World Congress on Biosensors 2014

World Congress on Biosensors 2014
Biosensors 2014

Tuesday, 25 June 2013

Ultra Compact 0.50ml Storage Tube

The Octygen 0.50ml screw cap tube available from Micronic sets a new standard for low temperature sample storage.

In low temperature storage facilities the cost of freezer space is an important cost of operation both in terms of the number of freezers required and electricity costs.  The ultra-compact design of the Octygen tubes at just 25.6mm tall to deliver 475µl working volume uses only 60% of the space that competitive 0.50ml 96-well format screw cap tubes use to store the same volume.  To further optimise use of valuable storage space - 96 individual 0.50ml Octygen tubes can be stored in an automation compatible rack. The unique design of the Octygen tube means that a Revco -80°C freezer can store 120,960 0.50ml Octygen tubes compared to only 80,640 0.50ml tubes of a competitive design.

Designed for both manual and automated low temperature storage applications the external thread design of Octygen tubes facilitates fast and simple sample handling. A super safe polypropylene cap / polypropylene tube seal in the rim of each Octygen tube minimises diffusion of vapour during storage, even in dehumidified automation areas, thereby ensuring high sample integrity. To demonstrate the high sample integrity performance of the Octygen screw caps - Micronic performed two 4-week temperature tests at 21ºC (room temperature) and -80ºC (freezer temperature). The average weight loss at 21ºC during a 4-week period was only 0.0015 grams/week and at -80ºC no weight loss was detected.

Manufactured from high purity polypropylene in a controlled environment compliant with ISO 14644 and medical manufacturing standard ISO 13485 each Octygen tube is uniquely identified with a laser etched 2D Data-Matrix code that will never wear or fall off.

For further information about Octygen please visit www.octygen.com or contact Micronic Europe B.V. (Asia, Africa, Europe and Oceania) now on +31-320-277070 / email sales@micronic.com
or Micronic America LLC (North, Central and South America) on +1-484-480-3372.

Sunday, 23 June 2013

Comprehensive Tissue Biorepository and Collection Services

AMSBIO has announced further expansion of its tissue biorepository and collection services** to now include blood products from human donors with auto-immune and neurological conditions. Whole blood, plasma, serum, PBMCs and cerebrospinal fluid samples are available from a wide variety of donors.  In addition AMSBIO is now able to offer collection services of patient samples that meet the demographic and medical history requirements of specific research studies.

Drawing upon over 20 years of serving this market - AMSBIO has established one of the most comprehensive ranges of tissue products to advance personalised medicine by putting these valuable samples in the hands of leading researchers.

Samples are available isolated from hundreds of different source tissues including human normal and diseased tissues, and a variety of genetic model organisms including mouse, rat, primates and plant species. These specimens are provided ready-to-use enabling the immediate study of molecules of interest eliminating the need for time consuming in-house sample collection and preparation.

These tissue products further extend AMSBIO's extensive bank of clinical and veterinary specimens that form a unique range of specimens in formalin fixed paraffin embedded (FFPE) or snap frozen formats. This extensive library of samples includes genomic DNA preparations, tissue specific PCR-ready first strand cDNAs, universal cDNA and 96 well and 384 well cDNA panels. Total, universal RNA and micro and total protein lysates are also available.

All tissue products are produced using rigorous standard operating procedures and through ethical procurement to ensure only the highest quality materials. For further information on our tissue biorepository and  collection services please visit http://www.amsbio.com/Tissues.aspx** or contact AMSBIO on +44-1235-828200 / +1-800-987-0985 or email info@amsbio.com
.

Tuesday, 18 June 2013

Orbital Shaker Helps Accelerate Protein Precipitation Sample Preparation

Porvair Sciences has announced an online video demonstrating its MicroShake™ orbital shaker and how it can be used to accelerate sample preparation when using the company's popular p3 protein precipitation plates.

