in hospitals now cause more deaths per annum in the US than does HIV/AIDS. Perhaps even more alarming is the rise in community associated methicillin-resistant S. aureus (CA-MRSA) infections, which have spread out of hospital settings and are infecting otherwise healthy individuals. The mechanism of enhanced pathogenesis in CA-MRSA remains unclear, but it has been postulated that high activity in the agr quorum-sensing system could be a contributing factor. The purpose of this study was to develop a quantitative method for analysis of autoinducing peptide I (AIP-I), the activating signal for the agr system in S. aureus. An effective method was developed using ultrahigh performance liquid chromatography (UHPLC) coupled to electrospray ionization mass spectrometry with an LTQ Orbitrap mass spectrometer. Relying on the exceptional resolving power and mass accuracy of this instrument configuration, it was possible to quantify AIP-I directly from the complex growth media of S. aureus cultures with a limit of detection (LOD) of 0.25μM and a linear dynamic range of 2.6 to 63μM. The method was then employed to monitor time-dependent production of AIP-I by S. aureus cultures, and it was observed that AIP-I production reached a maximum and leveled off after approximately 16h. Finally, it was determined that virulence of S. aureus was correlated with AIP-I production in some (but not all) strains analyzed.

Para-aminobenzamidine linked regenerated cellulose membranes for plasminogen activator purification: Effect of spacer arm length and ligand density

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Ezio Fasoli , Yiaslin Ruiz Reyes , Osiris Martinez Guzman , Alexandra Rosado , Vivian Rodriguez Cruz , Amaris Borges , Edmarie Martinez , Vibha Bansal
Despite membrane-based separations offering superior alternative to packed bed chromatographic processes, there has been a substantial lacuna in their actual application to separation processes. One of the major reasons behind this is the lack of availability of appropriately modified or end-group modifiable membranes. In this paper, an affinity membrane was developed using a commercially available serine protease inhibitor, para-aminobenzamidine (pABA). The membrane modification was optimized for protein binding capacity by varying: (i) the length of the spacer arm (SA; 5-atoms, 7-atoms, and 14-atoms) linking the ligand to membrane surface; (ii) the affinity ligand (pABA) density on membrane surface (5–25nmol/cm2). Resulting membranes were tested for their ability to bind plasminogen activators (PAs) from mono- and multi-component systems in batch mode. The membrane containing pABA linked through 7-atoms SA but similar ligand density as in the case of 5- or 14-atoms long SA was found to bind up to 1.6-times higher amounts of PA per nmoles of immobilized ligand from conditioned HeLa cell culture media. However, membranes with similar ligand densities but different lengths of SA, showed comparable binding capacities in mono-component system. In addition, the length of SA did not affect the selectivity of the ligand for PA. A clear inverse linear correlation was observed between ligand density and binding capacity until the point of PA binding optima was reached (11±1.0nmol/cm2) in mono- and multi-component systems for 7- as well as 14-atoms SA. Up to 200-fold purification was achieved in a single step separation of PA from HeLa conditioned media using these affinity membranes. The issues of ligand leaching and reuse of the membranes were also investigated. An extensive regeneration procedure allowed the preservation of approximately 95% of the PA binding capacity of the membranes even after five cycles of use.

Rapid multi-method for the determination of growth promoters in bovine milk by liquid chromatography–tandem mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): George Kaklamanos , Georgios Theodoridis
A rapid multi-method was developed for the determination of 21 growth promoters from different classes, including gestagens, corticosteroids, RALs, stilbenes, steroids in bovine milk by liquid chromatography–tandem mass spectrometry (LC–MS/MS). All compounds were eluted from the analytical column in less than 8.5min and were subsequently analyzed with atmospheric pressure chemical ionization (APCI) using both positive and negative mode. Sample preparation included extraction of the compounds with acetonitrile and purification with solid-phase extraction (SPE). The method was validated according to Commission Decision 2002/657/EC, at a validation level of 1ng/ml. The specificity, accuracy, precision, decision limit (CCα) and the detection capability (CCβ) were satisfactory evaluated. The recoveries ranged from 80.7% to 118.8% and reproducibility represented as coefficient of variance (CV) was from 1.8% to 13.0%. The CCα and CCβ values were in the ranges 0.06–0.10ng/ml and 0.11–0.17ng/ml, respectively. The developed method was applied in real samples proving its rapidness and sensitivity for the determination of the 21 growth promoters.

