World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Thursday 13 September 2012

Just Published:Journal of Chromatography B


A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue:

The development and validation of a turbulent flow chromatography–tandem mass spectrometry method for the endogenous steroid profiling of equine serum

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Benjamin C. Moeller, Scott D. Stanley
A method for the detection and quantitation of 35 endogenous steroids in equine serum was developed and validated. Androgens, estrogens, progestins and their metabolites potentially present in serum were simultaneously monitored in one method using on-line sample extraction by turbulent flow chromatography (TFC) on a 2-dimensional liquid chromatography system and detected on a triple-stage quadrupole mass spectrometer by electrospray ionization. Analytes were detected and quantitated by single-reaction monitoring or selected-ion monitoring. Limits of detection (range 0.025–10ngmL−1) and quantitation (range 0.125–25ngmL−1) along with recovery and matrix effects were determined for each analyte. Inter- and intra-day accuracy and precision was assessed for with the majority of analytes having %CV less than 20% and accuracy within 20% of the expected concentrations. Eight of the 35 analytes were unable to meet these guidelines across all of the quality control concentrations monitored for each analyte. This method was used to determine the endogenous steroid profiles of Thoroughbred horses and has been modified for use in non-human primates and cell culture.

Highlights

► Validated method for analysis of 35 endogenous steroids in equine serum. ► Androgens, estrogens, and progestins are monitored in one method. ► Turbulent flow chromatography allows for minimal sample processing. ► Allows for analysis of multiple steroids in one run from 300μL serum.

Liquid chromatographic mass spectrometric (LC/MS/MS) determination of plasma hydroxocobalamin and cyanocobalamin concentrations after hydroxocobalamin antidote treatment for cyanide poisoning

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Harvey A. Schwertner, Sandra Valtier, Vikhyat S. Bebarta
Cyanide poisoning occurs in individuals after fire smoke inhalation and after oral ingestion of cyanide. Hydroxocobalamin (HOCbl), a hydroxylated form of vitamin B12, is often used as an antidote to treat cyanide toxicity. It has a high affinity for cyanide and rapidly removes cyanide from tissue by forming cyanocobalamin (CNCbl). Little information is available on the pharmacokinetics of HOCbl and CNCbl largely because of the lack of analytical methods for analyzing HOCbl and CNCbl. In this study, we developed a new liquid chromatographic mass spectrometric (LC/MS/MS) method for the quantitative analysis of plasma HOCbl and CNCbl in the porcine (Sus scrofa) model. The method uses on-column extraction, reversed phase gradient chromatography, and multiple reaction monitoring (MRM) for quantitation. MRM transitions monitored were 664.7→147.3 and 664.7→359.2 for HOCbl and 678.8→147.3, 678.8→359.1 678.8→457.1 for CNCbl. The limit of detection (LOD) and the lower limit of quantitation (LLOQ) were 1.0 and 1.0μmole/L, respectively, for plasma HOCbl and 0.1 and 0.5μmole/L for plasma CNCbl. The within-day and between-day CVs were 4.3 and 6.4% for plasma HOCbl at 500.0μmole/L and 5.5 and 5.7% for CNCbl at 100.0μmole/L (n =6). The plasma HOCbl and CNCbl calibrations curves were linear from 100.0 to 2000.0 and 50.0 to 500.0μmole/L, respectively. Based on 6 separate calibration curves the average linear regression coefficient (R 2) for both HOCbl and CNCbl was 0.992. The LC/M/MS method was found to be accurate and precise and has been validated by determining the plasma HOCbl and CNCbl concentrations in 11 pigs that were treated with HOCbl for cyanide poisoning.

Highlights

► LC/MS/MS method for analyzing plasma hydroxocobalamin and cyanocobalamin. ► Use of hydroxocobalamin in porcine animal models with induced cyanide poisoning. ► Plasma hydroxocobalamin and cyanocobalamin levels after hydroxocobalamin treatment.