By simply placing a p3 plate on the MicroShake™ dedicated plate holder and agitating for less than 30 seconds - rapid and complete mixing of serum samples with acetonitrile is ensured. The MicroShake™ has been rigorously tested with p3 plates to ensure that no breakthrough of supernatant liquid can occur and has been shown to be the fastest way to ensure protein precipitation throughout the sample.

The MicroShake™ uses a 15 volt power supply and is fitted with a speed adjuster. This compact, reliable and quiet unit is similar in size to a standard format microplate and will fit on any bench, in any fume hood or even the deck of your liquid handler. For added peace of mind and to eliminate any risk of contamination, the p3 plates can be fitted with a re-usable silicone cap mat. A simple adjustment enables the MicroShake™ to be used with any standard footprint microplate.

The p3 plate is proven to eliminate the mess and complex sample preparation (no centrifuging, no vortexing) associated with traditional protein precipitation sample preparation techniques. Based on the industry standard Microlute™ design, the p3 plate enables 96 samples to be prepared simultaneously.

Established in 1992, Porvair Sciences Ltd. has developed internationally recognised expertise in microplate technology and manufacturing serving applications in Drug Discovery, Combinatorial Chemistry, Solid Phase Extraction, Protein Purification, High Throughput Screening, Environmental Analysis, Proteomics and Genomics.   Porvair Sciences Ltd. is a wholly owned subsidiary of Porvair plc.

To watch the video please visit http://www.porvair-sciences.com/videos. For further information on the MicroShake™ orbital shaker please contact Porvair Sciences Ltd. on telephone +44-1372-824290, email int.sales@porvair-sciences.com or visit http://www.porvair-sciences.com/en/services-menu/equipment/microshake-orbital-shaker/

Monday, 17 June 2013

HPLC 2013 Starts!!

HPLC 2013 got underway yesterday with an early registration and plenary lectures by Jos Beijinen (Fight Against Cancer), Ron Majors (Top Ten HPLC Column Myths), Michel Nielen (Forget Everything, Except Mass Spectrometry) and Stefan Bruns (From Pore Level Reconstruction to Morphological) set the bar at a high level from the outset.

Today saw the cream of the world's chromatography community arriving at Amsterdam's RAI conference and exhibition centre as the main conference began. Here are a selection of photographs from Day One.

Elsevier will be hosting a beer and wine reception this evening to thank reviewers and more photos (none of an incriminating nature of course) will appear tomorrow.






Just Published: Journal of Chromatography A

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:
Journal of Chromatography A

Selected papers from the latest issue:

C12-Ag wire as solid-phase microextraction fiber for determination of benzophenone ultraviolet filters in river water

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Jian Li , Liyun Ma , Minqiong Tang , Li Xu
In the present study, a novel approach for fabrication of solid-phase microextraction (SPME) fiber based on silver wire was proposed. 3-(Mercaptopropyl) trimethoxysilane (MPTS) was self-assembled on the silver wire by the special interaction between Ag and S, producing MPTS-Ag wire. The MPTS-Ag wire was then functionalized with dodecyltrimethoxysilane via sol–gel approach, giving C12-Ag wire. The preparation conditions were systematically optimized. The prepared fiber was then used as the SPME fiber to extract three benzophenone UV filters from the river water. The developed method showed good linearity between 0.005 and 0.200μgmL−1 with regression determination coefficients in the range of 0.9929–0.9988 and detection limits ranging from 0.58 to 1.86ngmL−1. The C12-Ag fiber exhibited good stability and long lifetime, and could be an alternative to the traditional fused silica fiber.

Simultaneous extraction of metabolome and lipidome with methyl tert-butyl ether from a single small tissue sample for ultra-high performance liquid chromatography/mass spectrometry

