This blog has been set up for editors, reviewers, authors and readers of Elsevier's Analytical Chemistry Journals - all of which can be seen below. It will be updated from Monday to Friday with general news and announcements concerning the titles listed on this page. It should be noted that the views or claims made in the news items and feeds are not necessarily those of the Publisher.
FOSS NIRSystems, Inc. has introduced Vision 3.60. Vision is a
software package specifically designed for use with the FOSS NIRSystems
Near-Infrared (NIR) laboratory and process analyzers. Vision 3.60replaces earlier versions of Vision and offers support for
the latest NIR laboratory and process hardware.
The main new features in Vision 3.60:
Vision 3.60 is 64 bit
compatible. Vision can now be installed and run on both 32 bit and 64 bit
versions of Windows XP, Windows Vista, and Windows 7.
Vision
3.60 supports the NIRS DS2500 Analyzer
If you are a current user of the FOSS Vision software, please contact us for more information and/or a
complete list of new features appearing in version 3.60.
The FOSS Vision software is 21 CFR Part 11 compliant and supports PAT through numerous process analysis
options and process communication capabilities. The software has an extensive
security system with multiple access levels, secure data archiving
and report generation as well as database and spreadsheet
compatibility. Vision comes with a user-friendly electronic manual
with tutorials and data for self taught hands-on method development and software
operation.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Liang Wu, Yan Yang,
Hejing Zhang, Gangbing Zhu, Xiaohua Zhang, Jinhua Chen By using biobarcode
nanoparticles, we have successfully constructed a DNA-based biosensor for
amplified electrochemical detection of hydroxyl radical (OH). Thiolated DNA1
(SH-DNA1) was firstly immobilized on the planar gold (Au) electrode. OH
generated from Fenton reaction could induce serious oxidative damage of the DNA
layer adsorbed on the electrode surface, which was monitored by an intercalating
probe, methylene blue (MB). In order to enhance the sensitivity of the
biosensor, DNA2-functionalized Au nanoparticles (DNA2-AuNPs) were used to
amplify the response signal. The developed DNA-based biosensor could detect OH
quantitatively with wide linear range up to 10mM and low detection limit of 3μM,
and exhibited satisfactory selectivity. On the other hand, this electrochemical
biosensor could have potential application in the evaluation of antioxidant
capacity.
Graphical abstract
Graphical abstract Highlights
. ►
A DNA-based biosensor for amplified electrochemical detection of OH was
developed. ► The sensor shows good analytical performance for sensitive
detection of OH. ► The biosensor has potential application in the evaluation of
antioxidant capacity.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Wen Zhang, Yaqin
Chai, Ruo Yuan, Shihong Chen, Jing Han, Dehua Yuan In the present work, a
tube-like structure of graphene hybrid as modifier to fabricate electrode for
simultaneous detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and
tryptophan (Trp) was reported. The hybrid was synthesized by a simple method
based on graphene sheets (GS) and 3,4,9,10-perylenetetracarboxylic acid (PTCA)
via π–π stacking interaction under ultrasonic condition. The combination of GS
and PTCA could effectively improve the dispersion of GS, owing to PTCA with the
carboxylic-functionalized interface. Comparing with pure GS or PTCA modified
electrode, GS–PTCA displayed high catalytic activity and selectivity toward the
oxidation of AA, DA, UA, and Trp. Moreover, cyclic voltammetry, different pulse
voltammetry and scanning electron microscopy were employed to characterize the
sensors. The experiment results showed that the linear response range for
simultaneous detection of AA, DA, UA, and Trp were 20–420μM, 0.40–374μM, 4–544μM
and 0.40–138μM, respectively, and the detection limits were 5.60μM, 0.13μM,
0.92μM and 0.06μM (S/N =3). Importantly, the proposed method offers promise for
simple, rapid, selective and cost-effective analysis of small biomolecules.
Graphical abstract
Graphical abstract Highlights
A tube-like structure of
graphene hybrid (GS–PTCA) was synthesized via π–π stacking interaction, and was
used as modifier to fabricate electrode for simultaneous detection of ascorbic
acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). SEM images of GS,
PTCA and GS–PTCA were presented. Under the synergistic effects between GS and
PTCA, the modified electrode displayed high catalytic activity and selectivity
toward the oxidation of AA, DA, UA, and Trp. ► A
simple strategy for simultaneous detection of AA, DA, UA and Trp has been
constructed. ► The tube-like structure of graphene hybrid (GS–PTCA) was
synthesized. ► The GS–PTCA provided a selective interface for discrimination of
AA, DA, UA and Trp.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Elham Tahmasebi,
Yadollah Yamini A novel sorbent for magnetic solid-phase extraction by
self-assembling of organosulfur compound,
(bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid), onto the silver-coated
Fe3O4 nanoparticles was introduced. Due to the formation of covalent bond of
SAg, the new coating on the silver surface was very stable and showed high
thermal stability (up to 320°C). The size, morphology, composition, and
properties of the prepared nanoparticles have also been characterized and
determined using scanning electron microscopy (SEM), energy-dispersive X-ray
analyzer (EDX), dynamic light scattering (DLS), Fourier transform-infrared
(FT-IR) spectroscopy, and thermal gravimetric analysis (TGA). Extraction
efficiency of the new sorbent was investigated by extraction of five polycyclic
aromatic hydrocarbons (PAHs) as model compounds. The optimum extraction
conditions for PAHs were obtained as of extraction time, 20min; 50mg sorbent
from 100mL of the sample solution, and elution with 100μL of 1-propanol under
fierce vortex for 2min. Under the optimal conditions, the calibration curves
were obtained in the range of 0.05–100μgL−1 (R 2
>0.9980) and the LODs (S/N=3) were obtained in the range of
0.02–0.10μgL−1. Relative standard deviations (RSDs) for intra- and
inter-day precision were 2.6–4.2% and 3.6–8.3%, respectively. In addition,
feasibility of the method was demonstrated with extraction and determination of
PAHs from some real samples containing tap water, hookah water as well as soil
samples with relative recovery of 82.4–109.0% and RSDs of 3.5–11.6%.
