World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Monday, 25 February 2013

Parallel Sample Preparation System for HPLC Vials


Porvair Sciences has announced a new version of its MiniVap™ Blowdown Evaporator able to quickly and safely remove solvent from up to 48 vials in parallel.

Made from solvent resistant black polypropylene the new MiniVap Vial Holder has been designed to accommodate up to 48 vials* in a standard SLAS / ANSI format.

Incorporating advanced evaporator head technology which directly injects heated nitrogen into 48 HPLC vials simultaneously, the MiniVap removes the traditional laboratory ‘bottleneck’ of solvent evaporation from vials.

The MiniVap™ Blowdown Evaporator takes just minutes to remove volatile organic solvents from your samples collected in 24- or 96-well microplates and now HPLC vials.



Compact in design the affordably priced MiniVap™ is simple to install, operate and maintain. Installation just requires connection to a gas supply and standard mains socket.  Safety of operation is ensured as the CE marked compact unit fits into all fume cupboards.


Thursday, 21 February 2013

Ju8st Published: Spectrochimica Acta Part B: Atomic Spectroscopy


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Spectrochimica Acta Part B: Atomic Spectroscopy
http://rss.sciencedirect.com/publication/science/5287
Selected papers from the latest issue:

Laser-induced breakdown spectroscopy for light elements detection in steel: State of the art

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

The development of a direct, rapid, and sensitive spectroscopic method for the analytical quantification of light (low atomic number) elements represents an important ongoing challenge. For the first time, we review the evolution of laser-induced breakdown spectroscopy (LIBS) technique for trace analysis of light elements in steels. We present studies carried out in both far/vacuum UV and UV–visible spectral regions, and focus on the elements carbon, sulfur, phosphorous, and nitrogen as their presence and content determine key properties of all steel products. In order to facilitate tracking down the evolution of the technique for a particular element/matrix, the review is organized in such a way that a chronological order has always been obeyed. Moreover, important information regarding characterization of a specific element in a given steel sample is tabulated, so that interested readers can easily locate relevant resources. Furthermore, typical examples of recent developments and advances in terms of LIBS instrumentation and systems regarding light elements in steels are summarized. Finally, the article suggests in brief some approaches for further raising the analytical capability and figures of merit of LIBS regarding trace compositional analysis of light elements. In this respect, we suggest combining LIBS with recently developed diode laser-based techniques such as DLIFS and DLAAS.

Highlights

► We review development of the LIBS technique for trace analysis of light elements. ► This includes recent advances in laser pulse structure and industrial LIBS systems. ► Detection of light elements by LIBS in the optical region is still difficult. ► LIBS combination with either DLIFS or DLAAS would represent a potential solution.

A dried urine spot test to simultaneously monitor Mo and Ti levels using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients that require frequent controls, such as patients with metallic prosthesis, for whom monitoring the evolution of Mo and Ti in biological fluids may play a decisive role to detect prosthesis mal-functioning. The collection of biological fluids on clinical filter papers provides a simple way to implement these protocols. This work explores the potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous and direct determination of Mo and Ti in urine, after its deposition onto clinical filter paper, giving rise to a dried urine spot. The approach used for depositing the sample was found crucial to develop a quantitative method, since the filter paper acts as a chromatographic support and produces a differential distribution of the target analytes. Furthermore, the high spreading of urine onto a filter paper results in a small amount of urine per surface unit, and thus, ultimately, in lack of sensitivity. In order to circumvent these problems, the use of an alternative approach based on the use of pre-cut 17×19mm filter paper pieces onto which larger amounts of sample (500μL) can be retained by single deposition was proposed and evaluated. In this way, an approximately 12-fold increase in sensitivity and a more homogeneous distribution of the target analytes were obtained, permitting the development of a quantification strategy based on the use of matrix-matched urine samples of known analyte concentrations, which were subjected to the same procedure as the samples. Accuracy of this method, which provides LODs of 1.5μgL−1 for Mo and 6.5μgL−1 for Ti, was demonstrated after analysis of urine reference materials. Overall, the performance of the method developed is promising, being likely suitable for determination of other analytes in dried urine spots.

Highlights

► Deposition of urine on clinical filters facilitates home-based collection schemes. ►SS HR CS GFAAS enables direct determination of Mo and Ti in urine dried spots. ► These elements may be used as biomarkers to detect prosthesis malfunctioning. ► The way in which the sample is deposited in the filter is a key to proper quantitation. ► The use of matrix-matched urine standards for calibration is recommended.