Breath biomarkers of liver cirrhosis

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Jesica Dadamio, Sandra Van den Velde, Wim Laleman, Paul Van Hee, Wim Coucke, Frederik Nevens, Marc Quirynen
The diagnosis of asymptomatic cirrhosis in patients with liver disease is of importance to start screening for complications in due time. Liver biopsy is neither sensitive nor practical enough to be used as a frequent follow-up test in patients with chronic liver disease. The volatile organic compounds present in exhaled breath offer the possibility of exploring internal physiologic and pathologic process in a non invasive way. This study examined whether a specific pattern of biomarkers can be found in breath samples of patients with cirrhosis. To this aim samples of alveolar breath from patients with cirrhosis and healthy volunteers were analyzed using gas chromatography–mass spectrometry. When linear discriminant analysis was used to search for a model(s)/pattern of compounds characteristic for liver cirrhosis, 24 models of 8 independent compounds could distinguish between the groups. The sensitivity and specificity (between 82% and 88%, and 96% and 100%, respectively) of the models suggest that a specific pattern of breath biomarkers can be found in patients with cirrhosis, which may allow detecting this complication of chronic liver disease in an early stage.

Highlights

► We used TD/GC/MS to analyze the breath composition of patients with cirrhosis. ► We compared their breath profiles with healthy volunteers. ► Linear discriminant analysis identified 24 models. ► Sensitivity and specificity varied between 82% and 88%, and 96% and 100%, respectively. ► Patients with cirrhosis have a specific pattern of breath biomarkers.

Concentration and selective fractionation of an antihypertensive peptide from an alfalfa white proteins hydrolysate by mixed ion-exchange centrifugal partition chromatography

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Leslie Boudesocque, Romain Kapel, Cedric Paris, Pascal Dhulster, Ivan Marc, Jean-Hugues Renault
This article reports a promising use of the mixed ion-exchange centrifugal partition chromatography (MIXCPC) technique in the field of downstream processes. A complex alfalfa white protein concentrate hydrolysate (AWPC hydrolysate) showing anti-hypertensive properties was successfully fractionated by MIXCPC to yield a l-valyl-l-tryptophan (VW) enriched fraction in one run. This dipeptide shows an interesting anti-angiotensin converting enzyme (anti-ACE) activity. An analytical method based on RP-LC/MS-MS was developed to quantify the target VW peptide in both the starting material and the enriched fractions. The best results for the MIXCPC fractionation were obtained by the combined use of the quaternary biphasic solvent system, methyl-tert-butylether/acetonitrile/n-butanol/water (2:1:2:5, v/v) in the descending mode, of the lipophilic di(2-ethylhexyl)phosphoric acid (DEHPA) cation-exchanger with an exchanger (DEHPA)/peptides ratio of 15, and of two displacers: calcium chloride and hydrochloric acid. The complexity of the starting material involved the selectivity optimization by splitting the stationary phase into two sections that differed by their triethylamine concentration. From 1g of AWPC hydrolysate containing 0.26% of VW, 30.7mg of a VW enriched fraction were recovered with a purity of 10.9%, corresponding to a purification factor of 41 and a recovery of 97%.

Highlights

► Fractionation of bioactive peptides by centrifugal partition chromatography (CPC). ► Efficiency of the ion-exchange CPC mode in the field of downstream processes. ► Optimization of the exchanger/analyte ratio. ► Quantification of the target dipeptide by RP-HPLC–MS/MS.

High sensitivity measurement of amino acid isotope enrichment using liquid chromatography–mass spectrometry

