World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Thursday, 26 April 2012

New Managing Director for Oxford Instruments Plasma Technology

Oxford Instruments Plasma Technology has just announced the appointment of Dan Ayres to Managing Director with immediate effect. Dan previously held the position of General Manager at the company, and prior to this was Operations Director. With over 10 years experience within the Oxford Instruments Group, Dan has held roles in the fields of Operations, Product Management and Project Management.

Dan Ayres will report to Jonathan Flint, CEO of Oxford Instruments plc, who comments, “Our business strategy demands an organisation that can meet the challenge of expanding markets, new products, and growing numbers of customers and employees. Dan’s new appointment will ensure that Oxford Instruments Plasma Technology continues its current growth plans, and I am confident that with Dan heading the strong Executive Team in place at the company, this will be achieved.”

“I am delighted to have this opportunity to lead our highly skilled team and I look forward to working with them to build on the success of recent years”, comments Dan Ayres, “In line with our strategic plan we will focus on innovating improved etch, deposition and growth solutions to meet our customers’ needs for new systems, continuous performance improvement and after-sales support. We will support our focus on innovation by investing in improved business processes to ensure we deliver a healthy and growing business for our employees, shareholders and other stakeholders”
At the same time, Mark Vosloo, Sales & Customer Support Director has taken over responsibility for all customer facing functions including strategic marketing and holds the new title Sales, CS & Marketing Director. This promotion will ensure that Oxford Instruments Plasma Technology aligns even more effectively with our customers and the provision of high technology products and services geared to their specific requirements. 

Portable, Cost Effective Flexible Film Isolator


Air Science provides containment solutions to meet any analytical need.
The NEW Purair Flex provides numerous performance advantages over the competition, including:
More Volume.
The Purair Flex Film Isolator features an innovative curved film design that provides more working volume than any other Glove Bag on the market.


Versatile Tapered
Sleeve / Glove Options.

Unlike other glove bags, the double O-ring design on the standard polyurethane cuffs allow users to quickly and easily change gloves to meet a variety of dexterity needs.
Easy Setup.
Semi-rigid support rods make the Purair Flex easy to setup up and provides increased stability, even if the bag is not inflated to full pressure.
Safety Options.
HEPA filter availability, Bag-in / Bag-out Port, and optional
nitrogen purge inlet connections offer the reliability and safety today’s analysts need.
The Purair Flex is 23.6" W x 24.6" D x 23.6" H. For complete specifications go to www.airscience.com. 

Wednesday, 25 April 2012

Euroanalysis XVII


The Polish Chemical Society, the Committee on Analytical Chemistry Polish Academy of Sciences and the local organizers, the Warsaw University of Technology and the University of Warsaw, has announced the XVIIth edition of Euroanalysis, the European Conference on Analytical Chemistry, which will be held in Warsaw, Poland, 25-29 August 2013.

All important information about the XVIIth Euroanalysis conference "Analytical chemistry for human well-being and sustainable development" can be found at the web-page http://www.euroanalysis2013.pl/

The venue of the Euroanalysis 2013 is a large complex of auditoria in the Main Building of the Warsaw University of Technology, the oldest technical university in Poland  with the long tradition dating back to 1826. Plenary sessions will be held in the Great Hall of the Main Building of the Warsaw University of Technology, located in a central part of Warsaw – an area well served by road links and public transport. We hope that the Euroanalysis 2013 will be a great opportunity to share new scientific achievements.

Just Published: Analytica Chimica Acta

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Determination of trace elements in lithium niobate crystals by solid sampling and solution-based spectrometry methods

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
László Bencs, Krisztina György, Márta Kardos, János Osán, Bálint Alföldy, Imre Varga, Zsolt Ajtony, Norbert Szoboszlai, Zsolt Stefánka, Éva Széles, László Kovács
Solid sampling (SS) graphite furnace atomic absorption spectrometry (GFAAS) and solution-based (SB) methods of GFAAS, flame atomic absorption spectrometry (FAAS), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) were elaborated and/or optimized for the determination of Cr, Fe and Mn trace elements used as dopants in lithium niobate optical crystals. The calibration of the SS-GFAAS analysis was possible with the application of the three-point-estimation standard addition method, while the SB methods were mostly calibrated against matrix-matched and/or acidic standards. Spectral and non-spectral interferences were studied in SB-GFAAS after digestion of the samples. The SS-GFAAS method required the use of less sensitive spectral lines of the analytes and a higher internal furnace gas (Ar) flow rate to decrease the sensitivity for crystal samples of higher (doped) analyte content. The chemical forms of the matrix produced at various stages of the graphite furnace heating cycle, dispensed either as a solid sample or a solution (after digestion), were studied by means of the X-ray near-edge absorption structure (XANES). These results revealed that the solid matrix vaporized/deposited in the graphite furnace is mostly present in the metallic form, while the dry residue from the solution form mostly vaporized/deposited as the oxide of niobium.

Graphical Abstract

image

Graphical abstract Highlights

► Solid sampling GFAAS was studied for Cr, Fe and Mn determination in lithium niobate. ► Solution based GFAAS, FAAS, ICP-OES and ICP-MS were elaborated for method validation. ► The performances of the elaborated spectrochemical methods have been compared. ► The chemical forms of the matrix produced in GFAAS cycles were studied by XANES.

Alignment and clustering strategies for GC×GC–MS features using a cylindrical mapping

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Jos J.A.M. Weusten, Eduard P.P.A. Derks, John H.M. Mommers, Sjoerd van der Wal
Comprehensive two-dimensional gas chromatography coupled to mass spectrometry is a powerful tool to analyze complex samples. For application of the technique in studies like biomarker discovery in which large sets of complex samples have to be analyzed, extensive preprocessing is needed to align the data obtained in several injections (analyses). We developed new alignment and clustering algorithms for this type of data. New in the current procedures is the consistent way in which the phenomenon referred to as wrap-around is treated. The data analysis problems associated with this phenomenon are solved by treating the 2D display as the surface of a three-dimensional cylinder. Based on this transformation we developed a new similarity metric for features as a function of both the cylindrical distance (reflecting similarity in chromatographic behavior) and of the mass spectral correlation (reflecting similarity in chemical structure). The concepts are used in warping and clustering, and include a protection against greedy warping. The methods were applied – for the purpose of an example – to the analysis of 11 replicates of a human urine sample concentrated by solid phase extraction. It is shown that the alignment is well protected against greedy warping which is important with respect to analytical qualities as robustness and repeatability. It is also demonstrated that chemically similar features are clustered together. The paper is organized as follows. First a brief introduction is provided addressing the background of the GC×GC–MS data structure followed by a theoretical section with a conceptual description of the procedures and details of the algorithms. Finally an example is given in the experimental section, illustrating the application of the procedures.

Graphical Abstract

image

Graphical abstract Highlights

► Data preprocessing is an important but complex step for analysis of GC×GC–MS data. ► We developed a strategy to deal with the phenomenon known as wrap-around. ► We developed a similarity measure for features based on GC×GC and MS information. ► We developed a concept to identify non-specific features. ► We developed an alignment procedure based on cluster analysis.