Graphical abstract
Graphical abstract Highlights
Self assembling of
bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid on Fe3O4@Ag core@shell
nanoparticles and application of it for solid phase extraction of PAHs. ► A novel sorbent for magnetic solid-phase extraction of
PAHs was introduced. ► Silver was coated on Fe3O4 nanoparticles (MNPs) by
reduction of AgNO3 with NaBH4. ► Bis-(2,4,4-trimethylpentyl)-dithiophosphinic
acid self-assembled on silver coated MNPs. ► Size, morphology, composition and
properties of the nanoparticles were characterized. ► Extraction efficiency of
the sorbent was investigated by extraction of five PAHs.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Xavier de la Torre,
Cristiana Colamonici, Davide Curcio, Francesco Molaioni, Francesco Botrè The
confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids
from human urine samples requires extracts of adequate purity. A strategy based
on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary
endogenous androgens (i.e. testosterone, androsterone and/or androstenediols),
is presented. A method without any additional derivatization step is proposed,
allowing to simplify the urine pretreatment procedure, leading to extracts free
of interferences permitting precise and accurate IRMS analysis, without the need
of correcting the measured delta values for the contribution of the derivatizing
agent. The HPLC extracts were adequately combined to both reduce the number of
GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e.
pregnanediol, 11-keto-etiocholanolone) on each GC–IRMS run. The purity of the
extracts was assessed by their parallel analysis by gas chromatography coupled
to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS
assay. The method has been validated according to ISO17025 requirements (within
assay precision below 0.3‰ 13C delta units and between assay
precision below 0.6‰ 13C delta units for most of the compounds
investigated) fulfilling the World Anti-Doping Agency requirements.
Graphical abstract
Graphical abstract Highlights
►
Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS
analysis in doping control. ► Detection of pseudo-endogenous androgenic steroids
(i.e. testosterone, androstenedione) misuse in sports. ► Routine analysis of
steroids by GC/C/IRMS in sports drug testing.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Marcos Bouza,
Beatriz Fernández, Cristina González-Gago, Nerea Bordel, Rosario Pereiro,
Alfredo Sanz-Medel Radiofrequency (RF) millisecond pulsed glow discharge
(PGD) coupled to time-of-flight mass spectrometry (TOFMS) was investigated for
direct elemental analysis of glass samples. Aiming at achieving highest
elemental sensitivity, appropriate discrimination from polyatomics, and good
crater shapes on glasses, a new Grimm-type GD chamber (termed from now “UNIOVI
GD”, designed and constructed in our laboratory) was coupled to TOFMS, and the
results compared with those obtained with the former GD design (here denominated
as “GD.1”) of the initial RF-PGD-TOFMS prototype. The critical differences
distinguishing the two GDs under scrutiny are the GD chamber thickness (15.5mm
for the GD.1 and 7mm for the UNIOVI GD) and the “flow tube” which is inserted in
the GD.1 and inexistent in UNIOVI GD. A pulse period of 4ms and a duty cycle of
50% were selected for the PGD studies. In order to characterizing the UNIOVI GD,
the effect of RF-PGD experimental conditions (pressure and power) on signal
shapes along the pulse was first investigated. Then, the analytical performance
achieved was compared with results obtained using the GD.1 chamber. Results show
that the UNIOVI GD source induced less thermal stress on the glass specimens.
Consequently higher GD power can be applied to the UNIOVI GD (up to at least
130W), as compared to the GD.1 (maximum of 60W), without glass sample breakdown.
Also, better crater shapes on samples were obtained using the UNIOVI GD.
Moreover, the detection limits attained with the UNIOVI GD (in the range of
μgg−1) were in most cases about one order of magnitude better for the
analytes investigated (B, Na, Al, Si, Mn, Ni, Co, Cu, Zn, As, Sr, Ag, In, Sn,
Sb, Ba, Pb and Bi), than those observed using the GD.1.
Graphical abstract
Graphical abstract Highlights
► A
new GD chamber coupled to TOFMS was investigated for direct glass analysis. ►
The effect of GD experimental conditions on signal shapes was investigated. ►
The proposed GD induced less thermal stress on samples than previous GD designs.
► Better detection limits were found compared to those obtained with previous
GDs.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 S. De Baere, A.
Osselaere, M. Devreese, L. Vanhaecke, P. De Backer, S. Croubels A sensitive
and specific method for the quantitative determination of zearalenone (ZEN) and
its major metabolites (α-zearalenol (α-ZEL), β-zearalenol (β-ZEL), α-zearalanol
(α-ZAL), β-zearalanol (β-ZAL) and zearalanone (ZAN)) in animal plasma using
liquid chromatography combined with heated electrospray ionization (h-ESI)
tandem mass spectrometry (LC–MS/MS) and high-resolution Orbitrap®
mass spectrometry ((U)HPLC–HR–MS) is presented. The sample preparation was
straightforward, and consisted of a deproteinization step using acetonitrile.
Chromatography was performed on a Hypersil Gold column (50mm×2.1mm i.d., dp:
1.9μm, run-time: 10min) using 0.01% acetic acid in water (A) and acetonitrile
(B) as mobile phases. Both mass spectrometers were operated in the negative
h-ESI mode. The method was in-house validated for all analytes: matrix-matched
calibration graphs were prepared and good linearity (r ≥0.99) was achieved over
the concentration range tested (0.2–200ngmL−1). Limits of
quantification (LOQ) in plasma were between 0.2 and 5ngmL−1 for all
compounds. Limits of detection in plasma ranged from 0.004 to
0.070ngmL−1. The results for the within-day and between-day
precision, expressed as relative standard deviation (RSD), fell within the
maximal RSD values (within-day precision: RSDmax =2(1–0.5logConc) x
2/3; between-day precision: RSDmax =2(1–0.5logConc)). The accuracy
fell within −50% to +20% (concentrations <1ngmL−1), −30% to +10%
(concentrations between 1 and 10ngmL−1) or −20% to +10%
(concentrations >10ngmL−1) of the theoretical concentration. The
method has been successfully used for the quantitative determination of ZEN in
plasma samples from broiler chickens and pigs. α-ZEL and β-ZEL were the only
metabolites that could be detected, but the concentrations were around the LOQ
levels. The intact ZEN-glucuronide conjugate could be detected using the
(U)HPLC–HR–MS instrument. A good correlation (r 2 =0.9979) was
observed between the results for ZEN obtained with the LC–MS/MS and
(U)HPLC–HR–MS instruments. The results prove the usefulness of the developed
method for application in the field of toxicokinetic analysis and for exposure
assessment of mycotoxins.
Graphical abstract
Graphical abstract Highlights
►
Qualitative+quantitative analyses of zearalenone with LC–MS/MS and
(U)HPLC–HR–MS. ► Development of a generic, rapid and cheap sample preparation
procedure. ► Chromatograhy: baseline separation of metabolites with same
precursor ion, run-time: 10min. ► Method validation: linearity, accuracy,
precision, LOQ, LOD, specificity, recovery and matrix effects. ► Investigation
of toxicokinetics of zearalenone in chickens.
Publication year:
2012 Source:Analytica Chimica Acta, Volume 756 Davinson Pezo, Mauro
Fedeli, Osvaldo Bosetti, Cristina Nerín Toxic primary aromatic amines (PAAs)
are reaction products from residual isocyanates in polyurethane adhesives. The
maximum migration level of the total sum of PAAs is 10ngg−1 of food.