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Hans M.H. van Eijk, Karolina A.P. Wijnands, Babs A.F.M. Bessems, Steven W. Olde Damink, Cornelis H.C. Dejong, Martijn Poeze
Measurement of the incorporation or conversion of infused stable isotope enriched metabolites in vivo such as amino acids plays a key role in metabolic research. Specific routes are frequently probed in knockout mouse models limiting the available amount of sample. Although less precise as compared to combustion-isotope ratio mass spectrometry (C-IRMS), gas chromatography–mass spectrometry (GC–MS) or liquid chromatography–mass spectrometry (LC–MS) techniques are therefore often the method of choice to measure isotopic enrichment of target metabolites. However, under conditions of metabolic depletion, the precision of these systems becomes limiting. In this paper, studies were performed to enhance the sensitivity and precision of isotope enrichment measurements using LC–MS. Ion-statistics and resolution were identified as critical factors for this application when using a linear trap mass spectrometer. The combination with an automated pre-column derivatization and a carefully selected solvent mix allowed us to measure isotopic enrichments down to 0.005% at plasma concentrations as low as 5μmol/l, an improvement by a factor of 100 compared to alternative methods. The resulting method now allowed measurement of the in vivo conversion of the amino acid arginine into citrulline as a marker for the production of nitric oxide in an in vivo murine endotoxemia model with depleted plasma levels of arginine and citrulline.

Highlights

► Amino acid (AA) isotope enrichment down to 0.005% at 5μM concentrations. ► Special focus on low arg and cit due to LPS treatment. ► Use OPA derivatization of AA combined with RP-HPLC and MS analysis.

A HILIC–MS/MS method for the simultaneous determination of seven organic acids in rat urine as biomarkers of exposure to realgar

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Yin Huang, Yuan Tian, Zunjian Zhang, Can Peng
Realgar (As4S4) is a traditional medicine used in China and Europe for thousands of years. As an arsenical, the toxicity from realgar has raised public concern. Several organic acids in urine are found to be potential biomarkers of realgar exposure, including taurine, citric, glutamic, lactic, pyruvic, succinic and uric acid. In this study, using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS), a rapid and sensitive method was developed to separate and quantify these compounds in urine. A ZIC®-HILIC column was used for the separation at an isocratic condition of acetonitrile and 10mM ammonium acetate in water. Analytes were detected in multiple-reaction monitoring with negative ionization mode, using ibuprofen as internal standard. Good line arities (R 2 >0.996) were obtained for all analytes with the limits of detection from 0.2 to 0.7μg/mL. The intra-day and inter-day accuracy ranged from 89.1 to 104.4% and the relative standard deviation (RSD) did not exceed 15.0%. The recovery was more than 80%with RSD less than 14.0%. The validated method was applied to analyze the urine samples of control and reaglar treated rats, and significant changes of these organic acids were observed.

Post acquisition data processing techniques for lipid analysis by quadrupole time-of-flight mass spectrometry

13 September 2012, 05:52:26
Publication year: 2012
Source:Journal of Chromatography B, Volume 905
Tong Xie, Yan Liang, Jiye A, Haiping Hao, Linsheng Liu, Xiao Zheng, Chen Dai, Yuanyuan Zhou, Tianye Guan, Yanna Liu, Lin Xie, Guangji Wang
This study describes the effectiveness of post-acquisition data processing techniques in detecting the lipid species rapidly from the massive data generated by high resolution mass spectrometry. The filtering approaches by product ions or neutral losses enabled glycerophospholipids and sterol conjugates to be identified based on the investigation of their fragmentation patterns, and the filtration by mass defect facilitated the detection of fatty acyl residues and bile acids by limiting the range of mass defect values. After application of these filtering techniques to mass spectra, the background noise was significantly filtered out and characteristic peaks of lipid species were efficiently sorted out. Totally 145 individual lipids were identified and structurally elucidated. Validation results of the LCMS-Q-TOF-based quantitative performance for all the peaks showed that the accuracy, expressed as relative errors (RE%), was lower than ±15%, and values (RSD%) of the inter-batch and intra-batch precision were lower than 15% in the assay. The developed method was integrated to the evaluation of plasma lipid profile from high fat diet versus energy restricted diet fed rats. A unique discrimination of the groups was successfully achieved through a principal component analysis (PCA).

Highlights

► Lipidomic analysis of rats’ plasma was studied. ► 145 lipids were detected by data processing techniques. ► Thirteen differential features could be highlighted upon using the described methodology.

1 comment:

  1. Thanks for providing these journals on Chromatography .This technique is really helpful to learn more about photography concepts.
    Liquid Chromatography

    ReplyDelete