A layered magnetic iron/iron oxide nanoscavenger for the analytical enrichment of ng-L−1 concentration levels of heavy metals from water

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Andreas E. Karatapanis, Dimitrios E. Petrakis, Constantine D. Stalikas
Magnetically driven separation techniques have received considerable attention in recent decade because of their great potential application. In this study, we investigate the application of an unmodified layered magnetic Fe/Fe2O3 nanoscavenger for the analytical enrichment and determination of sub-parts per billion concentrations of Cd(II), Pb(II), Ni(II), Cr(VI) and As(V) from water samples. The synthesized nanoscavenger was characterized by BET, TGA, XRD and IR and the parameters influencing the extraction and recovery of the preconcentration process were assessed by atomic absorption spectrometry. The possible mechanism of the enrichment of heavy metals on Fe/Fe2O3 was proposed, which involved the dominant adsorption and reduction. The nanoscale size offers large surface area and high reactivity of sorption and reduction reactions. The obtained limits of detection for the metals studied were in the range of 20–125ngL−1 and the applicability of the nanomaterial was verified using a real sample matrix. The method is environmentally friendly as only 15mg of nanoscavenger are used, no organic solvent is required for the extraction and the experiment is performed without the need for filtration or preparation of packed preconcentration columns.

Graphical Abstract

image

Graphical abstract Highlights

► A layered magnetic Fe/Fe2O3 nanomaterial is prepared. ► Analytical enrichment of selected heavy metals on Fe/Fe2O3 nanoparticles. ► The mechanism of enrichment involves the adsorption and reduction. ► The applicability of the nanomaterial is verified using a real sample matrix.

Determination of perfluorocarboxylic acids in water by ion-pair dispersive liquid–liquid microextraction and gas chromatography–tandem mass spectrometry with injection port derivatization

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Wen-Lin Liu, Yen-Chen Ko, Bao-Huey Hwang, Zu-Guang Li, Thomas Ching-Cherng Yang, Maw-Rong Lee
A novel technique for derivatization in a gas chromatograph injection port after a one-step extraction of trace perfluorocarboxylic acids (PFCAs) in water with ion pair formation during dispersive liquid–liquid microextraction (DLLME) was investigated. Tetrabutylammonium hydrogen sulfate (TBAHS) was used as the ion pair reagent. PFCA butyl ester derivatives were formed in the GC injection port and then analyzed using gas chromatography coupled to tandem mass spectrometry with negative chemical ionization. According to our analysis, the operative linear range for PFCA detection from 250pgmL−1 to 2μgmL−1 with a relative standard derivation (RSD) below 13%. Detection limits were achieved at the level of 37–51pgmL−1. This method was successfully applied for the analyzing of PFCAs in river water samples from urban and industrial areas without tedious pretreatment. The concentration range over which PFCAs were detected is from 0.6ngmL−1 to 604.9ngmL−1.

Graphical Abstract

image

Graphical abstract Highlights

► One-step extraction of perfluorocarboxylic acids in aqueous was investigated. ► Quantitation was performed by using GC–NCI-MS/MS. ► The detection limits were picogram per milliliter level for all PFCAs analyses.

Incorporation of methamphetamine and amphetamine in human hair following controlled oral methamphetamine administration

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Aldo Polettini, Edward J. Cone, David A. Gorelick, Marilyn A. Huestis
Background Although hair testing is well established for the assessment of past drug exposure, uncertainties persist about mechanisms of drug incorporation into hair and interpretation of results. The aim of this study was to administer methamphetamine (MAMP) under controlled conditions as a model drug to investigate drug incorporation into human hair. Material and methods Seven volunteers with a history of stimulant use received 4×10mg (low) doses of sustained release S-(+)-MAMP HCl within 1 week, with weekly head hair samples collected by shaving. 3 weeks later, 4 of them received 4×20mg (high) doses. After extensive isopropanol/phosphate buffer washing of the hair, MAMP and its metabolite amphetamine (AMP) concentrations were determined in all weekly hair samples by LC–MS–MS in selected reaction monitoring mode with the undeca- and deca-deuterated drugs, respectively, as internal standards (LLOQ, 0.005ngmg−1). Results MAMP T max occurred from 1 to 2 weeks after both doses, with C max ranging from 0.6 to 3.5ngmg−1 after the low and 1.2 to 5.3ngmg−1 after the high MAMP doses. AMP C max in hair was 0.1–0.3ngmg−1 and 0.2–0.5ngmg−1, respectively, for low and high doses. Highly dose-related concentrations within subjects, but large variability between subjects were observed. MAMP concentrations were above the 0.2ngmg−1 cut-off for at least 2 weeks following administration of both low and high doses. The overall AMP/MAMP ratio ranged from 0.07 to 0.37 with a mean value of 0.15±0.07, and a median of 0.13. The percentage of MAMP and AMP removed with the washing procedure decreased with time after administration. A strong correlation was found between area under the curve of MAMP (r 2 =0.90, p =0.00) and AMP (r 2 =0.94, p =0.00) concentrations calculated for the 3-week period following administration and the total melanin concentration in hair. Significant correlations were observed also between C max and melanin. Conclusions This study demonstrated that despite large inter-individual differences, the incorporation of MAMP and AMP into hair is dose-related with much of the observed scatter of MAMP and AMP concentrations explained by melanin concentration in hair.

Graphical Abstract

image

Graphical abstract Highlights

► We studied in vivo incorporation of methamphetamine in human head hair. ► Methamphetamine (40 and 80mg) was administered under controlled conditions. ► Methamphetamine and amphetamine incorporation was followed for 3 weeks. ► Influence of various factors (e.g. pre-analytical washing, melanin) was studied. ► Criteria to ascertain MAMP use based on MAMP/AMP ratio and AMP cut-off are proposed.

2-Aminopurine hairpin probes for the detection of ultraviolet-induced DNA damage

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Amira F. El-Yazbi, Glen R. Loppnow
Nucleic acid exposure to radiation and chemical insults leads to damage and disease. Thus, detection and understanding DNA damage is important for elucidating molecular mechanisms of disease. However, current methods of DNA damage detection are either time-consuming, destroy the sample, or are too specific to be used for generic detection of damage. In this paper, we develop a fluorescence sensor of 2-aminopurine (2AP), a fluorescent analogue of adenine, incorporated in the loop of a hairpin probe for the quantification of ultraviolet (UV) C-induced nucleic acid damage. Our results show that the selectivity of the 2AP hairpin probe to UV-induced nucleic acid damage is comparable to molecular beacon (MB) probes of DNA damage. The calibration curve for the 2AP hairpin probe shows good linearity (R 2 =0.98) with a limit of detection of 17.2nM. This probe is a simple, fast and economic fluorescence sensor for the quantification of UV-induced damage in DNA.

Graphical Abstract

image

Graphical abstract Highlights

► Molecular beacon with 2AP bases detects DNA damage in a simple mix-and-read assay. ► Molecular beacons with 2AP bases detect damage at a 17.2nM limit of detection. ► The 2AP molecular beacon is linear over a 0–3.5μM concentration range for damage.

Improving the efficiency of ion mobility spectrometry analyses by using multivariate calibration

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
David Zamora, Marcelo Blanco
The simplicity, sensitivity and expeditiousness of ion mobility spectrometry (IMS) make it especially useful for the determination of active principal ingredients (APIs) present at low concentrations in pharmaceuticals. However, the poor resolution of this technique precludes the identification and/or determination of substances with similar molecular weights, which exhibit also similar drift times and give overlapped peaks as a result. Oral contraceptives are pharmaceutical formulations containing two APIs of similar molecular weights at very low concentrations which therefore give strongly overlapped peaks hindering their determination by IMS. In this work, we assessed the potential of IMS for detecting and quantifying the contraceptives ethinylestradiol (ETE) and desogestrel (DES) in commercial tablets. To this end, we used various chemometric techniques including a second-derivative (TN2D) algorithm and the more powerful choice Multivariate Curve Resolution (MCR) to improve the resolution of IMS and enable the determination of both APIs. Quantitation was based on PLS1 models for each API. The models constructed involve a single PLS factor with a Y-explained variance above 98.4%, obtaining a RMSEP of 0.34 and 0.63 for ETE and DES, respectively. The ensuing method, which was validated for use in routine analyses, is quite expeditious (analyses take less than 1min) and uses very small amounts of sample (a few microliters). Based on the results, IMS has a great potential for the qualitative and quantitative determination of APIs in low doses.

