World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Wednesday, 6 July 2011

BladeCell Disposable Cuvette Improves DLS Productivity

Avid Nano have written a new report that demonstrates how their unique BladeCell™ disposable cuvette improves Dynamic Light Scattering (DLS) sample preparation time by a factor of 8 compared to using traditional quartz cuvettes.

The patent-pending 5µl BladeCell™ cuvette combines the ultimate convenience of a disposable sample holder with the measurement quality of a quartz cuvette.  Precision moulded in black polycarbonate the BladeCell requires no sample preparation beyond centrifuging to reduce the possibility of dust contamination that can affect DLS measurements.  To fill - 5µl of sample is simply pipetted against the walls of the BladeCell liquid trap where it is retained by surface tension.  The prepared cuvette is placed into the temperature controlled sample holder of the Avid Nano W130i, where it can be analysed by DLS in seconds.  After analysis the sample is recovered by simply dipping a pipette tip into the liquid trap and removing the contents.  As a low cost cuvette the BladeCell may now be disposed of eliminating the cleaning steps required when using more costly quartz cuvettes.

Exclusively available from Avid Nano for use on the W130i DLS system - the BladeCell is a ground breaking innovation making low volume batch DLS measurements faster, easier and more convenient than ever before.  For a copy of the new report please visit http://www.avidnano.com/8xfaster.htm or contact Avid Nano on +44-1494-614659 or email info@avidnano.com

Tuesday, 5 July 2011

Just Published: Journal of Chromatography B

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Rapid UHPLC determination of polyphenols in aqueous infusions of Salvia officinalis L. (sage tea)

04 July 2011, 21:39:20Go to full article
Publication year: 2011
Source: Journal of Chromatography B, In Press, Accepted Manuscript, Available online 3 July 2011
Benno F., Zimmermann , Stephan G., Walch , Laura Ngaba, Tinzoh , Wolf, Stühlinger , Dirk W., Lachenmeier
Sage tea, the aqueous infusion of dried sage leaves (Salvia officinalis L.), is used as a form of food as well as a form of traditional herbal medicine. Several in vivo and in vitro studies point to sage polyphenols as active principles that may inhibit lipid peroxidation and improve antioxidant defences. This study describes an UHPLC methodology with MS/MS and UV detection, which allows the separation, identification and quantification of the major phenolic constituents in sage tea within 34min, and was used to characterize 16 commercial brands of sage tea. The quantitatively dominating compounds were either rosmarinic acid (12.2 to...

Development and validation of a sensitive LC/MS/MS method for the simultaneous determination of naloxone and its metabolites in mouse plasma

04 July 2011, 21:39:20Go to full article
Publication year: 2011
Source: Journal of Chromatography B, In Press, Accepted Manuscript, Available online 3 July 2011
Hongliang, Jiang , YuRong, Wang , Manjunath S., Shet , Yang, Zhang , Duane, Zenke , ...
A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50mm×2.1mm, 5μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5minutes with a flow rate of 1.0mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction...

On-line coupling of dynamic microwave-assisted extraction with high-speed counter-current chromatography for continuous isolation of nevadensin from Lyeicnotus pauciflorus Maxim

04 July 2011, 21:39:20Go to full article
Publication year: 2011
Source: Journal of Chromatography B, In Press, Accepted Manuscript, Available online 2 July 2011
Xing, Tong , Xiaohua, Xiao , Gongke, Li
An on-line method based upon dynamic microwave-assisted extraction (DMAE) coupled with high-speed counter-current chromatography (HSCCC) was developed for continuous isolation of nevadensin from Lyeicnotus pauciflorus Maxim. The DMAE parameters were optimized by means of the Box-Behnken design. The maximum extraction yield was achieved using 30:1ml/g of liquid-solid ratio, 10ml/min of solvent flow rate and 200W of microwave power. The crude extracts were then separated by HSCCC with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (7:3:5:5, v/v/v/v). 13.0mg of nevadensin was isolated from 15.0g original sample by HSCCC with five times sample injection in 12h, and the isolation yield of...

QUANTITATIVE DETERMINATION OF T-2 TOXIN, HT-2 TOXIN, DEOXYNIVALENOL AND DEEPOXY-DEOXYNIVALENOL IN ANIMAL BODY FLUIDS USING LC-MS/MS DETECTION

04 July 2011, 21:39:20Go to full article
Publication year: 2011
Source: Journal of Chromatography B, In Press, Accepted Manuscript, Available online 2 July 2011
S., De Baere , J., Goossens , A., Osselaere , M., Devreese , V., Vandenbroucke , ...
A sensitive and specific method for the quantitative determination of deoxynivalenol (DON), deepoxy-deoxynivalenol (DOM-1), T-2 toxin (T-2) and HT-2 toxin (HT-2) in animal body fluids (plasma and bile) using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is presented.The extraction of plasma consisted of a deproteinization step using methanol, followed by a clean-up using an Oasis® HLB solid-phase extraction column. For bile analysis, an extraction using a methanol/water mixture (70/30, v/v), followed by a liquid-liquid extraction using ethyl acetate, was performed.Chromatographic separation was achieved on a reversed-phase Nucleosil (100-5 C18 G100×3.0mm) column. For the analysis of DON and...