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Shili Chen , Miriam Hoene , Jia Li , Yanjie Li , Xinjie Zhao , Hans-Ulrich Häring , Erwin D. Schleicher , Cora Weigert , Guowang Xu , Rainer Lehmann
A common challenge for scientists working with animal tissue or human biopsy samples is the limitation of material and consequently, the difficulty to perform comprehensive metabolic profiling within one experiment. Here, we present a novel approach to simultaneously perform targeted and non-targeted metabolomics as well as lipidomics from one small piece of liver or muscle tissue by ultra-high performance liquid chromatography/mass spectrometry (UHPLC/MS) following a methyl tert-butyl ether (MTBE)-based extraction. Equal relative amounts of the resulting polar and non-polar fractions were pooled, evaporated and reconstituted in the appropriate solvent for UHPLC/MS analysis. This mix was comparable or superior in yield and reproducibility to a standard 80% methanol extraction for the profiling of polar and lipophilic metabolites (free carnitine, acylcarnitines and FFA). The mix was also suitable for non-targeted metabolomics, an easy measure to increase the metabolite coverage by 30% relative to using the polar fraction alone. Lipidomics was performed from an aliquot of the non-polar fraction. This novel strategy could successfully be applied to one mouse soleus muscle with a dry weight of merely 2.5mg. By enabling a simultaneous profiling of lipids and metabolites with mixed polarity while saving material for molecular, biochemical or histological analyses, our approach may open up new perspectives toward a comprehensive investigation of small, valuable tissue samples.

Model-based prediction of monoclonal antibody retention in ion-exchange chromatography

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Bertrand Guélat , Lydia Delegrange , Pascal Valax , Massimo Morbidelli
In order to support a model-based process design in ion-exchange chromatography, an adsorption equilibrium model was adapted to predict the protein retention behavior from the amino acid sequence and from structural information on the resin. It is based on the computation of protein–resin interactions with a colloidal model and accounts for the contribution of each ionizable amino acid to the protein charge. As a verification of the protein charge model, the experimental titration curve of a monoclonal antibody was compared to its predicted net charge. Using this protein charge model in the computation of the protein–resin interactions, it is possible to predict the adsorption equilibrium constant (i.e. retention factor or Henry constant) with an explicit pH and salt dependence. The application of the model-based predictions for an in silico screening of the protein retention on various stationary phases or, alternatively, for the comparison of various monoclonal antibodies on a given cation-exchanger was demonstrated. Furthermore, considering the structural differences between charge variants of a monoclonal antibody, it was possible to predict their individual retention times. The selectivity between the side variants and the main isoform of the monoclonal antibody were computed. The comparison with the experimental data showed that the model was reliable with respect to the identification of the operating conditions maximizing the selectivity, i.e. the most promising conditions for a monoclonal antibody variant separation. Such predictions can be useful in reducing the experimental effort to identify the parameter space.

Distributed pore model for bio-molecule chromatography

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Bertrand Coquebert de Neuville , Abhijit Tarafder , Massimo Morbidelli
One of the main peculiarities in protein chromatography is that the adsorbing proteins and the adsorbent pores have comparable sizes. This has the consequence that the pore accessibility depends not only on the solute size but also on the loading conditions of the adsorbent because protein adsorption significantly reduces the size of the pores. A model that accounts for the pore size distribution of the stationary phase and for the pore shrinkage due to protein adsorption has been developed to describe mass transport and adsorption in the porous particles. This model has been shown to be equivalent to the general rate model (GRM) in the case of processes under highly diluted conditions with little adsorption. This implies that the model parameters determination follows the same procedure as for the classical GRM. The new pore model has been applied and compared to the GRM for the simulation of lysozyme breakthrough experiments and for the prediction of 5% dynamic binding capacity values solely based on static capacity measurements.

Preparation and evaluation of 1,6-hexanediol ethoxylate diacrylate-based alkyl methacrylate monolithic capillary column for separating small molecules