Graphical Abstract

image

Graphical abstract Highlights

► Simple, inexpensive and highly expeditious method for contraceptives determination. ► Chemometric techniques were assessed to improve efficiency in overlapped peaks. ► TN2D and MCR algorithms enable identification of the two analytes. ► PLS calibration allows APIs to be determined and overcomes their mutual interference.

Rapid prediction of moisture content of dehydrated prawns using online hyperspectral imaging system

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Di Wu, Hui Shi, Songjing Wang, Yong He, Yidan Bao, Kangsheng Liu
Because the shape of prawn is not round, spectroscopy instruments cannot measure the spectra of the whole prawn without containing background information. In this study, an online hyperspectral imaging system in the spectral region of 380–1100nm was developed to determine the moisture content of prawns at different dehydrated levels. Hyperspectral images of prawns were acquired at different dehydration periods. The spectra of prawns then were extracted from hyperspectral images based on ‘Manual Prawn Mask’ and ‘Automatic Prawn Mask’, respectively. Spectral data were analyzed using partial least squares regression (PLSR) and least-squares support vector machines (LS-SVM) to establish the calibration models, respectively. Successive projections algorithm (SPA) was first applied for the optimal wavelength selection in the hyperspectral image analysis. Out of 482 wavelengths, only twelve wavelengths (428, 445, 544, 569, 629, 672, 697, 760, 827, 917, 958, and 999nm) were selected by SPA as the optimum wavelengths for moisture prediction. Based on these optimum wavelengths, a multiple linear regression (MLR) calibration model was established and used to obtain the moisture distribution of each prawn. The overall results of this study revealed the potentiality of hyperspectral imaging as an objective and non-destructive method to obtain the content and distribution of moisture of prawns whose shapes are not round.

Graphical Abstract

image

Graphical abstract Highlights

► Hyperspectral imaging as moisture content predictors of prawn. ► Prawns were extracted from background using spatial features of hyperspectral imaging. ► Moisture contents were determined using spectral features of hyperspectral imaging. ► SPA was first used for wavelength selection in hyperspectral imaging analysis. ► Moisture content distributions were visualized at different dehydration periods.

3,4,9,10-Perylenetetracarboxylic dianhydride functionalized graphene sheet as labels for ultrasensitive electrochemiluminescent detection of thrombin

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Xianxue Gan, Ruo Yuan, Yaqin Chai, Yali Yuan, Yaling Cao, Yuhong Liao, Huijing Liu
A novel tracer, 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) functionalized graphene sheet (GS) composite (GS–TCDA), is employed to label the secondary anti-thrombin aptamer (TBA) to construct an ultrasensitive electrochemiluminescent sandwich-type aptasensor. The GS provided large surface area for loading abundant PTCDA and TBA with good stability and biocompatibility. Because of the excellent electroconductivity of GS and the desirable optical properties of PTCDA, the as-formed Apt II bioconjugate considerably amplified the electrochmiluminescence (ECL) signal of peroxydisulfate (S2O8 2−) and worked as the desirable label for Apt II. On the basis of the considerably amplified ECL signal and sandwich format, an extremely wide range from 1fM to 1nM with an ultralow detection limit of 0.33fM for thrombin was obtained. Additionally, the selectivity and stability of the proposed aptasensor were also excellent. Thus, this procedure has great promise for detection of thrombin present at ultra-trace levels during early stage of diseases.

Graphical Abstract

image

Graphical abstract Highlights

► We constructed a novel sandwich-type ECL aptasensor with 3,4,9,10-perylenetetracarboxylic dianhydride functionalized graphene sheet composite (GS–TCDA) for secondary anti-thrombin aptamer (TBA 2) labeling. ► The GS provided large surface area for loading abundant PTCDA and TBA 2 with good stability and biocompatibility. ► The as-formed GS–TCDA–TBA 2 bioconjugates were captured onto the electrode surface via “sandwich” reaction, obtaining a considerably enhanced ECL signal due to the synergistic amplification of PTCDA and GS on the ECL intensity of S2O8 2−. ► To the best of our knowledge, synergistic amplification of PTCDA and GS on the ECL signal of S2O8 2− was first reported here to develop a sensitive aptasensor.

An efficient strategy for unmodified nucleotide-mediated dispersion of magnetic nanoparticles, leading to a highly sensitive MRI-based mercury ion assay

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Guohai Liang, Peng Zhang, Huixiang Li, Zhengyong Zhang, Hui Chen, Song Zhang, Jilie Kong
It is highly attractive to develop a detection system that is not only sensitive and selective but also simple, rapid, practical and cost-effective in operation. Here, we report an interesting observation that single-stranded oligonucleotide (ssDNA) can adsorb efficiently on carboxylic acid-functionalized magnetic nanoparticles (CAMNPs) and stabilize the nanoparticles against aggregation in weakly acidic solution. The adsorbing rate closely correlates with the pH of the solution, the temperature and the sequence length of ssDNA. On the basis of this observation, we have designed a highly sensitive, non-sandwich type magnetic relaxation-based detection system for quantitatively probing mercury ion. The assay is independent of the sample's optical properties, requires no covalent modification of the ssDNA or the CAMNPs surfaces, and can be used for high-throughput analysis. By varying the concentration of CAMNPs, four orders of dynamic response range and a detection limit of 0.3nM for Hg2+ are achieved. Moreover, we developed a multi-sample assay to detect Hg2+ in real environmental samples with high sensitivity, selectivity and efficiency.

Graphical Abstract

image

Graphical abstract Highlights

► Single-stranded oligonucleotide (ssDNA) can adsorb efficiently on carboxylic acid-functionalized magnetic nanoparticles (CAMNPs). ► We use ssDNA to stabilize the CAMNPs against aggregation in weakly acidic solution. ► We develop a non-sandwich type magnetic relaxation-based detection system for quantitatively probing mercury ion (Hg2+). ► We use the MRI-based high-throughput screening method to detect Hg2+ in 40 samples at the same time.

Ultrasensitive detection of ovarian cancer marker using immunoliposomes and gold nanoelectrodes

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Subramanian Viswanathan, Chinnakkaruppanan Rani, Cristina Delerue-Matos
Mucin-16 (MUC16) is the established ovarian cancer marker used to follow the disease during or after treatment for epithelial ovarian cancer. The emerging science of cancer markers also demands for the new sensitive detection methods. In this work, we have developed an electrochemical immunosensor for antigen MUC16 using gold nanoelectrode ensemble (GNEE) and ferrocene carboxylic acid encapsulated liposomes tethered with monoclonal anti-Mucin-16 antibodies (αMUC16). GNEEs were fabricated by electroless deposition of the gold within the pores of polycarbonate track-etched membranes. Afterwards, αMUC16 were immobilized on preformed self-assembled monolayer of cysteamine on the GNEE via cross-linking with EDC-Sulfo-NHS. A sandwich immunoassay was performed on αMUC16 functionalized GNEE with MUC16 and immunoliposomes. The differential pulse voltammetry was employed to quantify the faradic redox response of ferrocene carboxylic acid released from immunoliposomes. The dose–response curve for MUC16 concentration was found between the range of 0.001–300UmL−1. The lowest detection limit was found to be 5×10−4 UmL−1 (S/N=3). We evaluated the performance of this developed immunosensor with commercial ELISA assay by comparing results obtained from spiked serum samples and real blood serum samples from volunteers.