Production of metastable 23S1 helium in a laser produced plasma at low pressures

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

We used cavity ringdown spectroscopy to study how the laser ablation of various materials (graphite, aluminum and iron) influences production of 23 S 1 metastable helium in the regime of low pressure helium gas. Plasma was produced by nanosecond Nd:YAG laser at 1064nm with irradiance from 0.8 to 10.9×109 W/cm2. Helium pressure ranged from 0.03 to 0.2mbar. It was found that at higher irradiances, metastable production for all materials reaches saturation due to plasma shielding and is more pronounced for graphite. The highest yield of metastables was found in the case of aluminum target (0.05%). For metals, production rate is discussed in terms of work function and ionization potential.

Highlights

► Production and decay of 23 S 1 metastable He upon laser ablation were studied. ► Various targets in the regime of low helium gas pressures were used. ► CRDS was employed for lineshape measurements of the He 388.8nm transition. ► At larger fluences highest yield of metastables was obtained for aluminum target.

Spectroscopic characterization of atmospheric pressure argon plasmas sustained with the Torche à Injection Axiale sur Guide d'Ondes

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

An argon microwave (2.45GHz) plasma produced by a microwave plasma torch known as “Torche à Injection Axiale sur Guide d'Ondes” (TIAGO) in air ambience at atmospheric pressure was experimentally characterized. The conditions for appropriate TIAGO torch operation in argon and flame morphology were researched under several experimental conditions of gas flow (0.15–5.00L·min–1) rates and microwave input powers (100–1000W). Gas temperature and electron density values were studied by means of optical emission spectroscopy. Besides, the processes inside the discharge and their interaction with the surrounding atmosphere were described according to the recorded spectra.

Highlights

► Ar discharges generated with microwave TIAGO torch were studied by OES. ► Great influence of atmosphere surrounding the flame on discharge parameters ► Electron densities ranging from 1014 cm−3 to 1015 cm−3 depending on argon flow rate ► Gas temperatures ranging from 2500K to 6000K depending on gas flow rate ► Small impact of input power on electron density and gas temperature

The influence of the sample introduction system on signals of different tin compounds in inductively coupled plasma-based techniques

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

The influence of the sample introduction system on the signals obtained with different tin compounds in inductively coupled plasma (ICP) based techniques, i.e., ICP atomic emission spectrometry (ICP–AES) and ICP mass spectrometry (ICP–MS) has been studied. Signals for test solutions prepared from four different tin compounds (i.e., tin tetrachloride, monobutyltin, dibutyltin and di-tert-butyltin) in different solvents (methanol 0.8% (w/w), i-propanol 0.8% (w/w) and various acid matrices) have been measured by ICP–AES and ICP–MS. The results demonstrate a noticeable influence of the volatility of the tin compounds on their signals measured with both techniques. Thus, in agreement with the compound volatility, the highest signals are obtained for tin tetrachloride followed by di-tert-butyltin/monobutyltin and dibutyltin. The sample introduction system exerts an important effect on the amount of solution loading the plasma and, hence, on the relative signals afforded by the tin compounds in ICP–based techniques. Thus, when working with a pneumatic concentric nebulizer, the use of spray chambers affording high solvent transport efficiency to the plasma (such as cyclonic and single pass) or high spray chamber temperatures is recommended to minimize the influence of the tin chemical compound. Nevertheless, even when using the conventional pneumatic nebulizer coupled to the best spray chamber design (i.e., a single pass spray chamber), signals obtained for di-tert-butyltin/monobutyltin and dibutyltin are still around 10% and 30% lower than the corresponding signal for tin tetrachloride, respectively. When operating with a pneumatic microconcentric nebulizer coupled to a 50°C-thermostated cinnabar spray chamber, all studied organotin compounds provided similar emission signals although about 60% lower than those obtained for tin tetrachloride. The use of an ultrasonic nebulizer coupled to a desolvation device provides the largest differences in the emission signals, among all tested systems.

Highlights

► Tin ICP-based signals depend on the compound chemical form. ► Signal differences are related to the compound volatility. ► Signal differences are reduced using high efficient sample introduction systems.

Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

Methods based on laser ablation, such as Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary calculi bulk and micro analysis. Investigation of spatial distribution of matrix and trace elements can help to explain their emergence and growth. However, quantification is still very problematic and these methods are often used only for qualitative elemental mapping. There are no commercially available standards, which would correspond to the urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. The aim of this study is to demonstrate the calibration capabilities and examine the limitations of laser ablation based techniques. Calibration pellets were prepared from powdered human urinary calculi with phosphate, oxalate and urate matrix. For this comparative study, the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover, some alternative techniques such as simultaneous LIBS–LA-ICP-OES and laser ablation LA-LIBS were also utilized.

Highlights

► In this study we compare several laser-ablation based analytical techniques. ► The aim is to prove the calibration capabilities and limitations of these methods. ► Calibration pellets were prepared from human urinary calculi. ► Simultaneous LIBS–LA-ICP-OES, LA-ICP-MS and LA-LIBS were utilized.