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Shu-Ling Lin , Yu-Ru Wu , Tzuen-Yeuan Lin , Ming-Ren Fuh
Due to the high porosity, good thermal stability, and good physical stability at high pressure, polymer monoliths have been successfully utilized as the stationary phases for capillary liquid chromatography (LC) analysis. In this study, we introduced 1,6-hexanediol ethoxylate diacrylate (HEDA) as a cross-linker to prepare alkyl methacrylate monoliths for efficient separation of polar small molecules. HEDA provided additional dipole–dipole interactions between the monolithic stationary phases and polar analytes. For comparison, ethylene dimethacrylate and 1,6-hexanediol dimethacrylate were also utilized as cross-linkers to prepare alkyl methacrylate monoliths. A series of alkyl methacrylate polymeric monoliths were synthesized in fused-silica capillaries using the three different cross-linkers. The porosity, permeability and column efficiency of the synthesized alkyl methacrylate monoliths were characterized. A mixture of phenol derivatives was employed to evaluate the applicability of the prepared monolithic columns for separating small molecules using capillary LC. The HEDA-based alkyl methacrylate monoliths offered the most efficient chromatographic separation for phenol derivatives. Moreover, the capability of applying the novel HEDA-based alkyl methacrylate monolithic columns for potential environmental analysis was demonstrated by separating eight phenylurea herbicides.

Analysis of immobilized artificial membrane retention factors for both neutral and ionic species

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Michael H. Abraham , William E. Acree Jr. , Alfred Fahr , Xiangli Liu
Retention data on an immobilised artificial membrane have been taken from the work of Li et al. and from Liu et al., and have been correlated with a set of descriptors that includes descriptors for ionized species, that is anions from deprotonated acids and cations from protonated bases. Log k(IAM) values can be predicted for acids or bases that are partially ionized at the experimental pH and log k(IAM) values for acids and bases can be predicted as a function of the fraction present as the ionized species, equivalent to prediction as a function of pH. It is shown that anions reduce the value of log k(IAM) by about 1.1log units but that cations have almost no effect by comparison to the neutral species. By comparison to non-polar solvents, carboxylate anions and protonated base cations are considerably stabilized by both water and the IAM phase to about 6–8log units and so the rather small influence of anions (−1.1log unit) and cations (−0.1log unit) on log k(IAM) is due to substantial cancellation of these stabilization effects. Indeed, the effect of change of phase from water to IAM on the neutral species is at least as large as the effect of change of phase on the ionic species.

Direct quantification of bacterial molybdenum and iron metallophores with ultra-high-performance liquid chromatography coupled to time-of-flight mass spectrometry

17 June 2013, 14:44:09
Publication date: 12 July 2013
Source:Journal of Chromatography A, Volume 1298
Author(s): Michael Deicke , Jean-Philippe Bellenger , Thomas Wichard
Metallophores are a unique class of organic ligands released, for example, by nitrogen fixing bacteria in their environment in order to recruit the micronutrients molybdenum (Mo) and iron (Fe). Mo and Fe are essential cofactors of nitrogenase that reduces atmospheric nitrogen into bioavailable ammonium. Upon release, these bacterial metallophores bind to both metal cations and oxo-anions in the extracellular medium increasing the bioavailability of the metals to the nitrogen fixers, which can subsequently recruit the complexes. The efficient quantification of those metal complexes is crucial for the understanding of the homeostasis of the metal cofactors of nitrogenase (e.g., Fe and Mo), the dynamics of nitrogen fixation and the nitrogen cycle. A novel direct ultra-high-performance liquid chromatography coupled to a time-of-flight mass spectrometer (UHPLC-ToF-MS) was developed to quantify and monitor the production of Fe and Mo complexes of the catecholate metallophores protochelin (Prot) and azotochelin (Azo) in the growth medium of the nitrogen fixer and model organism Azotobacter vinelandii. Chromatographic separations were carried on a reversed C18-phase with a mobile phase ramped from water to acetonitrile spiked with 1mmol/L ammonium acetate (pH 6.6) to achieve stability of the metal complexes. Linearity for Mo-protochelin and Fe-protochelin was found at the concentration range between 5.0×10−8 and 9.0×10−7 mol/L with a limit of detection of 2.0×10−8 and 3.0×10−8 mol/L, respectively. The coefficient of variation of the procedure is in the range from 1.5 to 3.4%. The validation has hence demonstrated that the UHPLC-ToF-MS methodology is a fast, precise, specific, robust, and sensitive approach allowing the direct measurement of metallophores in growth medium without any sample preparation. The UHPLC-ToF-MS methodology was applied to the analysis of metallophores in our laboratory. Under lower Mo concentration, the Mo-protochelin concentration peaks in the middle lag phase, while the Fe-protochelin concentration rises to two maxima at the beginning of the exponential phase and during the stationary phase. The results indicate that the production of metallophores is highly dynamic throughout the growth and has to be monitored with high sensitivity and temporal resolution. 