Graphical Abstract

image

Graphical abstract Highlights

► PEGylated liposome biolabel was used for signal amplification. ► GNEE is an efficient support for antibody and electrochemical transduction. ► LOD was found 5×10−4 UmL−1 of MUC16 in blood serum. ► This MUC16 immunosensor is a better alternative to ELISA in clinical analysis.

Improvement of the homogeneity of protein-imprinted polymer films by orientated immobilization of the template

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Lijian Liu, Jingjing Zheng, Guijie Fang, Weihong Xie
A method for preparing homogeneous protein-imprinted polymer films with orientated immobilization of template is described. The template methyl parathion hydrolase (MPH) was modified with a peptide linker (Gly-Ser)5–Cys and was immobilized on a cover glass with a fixed orientation via the linker. The activity of the fusion enzyme (MPH-L) was evaluated by determining the product's absorbance at 405nm (A 405). Both the free and the immobilized MPH-L showed higher retention of the bioactivity than the wide type enzyme (MPH-W) as revealed by the A 405 values for MPH-Lfree/MPH-Wfree (1.159/1.111) and for MPH-Limmobilized/MPH-Wimmobilized (0.348/0.118). The immobilized MPH-L also formed a more homogeneous template stamp compared to the immobilized MPH-W. The molecularly imprinted polymer films prepared with the immobilized MPH-L exhibited high homogeneity with low Std. Deviations of 80 and 200 from the CL intensity mean volumes which were observed for batch-prepared films and an individual film, respectively. MPH-L-imprinted polymer film also had a larger template binding capacity indicated by higher CL intensity mean volume of 3900 INT over 2500 INT for MPH-W-imprinted films. The imprinted film prepared with the orientated immobilization of template showed an imprinting factor of 1.7, while the controls did not show an imprinting effect.

Graphical Abstract

image

Graphical abstract Highlights

► MPH was genetically modified at its C-terminal with (Gly-Ser)5–Cys. ► MPH-L was immobilized with fixed orientation via disulfide chemistry. ► The immobilized MPH-L retained the activity of MPH. ► MPH-L formed a homogeneous template. ► Homogeneous MIP film was obtained with orientated immobilization of the template.

Influence of hole mobility on the response characteristics of p-type nickel oxide thin film based glucose biosensor

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Manisha Tyagi, Monika Tomar, Vinay Gupta
RF sputtered p-type nickel oxide (NiO) thin film exhibiting tunable semiconductor character which in turns enhanced its functional properties. NiO thin film with high hole mobility is developed as a potential matrix for the realization of glucose biosensor. NiO thin film prepared under the optimized deposition conditions offer good electrical conductivity (1.5×10−3 Ω−1-cm−1) with high hole mobility (2.8cm2 V−1 s−1). The bioelectrode (GO x /NiO/ITO/glass) exhibits a low value of Michaelis–Menten constant (K m =1.05mM), indicating high affinity of the immobilized GO x toward the analyte (glucose). Due to the high surface coverage (2.32×10−7 molcm−2) of the immobilized enzyme on to the NiO matrix and its high electrocatalytic activity, the prepared biosensor exhibits a high sensitivity of 0.1mA(mM−1-cm−2) and a good linearity from 25 to 300mgdL−1 of glucose concentration with fast response time of 5s. Various functional properties of the material (mobility, crystallinity and stress) are found to influence the charge communication feature of NiO thin film matrix to a great extent, resulting in enhanced sensing response characteristics.

Graphical Abstract

image

Graphical abstract Highlights

► Manuscript emphasizes that p-type semiconducting matrix is attractive for biosensor with enhanced response. ► Hole mobility and stress in the matrix play major role in governing the sensing response characteristics. ► p-type NiO films act as efficient matrix with high sensitivity for realization of integrated biochip.

Carbon nanoparticles from corn stalk soot and its novel application as stationary phase of hydrophilic interaction chromatography and per aqueous liquid chromatography

25 April 2012, 10:43:57
Publication year: 2012
Source:Analytica Chimica Acta, Volume 726
Yuanyuan Li, Luan Xu, Tong Chen, Xiaoyan Liu, Zhigang Xu, Haixia Zhang
Carbon nanoparticles (CNPs) (6–18nm in size) were prepared by refluxing corn stalk soot in nitric acid. The obtained acid-oxidized CNPs are soluble in water due to the existence of carboxylic and hydroxyl groups. 13C NMR measurement shows the CNPs are mainly of sp2 and sp3 carbon structure different from CNPs obtained from candle soot and natural gas soot. Furthermore, these CNPs exhibit unique photoluminescence properties. Interestingly, the CNPs might be exploited to immobilize on the surface of porous silica particles as chromatographic stationary phase. The resultant packing material was evaluated by high-performance liquid chromatography, indicating that the new stationary phase could be used in hydrophilic interaction liquid chromatography (HILIC) and per aqueous liquid chromatography (PALC) modes. The separation of five nucleosides, four sulfa compounds and safflower injection was achieved by using the new column in the HILIC and PALC modes, respectively.

Graphical Abstract

image

Graphical abstract Highlights

► Carbon nanoparticles (6–18nm in size) were prepared from corn stalk soot. ► CNPs-based silica were used as novel chromatography stationary phase. ► The new phase shows good separation selectivity for polar compounds. ► The new phase had the similar retention for polar probes in HILIC and PALC modes. ► In contrast to PALC, under HILIC conditions high efficiencies were achieved.

New 2012 Mystaire® Misonix® full-line Laboratory Safety Equipment catalogs are now available


Mystaire Misonix is pleased to announce the release of the first complete catalog since the acquisition in October 2011. Mystaire Misonix has manufactured ductless laboratory safety products for more than 50 years. The new 2012 catalog includes ductless hoods, workstations and enclosures. This updated catalog contains photos, specs and overviews on a full range of products to protect the operator or process.

Featured is the Aura® ductless fume hood with the state-of-the-art EverSafe II™ microprocessor controller. New to Mystaire Misonix is a full line of PCR workstations, including the MY-PCR Prep Station and CleanPrep™ dead air box.  

Mystaire Misonix products are engineered and manufactured in the United States. Product range includes ductless fume hoods, PCR workstations, clean benches, balance enclosures, fume extractors, room air purifiers and more.