Backscattered electron images, X-ray maps and Monte Carlo simulations applied to the study of plagioclase composition in volcanic rocks

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

Zoning patterns in plagioclases are related to abrupt changes in the anorthite content along the crystal growing direction. Accurate characterization of these patterns by electron microprobe is useful to identify magma chamber processes such as recharge, mingling and whole-chamber overturn events. In this work, a new procedure to obtain high resolution quantitative maps of anorthite concentration in single plagioclase crystals is developed. The methodology consists of performing a calibration of backscattered electron images using quantitative X-ray maps. The ultimate resolution of characteristic X-rays and backscattered electron signals is studied by Monte Carlo simulation. The method is applied to characterize the chemical composition of a volcanic plagioclase from the Cerro Vilama, Argentina. The results obtained are more precise than the values given by the methods commonly used in the study of plagioclase composition, i.e. the classical profiling by electron microprobe point analysis or the modern backscattered electron image calibration by means of quantitative energy or wavelength dispersive X-ray analysis at a few selected points.

Highlights

► High resolution maps of anorthite content in single plagioclase crystals were obtained. ► The procedure was tested on volcanic rocks and is suitable for more evolved plagioclases. ► The ultimate resolution of X-rays and BE signal were studied by Monte Carlo simulations. ► MC simulations allowed to explain the BE contrast enhancement due to interface crossing.

Separate K-line contributions to fluorescence enhancement in electron probe microanalysis

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

The behaviour of the fluorescence enhancement correction factor in electron probe microanalysis, as a function of incident electron energy and take-off angle, is assessed for different binary samples in a wide range of compositions. Monte Carlo simulations are employed to validate Reed's correction algorithm [S.J.B. Reed, Characteristic fluorescence corrections in electron-probe microanalysis, Br. J. Appl. Phys. 16 (1965) 913-926], by means of estimating the primary excited radiation volume and the volume corresponding to secondary fluorescence generation. Then, Reed's expression for the fluorescence enhancement has been modified to account for Kα and Kβ line contributions separately. It is clearly shown that in certain cases the assignment of all fluorescent contribution to the Kα lines may be inadequate, particularly when trace element analysis imposes an accurate determination of elemental concentrations.

Highlights

► The fluorescence enhancement correction factor in EPMA is studied. ► Reed's correction formulae were modified to account for Kβ and Kα lines separately. ► The differences evidenced encourage the implementation of complete F corrections. ► Trace elemental concentrations may demand complete assessment of fluorescence factor.

Application of multivariate curve resolution-alternating least squares for the determination of boron isotope ratios by inductively coupled plasma-optical emission spectrometry

21 February 2013, 15:50:38
1 March 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 81

Multivariate curve resolution-alternating least squares (MCR-ALS) was applied to atomic emission data obtained from inductively coupled plasma-optical emission spectrometry analysis of boron for the quantification of 10B/11B ratios. The determination of isotopic composition of boron is based on the isotopic shift of 10B and 11B in the emission line of 208.957nm. After recording of the emission spectra in the range of 208.940–208.970 nm, evaluation of isotopic composition of boron containing samples was performed with MCR-ALS algorithm. MCR-ALS was able to resolve the emission spectra of 10B and 11B mixtures. The performance of the proposed methods was tested by determination of 10B/11B ratios in synthetic mixtures and also water samples.

Highlights

► A new method for the determination of boron isotope ratios by ICP-OES is proposed. ► It is based on the isotopic shift of 10B and 11B in the emission line of 208.957nm. ► MCR-ALS was used for the resolution of the atomic emission spectra of boron isotopes. ► The proposed method presents good statistical parameters.

Pre-Flight Calibration and Initial Data Processing for the ChemCam Laser-Induced Breakdown Spectroscopy Instrument on the Mars Science Laboratory Rover