Detection and quantification of quinolone signalling molecule: A third quorum sensing molecule of Pseudomonas aeruginosa by high performance-thin layer chromatography

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Anju Bala , Ravi Kumar Gupta , Sanjay Chhibber , Kusum Harjai
Sophisticated network of quorum sensing involves the production of chemical signals which regulate the combined expression of virulence genes and biofilm formation in Pseudomonas aeruginosa. Two well-characterized acyl homoserine lactone based las and rhl systems together with alkyl quinolone based Pseudomonas quinolone signalling (PQS) are fundamental components of this network. Third signalling molecule, 2-heptyl-3-hydroxy-4-quinolone (PQS) is of paramount importance because of its interconnecting role in quorum sensing hierarchy in P. aeruginosa. Accurate detection of PQS molecule is very important to understand the involvement of this system in infection process of P. aeruginosa. In this study, high performance-thin layer chromatography (HP-TLC) method was developed for detection as well as quantification of PQS signal molecules in P. aeruginosa, which combines conventional method like TLC with sophisticated instrumentation. This method was validated using parameters like linearity, accuracy, precision, reproducibility and sensitivity. Intra- and inter-day accuracy and precision values were determined which were found to be within acceptable level and hence showed reproducibility. Measurement of PQS in the range of 0.01nmol indicated excellent sensitivity of this approach for quantifying PQS molecule. Automated sampling, rapid and simultaneous analysis of large number of samples and minimal errors make this method more suitable for analysis of PQS signalling molecules. Production of PQS was found to be strain dependent since variation in amount of PQS was observed among different P. aeruginosa isolates. Further, PQS production was also dependent on growth phase of P. aeruginosa with maximum production in late stationary phase.

An improved GC–MS method in determining glycerol in different types of biological samples

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Yixiao Shen , Zhimin Xu
Glycerol is an important compound participating in the lipid metabolism and energy conversion of body. Its level, especially in the blood circulation, has been considered as an index in assessing the triglycerides level, fat mobilization and potential risk of hyperlipidemia. In this gas chromatography mass spectrometry (GC–MS) method, 1,2,3-butanetriol was selected as an internal standard instead of isotope labeled glycerol. The internal standard and sample were derivatized by trimethylsilyl imidazole. The glycerol and internal standard derivatives in the sample were measured by a selected ion monitor mode of GC–MS. The sensitivity and repeatability of this method were examined by analyzing glycerol in eleven different types of biological tissue and fluid samples. The glycerol level in the measured mouse plasma sample was at 11.71±0.48μg/mL, while it was in a range of 0.15±0.01 (brain) to 0.39±0.02μg/mg (liver) in the tissue samples. It was 27.06±0.12 and 1.60±0.04μg/mL in the tested human blood and urine samples, respectively. Also, the glycerol recoveries of all samples were higher than 80% and over 90% for the fluid samples, especially. With the satisfactory repeatability and recovery and non-isotope internal standard, the GC–MS method could be a reliable technique in monitoring the glycerol status of biological samples regardless of whether they are from a study in which isotope labeled glycerol or other stable isotope materials were involved.