Copies of the Mystaire Misonix 2012 Catalog can be requested here:

Bruker Post Three New SCION GC-MS Application Notes for Download


Bruker Chemical & Applied Markets division (CAM), US: A series of three new Application Notes describing multi-residue analysis in complex food matrix samples and environmental monitoring using the Bruker SCION™ tandem mass spectrometry (MS) coupled to gas chromatography (GC-MS/MS) are now available on Bruker’s dedicated SCION product website www.scionhasarrived.com. GC-MS/MS operating in multiple reaction monitoring (MRM) mode is rapidly becoming the method of choice for targeted screening due to its high specificity and capability of simultaneously monitoring of numerous product ions for a large number of compounds in complex sample matrices, such as food and environmental samples. Bruker’s SCION triple-quadrupole (TQ) MS for GC detection enhances data quality and productivity for analysts working in routine testing and applied markets; these systems combine performance and ease of use like never before.
This series of three Application Notes explore some of the innovative design features of Bruker’s SCION SQ and TQ, highlighting the benefits of these features with data. The Application Notes include:
Lenses or No Lenses? A Study of Ion Transfer Efficiency at Interfaces in a Lens-free Triple Quadrupole MS (authored by Felician Muntean and Roy Moeller, Bruker Chemical and Applied Markets Division). This Application Brief explores the industries first lens-free GC-MS - the Bruker SCION TQ. The radio-frequency only (RF-only) interface is not just simpler to tune and more robust than a lens-based interface, but it also provides significantly higher ion transfer efficiency, with greater overall sensitivity. http://globalfoodtesting.com/fileadmin/media/kbase/methods/AppNote_Lenses.pdf
A Compound-based Approach to Simplify GC-MS/MS Method Development and Data Processing for Multi-Residue Analysis by GC-MS/MS of 49 Pesticides in Pumpkin Extracts (authored by Qingyu (Helen) Sun and Kefei Wang, Bruker Chemical and Applied Markets Division). In this Application Brief Bruker’s compound based scanning (CBS) software is described. This software greatly simplifies method development for multi-residue analysis on SCION TQ MS, which improves productivity. The results generated on the SCION TQ demonstrate good sensitivity, excellent reproducibility and robustness in a complex vegetable matrix. http://globalfoodtesting.com/fileadmin/media/kbase/methods/AppNote_Pumpkin_Extract.pdf
Screening for Pyrethroid Insecticides in Sediment Samples by GC-MS/MS (authored by Ed George, Bruker Chemical and Applied Markets Division, in conjunction with the California Department of Food and Agriculture). A simple screening method for pyrethroid insecticides in sediment samples is described in this Application Note. Electron impact ionization (EI) with tandem MS/MS in combination with programmed temperature vaporization injection (PTV) were used in order to obtain excellent specificity and low limits of detection of pyrethroids in river and lake sediments. http://globalfoodtesting.com/fileadmin/media/kbase/methods/CA_pyrethroid_ebook.pdf
To view the Application Notes visit  http://www.scionhasarrived.com

Tuesday, 24 April 2012

Just Published: Analytica Chimica Acta


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Sample introduction techniques for microchip electrophoresis: A review

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
James M. Karlinsey
The number of applications of microfluidic analysis systems continues to increase, along with the variety of substrate materials and complexity of the devices themselves. One of the most common features of these devices that has remained relatively unchanged, however, is the introduction of a sample mixture into a separation channel so that individual components can be separated by electrophoresis. Whether a relatively simple mixture of amino acids or a more complex sample of DNA fragments extracted and amplified on-chip, the ability to reliably and reproducibly inject a representative sample is arguably the most significant requirement for an electrophoretic micro total analysis system (μTAS). This review will focus on the different methods reported for sample introduction in microchip electrophoresis, highlighting both pressure-driven and electrokinetic techniques, with an emphasis on the methods employed in μTAS applications.

Graphical Abstract

image

Graphical abstract Highlights

► Pressure injections for microchip electrophoresis are reviewed for the first time. ► Electrokinetic and pressure injections are both presented for comparison. ► Injections for capillary electrophoresis are presented for context.

A density-based segmentation for 3D images, an application for X-ray micro-tomography

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Thanh N. Tran, Thanh T. Nguyen, Tofan A. Willemsz, Gijs van Kessel, Henderik W. Frijlink, Kees van der Voort Maarschalk
Density-based spatial clustering of applications with noise (DBSCAN) is an unsupervised classification algorithm which has been widely used in many areas with its simplicity and its ability to deal with hidden clusters of different sizes and shapes and with noise. However, the computational issue of the distance table and the non-stability in detecting the boundaries of adjacent clusters limit the application of the original algorithm to large datasets such as images. In this paper, the DBSCAN algorithm was revised and improved for image clustering and segmentation. The proposed clustering algorithm presents two major advantages over the original one. Firstly, the revised DBSCAN algorithm made it applicable for large 3D image dataset (often with millions of pixels) by using the coordinate system of the image data. Secondly, the revised algorithm solved the non-stability issue of boundary detection in the original DBSCAN. For broader applications, the image dataset can be ordinary 3D images or in general, it can also be a classification result of other type of image data e.g. a multivariate image.

Graphical Abstract

image

Graphical abstract Highlights

► We revised the DBSCAN algorithm for segmentation and clustering of large 3D image dataset and classified multivariate image. ► The algorithm takes into account the coordinate system of the image data to improve the computational performance. ► The algorithm solved the instability problem in boundaries detection of the original DBSCAN. ► The segmentation results were successfully validated with synthetic 3D image and 3D XMT image of a pharmaceutical powder.

Evolving chemometric models for predicting dynamic process parameters in viscose production

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Carlos Cernuda, Edwin Lughofer, Lisbeth Suppan, Thomas Röder, Roman Schmuck, Peter Hintenaus, Wolfgang Märzinger, Jürgen Kasberger
In viscose production, it is important to monitor three process parameters in order to assure a high quality of the final product: the concentrations of H2SO4, Na2SO4 and Z n SO4. During on-line production these process parameters usually show a quite high dynamics depending on the fiber type that is produced. Thus, conventional chemometric models, which are trained based on collected calibration spectra from Fourier transform near infrared (FT-NIR) measurements and kept fixed during the whole life-time of the on-line process, show a quite imprecise and unreliable behavior when predicting the concentrations of new on-line data. In this paper, we are demonstrating evolving chemometric models which are able to adapt automatically to varying process dynamics by updating their inner structures and parameters in a single-pass incremental manner. These models exploit the Takagi–Sugeno fuzzy model architecture, being able to model flexibly different degrees of non-linearities implicitly contained in the mapping between near infrared spectra (NIR) and reference values. Updating the inner structures is achieved by moving the position of already existing local regions and by evolving (increasing non-linearity) or merging (decreasing non-linearity) new local linear predictors on demand, which are guided by distance-based and similarity criteria. Gradual forgetting mechanisms may be integrated in order to out-date older learned relations and to account for more flexibility of the models. The results show that our approach is able to overcome the huge prediction errors produced by various state-of-the-art chemometric models. It achieves a high correlation between observed and predicted target values in the range of [0.95,0.98] over a 3 months period while keeping the relative error below the reference error value of 3%. In contrast, the off-line techniques achieved correlations below 0.5, ten times higher error rates and the more deteriorate, the more time passes by.

Graphical Abstract

image

Graphical abstract Highlights

► Quality assurance of process parameters in viscose production. ► Automatic prediction of spin-bath concentrations based on FTNIR spectra. ► Evolving chemometric models for efficiently handling changing system dynamics over time (no time-intensive re-calibration needed). ► Significant reduction of huge errors produced by statistical state-of-the-art calibration methods. ► Sufficient flexibility achieved by gradual forgetting mechanisms.

Ultrasensitive aptamer-based bio bar code immunomagnetic separation and electrochemiluminescence method for the detection of protein

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Debin Zhu, Xiaoming Zhou, Da Xing
An ultrasensitive aptamer-based bio bar code immunomagnetic separation and electrochemiluminescence (IM-ECL) method for the detection of protein is developed. The target protein is captured by biotin-labeled aptamer (biotin probe) and [Ru(bpy)3]2+ (TBR)-Au bio bar code-labeled aptamer (ECL nanoprobe), to form a double aptamer–protein sandwich complex. The complex is then immobilized on the streptavidin microbeads through biotin–streptavidin linkage and detected by ECL assay. The ECL signal of the target protein is amplified by the TBR-bio bar code DNAs. As an example, platelet-derived growth factor B-chain homodimer (PDGF-BB) was detected by the method. Experimental results show that the detection limit of the assay is 1pM of PDGF-BB. A calibration curve with a linearity range from 1pM to 10nM is established, thus, make quantitative analysis possible. The method has been used to detect PDGF-BB in fetal calf serum with minimum background interference. Due to the wide availability of aptamer for numerous proteins, this aptamer-based bio bar code IM-ECL method holds great promise in protein detection.