21 February 2013, 15:50:38
Available online 18 February 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy

The ChemCam instrument package on the Mars Science Laboratory (MSL) rover, Curiosity, is the first planetary science instrument to employ laser-induced breakdown spectroscopy (LIBS) to determine the compositions of geological samples on another planet. Pre-processing of the spectra involves subtracting the ambient light background, removing noise, removing the electron continuum, calibrating for the wavelength, correcting for the variable distance to the target, and applying a wavelength-dependent correction for the instrument response. Further processing of the data uses multivariate and univariate comparisons with a LIBS spectral library developed prior to launch as well as comparisons with several on-board standards post-landing. The level-2 data products include semi-quantitative abundances derived from partial least squares (PLS) regression. A LIBS spectral library was developed using 69 rock standards in the form of pressed powder disks, glasses, and ceramics to minimize heterogeneity on the scale of the observation (350-550μm dia.). The standards covered typical compositional ranges of igneous materials and also included sulfates, carbonates, and phyllosilicates. The provenance and elemental and mineralogical compositions of these standards are described. Spectral characteristics of this data set are presented, including the size distribution and integrated irradiances of the plasmas, and a proxy for plasma temperature as a function of distance from the instrument. Two laboratory-based clones of ChemCam reside in Los Alamos and Toulouse for the purpose of adding new spectra to the database as the need arises. Sensitivity to differences in wavelength correlation to spectral channels and spectral resolution has been investigated, indicating that spectral registration needs to be within half a pixel and resolution needs to match within 1.5 to 2.6 pixels. Absolute errors are tabulated for derived compositions of each major element in each standard using PLS regression. Sources of errors are investigated and discussed, and methods for improving the analytical accuracy of compositions derived from ChemCam spectra are discussed.

Highlights

► We describe a LIBS spectral training set of 69 geological standards. ► ChemCam Mars LIBS data processing is described. Detection limits are given. ► Laser coupling, plasma temperature, accuracy, and precision are detailed.

Non-linear signal response functions and their effects on the statistical and noise cancellation properties of isotope ratio measurements by multi-collector plasma mass spectrometry

21 February 2013, 15:50:38
Available online 16 February 2013
Publication year: 2013
Source:Spectrochimica Acta Part B: Atomic Spectroscopy

A nebulizer-centric response function model of the analytical inductively coupled argon plasma ion source was used to investigate the statistical frequency distributions and noise reduction factors of simultaneously measured flicker noise limited isotope ion signals and their ratios. The response function model was extended by assuming i) a single gaussian distributed random noise source (nebulizer gas pressure fluctuations) and ii) the isotope ion signal response is a parabolic function of the nebulizer gas pressure. Model calculations of ion signal and signal ratio histograms were obtained by applying the statistical method of translation to the non-linear response function model of the plasma. Histograms of Ni, Cu, Pr, Tl and Pb isotope ion signals measured using a multi-collector plasma mass spectrometer were, without exception, negative skew. Histograms of the corresponding isotope ratios of Ni, Cu, Tl and Pb were either positive or negative skew. There was complete agreement between the measured and model calculated histogram skew properties. The nebulizer-centric response function model was also used to investigate the effect of non-linear response functions on the effectiveness of noise cancellation by signal division. An alternative noise correction procedure suitable for parabolic signal response functions was derived and applied to measurements of isotope ratios of Cu, Ni, Pb and Tl. The largest noise reduction factors were always obtained when the non-linearity of the response functions was taken into account by the isotope ratio calculation. Possible applications of the nebulizer-centric response function model to other types of analytical instrumentation, large amplitude signal noise sources (e.g., lasers, pumped nebulizers) and analytical error in isotope ratio measurements by multi-collector plasma mass spectrometry are discussed.

Highlights

► Isotope ion signal noise is modelled as a parabolic transform of a gaussian variable. ► Flicker noise limited isotope ion signals always produced negative skew histograms. ► The corresponding isotope ratio histograms were symmetric, negative or positive skew. ► Skew direction is predictable from relations among the response function coefficients. ► Non-linear signal division improved noise cancellation, typically by 3x to 10x.

Efficient Tool for Polymer Screening

Vortex Overhead Stirring Systems from Asynt Ltd. have helped Parogle Technologies (Liverpool, UK) improve the efficiency with which they synthesise novel dendritic vinyl polymers using solution or emulsion free radical polymerisation reactions.

Parogle Technologies, formerly Hydra Polymers Ltd., was formed in 2007 as a spin-off from Unilever plc. to provide products derived from dendritic vinyl polymer technology including methacrylic, styrenic and polyurethane systems. Parogle Technologies exploit the structure and novel 3D shape of their polymers to provide products with superior properties in a wide variety of applications from paints and lubricants to pharmaceuticals and cosmetics.

Dr Roz Baudry, Senior R&D Chemist at Parogle commented "A magnetic stirrer is fine to make organic molecules, but most of our polymer solutions are too viscous and require using an overhead stirring system”.  She added “We evaluated a range of commercially available multiple position stirred reaction systems before selecting the Asynt Vortex as it incorporated a powerful overhead stirrer and did not require any exotic glassware. Our Vortex systems are used to synthesise branched, grafted or linear polymers in batch or semi-batch processes. They have proven to be very efficient tools for synthesising compounds for polymer screening. We particularly like that the Vortex is very easy to set-up, use and has proven very robust even with the extensive workload at Parogle Technologies".

The Asynt Vortex overhead stirrer system allows three reactions to be stirred simultaneously using a single overhead stirrer and heated to temperatures up to 200C. The ability to perform multiple reactions in parallel enables the Vortex to improve efficiency. The compact Vortex overhead stirrer system is designed to agitate even the most viscous solutions and can be placed on any hotplate stirrer to heat reactions.