Simultaneous Determination of Fifteen Illegal Dyes in Animal Feeds and Poultry Products by Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry

04 July 2011, 21:39:20Go to full article
Publication year: 2011
Source: Journal of Chromatography B, In Press, Accepted Manuscript, Available online 2 July 2011
Rongyuan, Liu , Wenjing, Hei , Pingli, He , Zhen, Li
With the increasing presence of illegal dyes, such as sudan reds and malachite green, in animal feeds and food products duirng the last few years, there is an urgent need of accurate quantitative determination methods for these illicit compounds. Here we established an accurate method for the simultaneous determination of 15 illegal dyes in animal feeds, meat, eggs and other food products using ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The samples were extracted with a simple procedure using acetonitrile and solid phase extraction cleaning up. The application of C18 rapid column can achieve satisfactory separation of the 15...

Automated Sample Preparation for Targeted Resequencing

Fluidigm has announced that the Broad Institute of MIT and Harvard has purchased an Access Array™ System to automate its sample preparation for targeted resequencing.

The Access Array System enhances the capabilities of powerful next-generation sequencing platforms by allowing the preparation of several sample libraries in parallel. The multiplexed Access Array sample prep system enables parallel amplification of 48 samples - the equivalent of 48 sequencing libraries - in a few hours. The system is used for target enrichment, sample barcoding for multiplexed sequencing, and sequencing library preparation using amplicon tagging.

"We expect our Access Array System's ability to use very small amounts of sample and prepare libraries for amplicon-based resequencing to help The Broad with a number of important research projects," said Gajus Worthington, Fluidigm President and Chief Executive Officer. 

The Fluidigm Access Array System can be used with any PCR-based sample preparation method and with the reagents and primers of the customer's choosing. Fluidigm offers Access Array Target-specific Primers as an easy way for customers to generate sequencer ready amplicons for next-generation sequencing. Currently, Fluidigm offers custom PCR-based primer design for human targeted resequencing.  The Access Array System includes specific single-use microfluidic Integrated Fluidic Circuits (IFCs), two IFC Controllers, and a stand-alone thermal cycler to deliver results in just four hours.

Fluidigm (NASDAQ:FLDM) develops, manufactures and markets microfluidic systems for growth markets in the life science and agricultural biotechnology, or Ag-Bio, industries. Fluidigm's proprietary microfluidic systems consist of instruments and consumables, including integrated fluidic circuits, or chips, and reagents. These systems are designed to significantly simplify experimental workflow, increase throughput and reduce costs, while providing the excellent data quality demanded by customers. Fluidigm actively markets three microfluidic systems including nine different commercial chips to leading pharmaceutical and biotechnology companies, academic institutions and Ag-Bio companies.

For more information, please visit
www.fluidigm.com.

Monday, 4 July 2011

Just Published: Chemometrics and Intelligent Laboratory Systems

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Selected papers from the latest issue ...

Joint multiple adaptive wavelet regression ensembles

30 June 2011, 21:35:04Go to full article
Publication year: 2011
Source: Chemometrics and Intelligent Laboratory Systems, In Press, Accepted Manuscript, Available online 30 June 2011
David, Donald , Danny, Coomans , Yvette, Everingham
Multiple adaptive discrete wavelet transforms were applied during a multiple regression of spectroscopic data for the purpose of investigating the hypothesis – does the use of different wavelets, at different points, within a spectrum, elucidate predictive capability. The model investigated was a constrained stacking regression ensemble with individual regression models chosen initially by a Bayes Metropolis search. The ensemble approach provided the ability to combine different regression models that used different types of wavelets. Models were applied to a publically available dataset, pertaining to biscuit dough, of near infrared spectra, that were measured by a FOSS 5000, and laboratory measurements...

Construction of space-filling designs using WSP algorithm for high dimensional spaces

26 June 2011, 21:20:54Go to full article
Publication year: 2011
Source: Chemometrics and Intelligent Laboratory Systems, In Press, Accepted Manuscript, Available online 26 June 2011
J., Santiago , M.Claeys-Bruno , M., Sergent
In the computer experiments setting, if the relationship between the response and the inputs is unknown, then the purpose is to use designs that spread the points at which the response is observed evenly throughout the region. These designs are called Space-Filling Designs (SFD) and the most known are Latin Hypercubes (random, orthogonal, optimized) and low discrepancy sequences. But, simulation codes becoming more and more complex, high dimensional optimal designs are needed to study a high number of parameters (more than 20 parameters) and the construction proves difficult. The aim of this study is to explore a construction method of...