Reagent Reservoirs for 96 and 384 Well Pipetting Systems

INTEGRA has announced an extension of its range of reagent reservoirs for 96-well and 384-well multichannel pipetting systems.

Adopting a standard SBS / SLAS footprint - the extended range of  reagent reservoirs (100ml and 300ml) are fully compatible with all liquid handling systems including INTEGRA's VIAFLO 96 and VIAFLO 384 Handheld Multichannel Electronic Pipettes.

Individual pyramidal indentations (96 or 384) in each reagent reservoir allow maximum liquid recovery when using the VIAFLO 96 and VIAFLO 384 electronic pipettes as well as other platforms.

VIAFLO multichannel reagent reservoirs are both economically and environmentally friendly because users can reuse the reservoir base and dispose of the reservoir inserts. These reagent reservoirs are also designed to nest within one another without sticking and come in compact, space-saving packages.

For further information on VIAFLO multichannel reagent reservoirs please visit
http://www.integra-biosciences.com/sites/us/reagent_reservoirs.html or contact INTEGRA Biosciences in Europe / Asia on telephone +41-81-286-9530 / email info@integra-biosciences.com or in North / South America on telephone +1-603-578-5800 / email US@integra-biosciences.com.


Tuesday, 11 June 2013

Just Published: Microchemical Journal

A new issue of this journal has just been published. To see abstracts of the papers it contains (with links through to the full papers) click here:

Selected papers from the latest issue:

Occurrence, transportation, monitoring and treatment of emerging micro-pollutants in waste water — A review from global views

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Jia-Qian Jiang , Z. Zhou , V.K. Sharma
This paper collects data from worldwide research groups and aims to critically review and analyse the advances of knowledge development in the area of occurrence, transportation, monitoring and treatment of emerging micro-pollutants from around the globe and to recommend the research needs in this research area. This review discovers that •A waste water treatment plant is one of pathways for micro-pollutants to transfer into surface waters; •Sample preparation, matrix effects and validation methods are challenges and more advanced analytical instrumentation and procedures are critical in analysing emerging micro-pollutants; •Traditional activated sludge and/or bio-filtration processes showed less efficiency to remove emerging micro-pollutants; •Advanced oxidation processes need to be validated for the efficiency and cost effectiveness; • More researches are needed to classify the type and toxicity of by-products resulting from the reactions between advanced oxidation processes and emerging micro-pollutants. The suggested future research needs from this review are challenges but provide us opportunities to effectively monitor and eliminate emerging micro-pollutants in the environment.

Determination of selenium compounds in food supplements using reversed-phase liquid chromatography–inductively coupled plasma mass spectrometry

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Yu-Jhe Hsieh , Shiuh-Jen Jiang
A reversed phase HPLC–ICP-MS method for the speciation of selenium compounds is described. Chromatographic separation was performed in a gradient elution mode using 2mmolL−1 sodium 1-pentanesulfonate and 5mmolL−1 citric acid in 3% methanol (pH2.70) and 5mmolL−1 NaH2PO4 and 5mmolL−1 citric acid in 3% methanol (pH2.77). The potentially interfering 38Ar40Ar+ and 40Ar40Ar+ at selenium masses of m/z 78 and 80 were reduced in intensity significantly by using 1.0mLmin−1 CH4 as a reactive cell gas in the dynamic reaction cell. Calibration curves were linear in the range 0.1–10μgL−1. The detection limits of the procedure were in the range of 0.04–0.07μgSeL−1. This method has been applied to determine various selenium compounds in NIST SRM 1567a Wheat Flour and food supplements purchased locally. The accuracy of the method has been verified by comparing the sum of the concentration of individual species obtained by the present procedure with the total concentration of the element. The selenium compounds were quantitatively extracted with a mixture of Protease XIV and mobile phase solution in a microwave field at 37°C during a period of 30min. The extraction efficiency was better than 91%. The spike recoveries were in the range of 92–104% for all determinations. The electrospray ionization-mass spectrometer has been tested to identify the unknown selenium compounds detected in the food supplements. γ-glutamyl-methyl-Se-cysteine was identified in one brand of the Selenium Tablet.