Determination of nitrite and nitrate in cerebrospinal fluid by microchip electrophoresis with microsolid phase extraction pre-treatment

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Peter Troška , Richard Chudoba , Ladislav Danč , Róbert Bodor , Michal Horčičiak , Eva Tesařová , Marián Masár
A new method for the determination of nitrite and nitrate, indicators of various neurological diseases (meningitis, multiple sclerosis, Parkinson's disease) in cerebrospinal fluid (CSF) on an electrophoresis chip was developed. An on-line combination of isotachophoresis (ITP) with capillary electrophoresis (CE) on a poly(methylmethacrylate) chip assembled with coupled separation channels (CC) and contact conductivity detectors was employed. ITP separations performed at low pH (3.6) in the first separation channel enabled a highly selective transfer of the analytes to the second CE stage working under micellar conditions implemented by zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)-propanesulfonate. The proposed method achieved low limits of detection varied from 0.2 to 0.4μgL−1 when the sample volume injected onto the chip (9.9μl) was almost the same as the volume of both separation channels. Preferable working conditions on the CC chip (suppressed hydrodynamic and electroosmotic flow) contributed for reproducible migration velocities (intra-day reproducibility up to 2.1% RSD) and determinations of trace concentrations of nitrite and nitrate (intra-day precision up to 3.0% RSD). Huge amount of chloride present in CSF (approx. 4.5gL−1) was removed from analyzed CSF samples by microsolid phase extraction performed on silver-form resin prior to the ITP-CE analysis. Developed method provided fast (approx. 20min total analysis time) and reliable determinations of trace nitrite and nitrate and could be fully integrated into the analysis of CSF samples.

On-line screening of matrix metalloproteinase inhibitors by capillary electrophoresis coupled to ESI mass spectrometry

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Xu Wang , Zhiying Dou , Yaozuo Yuan , Shuli Man , Kris Wolfs , Erwin Adams , Ann Van Schepdael
Capillary electrophoresis (CE) with the use of mass spectrometry (MS) has been considered as a unique tool for microscale enzyme assay and inhibitor screening. In this study, matrix metalloproteinase-9 (MMP-9) was selected as target enzyme due to its important role in tumor invasion and metastasis. In order to define the optimal MS parameters, a two level half fraction factorial experimental design was performed. A background electrolyte consisting of 20mM ammonium acetate (pH 6.8) and a sheath liquid of water–methanol (50:50, v/v) containing 0.05% formic acid at a flow rate of 4μl/min were selected. This system was operated in the positive ion mode with a detection-limit of 10nM for the MMP reaction product and provided 60 folds enhancement of sensitivity by using selected reaction monitoring detection compared with MS full scan mode, which significantly increased the detectability of the system and therefore reduced the enzyme reaction time in both off-line and in-line mode. Both electrophoretically mediated microanalysis and pressure mediated microanalysis combined with MS detection were investigated for MMP inhibitor screening. Good repeatability (RSD of peak area and migration time were lower than 5.0%) and linearity (R 2 >0.996) were obtained for both in-capillary approaches. Several tetracycline antibiotics and natural products were selected to test the system. The results indicated an agreement on the ranking of inhibitory potency for both in-capillary approaches.

Semi-preparative isolation of dihydroresveratrol-3-O-β-d-glucuronide and four resveratrol conjugates from human urine after oral intake of a resveratrol-containing dietary supplement