Graphical Abstract

image

Graphical abstract Highlights

► The ECL nanoprobe was synthesized by bifunctioning AuNPs with the capture aptamer and the TBR-bio bar code DNAs with a ratio of 1:100. ► The ECL nanoprobe and the biotin-labeled aptamer were incubated with the target protein to form a double aptamer–protein sandwich complex. ► The sandwich complex was captured by the streptavidin microbeads through biotin–streptavidin linkage and detected by ECL assay.

Separation and electrochemical detection of paracetamol and 4-aminophenol in a paper-based microfluidic device

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Leandro Yoshio Shiroma, Murilo Santhiago, Angelo L. Gobbi, Lauro T. Kubota
The present work describes the construction and application of a simple, low cost and sensitive microfluidic paper-based device with electrochemical detection for the detection of paracetamol and 4-aminophenol. The separation channels of a width of 2.0mm were created on paper using a wax printing process to define the regions of the device. A baseline separation level of the analytes can be obtained in 0.1molL−1 acetate buffer solution at pH 4.5 and by injecting 500nL of the standard solutions at 12mm from the working electrode. The electrochemical detection system was created at the end of the channels through a process known as sputtering. The previously separated analytes were detected at the end of the hydrophilic separation channel by applying a potential of 400mV vs. pseudo Au on the working electrode. Experimental variables such as type of paper (cation exchanger and n1), pH, sample volume, applied potential and distance of sample injection were evaluated and, under the conditions of higher response, it was possible to obtain detection limits of 25.0 and 10.0μmolL−1 for paracetamol and 4-aminophenol, respectively.

Graphical Abstract

image

Graphical abstract Highlights

► Low cost and simple paper-based microfluidic device with electrochemical detection. ► Only two steps are necessary for the construction of the device, construction of the hydrophobic walls and gold sputtering. ► The substrate works as a separation platform and makes the separation of paracetamol and 4-aminophenol. ► Paper works as a filter and no sample pre treatment is necessary to perform the analysis. ► Baseline separation of the analytes can be achieved by injecting the sample at 12mm from the working electrode.

Electromembrane extraction combined with gas chromatography for quantification of tricyclic antidepressants in human body fluids

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Saied Saeed Hosseiny Davarani, Amin Morteza Najarian, Saeed Nojavan, Mohammad-Ali Tabatabaei
Recent advances in electromembrane extraction (EME) methodology calls for effective and accessible detection methods. Using imipramine and clomipramine as model therapeutics, this proof-of-principle work combines EME with gas chromatography analysis employing a flame ionization detector (FID). The drugs were extracted from acidic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 2-nitrophenyl octyl ether (NPOE) impregnated on the walls of the hollow fiber. EME parameters, such as SLM composition, type of ion carrier, pH and the composition of donor and acceptor solutions, agitation speed, extraction voltage, and extraction time were studied in detail. Under optimized conditions, the therapeutics were effectively extracted from different matrices with recoveries ranging from 90 to 95%. The samples were preconcentrated 270–280 times prior to GC analysis. Reliable linearity was also achieved for calibration curves with a regression coefficient of at least 0.995. Detection limits and intra-day precision (n =3) were less than 0.7ngmL−1 and 8.5%, respectively. Finally, method was applied to determination and quantification of drugs in human plasma and urine samples and satisfactory results were achieved.

Graphical Abstract

image

Graphical abstract Highlights

In this study electromembrane extraction (EME) procedure was combined with GC-FID for quantification of tricyclic antidepressants (TCADs) in human body fluids. ► Electromembrane extraction of tricyclic anti-depressants (TCADs). ► Combine EME with GC-FID detection. ► Direct water injection to GC capillary column. ► Extraction of TCADs from human body fluids. ► Enrichment factor higher than 215 with 2mL sample solution.

Quantification of retinoid concentrations in human serum and brain tumor tissues

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Ramadan Ali, Benito Campos, Gerhard Dyckhoff, Walter E. Haefeli, Christel Herold-Mende, Jürgen Burhenne
Retinoic acid signaling is essential for central nervous system (CNS) differentiation and appears to be impaired in tumors. Thus far, there are no established methods to quantify relevant retinoids (all-trans-retinoic acid, 9-cis-retinoic acid, 13-cis retinoic acid, and retinol) in human brain tumors. We developed a single step extraction and quantification procedure for polar and apolar retinoids in normal tissue, lipid-rich brain tumor tissues, and serum. This quantification procedure is based on high performance liquid chromatography (HPLC) with diode-array detection (DAD) using all-trans-acitretin as an internal standard and extraction by liquid–liquid partition with ethyl acetate and borate buffer at pH 9. Recovery with this extraction procedure was higher than earlier (two-step) liquid–liquid extraction procedures based on hexane, NaOH, and HCl. The overall quantification procedure was validated according to Food and Drug Administration (FDA) guidelines and fulfilled all criteria of accuracy, precision, selectivity, recovery, and stability. The overall method accuracy varied between −5.6% and +5.4% for serum and −3.8% and +6.2% for tissues, and overall precision ranged from 3.1% to 6.9% for serum and 2.1% to 8.3% for tissues (%CV batch-to-batch). The lower limit of quantification for all compounds in tumor tissue (and serum) was 3.9ngg−1 (ngmL−1). Using this assay, photodegradation of the retinoids was evaluated and endogenous polar and apolar retinoids were quantified in sera and brain tumor tissues of patients and compared with serum and tonsil tissue concentrations of controls. It may thus serve as a suitable method for the characterization of retinoid uptake and metabolism in the respective compartments.

Graphical Abstract

image

Graphical abstract Highlights

► It is the first sensitive assay for the quantification of retinoids in lipid-rich tissue (brain). ► We report the relationship between gender and age for retinoids other than retinol. ► This is the first report assessing the light sensitivity of different retinoids in biological matrix. ► This is the first report analyzing serum:tissue ratios of retinoid concentrations in normal tissue (tonsils). ► We report the relationship of retinoid serum:tissue ratios in tumors and confirm substantial accumulation in tissue.

Fluorescence-quenching-based homogeneous caspase-3 activity assay using photon upconversion

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Johanna Vuojola, Terhi Riuttamäki, Essi Kulta, Riikka Arppe, Tero Soukka
Caspase proteases are key mediators in apoptosis and thus of great interest in pharmaceutical industry. Enzyme-activity assays are commonly employed in the screening of protease inhibitors that are potential drug candidates. Conventional homogeneous fluorescence-based assays are susceptible to autofluorescence originating from biological material. This background autofluorescence can be eliminated by using upconverting phosphors (UCPs) that emit visible light upon excitation at near-infrared. In the assay energy was transferred from a UCP-donor to a conventional fluorophore acceptor that resided at one end of a caspase-3-specific substrate peptide. Attached to the other end was a quencher molecule that was used to attenuate the acceptor emission through intramolecular energy transfer in an intact peptide. In non-inhibitory conditions the enzyme reaction separated the fluorophore from the quencher and the emission of the fluorophore was recovered. The method was applied for the detection and characterization of a known caspase-3 inhibitor Z-DEVD-FMK, and the assay gave IC50 values of approximately 13nM for this inhibitor. We have demonstrated the applicability of UCPs on a fluorescence-quenching-based homogeneous enzyme-activity assay for the detection of caspase-3 inhibitors. The use of near-infrared excitable UCPs enables inexpensive instrumentation and total elimination of autofluorescence, while the use of an internally quenched substrate molecule diminishes the background resulting from radiatively excited acceptor molecules. The reduction of autofluorescence and radiative background result in high signal-to-background ratios (ratios of approximately 100 were obtained). By further utilizing assay miniaturization and signal enhancement in a white microtitration plate, a significant reduction in the reagent consumption can be achieved rendering the assay applicable for high-throughput screening.