For further information on the Vortex overhead stirring system please contact Asynt (+44-1638-781709 / sales@asynt.com) or visit www.asynt.com/product_view.php?ProductID=57. For further information on Parogle Technologies and its novel 3D polymer technologies please visit www.parogle.com.


Wednesday, 20 February 2013

Just Published: Sensors & Actuators B: Chemical


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

Green synthesis of sucralose-capped silver nanoparticles for fast colorimetric triethylamine detection

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

In this study, a fast colorimetric triethylamine sensor based on localized surface plasmon resonance of silver nanoparticles is presented. The nanoparticles were synthesized by chemical reduction from silver nitrate using glucose as reducing agent and sucralose as capping agent. The as-synthesized nanoparticles were characterized using UV–vis spectroscopy, X-ray diffraction, transmission electron microscopy and zeta-potential measurements. Their average size was between 4 and 10nm. The suspension of sucralose-capped silver nanoparticles exhibited high stability and very interesting sensor capabilities for a facile and very fast revealing of the presence of triethylamine. It was found that the injection of triethylamine into silver nanoparticles colloidal solution induced immediate enhancement of the yield of the synthesized nanoparticles and their self-aggregation, depending on the concentration of triethylamine and on the reaction time. This fact resulted in naked-eye color change from pale yellow to dark yellow, orange, greenish orange and gray. This simple and quick determination of the presence of triethylamine has possibilities for applying to environmental applications.

Characterization of an ultrasensitive biosensor based on a nano-Au/DNA/nano-Au/poly(SFR) composite and its application in the simultaneous determination of dopamine, uric acid, guanine, and adenine

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

An ultrasensitive method for the simultaneous determination of dopamine (DA), uric acid (UA), guanine (G), and adenine (A) was developed using differential pulse voltammetry with a three-dimensionally distributed Au nanoparticle (GNP)-modified glassy carbon electrode (GCE). The nano-Au/DNA/nano-Au/poly(SFR)/GCE microstructure was characterized by scanning electron microscopy, electrochemical impedance spectroscopy, and atomic force microscopy, showing an anchored three-dimensional distribution of GNPs on the modified electrode. The electrode exhibited ultrasensitive responses to DA, UA, G, and A due to poly(SFR) electrocatalytic activities and the large surface area of the GNPs. All four analytes showed well-defined catalytic oxidation peaks at the modified electrode. DA, UA, G, and A yielded linear ranges from 8.0×10−9 M to 1.1×10−6 M, 9.0×10−8 M to 1.2×10−5 M, 9.0×10−9 M to 5.0×10−6 M, and 6.0×10−8 M to 8.0×10−7 M, respectively, and detection limits for the analytes were 2.0×10−10 M, 8.0×10−9 M, 5.0×10−10 M, and 4.0×10−9 M, respectively. The feasibility of the proposed assay for use in human serum and urine was investigated and satisfying results were obtained.

Graphical abstract

image

Sensitive and reproducible detection of cardiac troponin I in human plasma using a surface acoustic wave immunosensor

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

We present a sensitive and reproducible surface acoustic wave (SAW) immunosensor that uses an internal reference sensor. A sandwich immunoassay was performed on the working sensing area of the SAW sensor that is able to specifically capture and detect cardiac troponin I (cTnI), while an immunoassay comprising rabbit IgG and anti-rabbit IgG was carried out on the reference sensing area. The analyte in human plasma was captured on gold nanoparticles (AuNPs) that were conjugated in advance with detection antibody. Introduction of these complexes as well as AuNPs conjugated with anti-rabbit IgG into the capture antibody-immobilized working sensor surface and its adjacent rabbit IgG-immobilized reference sensor surface resulted in a classic AuNP-based immunoassay format on both sensing areas. In order to achieve signal enhancement, a gold staining method was performed. Normalized sensor response (a ratio of working sensor response to reference sensor response) due to gold staining varied as a function of applied cTnI concentration. Furthermore, introduction of the internal reference sensor with the normalization technique reduced the coefficient of variation (CV) of the assay by a factor of 4–12, improving reproducibility of the SAW immunosensor. To validate the accuracy of the SAW system, correlation with a commercial system (Centaur®XP, Siemens) was investigated using the plasma of 21 patients and exhibited good agreement with a correlation coefficient (r) of 0.986 and a slope of 0.8 for SAW/Centaur®XP.