This paper reports on a method for quantification of 18 PAAs by UHPLC–MS/MS that
was optimised and applied to a series of industrial laminates prepared from
polyurethane adhesives. Non-intentionally added substances (NIAS), impurities
and other migrants were identified by Q-TOF/MSE. A comparison of the
quantitative values obtained by the colorimetric method using NEDA and by
UHPLC–MS/MS confirmed that the first method can overestimate the quantification
of PAAs. This could be attributed to the impurities and other NIAS present in
the plastic laminate. Values of R 2 in the analytical characteristics
of UHPLC–MS/MS were obtained, the best value being 0.9964 and the most
unfavourable 0.7626. The detection limit (LOD) and the quantification limit
(LOQ) were 2pgg−1 and 7pgg−1, respectively. The stability
of the PAAs over time in the acidic simulant in contact with the plastic
laminate is also reported.
Graphical abstract
Graphical abstract Highlights
► 18
primary aromatic amines from adhesives in multilayer plastics are analysed by
UPLC–LC–TQ. ► Non intentionally added substances are identified in the
multilayer materials by UPLC–Q-TOF–MS. ► Quantitative values of PAAs are
compared to those obtained by colorimetric method using NEDA. ► Overestimation
of NEDA procedure is demonstrated. ► Pattern recognition of the impurities and
NIAS from adhesives in the multilayers are achieved.
Bruker CAM have released a new GC-MS Environmental Manual
Methods available as a complimentary CD and datafile download via their
website. The manual illustrates how the Bruker SCION™ SQ is ideal for EPA
methods and the link to the methodology enables a quick download of the
datafiles directly to your SCION SQ, to enable immediate running of EPA
methods.
The Environmental Protection Agency
(EPA) and other government bodies are developing evermore stringent screening
policies to monitor the level and effects of pesticides and other contaminants
in the environment. In line with this, the need for fast and robust
quantitative analysis of thousands of samples in complex matrices is growing.
Bruker’s GC-MS Environmental Manual Methods and CD advises on how best to use
the SCION SQ to optimize performance, while fully complying with the required
EPA methods. The methods covered in the manual are EPA Method 524.3
‘Measurement of purgeable organic compounds in water by capillary column gas
chromatography-mass spectrometry’, EPA Method 525.2 ‘Determination of organic
compounds in drinking water by liquid-solid extraction and capillary column gas
chromatography-mass spectrometry’, and EPA Method 8270D – ‘ Semi volatile organic
compounds by gas chromatography-mass spectrometry’. Bruker have structured the
manual around each method, making it easy to identify the section you need.
Each method discusses scope and application, method summary, equipment
parameters, reagents and standards, instrument set-up, expected analytical
results, and trouble shooting.
With a lens-free ion path, active
focussing q0 and extended dynamic range detector, Bruker’s SCION SQ is fast
becoming the instrument of choice for environmental analytics, as it sets new
industry standards for gas chromatography single quadrupole mass detection.
Employing innovative new design features, like the axial flow source which
ensures greater inertness and increased robustness, 90o curved qo to
eliminate neutral noise, and fast scanning quadrupole (14,000 amu/sec) for fast
SIM/Scan acquisition the SCION SQ is the perfect choice for the environmental
laboratory. An upper mass limit of m/z1200 makes the SCION SQ is capable of
handling almost any GC application, hence its suitability for EPA methods
outlined on the CD. Designed to be user-friendly and requiring only simple
maintenance, the SCION SQ is the first choice for any GC-MS application.
The SCION SQ method and data files
for EPA Method 524.3, 525.2 and 8270D can be found in PDF format at www.scionhasarrived.com
or on request as a CD.
Publication year:
2012 Source:Talanta Mohammed M. Rahman, Sher Bahadar Khan, Hadi M.
Marwani, Abdullah M. Asiri, Khalid A. Alamry, Abdulrahman O. Al-Youbi We have
prepared calcined CuO microsheets (MSs) by a wet-chemical process using reducing
agents in alkaline medium and characterized by UV/vis., Fourier transform
infrared (FT-IR) spectroscopy, powder X-ray diffraction (XRD), and
field-emission scanning electron microscopy (FESEM) etc. The detailed
structural, compositional, and optical characterizations of the MSs were
evaluated by XRD pattern, FT-IR, X-ray photoelectron spectroscopy (XPS), and
UV-vis spectroscopy, respectively which confirmed that the obtained MSs are
well-crystalline CuO and possessed good optical properties. The CuO MSs
morphology was investigated by FESEM, which confirmed that the calcined
nanomaterials were sheet-shaped and growth in large-quantity. Here, the
efficiency of the CuO MS was applied for a selective adsorption of gold(III) ion
prior to its detection by inductively coupled plasma-optical emission
spectrometry (ICP-OES). The selectivity of CuO MSs towards various metal ions,
including Au(III), Cd(II), Co(II), Cr(III), Fe(III), Pd(II), and Zn(II) was
analyzed. Based on the adsorption isotherm study, it was confirmed that the
selectivity of MSs phase was the most towards Au(III) ion. The static adsorption
capacity for Au(III) was calculated to be 57.0mgg−1. From Langmuir
adsorption isotherm, it was confirm that the adsorption process was mainly
monolayer-adsorption onto a surface containing a finite number of adsorption
sites.
Highlights
► Selective detection of Gold(III) Ion based on
un-doped CuO Microsheets. ► CuO Microsheets used as a Selective Solid Phase
Adsorbent. ► The static adsorption capacity for Au(III) was calculated to be
57.0mgg−1. ► Adsorption process was mainly monolayer based onto a
surface containing a finite number of adsorption sites
Publication year:
2012 Source:Talanta Dazhong Shen, Yaolong Li, Zhenli Zhang, Ping
Zhang, Qi Kang The impedance of a capacitively coupled contactless
conductivity detector (C4D) in capillary electrophoresis (CE) was
measured by an impedance analysis method. The influence of solution conductivity
and capillary dimension on impedance parameters was investigated. Under the
experimental conditions used, 86–99.9% of the total impedance of a
C4D is composed by its imaginary part from the capillary wall
capacitor. With increasing inner diameter of capillary and solution conductivity
in detection zone, the wall capacitance increases, which results in the increase
in the response signal of C4D. But the wall capacitance is only
0.5–12% of the predicted value according to a cylinder capacitor model. As the
change in solution resistance is detected in a resonant C4D
(RC4D), the sensitivity of contactless conductivity detection in CE
is improved. The application of an end-to-end differential RC4D
(DRC4D) system in CE was demonstrated in the determination of ten
amino acids. The running buffer consisted of 2M acetic acid and 0.1%
hydroxyethylcellulose (pH2.1). The limit of detection for amino acids is in the
range of 0.1–0.4μM. Under our experimental conditions, the sensitivity of
DRC4D enhances by a factor of 15–29as compared with C4D.