Highlights

► Selenium compounds in food supplements were determined using HLPC–ICP-MS. ► Ar dimer ion interferences on Se determination were suppressed with CH4 as the DRC reaction gas. ► Selenium species were quantitatively extracted using microwave heating. ► γ-Glutamyl-methyl-Se-cysteine was identified in Selenium Tablet using ESI-MS/MS.

Transport of selenium species in Caco-2 cells: Analytical approach employing the Ussing chamber technique and HPLC-ICP-MS

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Denis Pick , Christian Degen , Matthias Leiterer , Gerhard Jahreis , Jürgen W. Einax
Essential trace elements such as selenium (Se) play a crucial role in health and diseases. Investigations of the transport and absorption of different Se species in vivo and in vitro consider only one Se species in a systematic manner. Thus, transport of four Se compounds (at concentrations of 100 and 400μgL−1) namely selenite (SeO3 2−), selenate (SeO4 2−), selenomethionine (SeMet), and Se-methylselenocysteine (MeSEC) was compared using the Caco-2 cell line and the Ussing chamber system. For analytical measurements, an HPLC-ICP-DRC-MS method was developed and characterized. For the investigated Se species, limits of quantification were 0.5μgL−1 while trueness was tested using the certified reference material SELM-1. Se species were added to the apical compartment of the Ussing chamber system either separately or simultaneously. Notably, no transport for SeO3 2− from apical to basolateral side was observed. Transport efficacy after 120min was the highest (9.1%) for SeMet in single species experiments, whereas SeO4 2− transport was the highest (7.9%) associated with simultaneous adding of Se species. Furthermore, changes in rank order of the apparent permeability coefficients Papp were obtained in mixture experiments as compared to the single species approaches. Finally, experimental data demonstrate alterations in transport of SeMet, MeSEC, and SeO4 2− suggesting interactions between Se species and changes in the transport behavior.

Highlights

► A simple and fast HPLC-ICP-DRC-MS method was developed for analysis of Se species. ► Se species were added to the Caco-2 cell model either simultaneously or separately. ► Selenite transport across Caco-2 cell monolayers is especially slow. ► Presence of other Se species influences the transport of selenate, SeMet, and MeSEC.

A portable fiber-optic Raman analyzer for fast real-time screening and identifying cocrystal formation of drug-coformer via grinding process

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Hong-Liang Lin , Gang-Chun Zhang , Po-Chun Hsu , Shan-Yang Lin
A portable Raman analyzer with a fiber-optic probe was first used to rapidly screen and identify the cocrystal formation between drug and coformer. Indomethacin (IMC) and anhydrous theophylline (TP) were selected as model drugs, but saccharin (SAC) and anhydrous citric acid (CA) were chosen as model coformers. The cocrystal formation that occurred in the solid-state IMC–SAC or TP–CA system via mechanical grinding process was investigated. Differential scanning calorimetry (DSC) was also used to investigate the possible cocrystal formation. The present study indicates that this new portable fiber-opticRaman spectroscopic technique was an easy and fast “real-time” method to screen and identify the progressive cocrystal formation in solid-state IMC–SAC or TP–CA system in the process of mechanical grinding by inserting the probe directly into the ground mixtures.