Graphical Abstract

image

Graphical abstract Highlights

► We demonstrate the use of photon upconversion in a caspase-3 activity assay. ► The separation-free assay uses an internally quenched substrate peptide. ► UCPs enable simple instrumentation and total elimination of autofluorescence. ► A sensitive assay with high signal-to-background ratios was achieved. ► Suitable for high-throughput screening through miniaturization and white plates.

Development of an electrochemical membrane-based nanobiosensor for ultrasensitive detection of dengue virus

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Ming Soon Cheng, Jia Shin Ho, Cheong Huat Tan, Jeslyn Pei Sze Wong, Lee Ching Ng, Chee-Seng Toh
A sensitive membrane-based electrochemical nanobiosensor is developed for the detection of dengue type 2 virus (DENV-2) using nanoporous alumina-modified platinum electrode. Its sensing mechanism relies on the monitoring of electrode's Faradaic current response toward redox probe, ferrocenemethanol, which is sensitive toward the formation of immune complexes within the alumina nanochannels. Anti-DENV-2 monoclonal antibody (clone 3H5, isotype IgG) is used as the biorecognition element in this work. The stepwise additions of antibody, bovine serum albumin (BSA) and DENV-2 are characterized by differential pulse voltammetry (DPV). A low detection limit of 1pfumL−1 with linear range from 1 to 103 pfumL−1 (R 2 =0.98) can be achieved by the nanobiosensor. The nanobiosensor is selective toward DENV-2 with insignificant cross reaction with non-specific viruses, Chikungunya virus, West Nile virus and dengue type 3 virus (DENV-3). Relative standard deviation (RSD) for triplicate analysis of 5.9% indicates an acceptable level of reproducibility. The first direct quantitation of DENV-2 concentration in whole mosquito vector is demonstrated using this electrochemical nanobiosensor.

Graphical Abstract

image

Graphical abstract Highlights

► Label-free nanobiosensor using virus capture method. ► Direct virus particles detection with specific virus identification. ► Detection range of virus from 1 to 1000pfumL−1 with less than 1h analysis time.

Modified mesoporous silica materials for on-line separation and preconcentration of hexavalent chromium using a microcolumn coupled with flame atomic absorption spectrometry

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Zheng Wang, Dong-Mei Fang, Qing Li, Ling-Xia Zhang, Rong Qian, Yan Zhu, Hai-Yun Qu, Yi-Ping Du
A modified SBA-15 mesoporous silica material NH2-SBA-15 was synthesized successfully by grafting γ-aminopropyl-triethoxysilane. The material was characterized using transmission electron microscopy (TEM) and Fourier transform infrared/Raman (FT-IR/Raman) spectroscopy, and used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Effective sorption of Cr (VI) was achieved at pH 2.0 with no interference from Cr (III) and other ions and 0.5molL−1 NH3·H2O solution was found optimal for the complete elution of Cr (VI). An enrichment factor of 44 and was achieved under optimized experimental conditions at a sample loading of 2.0mLmin−1 sample loading (300s) and an elution flow rate of 2.0mLmin−1 (24s). The precision of the 11 replicate Cr (VI) measurements was 2.1% at the 100μgL−1 level with a detection limit of 0.2μgL−1 (3s, n =10) using the FAAS. The developed method was successfully applied to trace chromium determination in waste water. The accuracy was validated using a certified reference material of riverine water (GBW08607).

Graphical Abstract

image

Graphical abstract Highlights

► A modified SBA-15 mesoporous silica material (NH2-SBA-15) was synthesized as sorbent. ► The material was used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). ► The NH2-SBA-15 enables retain Cr (VI) with an enrichment factor of 44. ► The micro-column of NH2-SBA-15 underwent more than 100 adsorption/desorption cycles.

Effect of temperature and solvent composition on acid dissociation equilibria, I: Sequenced pssKa determination of compounds commonly used as buffers in high performance liquid chromatography coupled to mass spectroscopy detection

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 725
Juan M. Padró, Agustín Acquaviva, Marcos Tascon, Leonardo G. Gagliardi, Cecilia B. Castells
A new automated and rapid potentiometric method for determining the effect of organic-solvent composition on pK a has been developed. It is based on the measurements of pH values of buffer solutions of variable solvent compositions using a combined glass electrode. Additions of small volumes of one precisely thermostated solution into another, both containing exactly the same analytical concentrations of the buffer components, can produce continuous changes in the solvent composition. Two sequences of potential measurements, one of increasing and the other of decreasing solvent content, are sufficient to obtain the pK a values of the acidic compound within the complete solvent-composition range in about 2h. The experimental design, procedures, and calculations needed to convert the measured pH into the thermodynamic pK a values are thoroughly discussed. This rapid and automated method allows the systematic study of the effect of solvent compositions and temperatures on the pK a. It has been applied to study the dissociation constants of two monoprotic acids: formic acid and triethylamine:HCl in acetonitrile/water mixtures within the range from 0 to 90% (v/v) at temperatures between 20°C and 60°C. These volatile compounds are frequently used to control the pH of the mobile phase in HPLC, especially in methods coupled to mass-spectrometry detection. The obtained pK a values are in excellent agreement with those previously reported. The results were fitted to empirical functions between pK a and temperature and composition. These equations, which can be used to estimate the pK a of these substances at any composition and temperature, would be highly useful in practical work during chromatographic method development.

Graphical Abstract

image

Graphical abstract Highlights

► We developed a rapid potentiometric method for sequential pK a determinations. ► We measured pK a of buffers from 0 to 90% (v/v) acetonitrile/water and from 20 to 60°C. ► Sequences of 42 pK a-data spanned over a wide solvent composition range needed 2h. ► We measured pK a of formic acid and triethylamine/HCl in up to 90% (v/v) acetonitrile. ► The high-throughput method was applied to obtain pK a of two common buffers in LC/MS.
24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 724
Juan M. Bosque-Sendra, Luis Cuadros-Rodríguez, Cristina Ruiz-Samblás, A. Paulina de la Mata
The characterization and authentication of fats and oils is a subject of great importance for market and health aspects. Identification and quantification of triacylglycerols in fats and oils can be excellent tools for detecting changes in their composition due to the mixtures of these products. Most of the triacylglycerol species present in either fats or oils could be analyzed and identified by chromatographic methods. However, the natural variability of these samples and the possible presence of adulterants require the application of chemometric pattern recognition methods to facilitate the interpretation of the obtained data. In view of the growing interest in this topic, this paper reviews the literature of the application of exploratory and unsupervised/supervised chemometric methods on chromatographic data, using triacylglycerol composition for the characterization and authentication of several foodstuffs such as olive oil, vegetable oils, animal fats, fish oils, milk and dairy products, cocoa and coffee.

Graphical Abstract

image

Graphical abstract Highlights

► Relationships between chemometric and chromatography. ► Use of triglyceride profiles and triglyceride chromatographic fingerprints for the characterization of fat and oils. ► Chemometric tools applied to authenticate fat and oils.