Low cost wireless passive microsensors for the detection of hazardous compounds in water systems for control and monitoring

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

In the present work, we studied the design and fabrication of low cost passive microsensors for measuring hazardous compounds. The sensors were fabricated with low cost and biocompatible materials, making them suitable for several industries and applications. These wireless sensors are small enough to be placed inside pipes and recipients of more than 1cm in diameter. Sensors were tested with air, distilled water, acetic acid, pyridine, N,N-dimethylformamide and butanol, presenting high accuracy, repeatability and reproducibility among substances and sensors. The sensors showed a high resistance to corrosion and oxidation after cycling operation. The whole measuring system, that included the sensor and the coupling antenna, proved to be suitable for measuring low dielectric constant and low volatility compounds presenting an average standard deviations in the detection of any compound of 4.23%.

Effect of Sm3+ ion addition on gas sensing properties of Mg1−xCdxFe2O4 system

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

5wt% Sm3+ added nanocrystallite ferrite samples with general formula Mg1−x Cd x Fe2 O4 (x =0, 0.2, 0.4, 0.6, 0.8 and 1) were prepared by oxalate co-precipitation method from high purity sulphates. The XRD, SEM and FT-IR techniques were used for characterization of the samples. The XRD confirms cubic spinel structure with orthoferrite (SmFeO3) secondary phase. The crystallite size varies from 28.69 to 32.66nm. The surface morphology SEM study shows increase in grain size with Cd2+ concentration, while it decrease due to Sm3+ addition in Mg–Cd ferrites. The FT-IR spectra show two strong absorption bands in the range of 350–800cm−1. The response decreases with Cd2+ concentration for LPG, Cl2 while increases for C2H5OH. The response of Sm3+ added Mg–Cd ferrite is higher than Mg–Cd ferrite. The response and recovery time of Sm3+ added Mg–Cd ferrites decreases with increase in Cd2+ concentration and lower than Mg–Cd ferrites. The shorter response and recovery time is observed for Sm3+ added Cd ferrite sensor compared to other samples. The response depend on the composition, test gas and grain size of the material.

Amperometric biosensor based on polypyrrole and tyrosinase for the detection of tyramine in food samples

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

An electrochemical tyrosinase electrode for detection of tyramine was developed via cross-linking immobilization method over phosphate-doped polypyrrole film. The enzyme tyrosinase immobilized over the polypyrrole thin film preserves well its biocatalytic activity. Tyramine was determined by the direct reduction of biocatalytically formed dopaquinone at −0.250V. The analytical characteristics of this biosensor, including linear range, detection limit, repeatability and storage stability are described. The kinetics of the enzymatic reaction fitted into a Michaelis–Menten type kinetic, as confirmed by the h parameter close to 1 obtained from the Hill's plot. Under the optimum conditions, the current response had a linear relationship with the concentration of tyramine in the range of 4–80×10−6 M, with a sensitivity of 0.1069AM−1 and a limit of detection of 5.7×10−7 M. The biosensor exhibited high repeatability and long term stability. Determination of tyramine in real samples showed good recovery. The selective detection is related to specific action of tyrosinase toward phenolic group from tyramine (1-hydroxy-4-ethylaminobenzene). The developed biosensor was applied to the determination of the tyramine content in sauerkraut samples.

Polymeric cantilever sensors functionalized with multiamine supramolecular hydrogel

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

This paper presents a multiamine supramolecular hydrogel (SH) modified SU-8 cantilever sensor. A chemical process to integrate the SH on the surface of SU-8 cantilever is developed to improve the stability and reusability of the functionalized cantilever sensor, instead of physical surface functionalization methods such as direct coating and self-assembly. The network structure of the SH is formed through a ring-opening and amine-substituted reaction in epoxy groups of the SU-8. The surface functionalization of the SU-8 cantilever is characterized by using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The modified SU-8 cantilever sensor has been successfully applied for real-time measurement of metal ions concentration in aqueous solutions. Responses from the cantilever due to surface stress are induced by the axial coordination of ferric ions to amino groups of the SH and the chemical energy is converted into the mechanical energy which can be measured by a piezoresistive sensor. The concentration-dependent performance of the sensor is demonstrated and discussed, indicating a potential use of SH functionalized cantilever sensors.

Hollow, porous, and yttrium functionalized ZnO nanospheres with enhanced gas-sensing performances

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

We report the synthesis of a hierarchical nanostructure of hollow and porous ZnO nanospheres with a high specific surface area as a novel sensing material to toxic formaldehyde by a simple template-free hydrothermal technique in organic solution. We demonstrate that the liquid mixture ratio and hydrothermal time play a pivotal role in forming such unique morphology and propose a growth mechanism of Ostwald ripening coupled with grain rotation induced grain coalescence. Comparison investigations reveal that yttrium allows resistance reduction of sensors and enhances significantly gas-sensing performances of ZnO nanospheres toward the formaldehyde over the commonly used undecorated ZnO nanoparticles. Such hollow, porous, and yttrium functionalized ZnO nanospheres could therefore serve as hybrid functional materials for chemical gas sensors. The results represent an advance of hierarchical nanostructures in enhancing further the functionality of gas sensors, and the facile method presented could be applicable to many other sensing materials.