Highlights
► The sensitivity of contactless conductivity
detector in capillary electrophoresis is improved. ► The dependence of wall
capacitance on solution conductivity and capillary dimension is reported. ►
Capillary electrophoresis with end-to-end differential detection is reported. ►
The responses of different contactless conductivity detectors are
compared.
Publication year:
2012 Source:Talanta Alejandro Arias, Ricardo J.N. Bettencourt da
Silva, M.Filomena G.F.C. Camões, Cristina M.R.R. Oliveira Abstract The
knowledge of the mass of particulate matter in air, its chemical composition and
emission sources is of relevance for taking decisions concerning air quality
management in urban areas. The interpretation of these data is a function of the
quality of the measurement results expressed by their uncertainties. This study
aimed at developing models of the performance of the determination of anions in
the water-soluble fraction of atmospheric aerosols, capable of determining,
separately, the contribution of aerosols sampling, extraction of water-soluble
fraction of atmospheric aerosols and quantification, by ion chromatography, of
anions in the extract. The sampling procedure was assessed from the dispersion
of results of duplicate parallel sampling after subtracting the analytical
component of this dispersion. These models are used to evaluate the adequacy of
the measurement procedure for the determination of urban aerosol composition and
to support strategies for reducing measurement uncertainty or cost of analysis.
The method performance was studied for the following ranges considering extract
dilution up to five times: 0.23–8µgm−3 for chloride and nitrate, and
0.093–3.25µgm−3 for sulphate. Measurements are fit for the analysis
of urban aerosols since the relative expanded measurement uncertainty is smaller
than a maximum value of 40%. The percentage contribution of the uncertainty
components varies with the analyte and its mass concentration, the major
components being 24–93% for the extraction, 43–59% for sampling, 0.2–28% for the
interpolation of the sample signal in the calibration curve and 4–8% for air
volume measurement. The typical composition of analysed air is: (1.12±0.26)
µgm−3, (1.02±0.30) µgm−3 and (0.76±0.22) µgm−3
of chloride, nitrate and sulphate in the water soluble fraction of aerosol
respectively, for a confidence level of approximately 95% considering a coverage
factor of 2.
Highlights
► Performance of the characterisation of
atmospheric aerosols is assessed. ► Differential approach of the evaluation of
the measurement uncertainty is used. ► Sampling and extraction uncertainty are
estimated separately. ► Strategies for measurement uncertainty and cost of
analysis reduction are proposed. ► Measurements are fit for the analysis of
aerosols since present adequate uncertainty.
Publication year:
2012 Source:Talanta A.J. Bednar, A.R. Poda, D.M. Mitrano, A.J.
Kennedy, E.P. Gray, J.F. Ranville, C.A. Hayes, F.H. Crocker,
Steevens Characterization of nanomaterials must include analysis of both size
and chemical composition. Many analytical techniques, such as dynamic light
scattering (DLS), are capable of measuring the size of suspended nanometer-sized
particles, yet provide no information on the composition of the particle. While
Field Flow Fractionation (FFF) is a powerful nanoparticle sizing technique,
common detectors used in conjunction with the size separation, including UV,
light-scattering, and fluorescence spectroscopy, do not provide the needed
particle compositional information. Further, these detectors do not respond
directly to the mass concentration of nanoparticles. The present work describes
the advantages achieved when interfacing sensitive and elemental specific
detectors, such as Inductively Coupled Plasma Atomic Emission Spectroscopy and
Mass Spectrometry, to FFF separation analysis to provide high resolution
nanoparticle sizing and compositional analysis at the μg/L concentration level,
a detection at least 10 to 100 fold lower than DLS or FFF-UV techniques. The
full benefits are only achieved by utilization of all detector capabilities,
such as dynamic reaction cell (DRC) ICP-MS. Such low-level detection and
characterization capability is critical to nanomaterial investigations at
biologically and environmentally relevant concentrations. The techniques have
been modified and applied to characterization of all 4 elemental constituents of
Cadmium Selenide Zinc Sulfide core-shell quantum dots, and silver nanoparticles
with gold seed cores. Additionally, sulfide coatings on silver nanoparticles can
be detected as a potential means to determine environmental aging of
nanoparticles.
Highlights
► Simultaneous multi-element detection of
nanomaterials. ► Quantum Dot 4 element detection. ► Environmentally relevant
concentrations of nanomaterials. ► Fate and transformation. ► Coating formation,
and transformation, and detection.
Publication year:
2012 Source:Talanta S. Rastegarzadeh, Sh. Abdali A novel optical
method for the determination of thiram has been developed using surface plasmon
resonance peak of gold nanoparticles (AuNPs). The stable and dispersed AuNPs
were directly synthesized by reduction of HAuCl4 with ascorbic acid in micellar
media according to a simple approach. The presence of thiram during formation of
AuNPs results in the decrease of the intensity of plasmon resonance peak. The
variation in the plasmon absorbance allows the colorimetric determination of
thiram. The effect of different variables such as pH, ascorbic acid and CTAB
concentrations was studied and optimized. The proposed method is capable of
determining thiram over a range of 2.0×10−7−1.0×10−5
molL−1 with a limit of detection 1.7×10−7
molL−1. The relative standard deviation of the method was <3.7%.
The method was successfully applied to the determination of thiram in water and
plant seed samples.
Highlights
► A novel optical method for sensitive
spectrophotometric determination of thiram. ► First time ascorbic acid was used
as reducer in detection method by AuNPs plasmon. ► The proposed method has a
simple, fast and eco-friendly procedure. ► In contrast with citrate method, the
AuNPs were formed in situe. ► The LOD is better than other methods based on
spectrophotometric detection.
Publication year:
2012 Source:Talanta S. El-Amrani, J. Sanz-Landaluze, J. Guinea, C.
Cámara A simple and fast approach for a novel bioaccumulation test by
exposing zebrafish eleutheroembryos to fluorene and anthracene (PAHs) at two
concentrations levels below 1% of their LC50 is presented. This alternative
protocol sets an uptake period of 48 hours at 26°C for bioconcentration of the
compounds tested and an additional 24 hours for depuration. Two different
methods to estimate bioconcentration factors (BCFs) of PAHs were used. The first
consists in the ratio between concentrations of the tested compounds in the
zebrafish eleutheroembryos and the exposure media when a steady state during
exposure is reached (BCFss). The second employs the concentration–time profile
with the use of a least-square fit to a non-linear model (BCFk). A steady state
(ss) was reached after 12 hours and 22 hours for fluorene and anthracene
exposure, respectively. Uptake and depuration rate constants obtained were
similar for the two exposure levels tested, hence toxicokinetic rate constants
appeared to be independent of the exposure level. Bioconcentration factors of
1164 and 817 for fluorene exposure at 0.99ngmL−1 and
7.9ngmL−1 and of 2089 and 2344 for anthracene at
0.63ngmL−1 and 6.1ngmL−1 were assessed. The good agreement
of the obtained results with those reported in the literature proves the
feasibility of the proposed method for estimation of both toxicokinetic
parameters and bioconcentration factors. Furthermore, this protocol, has
potential to be an alternative to the OECD (Organisation for Economic
Cooperation and Development) 305 method, considerably reducing time and
associated costs of the test suggested by European legislation.