Locally linear embedding method for dimensionality reduction of tissue sections of endometrial carcinoma by near infrared spectroscopy

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 724
Na Qi, Zhuoyong Zhang, Yuhong Xiang, Peter de B. Harrington
Locally linear embedding (LLE) is introduced here as a nonlinear compression method for near infrared reflectance spectra of endometrial tissue sections. The LLE has been evaluated by using support vector machine (SVM) classifiers and the projected difference resolution (PDR) method. Synthetic data sets devised to resemble near-infrared spectra of tissue samples were used to characterize the performance of the LLE. The LLE was compared using principal component compression (PCC) method to evaluate nonlinear and linear compression. For a set of real tissue samples, if the compressed data were not range-scaled prior to SVM classification, the principal component compressed data gave an average prediction rate of 39±2% while the LLE 94±2%; if range-scaled after compression, the LLE and PCC performed evenly, with maximum average prediction values of 94±2% and 93±2%, respectively. The SVM without compression yielded a classification rate of 92±2%. The prediction accuracy was consistent with PDR results. Without the second derivative preprocessing, the classification rates were 90±3%, 89±2%, and 78±2% for the LLE compressed, the PCC, and no compression classifications by the SVM, respectively.

Graphical Abstract

image

Graphical abstract Highlights

► Locally linear embedding (LLE) is introduced first time to the field of spectroscopy as a dimensionality reduction method for feature extraction of near infrared spectra from reflectance measurements of endometrial tissue sections. ► LLE was evaluated and compared with principal component compression (PCC) by using support vector machine (SVM) classifiers. ► The projected difference resolution (PDR) method was used to evaluate the LLE method. ► Some exemplary synthetic data sets were created and NIR spectral data of real tissue samples were collected to verify LLE coupled to SVM for classification. ► LLE combined with the SVM gave better predictions and can effectively extract more discriminating features compared to PCC without scaling.

Estimation of measurement uncertainty of pesticides, polychlorinated biphenyls and polyaromatic hydrocarbons in sediments by using gas chromatography–mass spectrometry

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 724
Óscar Pindado Jiménez, Rosa Mª Pérez Pastor
The evaluation of the uncertainty associated to analytical methods is essential in order to demonstrate quality of a result. However, there is often lack of information about uncertainty of methods to estimate persistent organic pollutants concentration in complex matrix. Current work has thoroughly evaluated uncertainty associated to quantification of several organochloride pesticides, PCBs and PAHs in sediments. A discussion of the main contributions to the overall uncertainty is reported, allowing authors to establish the accuracy of results and plan future improvements. Combined uncertainties ranged between 5–9% (pesticides), 4–7% (PCBs) and 5–10% (PAHs), being uncertainty derived of calibration the main contribution. Also, the analytical procedure was validated analysing a standard reference material (IAEA-408).

Graphical Abstract

image

Graphical abstract Highlights

► We report an evaluation of uncertainty associated to analysis of POPs in sediments. ► We give useful and easy to follow guidance to calculate uncertainty. ► Evaluation of uncertainty is essential in environmental analysis. ► Uncertainty derived of calibration is the main contribution. ► We present strategies for diminish uncertainty.

Recognition of chemical compounds in contaminated water using time-dependent multiple dose cellular responses

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 724
T.H. Pan, B. Huang, J.Z. Xing, W.P. Zhang, S. Gabos, J. Chen
An early determination of toxicant compounds of water contaminations can gain critical time to protect citizens’ health and save substantial amounts of medical costs. To determine toxins in real time, a multi-dose classification algorithm using cellular state variable identification (CSVID) is developed in this paper. First, the dynamic cytotoxicity response profiles of living cells are measured using a real-time cell electronic sensing (RT-CES) system. Changes in cell number expressed as cell index (CI) are recorded on-line as time series. Then CSVID, which reflects the cell killing, cell lysis and certain cellular pathological changes, is extracted from those dynamic cellular responses. Finally, a support vector machine (SVM) algorithm based on CSVID is employed to classify chemical compounds and determine their analogous cellular response pathway. In order to increase the classification accuracy, a majority vote of the class labels is also proposed. Several validation studies demonstrate that CSVID-based classification algorithm has great potential in distinguishing the cytotoxicity response of the cells in the presence of toxins.

Graphical Abstract

image

Graphical abstract Highlights

► Dose- and time-dependent cellular responses are used to evaluate the cytotoxicity. ► The CI can reflect the cell number, cell viability, morphological change, etc. ► The CSVID can capture the dynamic information after cells exposed to toxins. ► The multi-class classification can distinguish the compounds using multi-doses. ► The majority vote strategy (fingerprint) can improve the classification accuracy.

Study on the application of reduced graphene oxide and multiwall carbon nanotubes hybrid materials for simultaneous determination of catechol, hydroquinone, p-cresol and nitrite

24 April 2012, 09:30:42
Publication year: 2012
Source:Analytica Chimica Acta, Volume 724
Fangxin Hu, Shihong Chen, Chengyan Wang, Ruo Yuan, Dehua Yuan, Cun Wang
In this paper, the reduced graphene oxide and multiwall carbon nanotubes hybrid materials (RGO–MWNTs) were prepared and a strategy for detecting environmental contaminations was proposed on the basis of RGO–MWNTs modified electrode. The hybrid materials were characterized by the scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and N2 sorption–desorption isotherms. Due to the excellent catalytic activity, enhanced electrical conductivity and high surface area of the RGO–MWNTs, the simultaneous measurement of hydroquinone (HQ), catechol (CC), p-cresol (PC) and nitrite (NO2 −) with four well-separate peaks was achieved at the RGO–MWNTs modified electrode. The linear response ranges for HQ, CC, PC and NO2 − were 8.0–391.0μM, 5.5–540.0μM, 5.0–430.0μM and 75.0–6060.0μM, correspondingly, and the detection limits (S/N=3) were 2.6μM, 1.8μM, 1.6μM and 25.0μM, respectively. The outstanding film forming ability of RGO–MWNTs hybrid materials endowed the modified electrode enhanced stability. Furthermore, the fabricated sensor was applied for the simultaneous determination of HQ, CC, PC and NO2 − in the river water sample.

Graphical Abstract

image

Graphical abstract Highlights

In this paper, the reduced graphene oxide and multiwall carbon nanotubes hybrid materials (RGO–MWNTs) were prepared and a novel strategy for the simultaneous determination of multiple environmental contaminations has been proposed on the basis of RGO–MWNTs hybrid materials modified electrode. The hybrid materials were characterized by the scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and N2 sorption–desorption isotherms. Due to the excellent catalytic activity, enhanced electrical conductivity, high surface area and porous structure of the RGO–MWNTs, the RGO–MWNTs/GCE achieved the simultaneous measurement of hydroquinone (HQ), catechol (CC), p-cresol (PC) and nitrite (NO2 −) with well-separate four peaks. Scheme 1a illuminated the preparation process of the RGO–MWNTs hybrid materials. Scheme 1b explains the electron mediating properties of RGO–MWNTs/GCE towards the oxidation of HQ, CC, PC and NO2 −. Scheme 1c presented the SEM image of RGO–MWNTs hybrid materials. Scheme 1d and e showed the 2D and 3D AFM images of RGO–MWNTs films, respectively. ► The novel RGO–MWNTs hybrid materials were synthesized. ► The simultaneous detection of four environmental contaminations was achieved. ► SEM, AFM, XPS was employed to characterize the RGO–MWNTs hybrid materials.