Post-fire study of the Brazilian Scientific Antarctic Station: Toxic element contamination and potential mobility on the surrounding environment

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Marcelo Braga Bueno Guerra , Elias Lima Neto , Marcelo Tesser Antunes Prianti , Edenir Rodrigues Pereira-Filho , Carlos Ernesto Gonçalves Reynaud Schaefer
We evaluated the new on site soil conditions and their potential risks immediately after a fire that completely destroyed the Brazilian Antarctic Station, on February 2012. The investigated variables were the concentration of potentially toxic elements (Cd, Cr, Cu, Mn, Ni, Pb, V and Zn) in soil samples collected close to the station and inside the burnt station's ruins. Soil samples collected 4years before the fire were used as reference samples for comparative purposes. Principal Component Analysis (PCA) and μ-X-Ray Fluorescence were used as preliminary tools to provide fast and reliable qualitative information about soil pollution. Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) was chosen for the quantitative determination of the chemical elements under study. A Toxicity Characteristic Leaching Procedure was applied to access the potential mobility of the chemical elements in the environment. We found high pseudototal concentrations of Cu, Pb and Zn in soils collected within the station's ruins reaching the alarming levels of 34,000±4,000, 13,700±500 and 42,200±1,700mgkg−1, respectively. A point that deserves a close and special attention is the possible contamination of nearby lakes that supply the station with water, due to the high leachable Pb and Zn concentrations of the contaminated soil. Also, attention should be given to the possible development of melting channels carrying contaminated water to the coastal marine ecosystem. Due to its high risk of contamination, a complete clean-up procedure ought to be carried out, with barriers to avoid leaching/washing, removal of all debris and underlying soil, and careful disposal of the contaminated material, followed by remediation.

Highlights

► We evaluated the post-fire condition of soil samples near the Brazilian Antarctic Station. ► Copper, Pb and Zn presented alarming levels in the soil samples collected. ► μ-X-Ray Fluorescence in combination with chemometrics provides fast and reliable information. ► A complete clean-up procedure ought to be carried out to avoid leaching/washing.

Mercury species determination by task specific ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction combined with cold vapour generation atomic absorption spectrometry

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Ewa Stanisz , Justyna Werner , Henryk Matusiewicz
Task specific ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (TSIL USA DLLME) combined with cold vapour atomic absorption spectrometry (CV AAS) for determination of mercury species in water and biological samples was developed. The proposed procedure was free of volatile organic solvents, and there was no need to use any dispersive solvents and complexing agents, in contrast to standard DLLME. Analytical signals were obtained without the back-extraction of the mercury species from the TSIL phase into an aqueous phase prior to their determination by CV AAS. The reducing agent Sn2+ could reduce Hg2+ and CH3Hg+ for determination of total mercury. Some essential parameters of the microextraction and cold vapour generation, such as the pH of sample solution, volume of the ionic liquid, ultrasonication time, cooling time, centrifugation time, matrix interferences and salt effect have been studied. Under optimal conditions, high extraction efficiency was achieved for the extraction of 1.0ngmL−1 of Hg2+ and 5ngmL−1 CH3Hg+ in 10.0mL of water solution employing 30μL of methyltrioctylammonium thiosalicylate as the extraction solvent. The enrichment factor for the method was 310 for Hg2+ and 200 for CH3Hg+. The detection limits were 0.03ngmL−1 for Hg2+ and 0.4ngmL−1 for CH3Hg+ respectively. The accuracy of the proposed method was evaluated by analysis of the Certified Reference Materials (NRCC DOLT-2, NIST 1643e). The method was applied to analysis of the tap, river, lake and sea water samples. The recoveries for reference materials and spiked samples were in the range of 95-103%.

Highlights

► The preconcentration of mercury species with TSIL USA DLLME is optimized. ► The determination by CV AAS in organic phase without back-extraction is proposed. ► The method requires low volume of sample and reagents. ► A low limit of detection, good precision and high enhancement factor were obtained. ► An application to mercury species determination in complex matrices was shown.

Study of the effect of plasticizer on the structure and surface characteristics of ethylcellulose free films with FT-IR spectroscopy

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Diána Hegyesi , Tamás Sovány , Ottó Berkesi , Klára Pintye-Hódi , Géza Regdon Jr.
The investigation of free films is an essential part of the preformulation studies, because it is necessary to know, weather the given formulation is suitable to coat the corpus or not. As preformulation, the relationships between surface properties, and the structure of ethylcellulose free films containing different amount of plasticizer were studied. The structure analysis, and the incorporation of the plasticizer was performed with the use of FT-IR analysis. The results showed that the films are suitable to produce diffusion coatings.