Highlights
► Zebrafish eleutheroembryos is proven as a
non-animal model to test bioaccumulation. ► For both PAHs tested,
bioaccumulation factors obtained are in the medium-high range. ► Analytical
methodology developed uses small sample amounts and low reagents consumption. ►
Cost of proposed test is much lower than the official ones and much
faster.
Publication year:
2012 Source:Talanta Yuyu Ma, Faqiong Zhao In this work,
3,4-ethylenedioxythiophene (EDOT) emulsion is prepared by ultrasonication
agitation and poly(3,4-ethylenedioxythiophene) (PEDOT) coating is fabricated on
a stainless steel wire by electrochemical method from a 0.10M sodium dodecyl
benzenesulfonate aqueous solution containing EDOT. The coating is characterized
by scanning electron microscopy and Fourier transform infrared
spectrophotometry, and it presents cauliflower-like structure. When the resulted
PEDOT/steel fiber is used for the headspace solid phase-microextraction of some
esters (i.e. methyl anthranilate, dimethyl phthalate, ethyl-o-aminobenzoate,
methyl laurate, diethyl phthalate) and their GC detection, the limits of
detection (LOD) are ca. 7.8–31ngL−1(S/N=3) and the linear ranges are
0.25–800μgL−1. The fiber shows high thermal stability (up to 320°C),
good reproducibility and long lifetime (more than 183 times). It also has good
chemical stability. After it is immersed in acid, alkali and dichloromethane for
4 hours its extraction efficiency remains almost unchanged. Besides esters the
fiber also exhibits high extraction efficiency for alcohols and aromatic
compounds.
Highlights
► A poly(3,4-ethylenedioxythiophene) (PEDOT)
coating is prepared by electrochemical method. ► It shows cauliflower-like
structure and has large surface area and high mass-transport rate. ► When it is
used for SPME, it presents high stability and extraction efficiency for esters.
► This is a new way to make use of different monomers to prepare SPME
fibers.
Publication year:
2012 Source:Talanta Weilu Liu, Jianfu Zhang, Cong Li, Liu Tang,
Zhiquan Zhang, Ming Yang A novel composite film derived from cysteic acid and
poly(diallydimethylammonium chloride)-functionalized graphene (PDDA-GN) was
employed as an enhanced electrode material for ultrasensitive determination of
metronidazole. The cysteic acid/PDDA-GN composite film was prepared by the
electrochemical grafting of cysteic acid onto the PDDA-GN coated glassy carbon
electrode (GCE). The cyclic voltammetry investigations reveal that the peak
current of metronidazole reduction at the cysteic acid/PDDA-GN/GCE was
remarkably enhanced compared to the bare GCE, the cysteic acid/GCE and the
PDDA-GN/GCE. This result implies the synergistic electrocatalytic effect of
cysteic acid and PDDA-GN. The fabricated sensor shows linear response to
metronidazole in the ranges of 10nM - 1µM and 70µM - 800µM, with a detection
limit of 2.3nM (S/N=3). The heterogeneous electron transfer rate constant and
the diffusion coefficient of metronidazole were further evaluated by rotating
disk electrode experiments. Moreover, we applied the present method to the
determination of metronidazole in urine and lake water with satisfactory
results.
Highlights
► Facile microwave-heating procedure for preparing
PDDA-functionalized graphene. ► Cysteic acid/PDDA-functionalized graphene
composite film as a new electrode material. ► High electrocatalytic activity for
metronidazole reduction. ► Wide linear range, low detection limit for the
determination of metronidazole. ► Application in practical samples with
satisfactory results.
Publication year:
2012 Source:Talanta Seungah Lee, Seong Ho Kang Total internal
reflection fluorescence microscopy (TIRFM) was investigated for enhanced
detection sensitivity of cardiac troponin I (cTnI) on a gold nano-patterned
protein chip. A 4×5 nanoarray patterning of a gold chip based on a
single-molecule sandwich immunoassay was prepared with a spot diameter of 500nm
on glass substrates formed via electron-beam nanolithography. Quantitative trace
analysis was possible as a function of increasing total internal reflection
fluorescence intensity in the range of 84aM - 350pM at prism-type and 35aM -
350pM at objective-type TIRFM, respectively. Although using same gold
nano-patterned cTnI chips, however, the objective-type TIRFM showed enhanced
detection sensitivities 2.4 times better than the prism-type due to weaker gold
quenching. This result is also about 7,000 times lower in the detection limit
compared with those obtained by conventional commercial sandwich enzyme-linked
immunosorbent assay techniques.
Highlights
► Quenching effects on gold nano-patterned chips
with a spot diameter of 500 nm. ► Quantitative analysis of cTnI using the prism-
and objective-type TIRFM. ► Stronger quenching efficiency in the prism- than in
the objective-type TIRFM. ► Improved detection sensitivity of cTnI at the aM
concentration level.
Publication year:
2012 Source:Talanta Yun Zhang, Haiyan Liu, Xiaoyan Zhang, Huan Lei,
Bai, Yang A rapid and simple method with online solid phase extraction (SPE)
has been developed for the simultaneous determination of beta-lactam antibiotics
(BLAs) (amoxicillin, cephradine, and cefazolin sodium) in aquatic environment
and milk. The epoxy-based organic-inorganic hybrid monolithic column was used as
SPE sorbent to simultaneously monitor three analytes. The morphology of
monolithic column and pressure drop across the columns were characterized.
Excellent permeability and high selectivity was obtained. The linear range of
the standard curve was from 2.0 to 500ng/mL (r2≥ 0.999). Precision
for inter- and intra-day assay showed acceptable results for quantitative assay
with relative standard deviation (RSD) less than 11%. The accuracy and recovery
were found to be within the range of 93–103% and 83–105%. The results indicated
that the prepared monolithic column could provide excellent reproducibility and
implied that the prepared monolith was feasible to be used as an on-line SPE
sorbent material.