Independent components analysis applied to 3D-front-face fluorescence spectra of edible oils to study the antioxydant effect of Nigella sativa L. extract on the thermal stability of heated oils

25 June 2011, 21:23:09Go to full article
Publication year: 2011
Source: Chemometrics and Intelligent Laboratory Systems, In Press, Accepted Manuscript, Available online 25 June 2011
Faten, Ammari , Christophe B.Y., Cordella , Néziha, Boughanmi , Douglas N., Rutledge
Independent Components Analysis (ICA) is one of the most widely used methods for blind source separation. In this paper we use this technique to facilitate the analysis of 3D- front face fluorescence spectra and to evaluate the efficiency of Nigella seed extract as a natural antioxidant compared with butylated hydroxytoluene (BHT) during accelerated oxidation of edible vegetable oils at 120°C, 140°C, 170°C and 190°C.ICA has demonstrated its power to extract the most informative signals and thus to allow the interpretation of the differences observed in the corresponding IC scores between Control, BHT-spiked and Nigella-spiked samples.The results of the study clearly...

A nonparametric approach based on a Markov like property for classification

24 June 2011, 21:29:44Go to full article
Publication year: 2011
Source: Chemometrics and Intelligent Laboratory Systems, In Press, Accepted Manuscript, Available online 24 June 2011
Eun Sug, Park , Clifford, Spiegelman , Jeongyoun, Ahn
We suggest a new approach for classification based on nonparametricly estimated likelihoods. Due to the scarcity of data in high dimensions, full nonparametric estimation of the likelihood functions for each population is impractical. Instead, we propose to build a class of estimated nonparametric candidate likelihood models based on a Markov property and to provide multiple likelihood estimates that are useful for guiding a classification algorithm. Our density estimates require only estimates of one and two-dimensional marginal distributions, which can effectively get around the curse of dimensionality problem. A classification algorithm based on those estimated likelihoods is presented. A modification to...

Productive SPE Sample Preparation

The MaxiLute™ solid phase extraction (SPE) system from Porvair Sciences is fully compatible with automated liquid handling and robotic devices providing considerable productivity benefits.

The MaxiLute is a novel 48-well SPE microplate system that offers significant advantages for laboratories currently using SPE cartridges.  The MaxiLute offers the capability to process up to 200ml of sample in one go repeatedly and precisely.  Each well on the MaxiLute has an individual drain spout ensuring 100% sample transfer and zero cross over contamination. Constructed from a single piece of moulded high quality plastic - the MaxiLute will not bend or distort because individual SPE cartridges do not have to be repeatedly plugged in and out.

The MaxiLute™ solid phase extraction microplate system from Porvair Sciences offers unmatched optimised processing of drug development, food and environmental samples.

Available with a wide range of proprietary high performance Porvair sorbents in addition to accommodating a choice of sorbents from other manufacturers, MaxiLute offers the flexibility to be packed to perform optimally for almost any SPE application.  Supplying a complete methods development product that you don't have to construct yourself means valuable laboratory time is saved in the sample preparation process.

For further information on the MaxiLute please contact Porvair Sciences on telephone +44-1372-824290 or email int.sales@porvair-sciences.com.

Friday, 1 July 2011

Traceable® Big-Digit Refrigerator Thermometer

Control Company’s new Traceable® Wide-Range Big-Digit Refrigerator Thermometer has 7/8-inch high display that is easy to view. Switchable range is from –3.8 to 199.9°F and –19.9 to 110.0°C with a resolution of 0.1°. Accuracy is ±1ºC in the range 0 to 25°C and ±1.5°C outside range. Ultra™ model accuracy is ±0.5°C at tested points. May be placed anywhere using four methods: Always-hold™ secure suction cup, place-anywhere Velcro®, stand, and hanger. Display updates every 30 seconds (this allows capturing a reading while allowing a momentary open refrigerator door). Wide range of the thermometer also makes it an ideal unit to monitor temperatures in storerooms, labs, offices, hoods, and outdoors.
To assure accuracy an individually serial-numbered Traceable® Certificate is provided from our ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology).
Supplied with long-life battery. Size is 3½ x 2 x ¾ inches. Weight is 1-1/8 ounces.
For more information, contact Control Company, 4455 Rex Road, Friendswood, TX 77546;  Phone: 281-482-1714; Fax: 281-482-9448;  www.control3.com;  E-mail:  sales@control3.com

Precise and Reliable Microinjections

Warner Instruments is pleased to introduce the New PLI-100A Pico-Injector for accurate femtoliter to microliter injections.  Whether you need large injections into capillaries or small injections in mammalian nuclei, the PLI-100A injector is the one for you.
Injections are delivered through micropipettes by applying a regulated pressure for a digitally set period of time.  Pressure to the pipette is controlled precisely through a multi-turn regulator and is reported digitally for reproducibility.
Injection time is set using an optically encoded circuit which permits fine and coarse settings from a single knob.  Control the timer via the panel push button, footswitch, or external trigger input.
The PLI-100A has unique “Balance”, “Clear”, and “Hold” functions, not found in other microinjection units.  These pressure functions help to eliminate dilution & clogging and allow the user to fill the pipette from the tip and hold suspended cells.
Warner Instruments is a designer and manufacturer of biomedical devices for the electrophysiological, cellular and neurological sciences.
For more information contact:
Warner InstrumentsA Harvard Apparatus Company1125 Dixwell Avenue
Hamden, CT 06514 USA
Toll Free: 800-599-4203
Phone: 203-776-0664
Fax: 203-776-1278
E-mail: pr@warneronline.com
Web: http://www.warnerinstruments.com/