Cell electrofusion in microfluidic devices: A review

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

Cell electrofusion in microfluidic devices attracted great attention in recent years due to its widespread applications potential in cell-based studies. In these microfluidic devices, many manipulation methods, such as chemical conjugation, electric field induced dielectrophoresis, and microfluidic controlling based on microstructure, are used to improve the pairing precision of cells, especially heterogeneous cells. High-strength electric field can produce minipores on cell membrane and induce cell fusion. It can be generated by a constricting electric field with microstructures or two microelectrodes. In comparison with the traditional electrofusion or other cell-fusion methods, microfluidic cell-electrofusion method has many advantages such as precise manipulation, high efficiency in cell pairing and fusion, higher cell viability, lower sample contamination and smaller Joule heating effect. In this article, the development of various microfluidic cell-electrofusion methods is reviewed. Some important parameters affecting the cell electrofusion are discussed in detail. Techniques that can be integrated on microfluidic devices for high-efficiency cell electrofusion, such as on-chip cell separation and culture, are also discussed comprehensively.

Fabrication of smart COC chips: Advantages of N-vinylpyrrolidone (NVP) monomer over other hydrophilic monomers

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

This paper presents a comparative study on surface modification of cyclic olefin copolymer (COC) through UV-photografting with acrylic acid (AAc), acrylamide (AAm), 2-hydroxyethyl methacrylate (HEMA) and N-vinylpyrrolidone (NVP) monomers with the aim to identify the most suitable process for the development of smart capillary electrophoresis LOC devices with excellent biocompatible channel surfaces. It was noticed that all the surface treatments enable to generate extremely high thermal bond strength at temperatures well below the glass transition temperature (T g) of the COC polymer, ensured that the dimensions of the microchannels in the chip remains unaltered after thermal sealing. However, the NVP grafted substrates exhibits the highest bonding strength which is about 203% higher than that of the untreated sample. The contact angle measurement indicates that the NVP grafted surfaces have the highest surface wettability than that of AAc, AAm and HEMA modified surfaces. UV–vis spectroscopy measurement reveals that of the four modified surfaces the NVP grafted COC shows the highest optical clarity. The in vitro platelet adhesion and protein adsorption experiment indicates that the NVP grafted substrates are extremely biocompatible. These results clearly demonstrate that the UV-photografting using NVP is indeed a promising surface modification technique for constructing COC capillary electrophoretic chips for protein and peptide separation.

Simultaneous measurement of refractive index and temperature based on a partial cone-shaped FBG

20 February 2013, 09:42:27
1 March 2013
Publication year: 2013
Source:Sensors and Actuators B: Chemical, Volume 178

A refractive index and temperature simultaneous measurement sensor based on a partial cone-shaped fiber Bragg grating (FBG) was demonstrated. The bandwidth of the partial cone-shaped FBG is only affected by the surround refractive index (SRI), while the wavelength decided by the un-etched FBG is only sensitive to temperature. Utilizing the obvious difference of the bandwidth and the wavelength on the refractive index and temperature, two parameters can be distinguished and measured simultaneously using one partial cone-shaped FBG. Numerical simulation and experimental results are presented. Experimental results show that the proposed sensor has an average SRI sensitivity of −18.027nm/RIU in the SRI range of 1.33–1.42 and a temperature sensitivity of 9.8pm/°C in the range of 20–80°C. 

NETZSCH to Supply SpaceX’s Thermal Analysis Laboratory


Netzsch Instruments North America, LLC (Netzsch) is proud to announce that it is currently the sole supplier to Space Exploration Technologies Corp. (SpaceX) of high temperature thermal analysis instruments used to characterize material properties for space applications. The instruments will be used to fine tune properties of existing materials and to develop new materials for use in the demanding, harsh environments of space. The ability of Netzsch to custom engineer and modify the instruments to meet SpaceX’s requirements was a key factor in their choice of vendors.
SpaceX is transforming the way rockets and spacecraft are made. It is the only private company ever to return a spacecraft from low-Earth orbit, and the first to send a spacecraft to the International Space Station -- a technically challenging feat previously accomplished only by governments. In October 2012, SpaceX’s Dragon spacecraft again successfully delivered cargo to and from the space station, in its first official cargo resupply mission for NASA.
Mission critical material will be developed, tested and modeled using data from Netzsch’s Thermokinetics software.  Therefore the precision and accuracy of the data is of the upmost importance and is why Netzsch Instruments were chosen over other vendors for this role.
Netzsch instruments will be used to measure basic material properties along with other thermophysical properties.  Some of these properties will include 1st, 2nd and 3rd order transitions, coefficient of thermal expansion and contraction, modulus, energy adsorption dampening, heat capacity, thermal diffusivity, thermal conductivity along with software and heat transfer data to model and build heat management systems.