Highlights
► A rapid and simple online solid phase extraction
(SPE) were developed. ► The novel epoxy-based column was used as SPE sorbent to
monitor β-lactam. ► It has a safe, efficient, easy to operate, easy to realize
the advantages of automation. ► Validation was performed at spike concentrations
of 10, 50 and 500 ng mL−1. ► Accuracy, precision, matrix effect,
linearity, LOD and LOQ were assessed.
To protect light sensitive samples - Porvair Sciences offers a selection
of high quality, black microplates and seals that eliminate sample
degradation, even over long storage periods.
Manufactured from ultra-pure grade polypropylene, Porvair black microplates are
resistant to a wide range of solvents and have near zero leachates ensuring
long-term sample integrity. The black plates are supplied RNase / DNase free
meaning they can be used with even the most sensitive biological samples.
Available in a choice of 96-well formats - Porvair black plates are precisely
manufactured to applicable ANSI / SLAS dimensions* ensuring complete
compatibility with almost all readers and automated
equipment.
To prevent evaporation, hydration of DMSO solutions and to completely eliminate
light from samples - Porvair Sciences additionally offers a choice of black,
light absorbing sealing films that may be applied to the top of the black
plates.
For further information on black microplates and sealing films please contact
PorvairSciences on telephone +44-1372-824290 or email int.sales@porvair-sciences.com.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 Yaron
R. Silberberg, Shingo Mieda, Yosuke Amemiya, Toshiya Sato, Takanori Kihara,
Noriyuki Nakamura, Kyoko Fukazawa, Kazuhiko Ishihara, Jun Miyake, Chikashi
Nakamura A cell diagnosis technique was developed, which uses an Atomic Force
Microscope (AFM) and an ultra-thin AFM probe sharpened to a diameter of 200nm
(nanoneedle). Due to the high aspect ratio of the nanoneedle, it was
successfully inserted into a living cell without affecting its viability.
Furthermore, by functionalizing the nanoneedle with specific antibodies and
measuring the unbinding forces (‘fishing forces’) during evacuation of the
nanoneedle from the cell, it was possible to measure specific mechanical
interactions between the antibody-functionalized nanoneedle and the
intracellular contents of the cell. In this study, an
anti-actin-antibody-functionalized nanoneedle was used to evaluate the actin
cytoskeleton state in living cells. To examine the effect of cytoskeleton
condition on the measured fishing forces, the cytoskeleton-disrupting drugs
cytochalasin D (cytD) and Y-27632 were used, showing a marked decrease in the
measured fishing forces following incubation with either of the drugs.
Furthermore, the technique was used to measure the time course changes in a
single cell during incubation with cytD, showing a gradual time-dependent
decrease in fishing forces. Even minute doses of the drugs, the effects of which
were hardly evident by optical and fluorescence methods, could be clearly
detected by the measurement of nanoneedle–protein fishing forces, pointing to
the high sensitivity of this detection method. This technique may prove
beneficial for the evaluation of cytoskeleton conditions in health and disease,
and for the selection of specific cells according to their intracellular protein
contents, without the need for introduction of marker proteins into the cell.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 J.P.
Golden, J. Verbarg, P.B. Howell, L.C. Shriver-Lake, F.S. Ligler A spinning
magnetic trap (MagTrap) for automated sample processing was integrated with a
microflow cytometer capable of simultaneously detecting multiple targets to
provide an automated sample-to-answer diagnosis in 40min. After target capture
on fluorescently coded magnetic microspheres, the magnetic trap automatically
concentrated the fluorescently coded microspheres, separated the captured target
from the sample matrix, and exposed the bound target sequentially to
biotinylated tracer molecules and streptavidin-labeled phycoerythrin. The
concentrated microspheres were then hydrodynamically focused in a microflow
cytometer capable of 4-color analysis (two wavelengths for microsphere
identification, one for light scatter to discriminate single microspheres and
one for phycoerythrin bound to the target). A three-fold decrease in sample
preparation time and an improved detection limit, independent of target
preconcentration, was demonstrated for detection of Escherichia coli 0157:H7
using the MagTrap as compared to manual processing. Simultaneous analysis of
positive and negative controls, along with the assay reagents specific for the
target, was used to obtain dose–response curves, demonstrating the potential for
quantification of pathogen load in buffer and serum.
Highlights
► This paper describes the first integration of the
spinning magnetic trap for automated sample preparation with an analytical
device, the NRL microflow cytometer. ► We have also included improvements in the
microflow cytometer not described elsewhere. ► The data indicate that the
combined components increase the sensitivity and reproducibility of the assays,
simultaneously reducing the assay time significantly.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Hee-Jin Jeong, Yuki Ohmuro-Matsuyama, Hiroyuki Ohashi, Fuyuki Ohsawa,
Yoshiro Tatsu, Masaki Inagaki, Hiroshi Ueda Protein phosphorylation is a key
event in intracellular signal transduction, and fluorescent biosensor for the
specific phosphorylation event in a target protein is considered highly useful
as a tool of cellular biology and drug screening. Vimentin, the most abundant
intermediate filament protein, is phosphorylated at its specific serine (Ser)
residues in a cell cycle dependent manner. Its structural and functional
characteristics are modified by the phosphorylation, which affects biological
properties of the cell. Here we present the detection of the vimentin Ser71
phosphorylation (PS71) and the vimentin Ser82 phosphorylation (PS82) using a
novel fluorescent biosensor Quenchbody, which works on the principle of
antigen-dependent removal of a quenching effect by intrinsic tryptophan residues
on a carboxytetramethylrhodamine (TAMRA) dye incorporated at the N-terminal
region of single chain antibody variable region. First, we found that rhodamine
6G (R6G)-labeled Quenchbody shows superior response than TAMRA-labeled one.