05 June 2013, 09:36:17
Publication date: 1 July 2013
Source:Journal of Chromatography B, Volume 930
Author(s): Yulia Radko , Kathrine B. Christensen , Lars P. Christensen
A method for semi-preparative isolation of major resveratrol metabolites from human urine after oral intake of a trans-resveratrol-containing dietary supplement was developed. Pretreatment of the urine (6L) by using solid-phase extraction gave a brown oily residue (9.3g), which was separated using a combination of normal phase column chromatography and reversed-phase flash column chromatography resulting in fractions containing 1.1g crude trans-resveratrol-3-O-sulfate (M1), 86mg of a crude mixture of trans-resveratrol-3,5-O-disulfate (M2) and trans-resveratrol-3,4′-O-disulfate (M3), and 568mg of a crude mixture of trans-resveratrol-3-O-β-d-glucuronide (M4) and dihydroresveratrol-3-O-β-d-glucuronide (M5). Purification of the crude metabolites was performed by semi-preparative reversed-phase HPLC using a gradient of aqueous ammonium acetate (2.5mmol/L, pH 6.7)/acetonitrile for purification of M1, M2 and M3 or trifluoroacetic acid in water (pH 2.5)/acetonitrile for purification of M4 and M5. From a part of the crude metabolites (50–75mg), 47mg M1 (purity 98.7%), 14mg M2 (purity 96.1%), 10mg M3 (purity 96.3%), 38mg M4 (purity 98.2%) and 18mg M5 (purity 97.8%) were obtained. The structures of all isolated resveratrol metabolites were elucidated by spectroscopic and spectrometric methods such as 1D and 2D NMR, UV, and LC–MS. This method represents a novel approach to obtain resveratrol metabolites being the first method describing the direct isolation of pure resveratrol metabolites from urine samples in quantities sufficient for full chemical characterization and testing in vitro and in preclinical trials. 

Extended Mass Spec Imaging Services Now Available

Protea Biosciences, a leading developer of innovative bioanalytical products and services, announced today the release of an extended mass spectrometry imaging (MSI) service offering from the Mass Spec Imaging Center (MSIC™). This new service portfolio offers advanced MSI services using Protea’s proprietary LAESI DP-1000 Direct Ionization System as well as MALDI (Matrix-Assisted Laser Desorption/Ionization) mass spectrometry for a wide variety of sample types and applications.
“This new portfolio of services offers researchers an opportunity to ‘detect’ where their molecules of interest reside in a biological matrix,” said Alessandro Baldi PhD, Protea’s Vice President and General Manager. “This spatial information offers critical insight for researchers working in the fields like metabolomics, biomarker discovery, drug discovery, and histopathology.”
To highlight this extended service portfolio, Protea announced a Spring Webinar Series, which discusses various applications and technologies for mass spectrometric imaging. These webinars cover topics ranging from biomarker discovery to drug distribution profiling and in vivo applications using the LAESI technology.
The MSIC also serves as a demonstration and training facility to help researchers learn more about mass spectrometry imaging using the tools and techniques developed at Protea.

For complete details on the Protea MSIC and the Spring Webinars, go to: https://proteabio.com/imaging

Entry Level Thermal Plate Sealer

The MicroSeal from Porvair Sciences is a manual microplate heat sealer designed to be compact, easy-to-use and offer great performance all with an affordable list price.

Of the various methods of sealing microplates, heating sealing has become the preferred option for many labs as it creates an air tight and chemically-resistant seal without the complications of adhesives being applied to a plate. Incorporating a unique ergonomic pull down mechanism makes single action heat sealing of a wide range of plates on the MicroSeal quick and simple.

Using a pre-set temperature of 170°C, ideal for most common sealing applications, and dual LED status display of power and heating, the MicroSeal is very safe and easy to use. A built-in thermostat prevents overheating of plates.

With its small footprint, ease of use and ability to handle a wide range of plates the MicroSeal is the obvious choice for laboratories looking for an affordable manual thermal plate sealer.

Porvair Sciences Ltd has specialised in the manufacture of microplates and microplate equipment since its formation in 1992. Via its global distributor network, Porvair Sciences serves Life Sciences, Biotechnology, R&D and Molecular Biology with microplate solutions for all applications, from sample preparation to high throughput screening.  Porvair Sciences is a subsidiary of Porvair plc, a world leader in microporous materials.

For further information on the MicroSeal please contact Porvair Sciences on telephone +44-1372-824290, email int.sales@porvair-sciences.com or visit the website at http://www.porvair-sciences.com/en/services-menu/equipment/microseal-manual-thermal-plate-sealer/