About SpaceX
SpaceX (Hawthorne, CA)  designs, manufactures, and launches the world's most advanced rockets and spacecraft. The company was founded in 2002 by Elon Musk to revolutionize space transportation, with the ultimate goal of enabling people to live on other planets. Today, SpaceX is advancing the boundaries of space technology through its Falcon launch vehicles and Dragon spacecraft. SpaceX is a private company owned by management and employees, with minority investments from Founders Fund, Draper Fisher Jurvetson, and Valor Equity Partners. The company has more than 2,000 employees in California, Texas, Washington, D.C., and Florida. For more information, visit www.SpaceX.com.

About Netzsch
Netzsch Instruments North America (Burlington, MA) develops and manufactures a complete high-precision instrument line for thermal analysis and thermophysical properties measurement, as well as offering world class commercial testing services in our laboratories. Our instrumentation is employed for research and quality  control in the polymer sector, aerospace,  chemical industry,  inorganic and building materials, and environmental analysis. Instruments for controlling – such as for in-situ cure monitoring – complete our product line. For more information, visit www.netzsch-thermal-analysis.com

Model DV22 Mini Diaphragm Valve


VICI’s Microvolume Diaphragm Valve is designed for trouble-free use in applications requiring minimal maintenance and maximum lifetime, making it the ideal choice for the process industry, automated lab analyzers, and continuous-monitoring environmental analyses. Three configurations are available: a 4 port internal loop sample injector; a 6 port external loop sampling/switching valve; and the industry’s first 10 port multifunctional diaphragm valve.    

Lifetime for the DV22 can exceed 1,000,000 cycles at ambient temperature/300 psi or 500,000 cycles at 175°C/300 psi. The standard valve is for applications in which the sample is above ambient pressure, but it can also be used with sub-ambient pressures, such as when the sample is pulled through the valve by vacuum.

Actuator air (40-50 psi) is supplied to a side port with 10-32 female threads, permitting use of a variety of compression or barbed fittings. A 3-way solenoid is required for actuation, which may be ordered separately.

Maintenance procedures are greatly simplified, since the valve is held together by a single screw and locating pins insure proper alignment.    

Tuesday, 19 February 2013

High Throughput Natural Product Discovery

A technical article from Genevac is available that details how its HT-24 centrifugal evaporation system is assisting a commercial flavours and fragrance company in its quest to find and isolate novel flavour ingredients from nature.

Natural product derived discovery of novel flavour molecules is a highly complex process.  Natural product sources yield complex extracts containing many components, which often do not lend themselves to processing and analysis. Conventionally, many steps of fractionation and evaluation are necessary until a compound is obtained from natural sources at the purity required for structural analysis. In the article a state of the art fractionation process using a Sepbox® Preparative HPLC - SPE system* and a Genevac® HT-24 centrifugal evaporator is described. The Sepbox enables two dimensional, preparative scale fractionation of natural products using high performance liquid chromatography – solid phase extraction (HPLC-SPE). In sequential HPLC-SPE / HPLC-SPE steps individual components are isolated from complex mixtures. Each separation run produced 320 samples of approximately 45ml volume.

A Genevac HT-24 Evaporator was chosen to dry the samples because of its high sample capacity, unique technology that eliminates cross contamination due to sample bumping and automated monitoring of temperature and pressure to prevent sample degradation.  Able to evaporate 192 sample vials simultaneously the HT-24 took just two days to dry all the fractions ready for further liquid handling and testing.

Compact in design and offering a very high capacity for a wide range of sample formats including microplates, tubes, vials, fraction collector racks and Genevac’s hybrid HPLC blocks the HT-24 offers the versatility and productivity to assist chemists in high-throughput environments. The high-throughput design of the HT-24 allows up to 96 shallow-well microplates to be dried down at the same time, while capacity for standard 16 x 100mm fraction collector tubes is an outstanding 576 tubes per run. Benefiting from Genevac’s 20+ years of designing centrifugal evaporators the HT-24 is easy to use, reliable, robust and safe to both operator and sample integrity. Further aiding productivity the HT-24 includes facility for rapid defrosting, and pull-out sample shelves for easy loading and unloading.

To download a company of the article please visit http://genevac.com/en/ArticleDetail.asp?S=6&V=1&ProductDownload=144. For further information on the evaporators for high throughput natural product research please contact Genevac on +44-1473-240000 / +1-845-255-5000 or email salesinfo@genevac.co.uk.