Next, we made several Quenchbodies to detect PS71 and PS82. After optimization
of reaction conditions, the fluorescence intensity of VH-VL type PS71 Quenchbody
labeled with R6G at two positions was increased to 4.0-fold in an antigen
dependent manner. Furthermore, the fluorescence intensity of doubly R6G-labeled
VL-VH type PS82 Quenchbody was increased to 6.7-fold immediately after adding
antigen peptide, also suggesting deeper quenching due to H-dimer formation
between the dyes. Due to its simplicity, the Quenchbody-based phosphorylation
biosensors will be widely applicable to in vitro diagnostics, drug screening and
imaging in a rapid, simple and high-sensitive manner.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Alfredo de la Escosura-Muñiz, Wilanee Chunglok, Werasak Surareungchai,
Arben Merkoçi A high sensitive voltammetric method for rapid determination of
thrombin spiked in whole blood by taking advantage of both aptamer-based
recognition and the use of a nanoporous membrane has been developed. The
nanoporous membrane not only acts as platform for the thrombin recognition but
also as filter of the micrometric components such as white and red blood cells,
consequently minimizing matrix effects. The protocol involves a sandwich format
in the inner walls (200nm diameter) of an anodized alumina oxide filter membrane
(AAO). The analytical signal, by DPV oxidation of [Fe(CN)6]4−, is
based on the blockage in the pores which affects the diffusion of
[Fe(CN)6]4− to the screen-printed carbon electrotransducer (SPCEs)
modified with the membrane. By labeling the anti-thrombin IgG with AuNPs
followed by silver enhancement a greater passive signal enhancement in
comparison to the membrane blockage has been observed. The contribution of both
electrostatic/steric effects in this blockage due to the subsequent formation of
the aptamer-thrombin complex and the final sandwich assay is investigated. The
efficiency of the system is also monitored by microscopic techniques. The
resulted biosensing system allows detecting thrombin spiked in whole blood at
very low levels (LOD 1.8ngmL−1) which are within the range of
clinical interest for the diagnostic of coagulation abnormalities as well as
pulmonary metastasis.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Sylvia R. Scheicher, Birgit Kainz, Stefan Köstler, Norbert Reitinger,
Nicole Steiner, Harald Ditlbacher, Alfred Leitner, Dietmar Pum, Uwe B. Sleytr,
Volker Ribitsch There is a growing demand for functional layers for the
immobilization of (bio)molecules on different kinds of substrates in the field
of biosensors, microarrays, and lab-on-a-chip development. These functional
coatings should have the ability to specifically bind (bio)molecules with a high
binding efficiency, while showing low unspecific binding during the following
assay. In this paper we present rSbpA surface layer proteins (S-layer proteins)
as a versatile immobilization layer for the development of DNA microarrays.
S-layer proteins show the ability to reassemble into two-dimensional arrays on
solid surfaces and their functional groups, such as carboxylic groups, are
repeated with the periodicity of the lattice, allowing for immobilization of
other (bio)molecules. Different fluorescently labeled amino functionalized DNA
oligomers were covalently linked to the S-layer matrices to allow the
characterization of DNA binding on S-layers. Hybridization and dissociation of
DNA-oligomers were studied on S-layer coated slides, revealing low levels of
unspecific adsorption of DNA on S-layer based immobilization matrices. In the
following the principle was transferred to a DNA microarray design showing
successful spotting and hybridization on whole microarray slides. Besides common
laser scanning for fluorescence detection, S-layer based microarrays were
evaluated with a compact, low cost platform for direct fluorescence imaging
based on surface plasmon enhanced fluorescence excitation. It could be shown
that S-layer protein layers are promising as immobilization matrices for the
development of biosensors and microarrays.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Sung-Ho Paek, Il-Hoon Cho, Dong-Hyung Kim, Jin-Woo Jeon, Guei-Sam Lim,
Se-Hwan Paek With the goal of developing a method for the continuous
monitoring of blood glucose, an implantable sensor was developed by placing an
optical fiber probe within the internal hollow space of a syringe needle. A
glucose binder, concanavalin A (Con A), was immobilized on the probe tip and a
protein (e.g., bovine serum albumin) chemically coupled with a sugar ligand
(e.g., mannose) was loaded as a solution inside of the needle, which were then
closed using a semi-permeable membrane. Upon immersion in the glucose sample,
small molecules were able to freely pass through the membrane and compete with
the ligand conjugate for Con A binding. This changed the molecular layer
thickness on the probe surfaces depending on the glucose concentration, which
shifted the wavelength of the guided light along the fiber. Such interference in
the wavelength pattern was measured using a commercial sensor system, Octet,
without employing a label. Using this analytical approach, two major steps
controlling the performance of glucose detection were overcome: permeation of
glucose (optimum with 50nm-porous polycarbonate membrane under the experimental
conditioned used) and molecular diffusion of the ligand conjugate within the
sensor compartment (19 gauge-needle, offering minimal demensions for the probe).
Under optimal conditions, the sensor was able to monitor glucose fluctuations,
even in serum medium, with a response time of less than 15min in a range
10–500mg/dL. This, however, could be further shortened down to about 5min in
principle by miniaturizing the sensor dimensions.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 Takeo
Miyake, Keigo Haneda, Syuhei Yoshino, Matsuhiko Nishizawa Similar to
conventional electrolyte batteries, biofuel cells often need to be stacked in
order to boost their single cell voltage (<1V) up to a practical level. Here,
we report a laminated stack of biofuel cells that is composed of bioanode
fabrics for fructose oxidation, hydrogel sheets containing electrolyte and fuel
(fructose), and O2-diffusion biocathode fabrics. The anode and cathode fabrics
were prepared by modifying fructose dehydrogenase and bilirubin oxidase,
respectively, on carbon nanotubes-decorated carbon fiber fabrics. The total
thickness of the single set of anode/gel/cathode sheets is just 1.1mm. The
laminated triple-layer stack produces an open-circuit voltage of 2.09V, which is
a 2.8-fold increase over that of a single set cell (0.74V). The present layered
cell (5mm×5mm) produces a maximum power of 0.64mW at 1.21V, a level that is
sufficient to drive light-emitting diodes.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 A.
Susloparova, D. Koppenhöfer, X.T. Vu, M. Weil, S. Ingebrandt In this study,
impedance spectroscopy measurements of silicon-based open-gate field-effect
transistor (FET) devices were utilized to study the adhesion status of cancer
cells at a single cell level. We developed a trans-impedance amplifier circuit
for the FETs with a higher bandwidth compared to a previously described system.
The new system was characterized with a fast lock-in amplifier, which enabled
measuring of impedance spectra up to 50MHz. We studied cellular activities,
including cell adhesion and anti-cancer drug induced apoptosis of human
embryonic kidney (HEK293) and human lung adenocarcinoma epithelial (H441) cells.
A well-known chemotherapeutic drug, topotecan hydrochloride, was used to
investigate the effect of this drug to tumor cells cultured on the FET devices.
The presence of the drug resulted in a 20% change in the amplitude of the
impedance spectra at 200kHz as a result of the induced apoptosis process.
Real-time impedance measurements were performed inside an incubator at a
constant frequency. The experimental results can be interpreted with an
equivalent electronic circuit to resolve the influence of the system parameters.
The developed method could be applied for the analysis of the specificity and
efficacy of novel anti-cancer drugs in cancer therapy research on a single cell
level in parallelized measurements.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Carmen C. Mayorga-Martinez, Miquel Cadevall, Maria Guix, Josep Ros, Arben
Merkoçi The rapid determination of trace phenolic compounds is of great
importance for evaluating the total toxicity of contaminated water samples.