Sensitive voltammetric responses and mechanistic insights into the determination of residue levels of endosulfan in fresh foodstuffs and raw natural waters

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Francisco W.P. Ribeiro , Thiago M.B.F. Oliveira , Francisco L.F. da Silva , Glaydson L.F. Mendonça , Paula Homem-de-Mello , Helena Becker , Pedro de Lima-Neto , Adriana N. Correia , Valder Nogueira Freire
This paper describes the electroanalytical study of the organochlorine pesticide endosulfan (EDS) using square-wave voltammetry. The electrochemical behaviour showed a quasi-reversible process on a hanging mercury drop electrode (HMDE) in acid medium attributed to reduction of the carbon–chlorine bond. The constant of change transfer obtained for this process was 354s−1. The redox mechanism was confirmed by quantum-chemical (Density Functional Theory, DFT) studies. The optimised experimental and voltammetric parameters were 0.04molL−1 Britton–Robinson buffer (pH4.0), the pulse potential frequency of 200s−1, the amplitude of the pulse of 20mV, and the height of the potential step of 4mV. Analytical parameters such as linearity range, equation of the analytical curves, correlation coefficients, detection and quantification limits, recovery values, precision, and accuracy were obtained. The procedure was applied to the analysis of pesticide in complex samples: sugar cane, tomato, and raw natural waters. The recovery values demonstrated that the proposed methodology is suitable for determining EDS in such samples. The results indicated that the proposed procedure is stable and sensitive, with good reproducibility, and no complex procedure was necessary for sample preparation. The development of this electroanalytical procedure is therefore appropriate, as it provides adequate sensitivity and reliable methodology.

Highlights

► Endosulfan is a broad-spectrum insecticide and acaricide applied in different areas. ► HMDE and SWV were used in the electroanalytical methodology. ► EDS determination in sugar cane, tomato and raw natural water samples ► Quantum-chemistry in a proposition of pathway for EDS electroreduction.

Determination of critical micelle concentration of dendritic surfactant synthesized via a selective ring-opening addition reaction

11 June 2013, 10:59:19
Publication date: September 2013
Source:Microchemical Journal, Volume 110
Author(s): Chih-Hsiung Hsu , Shi-Min Shau , Ru-Jong Jeng , Hsin-Cheng Chiu , Shenghong A. Dai , Eric D. Conte , Shing-Yi Suen
An azetidine-2,4-dione was applied to synthesize dendrons with four carbons in the end ([G-0.5]-C4 and [G-1]-C4) via a selective ring-opening addition reaction, which was subsequently extended to obtain a dendritic surfactant ([G-1]-C4 surfactant) by acidification. The dendrons were characterized by Fourier transform infrared (FT-IR), 1H nuclear magnetic resonance (1H NMR), elemental analyzer (EA), and fast atom bombardment mass spectrometry (FAB MS). The dendritic surfactant, with a cationic head and branched hydrophobic C4 tails, was dissolved in 2wt.% dimethyl sulfoxide (DMSO) aqueous solution for the determination of critical micelle concentration (CMC) by fluorescence and electrical conductivity measurements. The resulted CMC values were very close within measurements, ca. 0.013–0.05mM. Transmission electron microscopy (TEM) and zeta potential measurement also provided an evidence of micelle formation and shape. Moreover, anionic dyes were adsorbed onto the micelles successfully to confirm the positive charge of [G-1]-C4 surfactant.

Highlights

► Dendrons with terminal C4 groups were synthesized from an azetidine-2,4-dione. ► By acidification, a dendritic surfactant was subsequently obtained. ► Its CMC was determined by fluorescence and conductivity measurements. ► The resulted CMC values were very close within measurements, ca. 0.013–0.05mM. ► Anionic dyes were adsorbed onto the dendritic surfactant micelles successfully.