Nowadays, electrochemical tyrosinase (Tyr) based biosensors constitute a
promising technology for the in situ monitoring of phenolic compounds because of
their advantages such as high selectivity, low production cost, promising
response speed, potential for miniaturization, simple instrumentation and easy
automatization. A mediator-free amperometric biosensor for phenolic compounds
detection based on the combination of bismuth nanoparticles (BiNPs) and Tyr for
phenol detections will be hereby reported. This is achieved through the
integration of BiNPs/Tyr onto the working electrode of a screen printed
electrode (SPE) by using glutaraldehyde as a cross-linking agent. BiNPs/Tyr
biosensor is evaluated by amperometric measurements at –200mV DC and a linear
range of up to 71μM and 100μM and a correlation coefficient of 0.995 and 0.996
for phenol and catechol, respectively. The very low DC working potential ensures
the avoidance of interferences making this biosensor an advantageous device for
real sample applications. In addition, the response mechanism including the
effect of BiNPs based on electrochemical studies and optical characterizations
will be also discussed. The obtained results may open the way to many other
BiNPs applications in the biosensing field.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 Ming
Xian Lin, Kyung-A Hyun, Hui-Sung Moon, Tae Seok Sim, Jeong-Gun Lee, Jae Chan
Park, Soo Suk Lee, Hyo-Il Jung Circulating tumor cells (CTCs) are identified
in transit within the blood stream of cancer patients and have been proven to be
a main cause of metastatic disease. Current approaches for the size-based
isolation of CTCs have encountered technical challenges as some of the CTCs have
a size similar to that of leukocytes and therefore CTCs are often lost in the
process. Here, we propose a novel strategy where most of the CTCs are coated by
a large number of microbeads to amplify their size to enable complete
discrimination from leukocytes. In addition, all of the microbead labeling
processes are carried out in a continuous manner to prevent any loss of CTCs
during the isolation process. Thus, a microfluidic mixer was employed to
facilitate the efficient and selective labeling of CTCs from peripheral blood
samples. By generating secondary vortex flows called Taylor–Gortler vortices
perpendicular to the main flow direction in our microfluidic device, CTCs were
continuously and successfully coated with anti-epithelial cell adhesion
molecule-conjugated beads. After the continuous labeling, the enlarged CTCs were
perfectly trapped in a micro-filter whereas all of the leukocytes escaped.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Karina Ziółkowska, Agnieszka Stelmachowska, Radosław Kwapiszewski, Michał
Chudy, Artur Dybko, Zbigniew Brzózka In this work, we present a microfluidic
array of microwells for long-term tumor spheroid cultivation and anticancer drug
activity evaluation. The three-dimensional microfluidic system was obtained by
double casting of poly(dimethylsiloxane). Spheroids of HT-29 human carcinoma
cells were cultured in the microsystem for four weeks. After two weeks of the
culture growth slowdown and stop were observed and high cell viability was
determined within next two weeks. The characteristics of a homeostasis-like
state were achieved. A cytostatic drug (5-fluorouracil) was introduced into the
microsystem with different frequency (every day or every second day) and
different concentrations. The geometry and construction of the microsystem
enables flushing away of unaggregated (including dead) cells while viable
spheroids remain inside microwells and decreasing spheroid diameter can be
observed and measured as an indicator of decreasing cell viability. The results
have shown differences in response of spheroids to different concentrations of
5-fluorouracil. It was also observed, that higher frequency of drug dosing
resulted in more rapid spheroid diameter decrease. The presented microfluidic
system is a solution for cell-based studies in an in vivo-like microfluidic
environment. Moreover, observation of decreasing spheroid dimensions is a
low-cost, label-free and easy-to-conduct mean of a quantitative determination of
a 3D cellular model response to a applied drug. It is suitable for long-term
observation of spheroid response, in a contrary to other viability assays
requiring termination of a culture.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue
1 Qiaoli Yue, Tongfei Shen, Changna Wang, Lei Wang, Haibo Li, Shuling Xu,
Huaisheng Wang, Jifeng Liu Conjugations of oligonucleotides, chromophores,
and gold nanoparticles (GNPs) can be used for energy transfer assays to detect
DNA. Herein, a homogenous Förster resonance energy transfer (FRET) system
employing two-step modification of oligonucleotide on GNPs was reported. The
distance between the donor (fluorescein attached onto DNA) and the acceptor
(GNPs) was controlled by using the G-rich DNA. In the presence of porphyrin or
berberine, which can act as ligands of G-quadruplexes, the G-rich DNA spacer can
result into G-quadruplex structure. Therefore, the intimate contact between the
fluorophore and the GNP results in efficient energy transfer and fluorescence
quenching. After hybridization with target DNA, the G-quadruplex stretched and
resulted in an enhancement of fluorescence. So the present FRET system can be
used for target DNA sensing with detection limit as low as 40pM (S/N=3). In this
study, a relation between the fluorescence quenching efficiency and GNP sizes
was found and bigger GNPs had higher fluorescence enhancement after
hybridization with target DNA.
Publication year:
2013 Source:Biosensors and Bioelectronics, Volume 40, Issue 1 A.
Shoshi, J. Schotter, P. Schroeder, M. Milnera, P. Ertl, R. Heer, G. Reiss, H.
Brueckl Adhesion and spreading of cells strongly depend on the properties of
the underlying surface, which has significant consequences in long-term cell
behavior adaption. This relationship is important for the understanding of both
biological functions and their bioactivity in disease-related applications.
Employing our magnetic lab-on-a-chip system, we present magnetoresistive-based
real-time and label-free detection of cellular phagocytosis behavior during
their spreading process on particle-immobilized sensor surfaces. Cell spreading
experiments carried out on particle-free and particle-modified surfaces reveal a
delay in spreading rate after an elapsed time of about 2.2h for
particle-modified surfaces due to contemporaneous cell membrane loss by particle
phagocytosis. Our associated magnetoresistive measurements show a high uptake
rate at early stages of cell spreading, which decreases steadily until it
reaches saturation after an average elapsed time of about 100min. The
corresponding cellular average uptake rate during the entire cell spreading
process accounts for three particles per minute. This result represents a four
times higher phagocytosis efficiency compared to uptake experiments carried out
for confluently grown cells, in which case cell spreading is already finished
and, thus, excluded. Furthermore, other dynamic cell-surface interactions at
nano-scale level such as cell migration or the dynamics of cell attachment and
detachment are also addressable by our magnetic lab-on-a-chip approach.
Highlights
► Magnetoresistive sensing of cell spreading and
particle phagocytosis demonstrated. ► Cells uptaking particles saturate at a
smaller spreading area than reference cells. ► Difference in spreading area
accounts for required membrane area for phagocytosis. ► Sensor signal leads to
average bead-to-surface distance of 120nm after uptake. ► Uptake efficiency of
spreading cells is 4 times higher compared to confluent cells.